The following tables provide parameter ranges and default values involved in getting the UE into Idle Mode, Establishing a Call and Maintaining Mobility and Connectivity. They are listed in the same order they were presented. The Level column indicates the network element that owns the parameter. The class column indicates if the parameter is set based on Policy (must be set this way), Rule (must be set this way with exceptions), Fixed (recommended to be set this way) and Variable (set at your discretion).
Table 20: Configurable Parameter Lookup Table
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
Basic Design Requirements
uarfcnDl See section 4.1.2 N/A N/A Cell Variable Integer uarfcnUl See section 4.1.2 N/A N/A Cell Variable Integer
supportOf16qam 0=FALSE, 1=TRUE 0=FALSE 1=TRUE Cell Fixed Integer primaryScramblingCode 0 to 511 N/A 0 to 511 Cell Variable Integer
primaryCpichPower -100 to +500 300 300 Cell Fixed 0.1dBm Idle Mode
primarySchPower -350 to +150 -18 -18 Cell Fixed 0.1dB secondarySchPower -350 to +150 -35 -35 Cell Fixed 0.1dB bchPower -350 to +150 -31 -31 Cell Fixed 0.1dB
noOfMibValueTagRetrans 0 to 10 0 0 RNC Fixed Retransmissions sib1PLMNScopeValueTag 0 to 31 N/A 0 to 31 Cell Variable Integer
mcc 0 to 999 1 310 RNC Fixed Integer
mnc 0 to 999 N/A 410 RNC Fixed Integer
sib1StartPos 0 to 4094 4 4 RNC Fixed Frames
sib1RepPeriod 4, 8, 16 to 4096 32 32 RNC Fixed Frames
sib3StartPos 0 to 4094 2 2 RNC Fixed Frames
sib3RepPeriod 4, 8, 16 to 4096 16 16 RNC Fixed Frames
sib5StartPos 0 to 4094 6 6 RNC Fixed Frames
sib5RepPeriod 4, 8, 16 to 4096 32 32 RNC Fixed Frames
sib7StartPos 0 to 4094 2 2 RNC Fixed Frames
sib7RepPeriod 4, 8, 16 to 4096 16 16 RNC Fixed Frames sib7expirationTimeFactor 1, 2, 4, 8 to 256 1 1 RNC Fixed Factor sib11StartPos 0 to 4094 20 20 RNC Fixed Frames sib11RepPeriod 4, 8, 16 to 4096 128 128 RNC Fixed Frames
Parameter Range Ericsson Default AT&T Recommended Level Class Unit sib12StartPos 0 to 4094 14 14 RNC Fixed Frames sib12RepPeriod 4, 8, 16 to 4096 32 32 RNC Fixed Frames
nmo Mode 1 or 2 2 2 RA Fixed Integer
cellReserved RESERVED or NOT_RESERVED NOT_RESERVED NOT_RESERVED Cell Variable String accessClassNbarred 0 to 65535 0 0 Cell Fixed Integer
qRxLevMin -115 to -25 -115 -115 Cell Fixed dBm
maxTxPowerUl -50 to +33 24 24 Cell Fixed dBm
qQualMin -24 to 0 -18 -19 Cell Fixed dB
att 0=FALSE, 1=TRUE 1=TRUE 1=TRUE LA Fixed Integer
aichPower -22 to +5 -6 -6 Cell Fixed dB
ConstantValueCprach -35 to -10 -27 -27 Cell Fixed dB
powerOffsetP0 1 to 8 3 2 Cell Fixed dB
preambleRetransMax 1 to 64 8 15 Cell Fixed Preambles maxPreambleCycle 1 to 32 4 3 Cell Fixed Cycles
powerOffsetPpm -5 to +10 -4 0 Cell Fixed dB
dlInitSirTarget -82 to 173 41 41 RNC Fixed 0.1dB
cBackOff -60 to +60 0 0 RNC Fixed 0.25dB
ecNoPcpichDefault -20 to -10 -16 -16 RNC Fixed dB
pO2 0 to 24 12 12 RNC Fixed 0.25dB
pcpichPowerDefault 0 to 50 33 33 RNC Fixed dBm ulInitSirTargetSrb -82 to 173 57 57 RNC Fixed 0.1dB ulInitSirTargetLow -82 to 173 49 49 RNC Fixed 0.1dB ulInitSirTargetHigh -82 to 173 82 82 RNC Fixed 0.1dB ulInitSirTargetExtraHigh -82 to 173 92 92 RNC Fixed 0.1dB
cPO -30 to 30 0 0 RNC Fixed 0.1dB
lAC 1 to 65533, 65535 N/A N/A LA Variable Integer
rAC 0 to 255 N/A N/A RNC Variable Integer
t3212 0 to 255 10 10 LA Fixed 6minutes
