REM CTRL
6 Adaptor kit
5.4 Receiver standard wiring
5.4.1.2 System layout ARC, DRC/ORC with one antenna + ACU
Figure 6-5, Main/Standby transceiver connected to ARC, DRC/ORC and ACU via MDF Krone Legend
Standard wiring KRONE cross wiring Signal cable RF Coaxial cable
Legend
Standard wiring KRONE cross wiring Signal cable RF Coaxial cable KRONE connector
KRONE connector
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-38 5.4.1.3 Detailed wiring diagram ARC, DRC/ORC + ACU using MDF Krone
Figure 6-6, Wiring diagram main/standby transceiver connected to ARC, DRC/ORC and ACU via MDF Krone
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-39 5.4.1.4 Setup procedure – Control using ARC, DRC/ORC, ACU
Step Description Reference
1 Install the units into sub rack and rack as desired. 4.3
2 Install standard MDF Krone wiring harness, and power to each unit 6.1.1 and 6.1.2
3 Inter-wire signals in according with the cross wiring drawing below -
4 Set Mute on transmit to enabled (receivers) – if desired 8.3.4.2
5 Set Audio input source to line (transmitters) 8.2.4.2
6 Set Audio output source to Lineout (receivers) 8.3.4.2
7 Set Keying source to include txkeygnd 8.2.4.2
8 Set Alarm config, Alarm pin pullup to Enabled (default) 8.2.4.3 and 8.3.4.3
9 Set Alarm config, Select polarity to Low (default) 8.2.4.3 and 8.3.4.3
10 Set the main transmitter and receiver Operation mode to Main 8.2.4.1 and 8.3.4.1
11 Set the backup transmitter and receiver Operation mode to Norm
(default) 8.2.4.1 and 8.3.4.1
12 Set RS485 Bitrate to 1200 b/s for transmitters and receivers 8.2.4.3 and 8.3.4.3
13 Set RS485 Address to 1 for the Main receiver, 2 for the Main transmitter, 3 for the Standby receiver and 4 for the Standby transmitter.
8.2.4.3 and 8.3.4.3
14 Set the RS485 Protocol to Legacy 8.2.4.3 and 8.3.4.3
15 Connect RF cables and antennas as illustrated in the system
layout above. Figure 6-5
16 Refer to Equipment manuals for configuration of remote units. -
Table 6.1, Set up procedure transceiver main/standby connected to ARC, DRC/ORC + ACU
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-40 5.4.2 Transceiver wiring, Main/Standby, 4Wire E&M, VCCS and ACU
Via the MDF Krone interface, it is possible to connect all required signals towards a Voice Control and Command System (VCCS). In addition an antenna changeover unit is used in this configuration to control main/standby switching manually or automatic.
• TX audio line
• TX ground keying (PTT)
• TX alarm output
• TX select input (used for main/standby switching)
• RX audio line
• RX squelch output
• RX alarm output
• RX Select input (used for main/standby switching)
• Ethernet (LAN) interface
5.4.2.1 System layout
Figure 6-7, Main/Standby transceiver connected to an ACU + VCCS via MDF Krone KRONE connector
To VCCS
Legend
Standard wiring KRONE cross wiring Signal cable RF Coaxial cable
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-41 5.4.2.2 Detailed wiring diagram transceiver + ACU using MDF Krone
Figure 6-8, Main/Standby transceiver connected to an ACU + VCCS via MDF Krone
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-42 5.4.2.3 Setup procedure, main/standby transceiver connected to an ACU + VCCS
Step Description Reference
1 Install the units into sub rack and rack as desired. 4.3
2 Install standard KRONE wiring harness, and power to each unit 6.1.1 and 6.1.2
3 Inter-wire signals in according with the cross wiring drawing below -
4 Set Mute on transmit to enabled (receivers) – if desired 8.3.4.2
5 Set Audio input source to line (transmitters) 8.2.4.2
6 Set Audio output source to Lineout (receivers) 8.3.4.2
7 Set Keying source to include txkeygnd (or other if required) 8.2.4.2
8 Set Alarm config, Alarm pin pullup to Enabled (default) 8.2.4.3 and 8.3.4.3
9 Set Alarm config, Select polarity to Low (default) 8.2.4.3 and 8.3.4.3
10 Set the main transmitter and receiver Operation mode to Norm 8.2.4.1 and 8.3.4.1
11 Set the backup transmitter and receiver Operation mode to Norm
(default) 8.2.4.1 and 8.3.4.1
12 Connect RF cables and antennas as illustrated in the system
layout above. -
13 Refer to Equipment manuals for configuration VCCS. - Table 6.2, 4Wire E&M, VCCS and ACU
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-43 5.4.3 Transceiver, Main / Standby, 4Wire +E&M, APM, ARC and DRC
This system illustrates the use of a pair of Audio and PTT modems (APM) using the MDF Krone interface. The APM gives the system the ability to transfer PTT, squelch and alarm signals as in-band tones between the radio site and the operator site.
• TX audio line
• TX ground keying (PTT)
• TX alarm output
• TX select input (used for main/standby switching)
• RX audio line
• RX squelch output
• RX alarm output
• RX Select input (used for main/standby switching)
• RS-485 remote serial bus
The following units are available from Jotron to perform the required functionality:
• ARC – Audio Remote Control. Connects to the radio using 4W audio, PTT, squelch, alarm and select signals. Gives the user the ability to transmit and receive using the remote control, in addition the user has access to main/standby switching and alarm monitoring of the units.
Maximum range for the remote control depends on the quality of the copper wires used, but is in the range 200-300 m.
• DRC – Data Remote Control. Connects to the radio using the RS-485 remote serial bus. In addition the DRC is powered by the external voltage available on either the radio units or the ARC.
Gives the user the ability to change the operating frequency and monitor certain built in test (BIT) signals in the radios.
• ORC – Operator Remote Control. Connects to the radio using the RS-485 remote serial bus. In addition the ORC is powered by the external voltage available on either the radio units or the ARC.
Gives the user the ability to change the operating frequency between pre-stored frequencies in the radio.
• APM – Audio PTT Modem. Allows the use of in-band signalling to transfer squelch, PTT and alarm signals between the operator and the radio site. In addition, the remote APM unit contains an antenna switchover relay to switch the antenna between the main and the standby radio units.
Jotron AS| TR7750: Operators handbook 4BRemote systems using IP Page 5-44 5.4.3.1 System Layout
Figure 6-9, Main/Standby transceiver using remote ARC, DRC/ORC and APMs.