• No results found

1.1.1.143 To Route Line L1002 from T-135 to E-107

In document 85182668 AutoPLANT 3D Training(1) (Page 134-146)

1. Type ISO1 and press Enter, then ZOOM Window around T-135 and E-107 as shown above.

2. Select L1002 from the LineNumber field of the Project Preferences control.

3. To connect a flange to the T-135 vessel’s N1 shell inlet nozzle, select Flanges>Weldneck from the Piping menu. Respond to the prompts as follows to place the flange.

Elevation/Insert/<Pick point>:

Pick vertical vessel shell inlet nozzle T-135-N1.

Relative/Elev/<Pick point or Return for fit-fit>:

Press Enter accept the insertion point and connect the flange to the nozzle face.

4. Select Bends and Returns > 90o LR Elbow from the Piping menu. Respond to the prompts as follows to connect elbow (1) to the flange using the fitting-to-fitting method.

Relative/Elev/<Pick point or Return for fit-fit>:

Press Enter to accept the default insertion point at the weld end of the flange.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type D and press Enter to specify the orientation in the negative/Z direction.

Up/Down/East/West/North/south/Align/Rotate/reseT/<enter orientation or press Return when done>

Press Enter again to accept this orientation and place the elbow.

5. Select Bends and Returns > 90o LR Elbow from the Piping menu. Respond to the prompts as follows to place elbow (2) Relative to elbow (1) at a bottom-of-pipe elevation of 115’

{14500mm}.

Relative/Elev/<Pick point or Return for fit-fit>:

Type R and press Enter to place the elbow at a relative distance from the first elbow placed.

Align/change Ref point/Elev/<Enter distance or Return for fit-fit>:

Type E and press Enter to display the Enter Elevation dialog as shown below.

Enable the Bottom of Pipe radio button and type 115’ {34500} in the Elevation field, then press OK.

Toggle insertion point/<Press enter to select>:

Press Enter to accept the default insertion point at the center of the elbow

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type W and press Enter to specify the orientation in the negative-X direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter again to accept this orientation and place the elbow.

6. Select Bends and Returns > 90o LR Elbow from the Piping menu. Respond to the prompts

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type T and press Enter to toggle the reference point to the horizontal elbow port.

Relative/Toggle/Elev.<Pick point or Return for fit-fit>:

Type R and press Enter to place the elbow at a relative distance from elbow (2).

Toggle/Align/change Ref point/Elev/<enter distance or Return for fit-fit>:

Type 12’-6” {3750} and press Enter to specify the relative distance.

Toggle insertion point/<Press enter to select>:

Press Enter to accept the default insertion point at the center of the elbow.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type D and press Enter to specify the orientation in the negative-Z direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter again to accept the orientation and place the elbow.

7. Select Bends and Returns < 90o LR Elbow from the Piping menu. Respond to the prompts as follows to place elbow (4) a relative vertical distance from center of elbow (3).

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type T and press Enter to toggle the reference point to the vertical port of the elbow.

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type R and press Enter to place the elbow at a relative distance from elbow (3).

Toggle/Align/change Ref point/Elev/<Enter Distance or Return for fit-fit>:

Type 2’-6” {750} and press Enter to specify the relative distance.

Toggle insertion point/<Return to select>:

Press Enter to accept the default insertion point at the center of the elbow.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type S and press Enter to specify the orientation in the negative-Y direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter again to accept the orientation and place the elbow.

8. Press Enter to re-execute the elbow placement command. Respond to the prompts as follows to place elbow (5) relative to elbow (4) and aligned with one of the bottom elbows in line L1001 as shown below.

Relative/Toggle/Elev/<Pick point or return for fit-fit>:

Type T and press Enter to toggle the reference point to the horizontal end of the elbow.

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type R and press Enter to place the elbow relative to elbow (4).

Toggle/Align/change Ref point/<Enter Distance or Return for fit-fit>:

Type A and press Enter to specify that you want to align this elbow with another component.

Pick component to align to:

Pick the lower elbow on line L1001.

Select port to align to:

Toggle/<Enter to select currently highlighted port>:

Press Enter to accept the highlighted elbow port.

Toggle insertion point/<Return to select>:

Press Enter to accept the default insertion point at the center of the elbow.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type D and press Enter to specify the orientation in the negative-Z direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter to accept the orientation and place the elbow.

9. Press Enter to re-execute the elbow placement command. Respond to the prompts as follows to place elbow (6) relative to elbow (5).

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type T and press Enter to toggle the reference point to the other end of elbow (5).

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type 2’-6” {750} and press Enter to specify the relative distance.

Toggle insertion point/<Return to select>:

Press Enter to accept the default insertion point in the center of the elbow.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type E and press Enter to specify the orientation in the position X direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter again to accept the orientation and place the elbow.

