DATA ANALYSIS AND RESULTS

PICKING UP LARGE HEAVY OBJECTS:

4.3 WITHIN GROUP ANALYSIS OF GROUP B:

 FUGL-MEYER ASSESSMENT SCALE (UPPER EXTREMITY): TEST MEAN ± STANDARD ERROR MEAN STANDARD DEVIATION T VALUE P VALUE PRE TEST 23.600 ± 0.266 0.843 -55.733 0.000 POST TEST 44.700 ± 0.300 0.948

Table No: 4: Within group analysis of fugl-meyer assessment scale (upper extremity) in experimental group (Group B)

The Pre mean and standard error mean value of fugl-meyer assessment scale (upper extremity) in group B were 23.600 ± 0.266 and the standard deviation value was 0.843 respectively.

The Post mean and standard error mean value of fugl-meyer assessment scale (upper extremity) in group B were 44.700 ±0.300 and the standard deviation value was 0.948 respectively.

The T value and P value were -55.733 and 0.000 respectively. The statistical report states that there was significant improvement in fugl-meyer assessment scale (upper extremity) after the application of functional electrical stimulation in experimental group.

34

 JEBSEN AND TAYLOR HAND FUNCTION TEST: JTHFT VARIABLES TEST MEAN ± STANDARD ERROR MEAN STANDARD DEVIATION T VALUE P VALUE HAND WRITING PRE TEST 21.200 ± 0.416 1.316 17.441 0.000 POST TEST 14.700 ±0.260 0.823 SIMULATED PAGE TURNING PRE TEST 14.800 ± 0.326 1.032 21.336 0.000 POST TEST 8.600 ± 0.305 0.966 PICKING UP SMALL COMMON OBJECTS PRE TEST 15.000 ± 0.258 0.816 26.842 0.000 POST TEST 7.200 ± 0.290 0.918 SIMULATED FEEDING PRE TEST 13.100 ± 0.276 0.875 22.841 0.000 POST TEST 9.000 ± 0.210 0.666 STACKING CHECKERS PRE TEST 12.600 ± 0.339 1.074 22.021 0.000 POST TEST 7.900 ± 0.233 0.737 PICKING UP LARGE LIGHT OBJECTS PRE TEST 14.600 ± 0.300 0.966 23.275 0.000 POST TEST 6.500 ± 0.166 0.527 PICKING UP LARGE HEAVY OBJECTS PRE TEST 15.200 ± 0.326 1.032 51.439 0.000 POST TEST 6.800 ± 0.290 0.918

Table No: 5: Within group analysis of Jebsen and Taylor hand Function test in Experimental group (Group B).

35 HAND WRITING:

The Pre mean and standard error mean value of hand writing components of Jebsen and Taylor hand Function test in group B were 21.200 ± 0.416 and the standard deviation value was 1.316 respectively.

The Post mean and standard error mean value of hand writing components of Jebsen and Taylor hand Function test in group B were 14.700 ±0.260 and the standard deviation value was 0.823 respectively.

The T value and P value were 17.441 and 0.000 respectively. The statistical report states that there was significant improvement hand writing components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

SIMULATED PAGE TURNING:

The Pre mean and standard error mean value of simulated page turning components of Jebsen and Taylor hand Function test in group B were 14.800 ± 0.326 and the standard deviation value was 1.032 respectively.

The Post mean and standard error mean value of simulated page turning components of Jebsen and Taylor hand Function test in group B were 8.600 ± 0.305 and the standard deviation value was 0.966 respectively.

The T value and P value were 21.336 and 0.000 respectively. The statistical report states that there was significant improvement hand simulated page turning components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

PICKING UP SMALL COMMON OBJECTS:

The Pre mean and standard error mean value of pick up small common objects components of Jebsen and Taylor hand Function test in group B were 15.000 ± 0.258 and the standard deviation value was 0.816 respectively.

The Post mean and standard error mean value of pick up small common objects components of Jebsen and Taylor hand Function test in group B were 7.200 ± 0.290 and the standard deviation value was 0.918 respectively.

36

The T value and P value were 26.842 and 0.000 respectively. The statistical report states that there was significant improvement hand pick up small common objects components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

SIMULATED FEEDING:

The Pre mean and standard error mean value of simulated feeding components of Jebsen and Taylor hand Function test in group B were 13.100 ± 0.276 and the standard deviation value was 0.875 respectively.

The Post mean and standard error mean value of simulated feeding components of Jebsen and Taylor hand Function test in group B were 9.000 ± 0.210 and the standard deviation value was 0.666 respectively.

The T value and P value were 22.841 and 0.000 respectively. The statistical report states that there was significant improvement hand simulated feeding components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

STACKING CHECKERS:

The Pre mean and standard error mean value of stacking checker components of Jebsen and Taylor hand Function test in group B were 12.600 ± 0.339 and the standard deviation value was 1.074 respectively.

The Post mean and standard error mean value of stacking checker components of Jebsen and Taylor hand Function test in group B were 7.900 ± 0.233 and the standard deviation value was 0.737 respectively.

The T value and P value were 22.021 and 0.000 respectively. The statistical report states that there was significant improvement hand stacking checker components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

37 PICKING UP LARGE LIGHT OBJECTS:

The Pre mean and standard error mean value of pick up large light objects components of Jebsen and Taylor hand Function test in group B were 14.600 ± 0.300 and the standard deviation value was 0.966 respectively.

The Post mean and standard error mean value of pick up large light objects components of Jebsen and Taylor hand Function test in group B were 6.500 ± 0.166 and the standard deviation value was 0.527 respectively.

The T value and P value were 23.275 and 0.000 respectively. The statistical report states that there was significant improvement hand pick up large light objects components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

PICKING UP LARGE HEAVY OBJECTS:

The Pre mean and standard error mean value of pick up large light objects components of Jebsen and Taylor hand Function test in group B were 15.200 ± 0.326 and the standard deviation value was 1.032 respectively.

The Post mean and standard error mean value of pick up large light objects components of Jebsen and Taylor hand Function test in group B were 6.800 ± 0.290 and the standard deviation value was 0.918 respectively.

The T value and P value were 51.439 and 0.000 respectively. The statistical report states that there was significant improvement hand pick up large light objects components of Jebsen and Taylor hand Function test after the application of conventional physiotherapy in experimental group.

38

4.4 BETWEEN GROUP ANALYSES:

 FUGL-MEYER ASSESSMENT SCALE (UPPER EXTREMITY):

TEST

GROUP

MEAN ±

STANDARD