multiRabSp0Available 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary multiRabUdi8Available 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary psStreaming128 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary allow384HsRab 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
pchPower -350 to 150 -4 -4 RNC Fixed 0.1dB
cnDrxCycleLengthCs 6 to 9 6=640 7=1280 RNC Fixed coeff cnDrxCycleLengthPs 6 to 9 7=1280 7=1280 RNC Fixed coeff utranDrxCycleLength 3 to 9 5=320 5=320 RNC Fixed coeff noOfPagingRecordTransm 1 to 5 2 2 RNC Fixed Integer noOfMaxDrxCycles 1 to 10 1 1 RNC Fixed DRX cycles
Admission Control
hsdpaUsersAdm 0 to 1000 10 10 Cell Var. Users maxNumHsdpaUsers 1 to 32 16 16 Cell Var. Users compModeAdm 0 to 128 15 15 Cell Var. Radio Links eulServingCellUsersAdm 0 to 100 32 4 Cell Fixed E-DCH users eulNonServingCellUsersAdm 0 to 100 100 10 Cell Fixed E-DCH users
dlCodeAdm 0 to 100 80 70 Cell Var. %
beMarginDlCode 0 to 20 1 1 Cell Var. 5%
sf8Adm 0 to 8 8 8 Cell Fixed Radio Links
sf16Adm 0 to 16 16 16 Cell Var. Radio Links
sf32Adm 0 to 32 32 32 Cell Var. Radio Links
sf16gAdm 0 to 16 16 16 Cell Var. Radio Links
sf16AdmUl 0 to 50 16 50 Cell Var. Radio Links
sf8AdmUl 0 to 50 8 8 Cell Var. Radio Links
sf4AdmUl 0 to 1000 0 6 Cell Var. Radio Links
pwrAdm 0 to 100 75 75 Cell Var. %
maximumTransmissionPower 0 to 500 400 400 Cell Var. 0.1dBm
beMarginDlPwr 0 to 100 10 10 Cell Var. %
pwrAdmOffset 0 to 100 10 10 Cell Var. %
aseUlAdm 0 to 500 160 500 Cell Var. ASE
beMarginAseUl 0 to 500 20 0 Cell Var. ASE
aseUlAdmOffset 0 to 500 40 40 Cell Var. ASE
aseDlAdm 0 to 500 240 500 Cell Var. ASE
beMarginAseDl 0 to 500 100 0 Cell Var. ASE
ulHwAdm 0 to 100 100 80 Site Var. %
beMarginUlHw 0 to 100 0 0 Site Var. %
dlHwAdm 0 to 100 100 100 Site Var. %
beMarginDlHw 0 to 100 0 0 Site Var. %
Parameter Range Ericsson Default AT&T Recommended Level Class Unit Call Establishment Related
emergencyCallRedirect 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary ulPathlossCheckEnabled TRUE or FALSE FALSE FALSE Cell Var. String
sf4UlPathlossThreshold 15 to 170 170 170 Cell Var. dB
loadSharingDirRetryEnabled 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary loadSharingGsmThreshold 0 to 100 75 100 Cell Fixed %
loadSharingGsmFraction 0 to 100 100 100 Cell Fixed %
directedRetryTarget 2G Neighbor N/A N/A Cell Var. N/A
loadSharingRrcEnabled 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary
loadSharingMargin 0 to 100 0 0 Cell Fixed %
loadSharingCandidate 3G Neighbor N/A N/A Nabr Var. N/A hsOnlyBestCell 0=FALSE, 1=TRUE 1=TRUE 1=TRUE RNC Fixed Binary
packetEstMode 0, 1 or 2 1 1 RNC Fixed Integer
activeQueueMgmt 0=OFF, 1=ON 0=OFF 0=OFF RNC Fixed Binary Cell Reselection
sIntraSearch 0=Continually, 1 to 27 0 22=10 Cell Fixed dB sInterSearch 0=Continually, 1 to 27 0 0 Cell Fixed dB
sRatSearch -32 to 20 4 4 Cell Fixed dB
sHcsRat -105 to 91 -105 -105 Cell Fixed dB
interFreqFddMeasIndicator 0=FALSE, 1=TRUE 0=FALSE 0=FALSE Cell Fixed Binary fachMeasOccaCycLenCoeff 0 to 12 0 4 Cell Fixed Integer
qualMeasQuantity 1=CPICH_RSCP or 2=CPICH_EC_NO 2=CPICH_EC_NO 2=CPICH_EC_NO Cell Fixed String
qHyst1 0 to 40 4 2 Cell Fixed dB
qHyst2 0 to 40 4 2 Cell Fixed dB
qOffset1sn(UtranRelation) -50 to 50 0 0 Nabr Fixed dB qOffset1sn(GsmRelation) -50 to 50 7 7 Nabr Fixed dB
qOffset2sn -50 to 50 0 0 Nabr Fixed dB
