In this lab, you will be using the following forms, in this order:

Hardware > Modules > Controller Module Configuration form.

Hardware > Framers > Dual T1-E1 Framers form.

Trunks > Digital > Digital Link Descriptors form.

Trunks > Digital > Digital Links form.

Trunks > Digital > MSDN/DPNSS/DASSII Trunk Circuit Descriptor form.

Trunks > Trunk Attributes form.

Trunks > Digital > Digital Trunks form.

Trunks > Digital > Network Synchronization form.

Trunks > Digital > ISDN > ISDN Protocol form.

System Properties > System Feature Settings > Class of Service Options form. Reference

Help > Contents > System Programming > Trunks > Digital Trunks > Program Embedded PRI/QSIG Trunks

Step Task Expected Result 9

1 Navigate to the Hardware > Modules > Controller Module Configuration form.

The Controller Module Configuration form is displayed.

2 Make sure that the module is programmed as a Dual T1-E1 Framer module. If it isn’t, program it for one.

The module is

programmed as a Dual T1- E1 Framer.

3 Navigate to the Hardware > Framers > Dual T1-E1 Framers form.

The Dual T1-E1 Framers form is displayed.

4 In the Dual T1-E1 Framers form:

Assign an available unit number to the framer.

Label the circuit.

Select Save.

The data is entered, saved, and displayed in the Dual T1-E1 Framers form.

Step Task Expected Result 9

5 In the Dual T1-E1 Framers form, select Change Member.

The Dual T1-E1 Framers change member window opens.

6 In the Dual T1-E1 Framers change member window, select T1 from the Interface Type drop-down menu for both ports. Select Save.

The data is entered, saved, and displayed in the Dual T1-E1 Framers form.

Step Task Expected Result 9

7 Navigate to the Trunks > Digital > Digital Link Descriptors form.

The Digital Link Descriptors form is displayed.

8 To create a Link Descriptor for port 1 of the framer, select Add. Port 1 will be connected to the next node.

The Digital Link Descriptors add window opens.

9 In the Digital Link Descriptors add window:

Enter a number in the Number field.

Select A from the Address for Message Control drop-down menu.

Select ISDN Node from the Integrated Digital Access drop-down menu.

Select the NT radio button for the Termination Mode.

Select Save.

The data is entered, saved, and displayed in the Digital Link Descriptors form.

Step Task Expected Result 9

10 To create a Link Descriptor for port 2 of the framer, which will be connected to the previous node, select Add.

The Digital Link Descriptors add window opens.

11 In the Digital Link Descriptors add window:

Enter a number in the Number field.

Select B from the Address for Message Control drop-down menu.

Select ISDN Node from the Integrated Digital Access drop-down menu.

Select the LT radio button for the Termination Mode.

Select Save.

The data is entered, saved, and displayed in the Digital Link Descriptors form.

Step Task Expected Result 9

12 Navigate to the Trunks > Digital > Digital Links form.

The Digital Links form is displayed.

13 Select Framer Port 1 and select Change:

Label the Link Connection Lab Y to Lab Z

Assign the first Link Descriptor you just created to Port 1.

Select Save.

The data is entered, saved, and displayed in the Digital Links form.

14 Repeat step 13 for Port 2. Label the Link Connection Lab Y to Lab X.

The data is entered, saved, and displayed in the Digital Links form.

Step Task Expected Result 9

15 Navigate to the Trunks > Digital >

MSDN/DPNSS/DASSII Trunk Circuit Descriptor form.

The MSDN-DPNSS-DASSII Trunk Circuit Descriptor form is displayed.

16 To create the first Trunk Circuit Descriptor:

Select Add.

Enter a number in the Number field.

Select Universal T1 from the Card Type drop- down menu.

Verify the Dual Seizure Priority is Incoming.

Select Local Office from the Far End Connection drop-down menu. Select Save.

The data is entered, saved, and displayed in the MSDN- DPNSS-DASSII Trunk Circuit Descriptor form.

17 To create the second Trunk Circuit Descriptor:

Select Add.

Enter a number in the Number field.

Select Universal T1 from the Card Type drop- down menu.

Verify the Dual Seizure Priority is Outgoing.

Select Local Office from the Far End Connection drop-down menu. Select Save.

