Service Training MESX Description of error codes on the ESX control

Status: 06.12.2004

Description of error codes on the ESX control

Page 35 of 48

Author: T. Löw / TE

10.2 Description of error reactions

Error reaction Description of error reaction 1 Warning.

Error code is displayed.

Signal light in BOP (option) lights in 5 second intervals.

2 Function affected, the emergency function overrides the faulty function. Error code is displayed.

Signal light in BOP (option) lights in 5 second intervals.

3 Partial function faulty, overriding of the partial function by the emergency function is not possible .

After the occurrence of the fault the machine is stopped, after returning the travel lever to neutral the machine can move again.

The machine can still be driven to a limited extent, but must be repaired by the service department as soon as possible. Error code is displayed.

Signal light in BOP (option) lights in 5 second intervals.

4 Partial function faulty, overriding of the partial function by the emergency function is not possible . The machine is no longer able to drive, e.g. because parts of the travel system are defective " the diesel engine is shut down.

Error code is displayed.

Signal light in BOP (option) lights in 1 second intervals.

5 Fatal fault. The function of the control can no longer be guaranteed. Control is switched off.

Error code is displayed.

Signal light in BOP (option) lights permanently.

Service Training MESX

Description of error codes on the ESX control

Status: 06.12.2004

Description of error codes on the ESX control

Page 36 of 48

Author: T. Löw / TE

10.3 Detailed description of fault codes and their possible causes

Error code

Description of error Possible cause Terminal

on ESX Input code for diagnose Error reaction 4 5 0 1

Input exciter potentiometer front

The voltage applied to the input is below the specified range (see signal description).

" Wire breakage in current path

" Current path has short circuit to ground " No voltage supply to potentiometer

" Fuse FM ? has tripped or wire breakage in voltage supply current path

" Potentiometer defective

X0:09 5

4 5 0 2

Input exciter potentiometer front

The voltage applied to the input is above the specified range (see signal description).

" Current path connected to +12 V / +8,5 V " Potentiometer not connected to ground " Potentiometer defective

Service Training MESX

Description of error codes on the ESX control

Status: 06.12.2004

Description of error codes on the ESX control

Page 37 of 48

Author: T. Löw / TE Error

code

Description of error Possible cause Terminal

on ESX Input code for diagnose Error reaction 4 5 2 1

Output proportional solenoid front Valve exciter up

Output current too low.

" Current path has short circuit to voltage supply

" Current path has non-permitted connection to another current path

" Current path is interrupted

X0:46 2

4 5 2 2

Output proportional solenoid front Valve exciter up

Output current too high.

" Current path has short circuit to ground

" Current path has non-permitted connection to another current path

X0:46 2

4 5 2 3

Output proportional solenoid front Valve exciter up

Fault when calibrating the valve

" Current path is interrupted

" Current path has unpermitted connection to another current path / ground

X0:46 2

4 5 2 6

Output proportional solenoid front Valve exciter down

Output current too low.

" Current path has short circuit to voltage supply

" Current path has non-permitted connection to another current path

" Current path is interrupted

X0:47 2

4 5 2 7

Output proportional solenoid front Valve exciter down

Output current too high.

" Current path has short circuit to ground

" Current path has non-permitted connection to another current path

X0:47 2

4 5 2 8

Output proportional solenoid front Valve exciter down

Fault when calibrating the valve

" Current path is interrupted

" Current path has impermissible connection to another current path / ground

Service Training MESX

Description of error codes on the ESX control

Status: 06.12.2004

Description of error codes on the ESX control

Page 38 of 48

Author: T. Löw / TE Error

code

Description of error Possible cause Terminal

on ESX Input code for diagnose Error reaction 4 5 3 1

Position controller has reached positive limit The exciter does not move to the desired direction or does not move at all.

" Supply and ground terminals on exciter potentiometer mixed up+

" Valves "exciter up" and "exciter down" mixed up

" MD+ input has 12 V potential, even though the engine is not running X0:09 X0:37 5 0 0 0 2 4 5 3 2

Position controller has reached negative limit The exciter does not move to the desired direction or does not move at all.

" Supply and ground terminals on exciter potentiometer mixed up+

" Valves "exciter up" and "exciter down" mixed up

" MD+ input has 12 V potential, even though the engine is not running X0:09 X0:37 5 0 0 0 2 4 6 0 1

Input acceleration transducer 1

The voltage applied to the input is below the specified range (see signal description).

" Current path has no connection to +12 V / +8,5 V " Current path connected to ground

" Transducer defective X0:29, or X0:31 4 6 0 1 2 4 6 0 2

Input acceleration transducer 1

The voltage applied to the input is above the specified range (see signal description).

" Current path connected to +12 V / +8,5 V " Current path not connected to ground " Transducer defective X0:29, or X0:31 4 6 0 1 2 4 6 0 6

Input acceleration transducer 2

The voltage applied to the input is below the specified range (see signal description).

" Current path has no connection to +12 V / +8,5 V " Current path connected to ground

" Transducer defective X0:30, or X0:07 4 6 0 6 2 4 6 0 7

Input acceleration transducer 2

The voltage applied to the input is above the specified range (see signal description).

" Current path connected to +12 V / +8,5 V " Current path not connected to ground " Transducer defective

X0:30, or X0:07

Service Training MESX

Description of error codes on the ESX control

Status: 06.12.2004

Description of error codes on the ESX control

Page 39 of 48

Author: T. Löw / TE Error

code

Description of error Possible cause Terminal

on ESX Input code for diagnose Error reaction 8 0 0 0

Error message "BOP Software version incorrect" The BOP software version is too old, i.e. various functions cannot be displayed.

This fault cannot be rectified on the machine. The BOP needs to be replaced.

- - 2

8 0 0 1 - 8 9 9 9

Error message „severe software fault in control“ This fault cannot be rectified on the machine. The control must be immediately replaced.

- - - 5

9 0 0 0 - 9 9 9 8

Error message "Communication via CAN Bus disturbed"

The modules controlled via the CAN Bus cannot be addressed by the main control (ESX). The related machine functions are not available

" Wire breakage in CAN Bus lines " Short circuit between CAN Bus lines

" One or both CAN Bus line(s) has (have) connection to +12V or ground

X0:26 X0:27-

- 2

C t 0 Display module has no connection to ESX-

control.

" Wire breakage in CAN Bus lines " Short circuit between CAN Bus lines

" One or both CAN Bus line(s) has (have) connection to +12V or ground

" Bit rate in display module not correct (nominal value: 125 kBit)

X0:26 X0:27