• No results found

Parameter Reference

The following tables provide parameter ranges and default values involved in getting the UE into Idle Mode, Establishing a Call and Maintaining Mobility and Connectivity. They are listed in the same order they were presented. The Level column indicates the network element that owns the parameter. The class column indicates if the parameter is set based on Policy (must be set this way), Rule (must be set this way with exceptions), Fixed (recommended to be set this way) and Variable (set at your discretion).

Table 20: Configurable Parameter Lookup Table

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

Basic Design Requirements

uarfcnDl See section 4.1.2 N/A N/A Cell Variable Integer uarfcnUl See section 4.1.2 N/A N/A Cell Variable Integer

supportOf16qam 0=FALSE, 1=TRUE 0=FALSE 1=TRUE Cell Fixed Integer primaryScramblingCode 0 to 511 N/A 0 to 511 Cell Variable Integer

primaryCpichPower -100 to +500 300 300 Cell Fixed 0.1dBm Idle Mode

primarySchPower -350 to +150 -18 -18 Cell Fixed 0.1dB secondarySchPower -350 to +150 -35 -35 Cell Fixed 0.1dB bchPower -350 to +150 -31 -31 Cell Fixed 0.1dB

noOfMibValueTagRetrans 0 to 10 0 0 RNC Fixed Retransmissions sib1PLMNScopeValueTag 0 to 31 N/A 0 to 31 Cell Variable Integer

mcc 0 to 999 1 310 RNC Fixed Integer

mnc 0 to 999 N/A 410 RNC Fixed Integer

sib1StartPos 0 to 4094 4 4 RNC Fixed Frames

sib1RepPeriod 4, 8, 16 to 4096 32 32 RNC Fixed Frames

sib3StartPos 0 to 4094 2 2 RNC Fixed Frames

sib3RepPeriod 4, 8, 16 to 4096 16 16 RNC Fixed Frames

sib5StartPos 0 to 4094 6 6 RNC Fixed Frames

sib5RepPeriod 4, 8, 16 to 4096 32 32 RNC Fixed Frames

sib7StartPos 0 to 4094 2 2 RNC Fixed Frames

sib7RepPeriod 4, 8, 16 to 4096 16 16 RNC Fixed Frames sib7expirationTimeFactor 1, 2, 4, 8 to 256 1 1 RNC Fixed Factor sib11StartPos 0 to 4094 20 20 RNC Fixed Frames sib11RepPeriod 4, 8, 16 to 4096 128 128 RNC Fixed Frames

Parameter Range Ericsson Default AT&T Recommended Level Class Unit sib12StartPos 0 to 4094 14 14 RNC Fixed Frames sib12RepPeriod 4, 8, 16 to 4096 32 32 RNC Fixed Frames

nmo Mode 1 or 2 2 2 RA Fixed Integer

cellReserved RESERVED or NOT_RESERVED NOT_RESERVED NOT_RESERVED Cell Variable String accessClassNbarred 0 to 65535 0 0 Cell Fixed Integer

qRxLevMin -115 to -25 -115 -115 Cell Fixed dBm

maxTxPowerUl -50 to +33 24 24 Cell Fixed dBm

qQualMin -24 to 0 -18 -19 Cell Fixed dB

att 0=FALSE, 1=TRUE 1=TRUE 1=TRUE LA Fixed Integer

aichPower -22 to +5 -6 -6 Cell Fixed dB

ConstantValueCprach -35 to -10 -27 -27 Cell Fixed dB

powerOffsetP0 1 to 8 3 2 Cell Fixed dB

preambleRetransMax 1 to 64 8 15 Cell Fixed Preambles maxPreambleCycle 1 to 32 4 3 Cell Fixed Cycles

powerOffsetPpm -5 to +10 -4 0 Cell Fixed dB

dlInitSirTarget -82 to 173 41 41 RNC Fixed 0.1dB

cBackOff -60 to +60 0 0 RNC Fixed 0.25dB

ecNoPcpichDefault -20 to -10 -16 -16 RNC Fixed dB

pO2 0 to 24 12 12 RNC Fixed 0.25dB

pcpichPowerDefault 0 to 50 33 33 RNC Fixed dBm ulInitSirTargetSrb -82 to 173 57 57 RNC Fixed 0.1dB ulInitSirTargetLow -82 to 173 49 49 RNC Fixed 0.1dB ulInitSirTargetHigh -82 to 173 82 82 RNC Fixed 0.1dB ulInitSirTargetExtraHigh -82 to 173 92 92 RNC Fixed 0.1dB

