7MH4 601-1AA01 Two-channel version for

In document Simatic s7 300 (Page 95-100)

SM 338 POS input module

7MH4 601-1AA01 Two-channel version for

connec-tion of two balance

7MH4 601-1BA01

Configuring package 7MH4 683-3AA63 incl. SIWATOOL parameterization

software, manual on CD-ROM and example programs SIWAREX U manual

German 7MH4 693-3AA11

English 7MH4 693-3AA21

Junction box JB 7MH4 710-1BA

for connecting together max. 4 load cells

9-conductor cable 7MH4 607-8CA to connect SIWAREX U to 9-pin

PC interface (RS 232C)

Cable LI2Y (ST) 7MH4 702-8AB

to connect SIWAREX U to junction boxes

Front connector

20-pin, with screw-type terminals

• 1 unit 6ES7 392-1AJ00-0AA0

• 100 units 6ES7 392-1AJ00-1AB0

20-pin, with spring-loaded terminals

6ES7 392-1BJ00-0AA0

Labelling strips 6ES7 392-2XX00-0AA0 10 units (spare part)

Shield connecting element 6ES7 390-5AA00-0AA0 80 mm wide, with 2 rows for

4 terminal elements each Terminal elements 2 units

For 1 cable with 4 to 13 mm diameter

6ES7 390-5CA00-0AA0

SIWAREX M

Function modules

4

Overview SIWAREX M is a weighing and

proportioning system with verification capability for max-imum accuracy requirements.

The main applications of SIWAREX M include:

• Fill level scales with verifica-tion capability

• Platform scales and vehicle scales with verification ca-pability

• Single component scales

• Multi-component scales

• Proportioning scales with verification capability

• Scales for potentially explo-sive areas (can be imple-mented by using an Ex(i) interface)

• Weight encoders for other types of scales (e.g. differ-ential proportioning scales, etc.)

Technical specifications

• Function included – Function not included Main applications

• Load measurement on cranes –

• Overload protection –

• Belt tensioning devices –

• Platform scales •

• Fill level measurement (container/bins)

• Proportioning and mixing scales •

• Scales with verification capacity • Intrinsically safe load cell

powering

Optional (Ex-l) Stand-alone (without SIMATIC)

Integration in:

• S5-90/S5-95U/S5-100U Via RS 232/TTY + CP

• S5-95U/DP (PROFIBUS master) Via RS 232/TTY + CP

• S5-115U/S5-135U/S5-155U Via ET 200M

• S7-300 Direct integration

• S7-400 via ET 200M

• PCS 7 via ET 200M

• M7-300 –

• M7-400 –

• C7 Via IM or ET 200M

• TELEPERM M (AS 388/488/TM) Via ET 200M

Communication interfaces SIMATIC S7 (P bus) RS 232, TTY Process interfaces

• Digital inputs 3 (assignable)

• Digital outputs 4 (assignable)

• Pulse input –

• Analog output/analog input •/–

Remote display connection (via serial interface)

• (with verification capability) gross/net/setpoint

remote display with operator control

Printer connection • (verification capability)

Measuring properties

Class III EU type approval for com-mercial scales (with verification capability)

6000 d

Accuracy (definition acc. to mea-suring technology)

0.01%

nIND acc. to EN 45 501

min. measuring signal ∆umin pro d (*) no verification capability

6000 0.5 µV Internal resolution ± 524,288 Data format for weight values 4 byte (fixed point) No. of measurements/second 50

Filters Exponent filter: 0.05 to 5 Hz Mean value filter

Scale functions

• Weight values Gross/net/tare

• Limit 4 (min/max/empty/overfill)

• Scale standstill •

• Zero setting function Via command and automatically Proportioning functions

• Control of coarse/fine flow valves •

• Tolerance monitoring •

• Material flow monitoring •

• Automatic proportioning optimiza-tion

• Automatic reproportioning •

• Inching mode •

Integral display and operator panel

Module parameterization Via SIMATIC S5/S7/C7 or SIWATOOL M PC parameteriza-tion software

UL/CSA/FM approval Yes

IP degree of protection to DIN EN 60 529; IEC 60 529

In S7 frame: IP 20 Stand-alone: IP 10

Function modules

SIWAREX M

4

Technical specifications (continued)

1) Up to 1000 m, depending on the gas group.

2) Serial printer, ANSI-, EPSON-, IBM-compatible

Ordering data Order No. Order No.

