II Parameters 1. User Parameters
bit 1: SYN output
Select whether to send the SYN code to the host if NC resetting or an emergency stop occurs in computer link B.
0: Not output the SYN code.
1: Output the SYN code.
bit 3: DC3 output
Select whether to send the DC3 code to the host when the communication ends in computer link B.
0: Not output the DC3 code.
1: Output the DC3 code.
【#9616】 CTRL. INTERVAL Not used. Set to “0”.
【#9617】 WAIT TIME Not used. Set to “0”.
【#9618】 PACKET LENGTH Not used. Set to “0”.
【#9619】 BUFFER SIZE Not used. Set to “0”.
【#9620】 START SIZE Not used. Set to “0”.
【#9621】 DC1 OUT SIZE Not used. Set to “0”.
【#9622】 POLLING TIMER Not used. Set to “0”.
【#9623】 TRANS. WAIT TMR Not used. Set to “0”.
【#9624】 RETRY COUNTER Not used. Set to “0”.
【#9701(PR)】 IP addr auto set
The IP address is automatically assigned from the server.
0: Manual setting 1: Automatic setting
【#9706】 Host No.
Select the No. of the host to be used from host 1 to host 4.
---Setting range---1 to 4 : Host No.
【#9711】 Host1 host name Set the host computer name.
This parameter allows the NC to easily recognize the host computer on the network. Set the host computer's name (name registered in C:\windows\hosts) or the IP address.
<Setting example>
For host name: mspc160 For IP address: 150.40.0.111
(Note) Set the host computer's TCP/IP address if communication is not carried out correctly.
---Setting
range---15 characters (alphanumeric) or less
【#9712】 Host1 user name
Set the user name when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9713】 Host1 password
Set the password when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9714】 Host1 directory
Set the directory name of the host computer.
The directory released to the client (NC unit) with the host computer's server is handled as root directory by the NC unit.
---Setting
range---31 characters (alphanumeric) or less
【#9715】 Host1 host type
Select the type of the host computer.
0: UNIX/PC automatic judgment 1: UNIX
2: PC (DOS)
(Note) When "0" is set, the settings for the following parameters will be invalid.
- #9716 Wrd pos: name - #9717 Wrd pos: size - #9718 Wrd pos: Dir - #9719 Wrd pos: cmnt - #9720 Wrd num: cmnt
【#9716】 Host 1 Wrd pos: name
Set the file name display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9717】 Host 1 Wrd pos: size
Set the size display position (nth word from left) of the list displayed when the ftp command
"dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9718】 Host 1 Wrd pos: Dir
Set the <DIR> display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9719】 Host 1 Wrd pos: cmnt
Set the comment (date, time, etc.) display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
II Parameters
1. User Parameters【#9720】 Host 1 Wrd num: cmnt
Set the number of words to be displayed as a comment.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9721】 Host 1 no total siz
Set whether to display the total number of characters registered in the machining programs of host1 when displaying the file list.
If there are many files in the directory to be referred to, the list can be updated quickly by setting "1".
0: Display 1: Not display
【#9731】 Host2 host name Set the host computer name.
This parameter allows the NC to easily recognize the host computer on the network. Set the host computer's name (name registered in C:\windows\hosts) or the IP address.
<Setting example>
For host name: mspc160 For IP address: 150.40.0.111
(Note) Set the host computer's TCP/IP address if communication is not carried out correctly.
---Setting
range---15 characters (alphanumeric) or less
【#9732】 Host2 user name
Set the user name when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9733】 Host2 password
Set the password when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9734】 Host2 directory
Set the directory name of the host computer.
The directory released to the client (NC unit) with the host computer's server is handled as the root directory by the NC unit.
---Setting
range---31 characters (alphanumeric) or less
【#9735】 Host2 host type
Select the type of the host computer.
0: UNIX/PC automatic judgment 1: UNIX
2: PC (DOS)
(Note) When "0" is set, the settings for the following parameters will be invalid.
- #9736 Wrd pos: name - #9737 Wrd pos: size - #9738 Wrd pos: Dir - #9739 Wrd pos: cmnt - #9740 Wrd num: cmnt
【#9736】 Host 2 Wrd pos: name
Set the file name display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9737】 Host 2 Wrd pos: size
Set the size display position (nth word from left) of the list displayed when the ftp command
"dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9738】 Host 2 Wrd pos: Dir
Set the <DIR> display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0
【#9739】 Host 2 Wrd pos: cmnt
Set the comment (date, time, etc.) display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9740】 Host 2 Wrd num: cmnt
Set the number of words to be displayed as a comment.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9741】 Host 2 no total siz
Set whether to display the total number of characters registered in the machining programs of host1 when displaying the file list.
If there are many files in the directory to be referred to, the list can be updated quickly by setting "1".
0: Display 1: Not display
【#9751】 Host3 host name Set the host computer name.
This parameter allows the NC to easily recognize the host computer on the network. Set the host computer's name (name registered in C:\windows\hosts) or the IP address.