cPO -30 to 30 0 0 RNC Fixed 0.1dB

lAC 1 to 65533, 65535 N/A N/A LA Variable Integer

rAC 0 to 255 N/A N/A RNC Variable Integer

t3212 0 to 255 10 10 LA Fixed 6minutes

multiRabSp0Available 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary multiRabUdi8Available 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary psStreaming128 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary allow384HsRab 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

pchPower -350 to 150 -4 -4 RNC Fixed 0.1dB

cnDrxCycleLengthCs 6 to 9 6=640 7=1280 RNC Fixed coeff cnDrxCycleLengthPs 6 to 9 7=1280 7=1280 RNC Fixed coeff utranDrxCycleLength 3 to 9 5=320 5=320 RNC Fixed coeff noOfPagingRecordTransm 1 to 5 2 2 RNC Fixed Integer noOfMaxDrxCycles 1 to 10 1 1 RNC Fixed DRX cycles

Admission Control

hsdpaUsersAdm 0 to 1000 10 10 Cell Var. Users maxNumHsdpaUsers 1 to 32 16 16 Cell Var. Users compModeAdm 0 to 128 15 15 Cell Var. Radio Links eulServingCellUsersAdm 0 to 100 32 4 Cell Fixed E-DCH users eulNonServingCellUsersAdm 0 to 100 100 10 Cell Fixed E-DCH users

dlCodeAdm 0 to 100 80 70 Cell Var. %

beMarginDlCode 0 to 20 1 1 Cell Var. 5%

sf8Adm 0 to 8 8 8 Cell Fixed Radio Links

sf16Adm 0 to 16 16 16 Cell Var. Radio Links

sf32Adm 0 to 32 32 32 Cell Var. Radio Links

sf16gAdm 0 to 16 16 16 Cell Var. Radio Links

sf16AdmUl 0 to 50 16 50 Cell Var. Radio Links

sf8AdmUl 0 to 50 8 8 Cell Var. Radio Links

sf4AdmUl 0 to 1000 0 6 Cell Var. Radio Links

pwrAdm 0 to 100 75 75 Cell Var. %

maximumTransmissionPower 0 to 500 400 400 Cell Var. 0.1dBm

beMarginDlPwr 0 to 100 10 10 Cell Var. %

pwrAdmOffset 0 to 100 10 10 Cell Var. %

aseUlAdm 0 to 500 160 500 Cell Var. ASE

beMarginAseUl 0 to 500 20 0 Cell Var. ASE

aseUlAdmOffset 0 to 500 40 40 Cell Var. ASE

aseDlAdm 0 to 500 240 500 Cell Var. ASE

beMarginAseDl 0 to 500 100 0 Cell Var. ASE

ulHwAdm 0 to 100 100 80 Site Var. %

beMarginUlHw 0 to 100 0 0 Site Var. %

dlHwAdm 0 to 100 100 100 Site Var. %

beMarginDlHw 0 to 100 0 0 Site Var. %

Parameter Range Ericsson Default AT&T Recommended Level Class Unit Call Establishment Related

emergencyCallRedirect 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary ulPathlossCheckEnabled TRUE or FALSE FALSE FALSE Cell Var. String

sf4UlPathlossThreshold 15 to 170 170 170 Cell Var. dB

loadSharingDirRetryEnabled 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary loadSharingGsmThreshold 0 to 100 75 100 Cell Fixed %

loadSharingGsmFraction 0 to 100 100 100 Cell Fixed %

directedRetryTarget 2G Neighbor N/A N/A Cell Var. N/A

loadSharingRrcEnabled 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary

loadSharingMargin 0 to 100 0 0 Cell Fixed %

loadSharingCandidate 3G Neighbor N/A N/A Nabr Var. N/A hsOnlyBestCell 0=FALSE, 1=TRUE 1=TRUE 1=TRUE RNC Fixed Binary