treSelection 0 to 31 2 1 Cell Fixed seconds
Intra-Frequency Handover
reportingRange1a 0 to 29 6 6 RNC Fixed 0.5dB
hysteresis1a 0 to 15 0 0 RNC Fixed 0.5dB
timeToTrigger1a 0 to 15 11=320 11=320 RNC Fixed ms
Parameter Range Ericsson Default AT&T Recommended Level Class Unit reportingInterval1a 0 to 16 3=1 3=1 RNC Fixed seconds measQuantity1 1=CPICH_RSCP or 2=CPICH_EC_NO 2=CPICH_EC_NO 2=CPICH_EC_NO Cell Fixed String reportingRange1b 0 to 29 10 10 RNC Fixed 0.5dB
hysteresis1b 0 to 15 0 0 RNC Fixed 0.5dB
timeToTrigger1b 0 to 15 12=640 12=640 RNC Fixed ms
hysteresis1c 0 to 15 2 2 RNC Fixed 0.5dB
timeToTrigger1c 0 to 15 11=320 11=320 RNC Fixed ms reportingInterval1c 0 to 16 3=1 3=1 RNC Fixed seconds
hysteresis1d 0 to 15 15 15 RNC Fixed 0.5dB
timeToTrigger1d 0 to 15 14=2560 14=2560 RNC Fixed ms filterCoefficient1 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff individualOffset(UtranCell) -10 to 10 0 0 Cell Fixed 0.5dB
w1a 0 to 20 0 0 RNC Fixed 0.1unit
w1b 0 to 20 0 0 RNC Fixed 0.1unit
Inter-Frequency and Inter-RAT Handover
usedFreqThresh2dEcno(hho) -24 to 0 -12 -12 Cell Fixed dB
hysteresis2d 0 to 29 0 4 RNC Fixed 0.5 dB
timeToTrigger2dEcno Various 320 320 RNC Fixed ms
usedFreqThresh2dRscp(hho) -115 to -25 -97 -106 ±4 Cell Fixed dBm
timeToTrigger2dRscp Various 320 320 RNC Fixed ms
usedFreqThresh2dEcno(sho) -24 to 0 -12 -15 Cell Fixed dB usedFreqThresh2dRscp(sho) -115 to -25 -97 -112 Cell Fixed dBm usedFreqThresh2dEcnoDrnc -24 to 0 -12 -12 RNC Fixed dB usedFreqThresh2dRscpDrnc -115 to -25 -97 -106 RNC Fixed dBm usedFreqRelThresh2fEcno 0 to 20 1 2 RNC Fixed dB
hysteresis2f 0 to 29 0 2 RNC Fixed 0.5dB
timeToTrigger2fEcno Various 1280 640 RNC Fixed ms
usedFreqRelThresh2fRscp 0 to 20 3 6 RNC Fixed dB
txPowerConnQualMonEnabled 0=FALSE, 1=TRUE 1=TRUE 0=FALSE RNC Fixed Binary
timeToTrigger6d Various 320 320 RNC Fixed ms
ueTxPowerThresh6b -50 to 33 18 21 RNC Fixed dB
timeTrigg6b Various 1280 1280 RNC Fixed ms
filterCoefficient2 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff filterCoeff6 0. to 9, 11, 13, 15, 17, 19 19 3 RNC Fixed coeff
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
usedFreqW2d 0 to 20 0 10 RNC Fixed 0.1unit
usedFreqW2f 0 to 20 0 10 RNC Fixed 0.1unit
FddIfHoSupp 0=FALSE, 1=TRUE 0=FALSE 0=FALSE RNC Fixed Binary FddGsmHoSupp 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hoType 0=IFHO, 1=GSM, 2=NONE 1 1=GSM_PREFERRED Cell Fixed String
defaultHoType 0=IFHO, 1=GSM, 2=NONE 1 1=GSM_PREFERRED Cell Fixed String utranRelThresh3aEcno -10 to 10 -1 2 RNC Fixed dB
hysteresis3a 0 to 15 0 4 RNC Fixed 0.5dB
gsmThresh3a -115 to 0 -102 -98 RNC Fixed dBm
timeToTrigger3a 0 to 15 6=100 6=100 RNC Fixed ms utranRelThresh3aRscp -20 to 20 -3 7 RNC Fixed dB gsmFilterCoefficient3 0. to 9, 11, 13, 15, 17, 19 1 1 RNC Fixed coeff utranFilterCoefficient3 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff
utranW3a 0 to 20 0 10 RNC Fixed 0.1unit
utranRelThreshRscp 0 to 40 5 5 RNC Fixed dB
usedFreqRelThresh4_2bEcno -10 to 10 -1 -1 RNC Fixed dB
hyst4_2b 0 to 75 10 10 RNC Fixed 0.1dB
nonUsedFreqThresh4_2bEcno -24 to 0 -11 -13 RNC Fixed dB nonUsedFreqThresh4_2bRscp -115 to 25 -94 -105 RNC Fixed dBm timeTrigg4_2b 0, 10, 20,40, 60, 80, 100, 120, 160, 200,
240, 320, 640, 1280, 2560, 5000 100 100 RNC Fixed ms UsedFreqRelThresh4_2bRscp -20 to 20 -3 -3 RNC Fixed dB
