Programming the Codeplug Data into an IntelliRepeater

4. Click Continue. On reset the following window is opened.

5. Click Continue. The main RSS window appears.

Programming the Codeplug Data into an IntelliRepeater . . . .

Station Installed in a SmartZone 2.0.3 or 2.7E System

After saving the codeplug data to an archive file on the PC hard disk, you must program the codeplug data into a conventional or 6809 station’s codeplug.

N

OTE

When programming the codeplug, you may be asked whether you want to condition the codeplug. Follow the instructions in the message window to perform this task.

Conditioning is required only once.

With the PC connected and the RSS program running, perform the following to program data into the station codeplug:

1. From the File menu, select Write to Device, or click Write to Device icon on the toolbar.

RADIO SERVICE SOFTWARE INSTRUCTION MANUAL PROGRAMMINGTHE CODEPLUG DATAINTOAN INTELLIREPEATER STATION INSTALLEDINA SMARTZONE 2.0.3 OR 2.7E SYSTEM

A confirmation window appears.

2. Click Yes. After a few seconds, the following Please Enter the Start Up Channel window appears.

3. Verify that the displayed channel is the start up channel. Change if required. Then click Next >>. A message window appears asking for verification of the Startup Channel and the serial number.

Save file icon File/Write to Device

Menu Item

PROGRAMMINGTHE CODEPLUG DATAINTOAN INTELLIREPEATER STATION INSTALLEDINA SMARTZONE 2.0.3 OR 2.7E SYSTEM CHAPTER 3: OPTIMIZATION

4. Click Yes to start the codeplug write operation. The progress of the write operation appears. When the operation is complete, an RSS message window asks whether you would like to reset the device.

5. Click Yes to reset all connected IntelliRepeaters to activate the codeplug. A message window appears stating that a reset is in progress.

RADIO SERVICE SOFTWARE INSTRUCTION MANUAL PROGRAMMINGTHE CODEPLUG DATAINTOAN INTELLIREPEATER STATION INSTALLEDINA SMARTZONE 3.0, 3.5, OR 4.1 SYSTEM

6. Click Continue. On reset, the following window appears.

7. Click Continue. The display returns to the main RSS window.

Programming the Codeplug Data into an IntelliRepeater . . . .

Station Installed in a SmartZone 3.0, 3.5, or 4.1 System

After saving the codeplug data to an archive file on the PC hard disk, you must program the codeplug data into a conventional or 6809 station’s codeplug.

N

OTE

When programming the codeplug, you may be asked whether you want to condition the codeplug. Follow the instructions in the message window to perform this task.

Conditioning is required only once.

With the PC connected and the RSS program running, perform the following to program data into the station codeplug:

1. From the File menu, select Write to Device, or click Write to Device icon on the toolbar.

PROGRAMMINGTHE CODEPLUG DATAINTOAN INTELLIREPEATER STATION INSTALLEDINA SMARTZONE 3.0, 3.5, OR 4.1 SYSTEM CHAPTER 3: OPTIMIZATION

A confirmation window appears.

2. Click Yes. After a few seconds the following crossload message window appears.

3. Click Yes to write the codeplug to the connected IntelliRepeater station and then have that station load on each IntelliRepeater connected to it with the codeplug. The following Please enter the desired time and date window appears.

Save file icon File/Write to Device

Menu Item

RADIO SERVICE SOFTWARE INSTRUCTION MANUAL PROGRAMMINGTHE CODEPLUG DATAINTOAN INTELLIREPEATER STATION INSTALLEDINA SMARTZONE 3.0, 3.5, OR 4.1 SYSTEM

4. Enter the current date and time.

5. When complete, click Next. The following Please Enter the Start Up Channel window appears.

6. Verify that the displayed channel is the start up channel. Change if required. Then click Next>>.

7. Click Yes to start the codeplug write operation. The progress of the write operation appears. When the operation is complete, an RSS message window asks whether you would like to reset the device.

8. Click Yes to reset all connected IntelliRepeaters to activate the codeplug. A message window is opened stating that a reset is in progress.

9. Click Continue. On reset, the following window is opened.

PERFORMING STATION ALIGNMENT CHAPTER 3: OPTIMIZATION

10. Click Continue. The display returns to the main RSS window.

. . . . Performing Station Alignment

Some of the station tuning, alignment, and adjustment tasks have been performed in the factory prior to shipment. These procedures do not need to be performed at the time of installation and are generally required only after maintenance of certain modules. These procedures are listed below with their location in this manual.

• “Aligning Power Output Procedure” on page 6-4

• “Aligning Power Output Procedure for a Quantro 350W VHF Station” on page 6-7

• “Aligning Tx Deviation Gain Adjust Procedure, 350W VHF Stations” on page 6-11

• “Aligning Reference Modulation Compensation Procedure” on page 6-14

Certain site-specific alignment tasks must be performed during optimization at the time they are installed and prior to being placed into service. The tasks required are shown below:

• “RX and TX Wireline Alignment” on page 3-55

• “Aligning Radio Signal Strength Indicator (RSSI)” on page 3-68

• “Aligning Squelch Adjust Procedure” on page 3-71

• “Equalizing Batteries” on page 3-73

• “Calibrating Reference Oscillator Procedure” on page 3-75

• “Setting ASTRO Tx Align and Test Procedure” on page 3-82

• “Generating ASTRO Test Patterns” on page 3-85

• “TDATA Calibration (6809 Trunking Station Only)” on page 3-88

• “ASTRO Bit Error Rate Reports” on page 3-90

I

MPORTANT

Before performing any of the station alignment procedures, you must dekey the station transmitter. In addition, when you enter the Alignment Screen, the following prompt is displayed, "The station is Automatically put into Access Disable mode. A station reset is required to return the station to Access Enable. Do you want to continue?" Click Yes to continue. When the alignment procedures are completed, deactivate Access Disable and restore the station to normal operation by performing a station reset.

RADIO SERVICE SOFTWARE INSTRUCTION MANUAL PERFORMING STATION ALIGNMENT

I

MPORTANT

When entering data in any of the alignment screen fields, you must click Save to save the value to the station. If you enter a parameter value and exit the alignment screen without saving the value, the station continues to operate using the previous value.

N

OTE

If you experiment with a parameter value without intending to permanently change the value stored in the station, do not click Save and reset the station to restore the original parameter value(s).