packetEstMode 0, 1 or 2 1 1 RNC Fixed Integer

activeQueueMgmt 0=OFF, 1=ON 0=OFF 0=OFF RNC Fixed Binary Cell Reselection

sIntraSearch 0=Continually, 1 to 27 0 22=10 Cell Fixed dB sInterSearch 0=Continually, 1 to 27 0 0 Cell Fixed dB

sRatSearch -32 to 20 4 4 Cell Fixed dB

sHcsRat -105 to 91 -105 -105 Cell Fixed dB

interFreqFddMeasIndicator 0=FALSE, 1=TRUE 0=FALSE 0=FALSE Cell Fixed Binary fachMeasOccaCycLenCoeff 0 to 12 0 4 Cell Fixed Integer

qualMeasQuantity 1=CPICH_RSCP or 2=CPICH_EC_NO 2=CPICH_EC_NO 2=CPICH_EC_NO Cell Fixed String

qHyst1 0 to 40 4 2 Cell Fixed dB

qHyst2 0 to 40 4 2 Cell Fixed dB

qOffset1sn(UtranRelation) -50 to 50 0 0 Nabr Fixed dB qOffset1sn(GsmRelation) -50 to 50 7 7 Nabr Fixed dB

qOffset2sn -50 to 50 0 0 Nabr Fixed dB

treSelection 0 to 31 2 1 Cell Fixed seconds

Intra-Frequency Handover

reportingRange1a 0 to 29 6 6 RNC Fixed 0.5dB

hysteresis1a 0 to 15 0 0 RNC Fixed 0.5dB

timeToTrigger1a 0 to 15 11=320 11=320 RNC Fixed ms

Parameter Range Ericsson Default AT&T Recommended Level Class Unit reportingInterval1a 0 to 16 3=1 3=1 RNC Fixed seconds measQuantity1 1=CPICH_RSCP or 2=CPICH_EC_NO 2=CPICH_EC_NO 2=CPICH_EC_NO Cell Fixed String reportingRange1b 0 to 29 10 10 RNC Fixed 0.5dB

hysteresis1b 0 to 15 0 0 RNC Fixed 0.5dB

timeToTrigger1b 0 to 15 12=640 12=640 RNC Fixed ms

hysteresis1c 0 to 15 2 2 RNC Fixed 0.5dB

timeToTrigger1c 0 to 15 11=320 11=320 RNC Fixed ms reportingInterval1c 0 to 16 3=1 3=1 RNC Fixed seconds

hysteresis1d 0 to 15 15 15 RNC Fixed 0.5dB

timeToTrigger1d 0 to 15 14=2560 14=2560 RNC Fixed ms filterCoefficient1 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff individualOffset(UtranCell) -10 to 10 0 0 Cell Fixed 0.5dB

w1a 0 to 20 0 0 RNC Fixed 0.1unit

w1b 0 to 20 0 0 RNC Fixed 0.1unit

Inter-Frequency and Inter-RAT Handover

usedFreqThresh2dEcno(hho) -24 to 0 -12 -12 Cell Fixed dB

hysteresis2d 0 to 29 0 4 RNC Fixed 0.5 dB

timeToTrigger2dEcno Various 320 320 RNC Fixed ms

usedFreqThresh2dRscp(hho) -115 to -25 -97 -106 ±4 Cell Fixed dBm

timeToTrigger2dRscp Various 320 320 RNC Fixed ms

usedFreqThresh2dEcno(sho) -24 to 0 -12 -15 Cell Fixed dB usedFreqThresh2dRscp(sho) -115 to -25 -97 -112 Cell Fixed dBm usedFreqThresh2dEcnoDrnc -24 to 0 -12 -12 RNC Fixed dB usedFreqThresh2dRscpDrnc -115 to -25 -97 -106 RNC Fixed dBm usedFreqRelThresh2fEcno 0 to 20 1 2 RNC Fixed dB

hysteresis2f 0 to 29 0 2 RNC Fixed 0.5dB

timeToTrigger2fEcno Various 1280 640 RNC Fixed ms

usedFreqRelThresh2fRscp 0 to 20 3 6 RNC Fixed dB

txPowerConnQualMonEnabled 0=FALSE, 1=TRUE 1=TRUE 0=FALSE RNC Fixed Binary

timeToTrigger6d Various 320 320 RNC Fixed ms

ueTxPowerThresh6b -50 to 33 18 21 RNC Fixed dB

timeTrigg6b Various 1280 1280 RNC Fixed ms

filterCoefficient2 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff filterCoeff6 0. to 9, 11, 13, 15, 17, 19 19 3 RNC Fixed coeff