timeToTrigger2fRscp Various 1280 640 RNC Fixed ms
filterCoeff4_2b 0. to 9, 11, 13, 15, 17, 19 2 2 RNC Fixed coeff usedFreqW4_2b 0. to 9, 11, 13, 15, 17, 19 0 0 RNC Fixed coeff nonUsedFreqW4_2b 0. to 9, 11, 13, 15, 17, 19 0 0 RNC Fixed coeff
HS Cell Change
hsQualityEstimate 0=CPICH_EC_NO, 1=CPICH_RSCP 1=RSCP 1=RSCP RNC Fixed Binary
hsHysteresis1d 0 to 75 10 10 RNC Fixed 0.1dB
hsTimeToTrigger1d Various 640 640 RNC Fixed ms
hsCellChangeAllowed 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hsToDchTrigger(changeOfBestCellIntraRnc) 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hsToDchTrigger(servHsChangeIntraRnc) 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary
Parameter Range Ericsson Default AT&T Recommended Level Class Unit hsToDchTrigger(poorQualityDetected) 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary Channel Switching
downswitchThreshold 0 to 32 0 0 RNC Fixed 1kbit/s downswitchTimer 0 to 1000 10 100 RNC Fixed 100ms downswitchTimerThreshold 0 to 64 0 0 RNC Fixed 1kbit/s hsdschInactivityTimer 1 to 255 2 10 RNC Fixed seconds
ulRlcBufUpswitch Various 256 256 RNC Fixed bytes
dlRlcBufUpswitch 0 to 2000 500 500 RNC Fixed bytes
inactivityTimer 1 to 1440 120 10 RNC Fixed seconds
inactivityTimerPch 1 to 240 30 30 RNC Fixed minutes dlDownswitchBandwidthMargin 0 to 100 0 80 RNC Fixed % dlThroughputDownswitchTimer 0 to 2000 20 20 RNC Fixed 100ms ulDownswitchBandwidthMargin 0 to 100 0 80 RNC Fixed % ulThroughputDownswitchTimer 0 to 2000 20 20 RNC Fixed 100ms
bandwidthMargin 0 to 100 90 90 RNC Fixed %
upswitchTimer 0 to 100 5 5 RNC Fixed 100ms
dlThroughputAllowUpswitchThreshold 0 to 100 0 0 RNC Fixed % downswitchPwrMargin 0 to 20 2 2 RNC Fixed 0.5dB
coverageTimer 0 to 100 10 10 RNC Fixed 100ms
upswitchPwrMargin 0 to 20 6 6 RNC Fixed 0.5dB
bandwidthMarginUl 0 to 100 0 90 RNC Fixed %
upswitchTimerUl 0 to 100 5 1 RNC Fixed 100ms
ulThroughputAllowUpswitchThreshold 0 to 100 0 90 RNC Fixed %
reportHysteresis 0 to 20 6 6 RNC Fixed 0.5dB
downswitchTimerSp 0 to 180 2 2 RNC Fixed 0.5seconds
ulRlcBufUpswitchMrab Various 8 8 RNC Fixed bytes
dlRlcBufUpswitchMrab 0 to 20 0 8 RNC Fixed 100bytes inactivityTimeMultiPsInteractive 0 to 10000 50 50 RNC Fixed 100ms queueSelectAlgorithm 1 to 6 1 3 Cell Fixed Integer airRateTypeSelector 0=ACKNOLEDGED or
1=TRANSMITTED 1=TRANSMITTED 1=TRANSMITTED Cell Fixed Integer HSDPA Scheduling
eulTargetRate 0 to 6016 128 128 Cell Fixed 1kbit/s eulNoReschUsers 0 to 32 5 5 Cell Fixed E-DCH users eulMaxNoSchEdch 0 to 100 100 16 Cell Fixed E-DCH users
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
eulNoErgchGroups 1. to 4 4 4 Cell Fixed E-RGCH groups eulMaxShoRate 0 to 1472 128 1472 Cell Fixed 1kbit/s
eulReservedHwBandwidthSchedDataNonServCell 1 to 1472 128 128 Cell Fixed 1kbit/s
eulThermalLevelPrior -1150 to -600 -1040 -1040 Cell Fixed 0.1dBm eulSlidingWindowTime 10 to 864000 1800 1800 Cell Fixed seconds eulMinMarginCoverage 0 to 1.0 10 10 Cell Fixed -
eulNoiseFloorLock 0=FALSE, 1=TRUE 0=FALSE 0=FALSE Cell Fixed - eulOptimalNoisefloorEstimate -1150 to -600 or -1 -1040 -1040 Cell Fixed 0.1dBm
eulMaxRotCoverage 0 to 550 100 100 Cell Fixed 0.1dB eulMaxOwnUuLoad 0 to 550 30 80 Cell Fixed 0.1dB harqTransmUlTti10Max 1 to 8 4 4 Cell Fixed attempts Congestion Detection and Resolution
pwrOffset 0 to 100 5 5 Cell Fixed %
