PAGE INTENTIONALLY LEFT BLANK
NOTE: ENSURE THE BOTTOM OF THE TOUCH PANEL IS ABOVE THE BOTTOM OF
THE FREEZER SPOUT.
5. Remove the Color Touch Panel and Touch Panel Plate from the rest of the bracket assembly. Secure the Freezer Plate to the freezer using the four self-drill screws provided, using the marks you made as a guide. Install a screw into each long slot at each end for maximum stability.
26126
6. Reinstall the rest of the Color Touch Panel and Plate to the bracket assembly and tighten the nuts when the panel is in the desired position.
26127
7. If you wish to adjust the angle of the Color Touch Panel, loosen the two nuts of the Touch Panel Plate’s hinge to angle the panel toward and away from the spout.
Loosen the three nuts of the Connector Plate to rotate the panel upwards or downwards. Tighten the nuts to secure the assembly into the desired position.
26128
26129
Mounting the Tube / Cable Casing Assemblies
The CTP 80FCB includes a metal cable casing assembly to house and hold the 9-Tube
Assembly level with the Blending Assembly.
Other cables, such as the ethernet cable, can also be hidden in this assembly, or the plastic one as explained in the next section.
DO NOT install the Casing on a side of the freezer with out-take vents. The heat from these vents can warm the syrup tubes, melting product more quickly when a serving is drawn.
The following illustrations show a left side mounting. However, right side mounting is also acceptable as long as no vents producing heat interfere. The Touch Panel cable Casing should be installed on the same side the cable exits the assembly.
1. The Casing Assembly contains very power magnets to attach to the side of the freezer.
Simply place the assembly in line with the Door Spout Assembly with the hinged surface down (holding screw at the top).
The curved ends of the Casing should hang over the front and back of the freezer and the assembly should be level horizontally.
26461
2. Remove the screw from the top of the Casing Assembly.
26462
3. Swing the Casing cover outward.
26463
4. Carefully place the 9-Tube Assembly tubes inside the Casing. Pull excess tubing to the back of the freezer, allowing enough slack in the front to curve around to the spout.
26464
5. Close the casing without pinching the lines.
26465
6. Install the screw to secure the Casing.
26466
Mounting the Plastic Casing Assembly When possible, include all cables and tubes inside the metal Casing Assembly. The smaller plastic Touch Panel Cable Casing is included to hide cables that don’t reach or aren’t hidden by the metal casing.
1. Find an area on the freezer to install the plastic casing where it will minimize the appearance of the cables. Clean the area where the plastic casing will be installed.
Detergent CLEAN
Water RINSE
DRY
26467a
2. Remove the protective tape from the casing and apply the casing to the cleaned area of the freezer.
26467b
3. Open the casing and insert the cable(s).
Close the casing to finish the assembly.
26467c
Connecting the Unit Syrup Line
The syrup lines attached at the lower back of the cabinet connect the eight bags of syrup to the Blending Assembly, with the ninth tube connecting the Sanitizer Tank to the Blending Assembly.
1. Locate the 9-Tube Lead at the back of the cabinet. Remove the dust cap and slide the coupler casing toward the unit to expose the lead line coupler.
2. Connect the 9-Tube Lead with the 9-Tube Assembly, with the 9-hole gasket in between. Align the 9-hole gasket with the coupler pins of the 9-Tube Lead and place the gasket against the coupler. Then align the coupler pins of the two tube assemblies and connect them.
9-HOLE GASKET
COUPLER PINS
26431
3. Slide the coupler casing over the connection and screw each coupler nut into each end of the casing. Tighten the coupler nuts to secure the connection.
Installing & Filling the Sanitizer Tank Use only NSF approved sanitizer solution mixed according to the manufacturer’s instructions in the Sanitizer Tank. The tank system delivers solution to specific areas of the Flavor Burst® system such as the syrup lines during certain functions. In order to utilize these clean-in-place functions, keep an
adequate supply of approved sanitizer solution in the Sanitizer Tank at all times.
The Sanitizer Tank should be checked on a daily basis. For proper sanitation, keep only FRESH sanitizer solution in the tank. Some sanitizer solutions may become ineffective after a few days and may not clear the system of all bacteria present. See the sanitizer
manufacturer’s information for potency and longevity. Replace older solution with fresh solution when necessary. Additionally, use hot water when mixing the sanitizer solution, as it will be much more effective in cleaning the system.
1. Prepare approximately 3 gallons (11.5 Liters) of approved sanitizer solution according to manufacturer’s instructions.
2. Insert one end of the sanitizer tube into the fitting located at the lower back of the cabinet.
3. Insert the other end of the sanitizer tube into the fitting on the Sanitizer Tank.
4. Remove the hand pump from the Sanitizer Tank and fill the Tank with approved sanitizer solution.
NOTE: USE THE REMAINING SANITIZER SOLUTION FOR MANUAL SANITIZING IN THE CLEAN-IN-PLACE PROCEDURE, DAILY OPENING PROCEDURES, OR DAILY
CLOSING PROCEDURES.
5. Reinstall the hand pump and tighten
sufficiently. Using the handle, pump air into the Sanitizer Tank to prime the pump (approximately 10 strokes.)
26244
NOTE: NO PRESSURE IS NEEDED IN THE TANK DURING NORMAL OPERATIONS.
Power Connections and Power Up
The electrical connections for the CTP 80FCB are located on the upper back panel of the unit.
Once the cables have been attached and the unit is turned on, the CTP 80FCB can remain on during normal operations from day to day. It does not need to be turned off unless it is being serviced or moved, or unless it is not used for a long period of time.
NOTE: ELELCTRICAL HAZARD - DO NOT