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

usedFreqW2d 0 to 20 0 10 RNC Fixed 0.1unit

usedFreqW2f 0 to 20 0 10 RNC Fixed 0.1unit

FddIfHoSupp 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary FddGsmHoSupp 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hoType 0=IFHO, 1=GSM, 2=NONE 1 1=GSM_PREFERRED Cell Fixed String

defaultHoType 0=IFHO, 1=GSM, 2=NONE 1 1=GSM_PREFERRED Cell Fixed String utranRelThresh3aEcno -10 to 10 -1 2 RNC Fixed dB

hysteresis3a 0 to 15 0 4 RNC Fixed 0.5dB

gsmThresh3a -115 to 0 -102 -98 RNC Fixed dBm

timeToTrigger3a 0 to 15 6=100 6=100 RNC Fixed ms utranRelThresh3aRscp -20 to 20 -3 7 RNC Fixed dB gsmFilterCoefficient3 0. to 9, 11, 13, 15, 17, 19 1 1 RNC Fixed coeff utranFilterCoefficient3 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff

utranW3a 0 to 20 0 10 RNC Fixed 0.1unit

utranRelThreshRscp 0 to 40 5 5 RNC Fixed dB

usedFreqRelThresh4_2bEcno -10 to 10 -1 -1 RNC Fixed dB

hyst4_2b 0 to 75 10 10 RNC Fixed 0.1dB

nonUsedFreqThresh4_2bEcno -24 to 0 -11 -13 RNC Fixed dB nonUsedFreqThresh4_2bRscp -115 to 25 -94 -105 RNC Fixed dBm timeTrigg4_2b 0, 10, 20,40, 60, 80, 100, 120, 160, 200,

240, 320, 640, 1280, 2560, 5000 100 100 RNC Fixed ms UsedFreqRelThresh4_2bRscp -20 to 20 -3 -3 RNC Fixed dB

timeToTrigger2fRscp Various 1280 640 RNC Fixed ms

filterCoeff4_2b 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff usedFreqW4_2b 0. to 9, 11, 13, 15, 17, 19 0 0 RNC Fixed coeff nonUsedFreqW4_2b 0. to 9, 11, 13, 15, 17, 19 0 0 RNC Fixed coeff

HS Cell Change

hsQualityEstimate 0=CPICH_EC_NO, 1=CPICH_RSCP 1=RSCP 1=RSCP RNC Fixed Binary

hsHysteresis1d 0 to 75 10 10 RNC Fixed 0.1dB

hsTimeToTrigger1d Various 640 640 RNC Fixed ms

hsCellChangeAllowed 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hsToDchTrigger(changeOfBestCellIntraRnc) 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hsToDchTrigger(servHsChangeIntraRnc) 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary

Parameter Range Ericsson Default AT&T Recommended Level Class Unit hsToDchTrigger(poorQualityDetected) 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary Channel Switching

downswitchThreshold 0 to 32 0 0 RNC Fixed 1kbit/s downswitchTimer 0 to 1000 10 100 RNC Fixed 100ms downswitchTimerThreshold 0 to 64 0 0 RNC Fixed 1kbit/s hsdschInactivityTimer 1 to 255 2 10 RNC Fixed seconds

ulRlcBufUpswitch Various 256 256 RNC Fixed bytes

dlRlcBufUpswitch 0 to 2000 500 500 RNC Fixed bytes

inactivityTimer 1 to 1440 120 10 RNC Fixed seconds

inactivityTimerPch 1 to 240 30 30 RNC Fixed minutes dlDownswitchBandwidthMargin 0 to 100 0 80 RNC Fixed % dlThroughputDownswitchTimer 0 to 2000 20 20 RNC Fixed 100ms ulDownswitchBandwidthMargin 0 to 100 0 80 RNC Fixed % ulThroughputDownswitchTimer 0 to 2000 20 20 RNC Fixed 100ms

bandwidthMargin 0 to 100 90 90 RNC Fixed %

upswitchTimer 0 to 100 5 5 RNC Fixed 100ms

dlThroughputAllowUpswitchThreshold 0 to 100 0 0 RNC Fixed % downswitchPwrMargin 0 to 20 2 2 RNC Fixed 0.5dB