• Load cell supply

• Supply voltage Us (rated value) 10.2 V DC

• Max. supply current ≤ 180 mA

• Permissible load resistance:

- RLmin > 60 Ω single-channel

- RLmax < 4010Ω

with Ex(i) interface:

- RLmin > 87Ω

- RLmax < 4010Ω

Permissible load cell characteris-tics

Up to 4 m V/V Perm. range of measurement

sig-nal (with largest characteristic value set)

-41.5 to 41.5 mV

Max. distance of load cells 1000 m 300 m in Ex area1) Voltage supply DC 24 V

• Rated voltage 24 V DC

• Max. current consumption 300 mA Voltage supply from backplane bus Typ. 50 mA Serial interface 1 RS 232:

• Transmission rate 2400/9600 bps

• Parity Even/odd

• No. of data bit / stop bit 8/1

• Signal level In acc. with EIA-RS 232

• Protocols SIWAREX-Protokoll

3964R, XON/XOFF (printer) 2) Serial interface 2 TTY:

• Transmission rate 9600 bps

• Parity Even

• No. of data bit / stop bit 8/1

Serial interface 2 TTY:

• Signal level Active/passive (floating)

• Protocols Remote display protocol

SIWAREX protocol 3964R

Binary inputs Number:3

rated voltage: 24 V switching frequency: 10 Hz Binary outputs Number: 4 (digital)

rated voltage: 24 V rated current: 0.5 A total max.: 1 A isolation: 500 V Analog output

• Output range 0/4 to 20 mA

• Total error at 25 °C 0.15%

• Update rate Approx. 350 ms

• Resolution 16 bit (0-20 mA)

• Burden including line resistance ≤ 600 Ω Climatic requirements

Tmin(IND) to Tmax(IND) (opperating temperature)

Vertical installation: -10 to +60 °C horizontal installation/with verifi-cation-capability: -10 to +40 °C EMC requirements in accordance

with

NAMUR NE21, Part 1 90/384/EWG 89/386/EWG MTBF (SN 29500) 172 000 h at +40°C

SIWAREX M weighing module 7MH4 553-1AA41 with verification capability

Configuring package 7MH4 583-3FA63 incl. SIWATOOL parameterization

software, manual on CD-ROM and example programs SIWAREX M manual

German 7MH4 593-3AA11

English 7MH4 593-3AA21

Junction box JB 7MH4 710-1BA

for connecting max. 4 load cells 9-conductor cable

to connect SIWAREX M to 9-pin PC interface (RS 232C)

2 m 7MH4 702-8CA

5 m 7MH4 702-8CB

Cable LI2Y (ST) 7MH4 702-8AB

to connect SIWAREX M to junction boxes

Front connector

20-pin, with screw-type terminals

• 1 unit 6ES7 392-1AJ00-0AA0

• 100 units 6ES7 392-1AJ00-1AB0

20-pin, with spring-loaded terminals

6ES7 392-1BJ00-0AA0

Labelling strips 6ES7 392-2XX00-0AA0 10 units (spare part)

Shield connecting element 6ES7 390-5AA00-0AA0 80 mm wide, with 2 rows for

4 terminal elements each Terminal elements 2 units

For 1 cable with 4 to 13 mm diameter

6ES7 390-5CA00-0AA0

SIWAREX A

Function modules

4

Overview SIWAREX A is a weighing and

proportioning system with verification capability for max-imum accuracy requirements and fast processes. The main applications of SIWAREX A in-clude:

• Filling plants

• Bagging scales

• Single component scales

• Multi-component scales

• Filling scales with verifica-tion capability

• Scales for potentially explo-sive areas (can be imple-mented by using an Ex(i) interface).

Technical specifications

• Function included – Function not included Main applications

• Load measurement on cranes –

• Overload protection –

• Belt tensioning devices –

• Platform scales –

• Fill level measurement (containers/bins)

• Propoortioning and mixing scales •

• Scales with verification capability • Intrinsically-safe load cell

powering

Optional (Ex-l) Stand-alone (without SIMATIC)

Integration in

• S5-90/-95U/-100U –

• S5-95U/DP (PROFIBUS-master) –

• S5-115U/-135U/-155U –

• S7-300 Direct integration

• S7-400 Via ET 200M

• PCS 7 –

• M7-300 –

• M7-400 –

• C7 Via IM or ET 200M

• TELEPERM M (AS 388/488/TM) –

Communication interfaces SIMATIC S7 (P-Bus) RS 232, TTY Process interfaces

• Digital input 3

• Digital output 4

• Pulse input –

• Analog output/analog input •/–

Remote display connection (via serial interface)