pwrHyst 0 to 60000 300 300 Cell Fixed ms
iFCong 0 to 621 621 621 Cell Fixed 0.1dBm
iFOffset 0 to 621 0 0 Cell Fixed 0.1dB
iFHyst 0 to 6000 6000 6000 Cell Fixed 10ms
releaseAseDlNg 0 to 500 3 3 Cell Fixed ASE
tmInitialGhs 10 to 100000 500 500 Cell Fixed ms tmInitialG 10 to 100000 3000 3000 Cell Fixed ms tmCongActionNg 500 to 100000 800 800 Cell Fixed ms releaseAseDlGhs 0 to 5000 0 0 Cell Fixed 0.ASE tmCongActionGhs 10 to 100000 300 300 Cell Fixed ms
releaseAseDl 0 to 500 1 1 Cell Fixed ASE
tmCongAction 300 to 100000 2000 2000 Cell Fixed ms Radio Connection Supervision
cchWaitCuT 0 to 200 9 9 RNC Fixed 5minutes
t305 0 to 7 3=30 3=30 RNC Fixed minutes
nOutSyncInd 1 to 256 10 10 Cell Fixed frames
rlFailureT 0 to 255 10 10 Cell Fixed 0.1seconds
nInSyncInd 1 to 256 3 3 Cell Fixed frames
dchRcLostT 0 to 100 50 50 RNC Fixed 0.1seconds
Parameter Range Ericsson Default AT&T Recommended Level Class Unit Power and Code Control
maxFach1Power -350 to 150 18 18 Cell Fixed 0.1dB maxFach2Power -350 to 150 15 15 Cell Fixed 0.1dB
pOffset1Fach 0 to 24 0 0 Cell Fixed 0.1dB
pOffset3Fach 0 to 24 0 0 Cell Fixed 0.1dB
pO1 0 to 24 0 0 RNC Fixed 0.25dB
pO3 0 to 24 12 12 RNC Fixed 0.25dB
minPwrRl -350 to 150 -150 -150 Cell Fixed 0.1dB minimumRate 0 to 1600000 1590 1590 Cell Fixed 10bps
minPwrMax -350 to 150 0 0 Cell Fixed 0.1dB
interRate 0 to 1600000 7760 7760 Cell Fixed 10bps interPwrMax -350 to 150 38 38 Cell Fixed 0.1dB maxRate 0 to 1600000 40690 40690 Cell Fixed 10bps
maxPwrMax -350 to 150 48 48 Cell Fixed 0.1dB
initShoPowerParam -20 to 20 -2 -2 RNC Fixed 1dB
cNbifho -50 to 150 10 10 RNC Fixed 0.1dB
dlPcMethod 1 to 4 3=BALANCING 3=BALANCING RNC Fixed Integer
fixedPowerDl 1 to 101 65 65 RNC Fixed 0.5dB
fixedRefPower 1 to 101 65 65 RNC Fixed 0.5dB
numHsScchCodes 1 to 4 1 3 Cell Fixed codes
flexibleSchedulerOn 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary hsScchMaxCodePower -35 to 15 -20 -20 Cell Fixed 0.5dB
hsScchMinCodePower -35 to 15 -150 -150 Cell Fixed 0.5dB
qualityCheckPower -2to 6 0 0 Cell Fixed 0.5dB
hsPowerMargin 0 to 200 2 2 Cell Fixed 0.5dB
numHsPdschCodes 1 to 15 5 4 Cell Fixed codes
dynamicHsPdschCodeAdditionOn 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary maxNumHsPdschCodes 5 to 15 5 10 Cell Fixed codes
ulOuterLoopRegulator 0 or 1 1=JUMP 1=JUMP RNC Fixed Integer
ulSirStep 0 to 50 10 10 RNC Fixed 0.1dB
blerQualityTargetDl(1,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(2,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER)
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
blerQualityTargetDl(2,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(2,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(2,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(5,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(5,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(6,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(6,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(18,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(18,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(7,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(7,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(9,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(10,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(11,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(12,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(15,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(15,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(16,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(16,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(19,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER)
