• Easy connection to the controller via integrated Ethernet
interface or a separate version with RS 485/422
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the respec-
tive standard products. SIPLUS extreme specific information
was added.
For technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme
■Technical specifications
Article number 6AG1647-0AH11-2AX0 6AG1647-0AA11-2AX0 6AG1647-0AD11-2AX0
Based on 6AV6647-0AH11-3AX0 6AV6647-0AA11-3AX0 6AV6647-0AD11-3AX0
SIPLUS HMI KP300 BASIC MONO PN 3,6"
SIPLUS KTP400 BASIC MONO PN 3,8" SIPLUS KTP600 BASIC COLOR PN
Ambient conditions
Ambient temperature in operation
• Operation (vertical installation)
- For vertical installation, min. -25 °C -10 °C -25 °C
- For vertical installation, max. 60 °C 50 °C 60 °C
Extended ambient conditions
• Relative to ambient temperature- atmospheric pressure-installation altitude Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) Relative humidity
- With condensation, tested in accordance with IEC 60068-2-38, max.
100 %; RH incl. condensation/frost (no commissioning under conden- sation conditions)
100 %; RH incl. condensation/frost (no commissioning under conden- sation conditions)
100 %; RH incl. condensation/frost (no commissioning under conden- sation conditions)
Resistance
- against biologically active substances / conformity with EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
- against chemically active substances / conformity with EN 60721-3-3
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! - against mechanically active
substances / conformity with EN 60721-3-3
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
3
■Technical specifications (continued)
SIMATIC S7-1200 basic controller
Operator control and monitoring
SIPLUS Basic Panels (1st Generation)
■Ordering data
Article No. Article No.Article number 6AG1647-0AE11-4AX0 6AG1647-0AF11-4AX0 6AG1647-0AG11-4AX0
Based on 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0 6AV6647-0AG11-3AX0
SIPLUS HMI KTP1000 BASIC COLOR DP 10,4"
SIPL6AV6647-0AF11-3AX0US KTP1000 BASIC COLOR DP 10,4"
SIPLUS HMI TP1500 BASIC COLOR PN 15"
Ambient conditions
Ambient temperature in operation
• Operation (vertical installation) 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C
- For vertical installation, min. 0 °C 0 °C 0 °C
- For vertical installation, max. 50 °C 50 °C 50 °C
Extended ambient conditions
• Relative to ambient temperature- atmospheric pressure-installation altitude Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) Relative humidity
- With condensation, tested in accordance with IEC 60068-2-38, max.
100 %; RH incl. condensation/frost (no commissioning under conden- sation conditions)
100 %; RH incl. condensation/frost (no commissioning under conden- sation conditions)
100 %; RH incl. condensation/frost (no commissioning under conden- sation conditions)
Resistance
- against biologically active substances / conformity with EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
- against chemically active substances / conformity with EN 60721-3-3
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
- against mechanically active substances / conformity with EN 60721-3-3
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
SIPLUS HMI KP300 Basic mono PN
6AG1647-0AH11-2AX0
For areas with extreme medial exposure (conformal coating); ambient temperature -25 ... +60 °C
SIPLUS HMI KTP400 Basic mono PN
6AG1647-0AA11-2AX0
For areas with extreme medial exposure (conformal coating); ambient temperature -10 ... +60 °C
SIPLUS HMI KTP600 Basic color PN
6AG1647-0AD11-2AX0
For areas with extreme medial exposure (conformal coating); ambient temperature -25 ... +60 °C
SIPLUS HMI KTP1000 Basic color DP
6AG1647-0AE11-4AX0
For areas with extreme medial exposure (conformal coating); ambient temperature 0 ... +50 °C
SIPLUS HMI KTP1000 Basic color PN
6AG1647-0AF11-4AX0
For areas with extreme medial exposure (conformal coating); ambient temperature 0 ... +50 °C
SIPLUS HMI TP1500 Basic color PN
6AG1647-0AG11-4AX0
For areas with extreme medial exposure (conformal coating); ambient temperature 0 ... +50 °C