<Setting example>
For host name: mspc160 For IP address: 150.40.0.111
(Note) Set the host computer's TCP/IP address if communication is not carried out correctly.
---Setting
range---15 characters (alphanumeric) or less
【#9752】 Host3 user name
Set the user name when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9753】 Host3 password
Set the password when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9754】 Host3 directory
Set the directory name of the host computer.
The directory released to the client (NC unit) with the host computer's server is handled as the root directory by the NC unit.
---Setting
range---31 characters (alphanumeric) or less
【#9755】 Host3 host type
Select the type of the host computer.
0: UNIX/PC automatic judgment 1: UNIX
2: PC (DOS)
(Note) When "0" is set, the settings for the following parameters will be invalid.
- #9756 Wrd pos: name - #9757 Wrd pos: size - #9758 Wrd pos: Dir - #9759 Wrd pos: cmnt - #9760 Wrd num: cmnt
【#9756】 Host 3 Wrd pos: name
Set the file name display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9757】 Host 3 Wrd pos: size
Set the size display position (nth word from left) of the list displayed when the ftp command
"dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
II Parameters
1. User Parameters【#9758】 Host 3 Wrd pos: Dir
Set the <DIR> display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9759】 Host 3 Wrd pos: cmnt
Set the comment (date, time, etc.) display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9760】 Host 3 Wrd num: cmnt
Set the number of words to be displayed as a comment.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9761】 Host 3 no total siz
Set whether to display the total number of characters registered in the machining programs of host1 when displaying the file list.
If there are many files in the directory to be referred to, the list can be updated quickly by setting "1".
0: Display 1: Not display
【#9771】 Host4 host name Set the host computer name.
This parameter allows the NC to easily recognize the host computer on the network. Set the host computer's name (name registered in C:\windows\hosts) or the IP address.
<Setting example>
For host name: mspc160 For IP address: 150.40.0.111
(Note) Set the host computer's TCP/IP address if communication is not carried out correctly.
---Setting
range---15 characters (alphanumeric) or less
【#9772】 Host4 user name
Set the user name when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9773】 Host4 password
Set the password when logging into the host computer.
---Setting
range---15 characters (alphanumeric) or less
【#9774】 Host4 directory
Set the directory name of the host computer.
The directory released to the client (NC unit) with the host computer's server is handled as the root directory by the NC unit.
---Setting
range---31 characters (alphanumeric) or less
【#9775】 Host4 host type
Select the type of the host computer.
0: UNIX/PC automatic judgment 1: UNIX
2: PC (DOS)
(Note) When "0" is set, the settings for the following parameters will be invalid.
- #9776 Wrd pos: name - #9777 Wrd pos: size - #9778 Wrd pos: Dir - #9779 Wrd pos: cmnt - #9780 Wrd num: cmnt
【#9776】 Host 4 Wrd pos: name
Set the file name display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0
【#9777】 Host 4 Wrd pos: size
Set the size display position (nth word from left) of the list displayed when the ftp command
"dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9778】 Host 4 Wrd pos: Dir
Set the <DIR> display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9779】 Host 4 Wrd pos: cmnt
Set the comment (date, time, etc.) display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9780】 Host 4 Wrd num: cmnt
Set the number of words to be displayed as a comment.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---0 to 1range---0range---0 0: Default value
【#9781】 Host 4 no total siz
Set whether to display the total number of characters registered in the machining programs of host1 when displaying the file list.
If there are many files in the directory to be referred to, the list can be updated quickly by setting "1".
0: Display 1: Not display
【#10801】 Notice tel num 1
Set the call-back telephone No. used for one-touch call and operator notification.
Begin with the No. from an area code for domestic call.
Begin with a communication company No. for international call.
Hyphens "-" can be used as a delimiting character.
---Setting range---Within 28 characters
【#10802】 Comment 1
Set a comment, such as a party's name, for the notification party telephone No.1.
---Setting
range---Within 20 alphanumerical characters (excluding spaces)
【#10803】 Notice tel num 2
Set the call-back telephone No. used for one-touch call and operator notification.
Begin with the No. from an area code for domestic call.
Begin with a communication company No. for international call.
Hyphens "-" can be used as a delimiting character.
---Setting range---Within 28 characters
【#10804】 Comment 2
Set a comment, such as a party's name, for the notification party telephone No.2.
---Setting
range---Within 20 alphanumerical characters (excluding spaces)
【#10805】 Notice tel num 3
Set the call-back telephone No. used for one-touch call and operator notification.
Begin with the No. from an area code for domestic call.
Begin with a communication company No. for international call.
Hyphens "-" can be used as a delimiting character.
---Setting range---Within 28 characters
II Parameters
1. User Parameters【#10806】 Comment 3
Set a comment, such as a party's name, for the notification party telephone No.3.
---Setting
range---Within 20 alphanumerical characters (excluding spaces)
【#10807】 Password
Set the password for sharing of machining data.
---Setting
range---4 characters (one-byte alphanumeric characters, without space)
【#10808】 Customer number
Set the user No. for sharing of machining data.