• (verification capability) Gross/net

Printer connection • (verification capability) Measuring properties

Class III EU type approval for com-mercial scales (with verification capability)

6000 d (2 x 6000 d)

Accuracy (definition in acc. with measuring technology)

0.01%

nIND in acc. with EN 45 501 Min. measuring signal umin pro d (*) no verification capability

6000 0.5 µV

Internal resolution 1,048,576

Data format for weight values 4 byte (fixed point) No. of measurements/second 50

Filters Mean value filter, 4 stages Scale functions

• Weight values Gross/net

• Limits –

• Scales standstill •

• Zero setting function Via command or automatically Proportioning functions

• Control of coarse/fine flow valves •

• Tolerance monitoring •

• Material flow monitoring •

• Autom. proportioning optimization •

• Automatic reproportioning •

• Inching mode •

Integral display and operator panel

Module parameterization Via SIMATIC S7 or SIWATOOL A PC-parameterization software

UL/CSA/FM approval

IP degree of protection to DIN EN 60 529; IEC 60 529

In S7 frame: IP 20 Stand-alone: IP 10 Load cell supply

• Supply voltage Us (rated value) 10.2 V DC

• Max. supply current ≤ 180 mA Permiss. load resistance:

- RLmin > 60Ω

- RLmax < 4010Ω

With Ex(i) interface:

- RLmin > 87Ω

- RLmax < 4010Ω

Function modules

SIWAREX A

4

Technical specifications (continued)

1) Up to 1000 m, depending on the gas group.

2) Serial printer, ANSI-, EPSON-, IBM-compatible

Ordering data Order No. Order No.

Main application

Perm. load cell characteristic Up to 4 mV/V Perm. range of measurement

sig-nal (with largest characteristic value set)

-1.5 to +41.5 mV

Max. distance of load cells 1000 m

300 m in Ex area1) Voltage supply 24 V DC

• Rated voltage 24 V DC

• Max. current consumption 300 mA Voltage supply from backplane bus Typ. 50 mA Serial interface 1 RS 232:

• Transmission rate 2400/9600 Baud

• Parity Even/odd

• No. of data bit / stop bit 8/1

• Signal level In acc. with EIA-RS 232

• Protocol SIWAREX protocol

XON/XOFF (printer)2) Serial interface 2 TTY:

• Transmission rate 9600 bps

• Parity Even

• No. of data bit / stop bit 8/1

• Signal level Active/passive (floating)

• Protocol Remote display protocol

SIWAREX protocol

Binary inputs Number:3

Rated voltage: 24 V Switching frequency: 10 Hz Binary outputs Number: 4 (digital)

Rated voltage: 24 V Rated current: 0.5 A Total max.: 1 A Isolation: 500 V Analog output

• Output range 0/4-20 mA

• Total error at 25 °C 0.15%

• Update rate Approx. 350 ms

• Resolution 16 bit (0-20 mA)

• Burden including line resistance ≤ 600 Ω Climatic requirements

Tmin(IND) to Tmax(IND) (operating temperature)

vertical installation: -10 to +60 °C horizontal installation/

with verification capability: -10 to +40 °C

EMC requirements in accordance with

NAMUR NE21, Part 1 90/384/EWG 89/386/EWG MTBF (SN 29500) > 172 000 h at +40°C

SIWAREX A weighing module 7MH4 421-1AA01 with verification capability, for

maximum accuracy and fast pro-cesses

Configuring package 7MH4 483-3DA63 incl. SIWATOOL parameterization

software, manual on CD-ROM and example programs SIWAREX M manual

German 7MH4 593-3AA11

English 7MH4 593-3AA21

Junction box JB 7MH4 710-1BA

for connecting together max.

4 load cells 9-conductor cable

to connect SIWAREX A to 9-pin PC interface (RS 232C)

2 m 7MH4 702-8CA

5 m 7MH4 702-8CB

Cable LI2Y (ST) 7MH4 702-8AB

to connect SIWAREX M to junction boxes

Front connector

20-pin, with screw-type terminals

• 1 unit 6ES7 392-1AJ00-0AA0

• 100 units 6ES7 392-1AJ00-1AB0

20-pin, with spring-loaded terminals

6ES7 392-1BJ00-0AA0

Labelling strips 6ES7 392-2XX00-0AA0 10 units (spare part)

Shield connecting element 6ES7 390-5AA00-0AA0 80 mm wide, with 2 rows for

4 terminal elements each Terminal elements 2 units

For 1 cable with 4 to 13 mm diameter

6ES7 390-5CA00-0AA0

SM 374 simulator