10 Press Enter to re-execute the elbow placement command. Respond to the prompts as follows to place elbow (7).

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type T and press Enter to toggle the reference point to the other end of the elbow.

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type R and press Enter to specify that you will place the elbow a relative distance.

Toggle/Align/change Ref point/Elev/<Enter Distance or Return for fit-fit>:

Type 19’ {5700} and press Enter to specify the relative distance.

Toggle insertion point/<Return to select>:

Press Enter to accept the default insertion point in the center of the elbow.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type D and press Enter to specify the orientation in the negative-Z direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter again to accept the orientation and place the elbow.

11. Press Enter to re-execute the elbow placement command. Respond to the prompts as follows to place elbow (8) a relative distance form elbow (7) and aligned with the lower elbow in line L1001.

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type T and press Enter to toggle the reference point to the end of the elbow.

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type R and press Enter to specify that you the elbow will be placed relative to the selected port.

Toggle/Align/change Ref point/Elev/<Enter Distance or Return for fit-fit>:

Type A and press Enter to specify that you want to align this elbow to another component.

Pick component to align to:

Pick the lower elbow in line L1001.

Select port to align to:

Toggle/<Enter to select currently highlighted port>:

Press Enter to accept the default port selected.

Toggle insertion point/<Return to select>:

Press Enter to accept the default insertion point at the center of the elbow.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Type E and press Enter to specify the orientation in the positive X direction.

Up/Down/East/West/North/South/Align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter to accept the orientation and place the elbow.

12. You will now connect a flange, gate valve, flange assemble to the horizontal port of elbow (8) just placed. Select Flanges > Weldneck from the Piping menu. Respond to the prompts as follows to place the flange.

Relative/Toggle/Elev/<Pick point or Return for fit-fit>:

Type T and press Enter to toggle the reference point to the other end of the elbow.

Relative/Toggle/Elev.<Pick point or Return for fit-fit>:

Press Enter to accept the insertion point at the horizontal port of the elbow and place the flange.

13. Select Valves > Gate > Gate from the Piping menu, and then press Enter. Press Cancel on the AutoPLANT Selection dialog, to connect the gate valve to the flange face without topworks.

14. Select Flanges > Weldneck from the Piping menu, then press Enter to connect the flange to the valve.

15. Select Bends and Returns > 90o LR Elbow from the Piping menu. Respond to the prompts as follows to connect the up-turning elbow (9) to the weld end of the flange.

Relative/Elev/<Pick point or Return for fit-fit>:

Press Enter to accept the default insertion point at the weld end of the flange.

Up/Down/East/West/North/South/align/Rotate/reseT/<Enter orientation or press Return when done>

Type U and press Enter to specify the orientation of the elbow in the positive-Z direction.

Up/Down/East/West/North/South/align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter to accept the orientation and place the elbow.

16. You will now continue this line from the channel outlet nozzle N4 on the top of exchanger E-107 shell by connecting a flange, then elbow (11). This elbow will be used to align elbow (10) as shown below.

17. Select Flanges > Weldneck from the Piping menu. Pick the shell outlet nozzle E-107-N4, then press Enter to connect the flange to the nozzle.

18. Select Bends and Returns > 90o LR Elbow from the Piping menu. Respond to the prompts as follows to connect elbow (11) to the weldneck flange, rolling the elbow so that it is aligned so that you can place another 90-degree down-turning elbow (10) to connect up with line L1002 that you have been routing.

Relative/Elev/<Pick point or return for fit-fit>:

Press Enter to accept the insertion point at the weld end of the flange.

Up/Down/East/West/North/South/align/Rotate/reseT/<Enter orientation or press Return when done>

Turn Ortho OFF F8, then type CEN and press Enter, then pick the open vertical port of elbow (9).

This will cause the elbow to roll in the direction towards the up-turning elbow.

Up/Down/East/West/North/South/align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter to accept this orientation and place the elbow.

19. Select Bends and Returns > 90o LR Elbow from the Piping menu. Respond to the prompts as follows to place elbow (10) aligned with elbow from the exchanger (11) and the up-turning elbow (9) in line L1002.

Relative/Elev/<Pick point or Return for fit-fit>:

Pick the up-turning end of the up-turning elbow in line L1002. You need to start the insertion from this elbow instead of the elbow near the exchanger in order to be able to align the branch end relative to that elbow.

Current elevation <BOP 115”>

Relative/Elev/<Pick point or Return for fit-fit>:

Type R and press Enter to place this elbow relative to the selected elbow port.

Align/change Ref point/Elev/<Enter distance or Return for fit-fit>:

Type A and press Enter to align this elbow to the exchanger elbow.