coverageTimer 0 to 100 10 10 RNC Fixed 100ms

upswitchPwrMargin 0 to 20 6 6 RNC Fixed 0.5dB

bandwidthMarginUl 0 to 100 0 90 RNC Fixed %

upswitchTimerUl 0 to 100 5 1 RNC Fixed 100ms

ulThroughputAllowUpswitchThreshold 0 to 100 0 90 RNC Fixed %

reportHysteresis 0 to 20 6 6 RNC Fixed 0.5dB

downswitchTimerSp 0 to 180 2 2 RNC Fixed 0.5seconds

ulRlcBufUpswitchMrab Various 8 8 RNC Fixed bytes

dlRlcBufUpswitchMrab 0 to 20 0 8 RNC Fixed 100bytes inactivityTimeMultiPsInteractive 0 to 10000 50 50 RNC Fixed 100ms queueSelectAlgorithm 1 to 6 1 3 Cell Fixed Integer airRateTypeSelector 0=ACKNOLEDGED or

1=TRANSMITTED 1=TRANSMITTED 1=TRANSMITTED Cell Fixed Integer HSDPA Scheduling

eulTargetRate 0 to 6016 128 128 Cell Fixed 1kbit/s eulNoReschUsers 0 to 32 5 5 Cell Fixed E-DCH users eulMaxNoSchEdch 0 to 100 100 16 Cell Fixed E-DCH users

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

eulNoErgchGroups 1. to 4 4 4 Cell Fixed E-RGCH groups eulMaxShoRate 0 to 1472 128 1472 Cell Fixed 1kbit/s

eulReservedHwBandwidthSchedDataNonServCell 1 to 1472 128 128 Cell Fixed 1kbit/s

eulThermalLevelPrior -1150 to -600 -1040 -1040 Cell Fixed 0.1dBm eulSlidingWindowTime 10 to 864000 1800 1800 Cell Fixed seconds eulMinMarginCoverage 0 to 1.0 10 10 Cell Fixed -

eulNoiseFloorLock 0=FALSE, 1=TRUE 0=FALSE 0=FALSE Cell Fixed - eulOptimalNoisefloorEstimate -1150 to -600 or -1 -1040 -1040 Cell Fixed 0.1dBm

eulMaxRotCoverage 0 to 550 100 100 Cell Fixed 0.1dB eulMaxOwnUuLoad 0 to 550 30 80 Cell Fixed 0.1dB harqTransmUlTti10Max 1 to 8 4 4 Cell Fixed attempts Congestion Detection and Resolution

pwrOffset 0 to 100 5 5 Cell Fixed %

pwrHyst 0 to 60000 300 300 Cell Fixed ms

iFCong 0 to 621 621 621 Cell Fixed 0.1dBm

iFOffset 0 to 621 0 0 Cell Fixed 0.1dB

iFHyst 0 to 6000 6000 6000 Cell Fixed 10ms

releaseAseDlNg 0 to 500 3 3 Cell Fixed ASE

tmInitialGhs 10 to 100000 500 500 Cell Fixed ms tmInitialG 10 to 100000 3000 3000 Cell Fixed ms tmCongActionNg 500 to 100000 800 800 Cell Fixed ms releaseAseDlGhs 0 to 5000 0 0 Cell Fixed 0.ASE tmCongActionGhs 10 to 100000 300 300 Cell Fixed ms

releaseAseDl 0 to 500 1 1 Cell Fixed ASE

tmCongAction 300 to 100000 2000 2000 Cell Fixed ms Radio Connection Supervision

cchWaitCuT 0 to 200 9 9 RNC Fixed 5minutes

t305 0 to 7 3=30 3=30 RNC Fixed minutes

nOutSyncInd 1 to 256 10 10 Cell Fixed frames

rlFailureT 0 to 255 10 10 Cell Fixed 0.1seconds

nInSyncInd 1 to 256 3 3 Cell Fixed frames

dchRcLostT 0 to 100 50 50 RNC Fixed 0.1seconds

Parameter Range Ericsson Default AT&T Recommended Level Class Unit Power and Code Control