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
blerQualityTargetDl(19,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(19,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(19,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,1) -63 to 0 -30 -30 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetDl(20,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(1,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(2,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(5,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(5,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(6,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(6,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(18,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(18,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(7,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(7,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(9,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(10,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(11,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(12,1) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(12,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER)
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
blerQualityTargetUl(12,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(12,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(15,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(15,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(16,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(16,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(19,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,1) -63 to 0 -30 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,2) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,3) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,4) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER) blerQualityTargetUl(20,5) -63 to 0 -20 -20 RNC Fixed 10 Log10(BLER)
sirMax -82 to 173 100 120 RNC Fixed 0.1dB
sirMin -82 to 173 -82 -82 RNC Fixed 0.1dB
deltaAck1 0 to 8 4 5 Cell Fixed -
deltaAck2 0 to 8 8 7 Cell Fixed -
deltaNack1 0 to 8 4 5 Cell Fixed -
deltaNack2 0 to 8 8 7 Cell Fixed -
deltaCqi1 0 to 8 4 4 Cell Fixed -
deltaCqi2 0 to 8 8 6 Cell Fixed -
initialCqiRepetitionFactor 1 to 4 1 1 Cell Fixed - initialAcknackRepetitionFactor 1 to 4 1 1 Cell Fixed - hsMeasurementPowerOffset -30 to 160 80 80 Cell Fixed 0.1dB codeThresholdPdu656 0 to 15 6 6 Cell Fixed codes
cqiFeedbackCycle 0 to 160 8 8 Cell Fixed ms
cqiErrors 0 to 100 10 10 Cell Fixed -
cqiErrorsAbsent 0 to 100 10 10 Cell Fixed -
cqiAdjustmentOn 0=FALSE, 1=TRUE 0=FALSE 1=TRUE RNC Fixed Binary
Parameter Range Ericsson Default AT&T Recommended Level Class Unit
maxEagchPowerDl -35 to 15 3 3 RNC Fixed dB
transmissionTargetError 1 to 50 3 3 RNC Fixed % ulInitSirTargetEdch -82 to 173 3 3 RNC Fixed 0.1dB