Pick component to align to:

Type CEN and press Enter, then pick the open end of the elbow near the exchanger.

Select port to align to:

Toggle/<Enter to select currently highlighted port>:

If necessary, type T and press Enter to toggle the selected reference alignment port to the end of the selected elbow.

When the open end of the elbow is selected, press Enter to accept the port.

Toggle insertion point/<Return to select>:

Press Enter to accept the default insertion point at the center of the elbow.

Up/Down/East/West/North/South/align/Rotate/reseT/<Enter orientation or press Return when done>

Type A and press Enter to align the elbow branch to the exchanger elbow.

Pick component to align to:

Type CEN and press Enter, then pick the open end port of the elbow near the exchanger (11).

Select port to align to:

Toggle/<Enter to select currently highlighted port>:

Press Enter to accept the open port on the end of the elbow.

Up/Down/East/West/North/South/align/Rotate/reseT/<Enter orientation or press Return when done>

Press Enter to accept the selected port and place the elbow.

20. Now that all of the elbows are in place, you can automatically run connecting pipe. Select Pipe Components > AutoPipe from the Piping menu. The AutoPLANT Selections dialog display with the default selection All. Press OK. AutoPipe will automatically find all the aligned ports in your model and place pipe between those ports as shown below.

LESSON 3 BRANCH CONNECTIONS

This Lesson covers the placement of branch components, such as: olets, base elbow supports, etc.

AutoPLANT provides a Tap Ports command that must be executed to designate the component, and the location on the component where the branch component will be placed. A top port must be defined before placing the following component types:

Olets: To place an olet, you must first place a tap port to designate the component on which the olet will be placed. For example, to attach a weldolet to a pipe, you first designate the tap port location.

Elbolets: To place an elbolet, you must first place a tap port at the center port of an elbow.

Base Elbow Supports: To place a base elbow support, you must first place a tap port at the center port of an elbow.

Stub-in branches: To place a stub-in, you must first place a tap port and then place a pipe entity attached to a tapped port on another pipe segment.

Objectives

The objectives of this Lesson are as follows:

• Learn how to define a Tap Port to route a bypass line

• Learn how to place pipe for base support

• Learn how to place an elbolet for base support

Exercise 1 Defining a Tap Port to Route a Bypass Line

In this exercise, you will define a tap port on the vertical pipe segment in Line 1001, upstream from the gate valve, then placed a weldolet and route a 3” {80mm} bypass line as shown below.

1. Select Branching Components > Olets > Tap Port from the Piping menu.

Respond to the prompts as follows to define the tap port.

Pick component to be tapped

Select the base port

Toggle/<Enter to select currently highlighted port>:

If the port at the bottom of the pipe is selected, press Enter to accept that port. Otherwise, type T and press Enter until the bottom port is selected. Press Enter when the bottom port is highlighted to accept the selection.

Toggle base port/Align/change Ref point/<Enter Distance>:

Type 2’-6” {750} and press Enter to specify the tap port location that distance from the bottom pipe port.

The Tap Port Size dialog displays to enable you to define the size.

Select 8” {200} and press OK.

Enter orientation of tap port

Select –Y from the directional aids toolbar to designate an orientation in the horizontal plane.

2. Now that the tap port is defined, you can place the weldolet. Select Branching Components > Olets > Weldolet from the Piping menu. Respond to the prompts as follows to place the weldolet:

Current Elevation/<BOP 115’>

Relative/create taP/Elev/<Pick point or Return for fit-fit>:

Pick the pipe on which the tap port was just defined. PIPING will recognize the previously defined tap port and highlight it.

Relative/create taP/Elev/<Pick point or Return to fit-fit>:

Press Enter to accept the highlighted port.

The Specification Selection dialog displays.

Select the 8x4 {200x100} weldolet and press OK to place the fitting.

3. Connect an elbow to the weldolet with its branch in the negative-X direction, then connect a flange, gate valve (no topworks), and another flange.

4. Create another tap port, in the vertical run of line L1002, aligned with the branch on L1001 as shown above. Place a 8x4 {200x100} weldolet at the tap port location. Attach an elbow in the +X direction, then place connecting pipe between the elbow and flange to complete the bypass line as shown above. Select the Pipe Components > Pipe command and respond to the following prompts:

Current Elevation/<BOP 115’>

Relative/create taP/Elev/<Pick point or Return for fit-fit>

Press Enter to accept the highlighted port Connect to/<Enter Length>:

Type C and press Enter, then pick the open end of the flange to place the pipe.

Exercise 2 Place Elbolet for Base Support

In the previous exercise, you learned how to define a tap port, then place an olet at the tap. In this

In the previous exercise, you learned how to define a tap port, then place an olet at the tap. In this

In document 85182668 AutoPLANT 3D Training(1) (Page 134-146)