• No results found

The object identifier for each MIB object is listed in Table 5-40.

The MIB objects are listed in Table 5-41.

Table 5-40 Interface Operation Table Object Identifiers

Name Object Identifier

cwspOperationTable ::= { cwspOperation 1 } cwspOperationEntry ::= { cwspOperationTable 1 } cwspOperIlmiEnable ::= { cwspOperationEntry 1 } cwspOperIfcType ::= { cwspOperationEntry 2 } cwspOperIfcSide ::= { cwspOperationEntry 3 } cwspOperMaxVPCs ::= { cwspOperationEntry 4 } cwspOperMaxVCCs ::= { cwspOperationEntry 5 } cwspOperMaxVpiBits ::= { cwspOperationEntry 6 } cwspOperMaxVciBits ::= { cwspOperationEntry 7 } cwspOperUniType ::= { cwspOperationEntry 8 } cwspOperUniVersion ::= { cwspOperationEntry 9 } cwspOperDeviceType ::= { cwspOperationEntry 10 } cwspOperIlmiVersion ::= { cwspOperationEntry 11 } cwspOperNniSigVersion ::= { cwspOperationEntry 12 } cwspOperMaxSvpcVpi ::= { cwspOperationEntry 13 } cwspOperMinSvpcVpi ::= { cwspOperationEntry 14 } cwspOperMaxSvccVpi ::= { cwspOperationEntry 15 } cwspOperMinSvccVpi ::= { cwspOperationEntry 16 } cwspOperMaxSvccVci ::= { cwspOperationEntry 17 } cwspOperMinSvccVci ::= { cwspOperationEntry 18 } cwspOperAddrPlanSupported ::= { cwspOperationEntry 19 }

Table 5-41 Interface Operation Table MIB Objects

Name Syntax Description

Default Value cwspOperationTable Sequence of

CwspOperationEntry

Specifies the interface operation table that contains the runtime negotiated values between the platform, PNNI controller, and peer for the interface.

Max-Access: not-accessible Status: current

none

cwspOperationEntry CwspOperationEntry Specifies an entry in the interface operation table that contains the negotiated values for the interface.

Max-Access: not-accessible Status: current

The index contains ifIndex.

none

cwspOperIlmiEnable TruthValue Explains the operational state of Interim Local Management Interface (ILMI).

Max-Access: read-only Status: current

none

cwspOperIfcType Integer { publicUni(1), privateUni(2), iisp(3), pnni(4), aini(5), enni(6)}

Specifies the interface type. It contains the following:

Public User-Network Interface (publicUni)

Private User-Network Interface (privateUni)

Interim Inter-Switch Signaling Protocol (IISP)

Private Network-to-Network Interface (PNNI)

ATM Inter-Network Interface (AINI)

Enhanced Network-to-Network Interface (ENNI) Max-Access: read-only

Status: current

none

cwspOperIfcSide INTEGER { userSide(1), networkSide(2),

symmetric(3) }

Explains the IME type of the ATM device that is determined by the automatic interface type determination procedure.

Refer to ATM Forum ILMI 4.0, Section 8.3.4.1.

Max-Access: read-only Status: current

none

cwspOperMaxVPCs Integer32 Specifies the maximum number of switched and permanent VPCs supported on this ATM interface.

Max-Access: read-only Status: current

none

cwspOperMaxVCCs Integer32 Specifies the maximum number of switched and permanent VCCs supported on this ATM interface.

Max-Access: read-only Status: current

none

cwspOperMaxVpiBits Integer32 Specifies the maximum number of active VPI bits on this ATM interface.

Max-Access: read-only Status: current

none

cwspOperMaxVciBits Integer32 Specifies the maximum number of active VCI bits on this ATM interface.

Max-Access: read-only Status: current

none

cwspOperUniType INTEGER { public(1), private(2) }

Specifies the type of the ATM device, for example, public or private.

Max-Access: read-only Status: current

none

cwspOperUniVersion INTEGER { uni20(1), uni30(2),

Indicates the latest version of the ATM Forum UNI Signaling Specification that is supported on this ATM Interface. If this value is not present, a version of the UNI earlier than 3.1 is supported.

If the peer IME value of this object is the same as or later than the local IME value, the version corresponding to the local IME value is attempted. Otherwise, if the peer IME value of this object is used earlier and supported locally, the local IME can use the version corresponding to the peer IME value. Otherwise, compatibility of the two IMEs cannot be assumed.

Max-Access: read-only Status: current

none

cwspOperDeviceType INTEGER { user(1), node(2) } Determines the type of ATM device. This object is used in an automatic ATM Interface-Type determination procedure so that a correct operational ATM

Interface-Type can be determined. An ATM End System can take the value user(1), and an ATM network node can take the value node(2).

Max-Access: read-only Status: current

none Table 5-41 Interface Operation Table MIB Objects (continued)

Name Syntax Description

Default Value

cwspOperIlmiVersion INTEGER

{ unsupported(1), version4point0(2) }

Indicates the latest version of the ATM Forum ILMI Specification that is supported on this ATM Interface. If the peer IME value of this object is the same as or later than the local IME value, the version corresponding to the local IME value is attempted. Otherwise, if the peer IME value of this object is earlier, and supported locally, the local IME can use the version that corresponds to the peer IME value. Otherwise, compatibility of the two IMEs cannot be assumed. If this object is not present, a version of the ILMI earlier than 4.0 is supported.

Max-Access: read-only enni(4), aini(5) }

Indicates the latest version of the ATM Forum PNNI Signaling Specification supported on this ATM Interface.

Note The PNNI routing version is not determined through ILMI.

If the peer IME value of this object is the same as or later than the local IME value, the version that corresponds to the local IME value is attempted. Otherwise, if the peer IME value of this object is earlier and supported locally, the local IME can use the version that corresponds to the peer IME value. Otherwise, compatibility of the two IMEs cannot be assumed.

Note enni is not a signaling protocol.

Max-Access: read-only Status: current

none

cwspOperMaxSvpc Vpi

Integer32 Determines the maximum switched VPC VPI.

Max-Access: read-only Status: current

none

cwspOperMinSvpc Vpi

Integer32 Determines the minimum switched VPC VPI.

Max-Access: read-only Status: current

none

cwspOperMaxSvcc Vpi

Integer32 Determines the maximum switched VCC VPI.

Max-Access: read-only Status: current

none

cwspOperMinSvcc Vpi

Integer32 Determines the minimum switched VCC VPI.

Max-Access: read-only Status: current

none Table 5-41 Interface Operation Table MIB Objects (continued)

Name Syntax Description

Default Value