Programming SE5000 Series tachographs

5. PROGRAMMING A TACHOGRAPH

5.6 Programming SE5000 Series tachographs

• K-Factor

• Odometer

• Current time

• Current date

• Time Offset

• Output Shaft Factor

• CANBus enabled

• Speedo O/P Factor

• D6 pin function • VIN • Service delay • Install Date • Reset Heartbeat • D4 pin function

• Low Speed Limit

• L-Factor

• Tyre Size

• Next Calib. Date

• Veh. Reg. Nation

• VRN

• Speed Authorised

• Illum. Input

• Revs Inp. C3/CAN

• Pref. Language

• CANBus type

• D7 pin function

• Serial Data Out

• Backlight Select

• Illumination Lvl

• Illumination Off

• RPM Factor

• CAN Termination

• Add. Event Rec.

• Eng. Speed Rec.

• VRESD

• Veh. Speed Rec.

• VRVSD

• D5 pin function

• CAN trip reset

• Pre-Overspeed • Pre-NextCalib • Display Function • Max.Warranty • War.Valid Time • Warranty Time • No. writes WT • Activation Time • W-factor

Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 52

Connections

Table 13: Stoneridge SE5000 Programming connections Tachograph Harness Connection

SE5000 Series Z DIN plug to socket C on Programmer and D-shaped connector to socket on front of tachograph.

Procedure

Select READ ALL DATA from the main menu

and press ENTER. SE5000 MAIN MENU :READ ALL DATA

Select MODIFY DATA from the main menu and press ENTER.

Use the ← and → to select the parameter you wish to alter.

SE5000 MAIN MENU :MODIFY DATA

K-factor - Press ENTER and type in the new

value. Press enter again to confirm the value. K-factor :8000 Odometer reading - Press ENTER and key in

the required new odometer reading. Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000.

Odometer : 21 055 406.0

Current time - Press ENTER and a cursor will flash. Key in the current time and press ENTER.

Note the time should be set to UTC time.

Current time :10:35

Current date - Press ENTER and a cursor will flash. Key in the current date and press ENTER.

Note the time should be set to UTC time.

Current date :19/10/2003

Time offset - Press ENTER and use the up/down arrow keys to choose a time offset between +23:00 and –23:00 hours and +59 and –59 minutes.

Time offset :+1: +00

O/P shaft factor – Press ENTER and a cursor will flash. Key in the required value and press ENTER.

Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 53

CANBus enabled - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection.

CANBus enabled :On

Speedo OP factor - Press ENTER and a cursor will flash.

Key in the required value and press ENTER.

Speedo OP factor :4971

D6 pin function - Press ENTER and use the

← and → keys to select OFF, Revs warning or Speedometer.

D6 pin function :OFF

VIN - Press ENTER and type the Vehicle Identification Number.

This can be up to 17 characters long. Press ENTER to confirm the selection.

VIN

:1234567890ABCDEFG

Service delay – Read Only. Service delay :104 weeks Install date - Press ENTER and a cursor will

flash. Key in the date of installation of the tachograph and press ENTER.

Install date :19/09/2001

Reset Heartbeat - Press ENTER and use the

← and → keys to select ON or OFF. Press ENTER to confirm the selection.

Note: when set to ON the vehicle cluster presence is confirmed by the tachograph.

Reset Heartbeat :Off ← →

D4 pin function - Press ENTER and use the

← and → keys to select DTC Warning, Chart Change, Dynafleet, Low speed, Functions or Off.

D4 pin function :Off

← →

Low Speed Limit - Press ENTER and a cursor will flash. Key in the Low Speed Limit value.

Low Speed Limit :5 km/h

L-Factor – Press ENTER and a cursor will

flash. Key in the L-Factor value. L-Factor :1234 mm Tyre Size - Press ENTER and type the Tyre

Size. This can be up to 15 characters long. Press ENTER to confirm the selection.

Tyre Size

:1234567890ABCDE Next Calib Date - Press ENTER and a cursor

will flash.

Key in the next calibration date and press ENTER.

Next Calib Date :19/10/2005

Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 54

Vehicle Registration Nation - Press ENTER and type the Vehicle Registration Nation. This can be up to 3 characters long. Press ENTER

to confirm the selection.

The Vehicle Registration Nation can also be referred to as Registering Member State.

Veh. Reg. Nation :123

VRN - Press ENTER and type the VRN. This can be up to 13 characters long. Press ENTER to confirm the selection.

VRN

:1234567890ABC Speed Authorised - Press ENTER and a

cursor will flash.