maxFach1Power -350 to 150 18 18 Cell Fixed 0.1dB maxFach2Power -350 to 150 15 15 Cell Fixed 0.1dB

pOffset1Fach 0 to 24 0 0 Cell Fixed 0.1dB

pOffset3Fach 0 to 24 0 0 Cell Fixed 0.1dB

pO1 0 to 24 0 0 RNC Fixed 0.25dB

pO3 0 to 24 12 12 RNC Fixed 0.25dB

minPwrRl -350 to 150 -150 -150 Cell Fixed 0.1dB minimumRate 0 to 1600000 1590 1590 Cell Fixed 10bps

minPwrMax -350 to 150 0 0 Cell Fixed 0.1dB

interRate 0 to 1600000 7760 7760 Cell Fixed 10bps interPwrMax -350 to 150 38 38 Cell Fixed 0.1dB maxRate 0 to 1600000 40690 40690 Cell Fixed 10bps

maxPwrMax -350 to 150 48 48 Cell Fixed 0.1dB

initShoPowerParam -20 to 20 -2 -2 RNC Fixed 1dB

cNbifho -50 to 150 10 10 RNC Fixed 0.1dB

dlPcMethod 1 to 4 3=BALANCING 3=BALANCING RNC Fixed Integer

fixedPowerDl 1 to 101 65 65 RNC Fixed 0.5dB

fixedRefPower 1 to 101 65 65 RNC Fixed 0.5dB

numHsScchCodes 1 to 4 1 3 Cell Fixed codes

flexibleSchedulerOn 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hsScchMaxCodePower -35 to 15 -20 -20 Cell Fixed 0.5dB

hsScchMinCodePower -35 to 15 -150 -150 Cell Fixed 0.5dB

qualityCheckPower -2to 6 0 0 Cell Fixed 0.5dB

hsPowerMargin 0 to 200 2 2 Cell Fixed 0.5dB

numHsPdschCodes 1 to 15 5 4 Cell Fixed codes

dynamicHsPdschCodeAdditionOn 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary maxNumHsPdschCodes 5 to 15 5 10 Cell Fixed codes

ulOuterLoopRegulator 0 or 1 1=JUMP 1=JUMP RNC Fixed Integer

ulSirStep 0 to 50 10 10 RNC Fixed 0.1dB

blerQualityTargetDl(1,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(2,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER)

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

blerQualityTargetDl(2,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(2,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(2,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(5,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(5,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(6,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(6,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(18,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(18,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(7,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(7,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(11,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(15,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(15,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(16,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(16,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(19,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER)

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

blerQualityTargetDl(19,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(19,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(19,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(1,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(5,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(5,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(6,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(6,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(18,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(18,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(7,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(7,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(11,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(12,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(12,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER)

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

blerQualityTargetUl(12,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(12,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(15,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(15,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(16,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(16,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER)

sirMax -82 to 173 100 120 RNC Fixed 0.1dB

sirMin -82 to 173 -82 -82 RNC Fixed 0.1dB

deltaAck1 0 to 8 4 5 Cell Fixed -

deltaAck2 0 to 8 8 7 Cell Fixed -

deltaNack1 0 to 8 4 5 Cell Fixed -

deltaNack2 0 to 8 8 7 Cell Fixed -

deltaCqi1 0 to 8 4 4 Cell Fixed -

deltaCqi2 0 to 8 8 6 Cell Fixed -

initialCqiRepetitionFactor 1 to 4 1 1 Cell Fixed - initialAcknackRepetitionFactor 1 to 4 1 1 Cell Fixed - hsMeasurementPowerOffset -30 to 160 80 80 Cell Fixed 0.1dB codeThresholdPdu656 0 to 15 6 6 Cell Fixed codes

cqiFeedbackCycle 0 to 160 8 8 Cell Fixed ms

cqiErrors 0 to 100 10 10 Cell Fixed -

cqiErrorsAbsent 0 to 100 10 10 Cell Fixed -

cqiAdjustmentOn 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary

Parameter Range Ericsson Default AT&T Recommended Level Class Unit

maxEagchPowerDl -35 to 15 3 3 RNC Fixed dB

transmissionTargetError 1 to 50 3 3 RNC Fixed % ulInitSirTargetEdch -82 to 173 3 3 RNC Fixed 0.1dB