The data is entered, saved, and displayed in the MSDN- DPNSS-DASSII Trunk Circuit Descriptor form.

Step Task Expected Result 9

18 Navigate to the Trunks > Trunk Attributes form. The Trunk Attributes form is displayed.

19 Select an available Trunk Service Number and select Change.

The Trunk Service Number is selected and the Trunk Attributes change window opens.

20 For Port 1 of the framer, change the following:

Enter an available COS number in the Class of Service field. The COS is programmed later.

Enter a 0 in the Dial In Trunks Incoming Digit Modification – Absorb field.

In the Trunk Label field, enter a label to identify this node goes to the next lab.

Select Save.

The data is entered, saved, and displayed in the Trunk Attributes form.

21 Repeat steps 19 and 20 for Port 2. Label it to identify this node goes to the previous lab.

The data is entered, saved, and displayed in the Trunk Attributes form.

Step Task Expected Result 9

22 Navigate to the Trunks > Digital > Digital Trunks form.

The Digital Trunks form is displayed.

23 Select an available Digital Trunk and select Change.

The Digital Trunk is selected and the Digital Trunk change window opens.

24 Select Circuit 1 and then select Change.

Enter 23 into the Number of Records to Change field.

Select the trunk number drop-down menu and select Increment. Enter the first Trunk Number in the Value to Change field. In this lab, use 1001. Enter a one in the Increment by field.

Select Change All To from the Trunk Service Number drop-down menu. Enter Port 1’s Trunk Service Number previously created in the Value to Change field.

Select Change All To from the Circuit Descriptor Number drop-down menu. Enter Port 1’s Circuit Descriptor Number previously created in the Value to Change field.

Select Change All To from the Interconnect Number drop-down menu. Enter a one in the Value to Change field.

Select Change All To from the Tenant Number drop-down menu. Enter a one in the Value to Change field.

Select Save.

The data is entered, saved, and displayed in the Digital Trunks form.

25 Repeat step 24 for Port 2. Use 1101 for the first trunk number.

Step Task Expected Result 9

26 Navigate to the Trunks > Digital > Network

Synchronization form. If the instructor designates your lab as the clock source, skip this programming.

The Network

Synchronization form is displayed.

27 Enter the PLID of any trunk on the framer that leads back towards the clock source via the fewest hops. This information is provided by the instructor or on the connection diagram.

The PLID for the clock source is entered.

28 If applicable in your classroom, program the IMAT database for the Universal NSU or for Embedded PRI/QSIG, program Protocols and Outgoing Call Characteristics according to your area. Consult the instructor.

The IMAT database is programmed.

29 Navigate to the Trunks > Digital > ISDN > ISDN Protocol form.

The ISDN Protocol form is displayed.

30 To assign a protocol to run over the T1 link on Port 1:

Select Port 1.

Select Change.

Verify the Interface Type is T1

Select QSIG from the Protocol drop-down menu.

Select the Network Side/QSIG Master check box.

Enter a label into the Comment field. Select Save.

The data is entered, saved, and displayed in the ISDN Protocol form.

31 Repeat step 30 for Port 2. Do not select the Network Side/QSIG Master check box.

The data is entered, saved, and displayed in the ISDN Protocol form.

Step Task Expected Result 9

32 Navigate to the System Properties > System Feature Settings > Class of Service Options form.

The Class of Service Options form is displayed.

33 Program the trunks’s COS that was used in the Trunk Attributes form by setting the following to Yes:

DASS II OLI/TLI Provided

Display ANI/ISDN Calling Number Only

Display ANI/DNIS/ISDN Calling/Called Number

Public Network Access Via DPNSS

Public Trunk

The COS for trunks is programmed.

34 Program the sets’ COS by setting the following to Yes:

DASS II OLI/TLI Provided

Display ANI/ISDN Calling Number Only

Display ANI/DNIS/ISDN Calling/Called Number

Public Network Access Via DPNSS

Individual Trunk Access

The COS for the sets is programmed.

35 Test your trunks using the Individual Trunk Access feature code. Enter the feature code and then the four digit trunk number. Because this is a PRI trunk you won’t hear dial tone, so just dial a four-digit DN that is valid for that lab. Refer to the classroom maps or the instructor for the DNs to dial.

Calls can be completed to and from each lab in the classroom. Errors can be caused by either end of the span.