Key in the Speed authorised value.

Speed Authorised :125 km/h

Illumination Input - Press ENTER and use the ← and → keys to select one of the following options. OFF, CAN ONLY, A2 ONLY.

Illum. Input :OFF Revs Input C3/CAN - Press ENTER and use

the ← and → keys to choose between the following options. CAN ENABLED, C3 ENABLED.

Revs Inp. C3/CAN :CAN ENABLED

Preferred Language - Press ENTER and the cursor will flash. Enter the correct code for the required language and press ENTER to accept it.

Pref. Language :en

CANBus type - Press ENTER and type the CANbus type. This can be up to 2 digits long. Press ENTER to confirm the selection.

CANBus type :24

D7 pin function - Press ENTER and use the

← and → keys to select DISABLE or ENABLE. D7 pin function :DISABLE Serial Data Out - Press ENTER and use the

← and → keys to select one of the following options. DISABLE, ENABLE SRE, ENABLE 2400.

Serial Data Out :ENABLE SRE

Backlight Select - Press ENTER and use the

← and → keys to select one of the following options. Colour 1, Colour 2, No Colour.

Backlight Select :Colour 1

Illumination Lvl - Press ENTER and type the Illumination Lvl. This can be up to 3 digits long. Press ENTER to confirm the selection.

Illumination Lvl :0

Illumination Off - Press ENTER and type the

Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 55

long. Press ENTER to confirm the selection.

RPM Factor - Press ENTER and type the RPM Factor. This can be up to 5 digits long. Press ENTER to confirm the selection.

RPM Factor :12

CAN Termination - Press ENTER and use the ← and → keys to select DISABLE or ENABLE.

CAN Termination :ENABLE

Add. Event Rec. - Press ENTER and use the

← and → keys to select DISABLE or ENABLE. Add. Event Rec. :ENABLE Eng. Speed Rec. - Press ENTER and use the

← and → keys to select DISABLE or ENABLE. Eng. Speed Rec. :ENABLE

VRESD (Vu Ranges Engine Speed Data) - Press ENTER and type the VRESD. This can be up to 7 digits long. Press ENTER to confirm the selection.

VRESD :Rng1= 7999.875

Veh. Speed Rec. - Press ENTER and use the

← and → keys to select DISABLE or ENABLE. Veh. Speed Rec. :ENABLE

VRVSD (Vu Ranges Vehicle Speed Data) - Press ENTER and type the VRVSD. This can be up to 3 digits long. Press ENTER to confirm the selection.

VRVSD :Rng1= 111

D5 pin function - Press ENTER and use the

← and → keys to select DISABLE or ENABLE. D5 pin function :DISABLE

CAN trip reset - Press ENTER and use the ←

and → keys to select ISO or MAN. CAN trip reset :MAN Pre-Overspeed - Press ENTER and type the

Pre-Overspeed. This can be up to 2 digits long. Press ENTER to confirm the selection. Once done a new screen will appear

requesting the input for TCO1 WARNING?, use the ← and → keys to select DISABLE or ENABLE.

Pre-Overspeed :6

TCO1 WARNING? :ENABLE

Pre-NextCalib - Press ENTER and type the Pre-NextCalib. This can be up to 3 digits long. Press ENTER to confirm the selection.

Pre-NextCalib :111

Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 56

Display Function - Press ENTER and use the ← and → keys to select DISABLE or ENABLE.

Display Function :ENABLE

Max.Warranty – This parameter is READ

ONLY. Max. Warranty :36 MONTHS

War.Valid Time - This parameter is READ

ONLY. War.Valid Time :00/00/0000

Warranty Time - Press ENTER and type the Warranty Time. This can be up to 2 digits long. Press ENTER to confirm the selection.

Warranty Time :30 MONTHS

No. writes WT - This parameter is READ

ONLY. No. writes WT :0

Activation Time - This parameter is READ

ONLY. Activation Time :UNACTIVATED

W-Factor - Press ENTER and a cursor will

flash. Key in the W-Factor value. W-Factor :8000

Having entered the values to be programmed into the tachograph, return to the MAIN MENU by pressing Menu button and now select SEND ALL DATA (shortcut key 9) by pressing the arrow keys.

SE5000 MAIN MENU :SEND ALL DATA

As instructed on the display, press ENTER to send the data. On completion of the data transfer the Programmer will indicate Data Transfer OK.

Sending Data Data Transfer OK

In the event of a problem, the message Transfer FAILURE will be displayed. In that event check the harness connection.

Transfer FAILURE

Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 57