---Setting
range---Within 8 characters (one-byte alphanumeric characters, without space)
【#10812】 Anshin-net valid
Select whether to enable the Anshin-net function.
0: Disable 1: Enable
【#10813】 MTBnet enable
Select whether to enable the machine tool builder network system.
0: Disable 1: Enable Standard setting: 0
(Note) Values other than "0" and "1" are invalid.
【#19001】 Syn.tap(,S)cancel
0: Retain the spindle speed (,S) in synchronous tap return 1: Cancel the spindle speed (,S) in synchronous tap return with G80
【#19002】 Zero-point mark
Select the position for displaying the zero point mark in the graphic trace and 2D check.
0: Machine coordinates zero point (same as conventional method) 1: Workpiece coordinate zero point
【#19003】 PRG coord rot type
Select the start point of the initial travel command after G68 command.
0: Calculate the end position using the current position on the local coordinate system before rotating, without rotating the start point in accordance with the coordinates rotation.
1: Calculate the end position, assuming that the start point rotates in accordance with the coordinates rotation.
【#19425】 ManualB Std R1
Set a radius used as standard for the rotary axis speed.
When the setting value of #19425 is larger than that of "#19427 ManualB Std R2", #19425 setting will be used as surface speed control standard radius 2: #19427 setting will be used as surface speed control standard radius 1.
---Setting range---0 to 99999.999 (mm)
【#19426】 ManualB Std F1
This sets the rotary axis speed for surface speed control standard radius 1 (ManualB Std R1).
When the setting value of #19426 is larger than that of "#19428 ManualB Std F2", #19426 setting will be used as surface speed control standard speed 2: #19427 setting will be used as surface speed control standard speed 1.
---Setting range---1 to range---1000000 (°/min)
【#19427】 ManualB Std R2
Set a radius used as standard for the rotary axis speed.
When the same value is set as "#19425 ManualB Std R1", the surface speed control standard speed 1 (ManualB Std F1) will be selected as the rotary axis speed if the radius is less than that value. The surface speed control standard speed 2 (ManualB Std F2) is selected if larger than the set value.
---Setting range---0 to 99999.999 (mm)
【#19428】 ManualB Std F2
Set the rotary axis speed for surface speed control standard radius 2 (ManualB Std R2).
---Setting range---1 to range---1000000 (°/min)
2. Base Specifications Parameters
【#1001(PR)】 SYS_ON System validation setup Select the existence of PLC axes and part systems.
0: Not exist 1: Exist
【#1002(PR)】 axisno Number of axes
Set the number of control axes and PLC axes.
A total of 16 axes can be set.
Control axis: 0 to 8 PLC axis: 0 to 2
When set to “0”, the number of control axes in the part system will be “0”. Do not set the number of control axes of the first part system to “0”.
(Note) The setting range differs according to the model.
【#1003(PR)】 iunit Input setup unit
Select the input setting value for each part system and the PLC axis.
Increments in parameters will follow this selection.
B : 1 µm C : 0.1 µm D : 0.01 µm (10nm) E : 0.001 µm (1nm)
【#1004(PR)】 ctrl_unit Control unit
Select the control increment for each part system and PLC axis.
Select the increment for the NC internal position data, communication data between the NC and drive unit, and the servo travel data. Increments for some parameters, such as the pitch error and backlash, will follow this selection.
B : 1 µm C : 0.1 µm D : 0.01 µm (10nm) E : 0.001 µm (1nm)
【#1005(PR)】 plcunit PLC unit
Select the PLC interface setting and display increment.
The PLC interface setting and display increment will follow this specification. Note that the PLC axis will follow “#1003 iunit”.
B : 1 µm C : 0.1 µm D : 0.01 µm (10nm) E : 0.001 µm (1nm)
【#1006(PR)】 mcmpunit Machine error compensa-tion unit
Select the machine error compensation setting and display increment.
The parameters related to machine error compensation (backlash, pitch error compensation, etc.) and PLC interface (external machine coordinate system compensation) will follow this selection.
B : 1 µm C : 0.1 µm D : 0.01 µm (10nm) E : 0.001 µm (1nm)
【#1007(PR)】 System type select System type select Select the NC system type.
0: Machining center system (M system) 1: Lathe system (L system)
(Note 1) If the setting value is out of range, M system will be selected.
(Note 2) This parameter is exclusively for 70 series. 700 series doesn’t support this parameter.
【#1010(PR)】 srvunit Output unit (servo)
Select the output increment to servo. The standard value is “E”.
B : 1 µm C : 0.1 µm D : 0.01 µm (10nm) E : 0.001 µm (1nm)
【#1013(PR)】 axname Axis name
Set each axis’s name with an alphabetic character.
Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C.
(Note 1) Do not set the same name twice in one part system. The same name which is used in another part system can be set.
(Note 2) The PLC name does not need to be set. (The axis name is displayed as 1 and 2.) ---Setting
range---X, Y, Z, U, V, W, A, B, C