Chapter 6. Operating system and management software
6.2 Management software
6.2.3 System Director agent
The IBM Director platform system agents serve as the control point for surfacing hardware events and information. These agents, in conjunction with the IBM Hardware Management Pack for SCOM 2007 R2, can be discovered and managed by Microsoft System Center Operations Manager Server.
Visit the following site for information about downloading Upward Integration Module agents:
© Copyright IBM Corp. 2011. All rights reserved. 31
Appendix A.
System x rack and power options
Figure A-1 shows the rack and power options that are available for IBM System x servers.
Figure A-1 System x rack and power choices
A
Racks
UPSs
PDUs
KVM/consoles
42U and 47U deep racks Optional Network Management Card
Optional Environmental Monitoring Probe
1000VA LCD Tower UPS 1500VA LCD Tower UPS 1500VA LCD 2U Rack UPS 2200VA LCD 2U Rack UPS 3000VA LCD 3U Rack UPS 6000VA LCD 4U Rack UPS
0U 24 C13 PDUs 0U 12 C13/12 C19 PDUs 1754D1X IBM Global 2x2x16 Console Manager (GCM16) 46M5382 IBM Serial Conversion Option (SCO)
46M5383 IBM Virtual Media Conversion Option Gen2
(VCO2)
1754D2X IBM Global 4x2x32 Console Manager (GCM32)
1754-A2X IBM Local 2x16 Console
Manager (LCM16) 1754-A1X IBM Local 1x8 Console Manager
Table A-1 show the common rack and power items used in the IBM Reference Configuration for Microsoft Private Cloud offerings.
Table A-1 IBM Reference Configuration rack and power parts list
Part number Description Quantity
1754D1X IBM Global 2x2x16 Console Manager 1
46M5383 IBM Virtual Media Conversion Option VCO2 11
172319X 1U 19 inch Flat Panel Monitor Console Kit with DVD 1
40K5372 IBM Keyboard with Integrated Pointing Device 1
46M4004 IBM 1U 12 C13 Switched and Monitored DPI PDU 4
40K9614 IBM DPI 30A Cord (NEMA L6-30P) 4
© Copyright IBM Corp. 2011. All rights reserved. 33
Appendix B.
Parts lists
This appendix lists the parts for the various components of the IBM Reference Configuration for or Microsoft Private Cloud solution. It includes the following sections:
Compute/production node parts list
Management server parts list
Active Directory server parts list
Compute/production node parts list
Use the parts in Table B-1 to help you order the compute/production node cluster components.
Table B-1 IBM Reference Configuration compute/production node configuration parts list
Management server parts list
The pair of servers described in 3.3, “Management node for System Center Virtual Machine Manager” on page 10 constitutes a management cluster configuration that provides reliability and fault tolerance.
Each of the two management servers uses the following components:
IBM System x3650 M3
Two Intel Xeon X5670 processors: 6C 2.93 GHz 12 MB Cache 1333 MHz 95w
48 GB RAM (composed of six 8 GB DIMMs)
One ServeRAID M1015 SAS/SATA Controller (optional battery not included)
Two IBM 73 GB 15K 6 Gbps SAS 2.5 inch SFF Slim-HS disk drives
Two Brocade 10 Gb Dual Port CNAs
Part number Description Quantity
7945-AC1 IBM System x3650 M3 w/ 2.93 GHz 6C Processor 8
46M1087 2nd 2.93 GHz 6C Processor 8
44X0138 PCI-Express (2 x8 slots; 1 FH/FL, 1 LP) Riser Card 1 8
46M1131 PCI-Express (2 x8 slots; 1 FH/FL, 1 FH/HL) Riser Card 2 8
49Y1397 8 GB (1x 8 GB, 2Rx4, 1.35 V) PC3-10600 CL9 ECC DDR3 1333 MHz LP RDIMM 96
46M0831 ServeRAID M1015 SAS/SATA Controller 8
46M1075 IBM 675 W Redundant Power Supply 8
42C1820 Brocade 10 Gb CNA for IBM System x 16
42D0632 IBM 146 GB 10K 6 Gbps SAS 2.5" SFF Slim-HS HDD 16
46C7526 Virtual Media Key 8
4849MGN MS Windows Srv 2008 R2 Datacenter (2 CPU,5 UserCAL) ROK-ML (BR,EN,FR,SP) 8 39Y5533 2.8 m, 10 A/100-250 V, C13 to IEC 320-C14 Rack Power Cable 16
Appendix B. Parts lists 35
Table B-2 provides parts ordering information for the management nodes for the IBM reference configuration.
Table B-2 Management node parts list for the IBM Reference Configuration for Cloud
Active Directory server parts list
Table B-3 provides parts ordering information for the Active Directory.
Table B-3 Active Directory server parts list
Part number Description Quantity
7945-AC1 IBM System x3650 M3 w/ 2.66 GHz 4C Processor 2
44E5181 2nd 2.66 GHz 6C Processor 2
44X0138 PCI-Express (2 x8 slots; 1 FH/FL, 1 LP) Riser Card 1 2
46M1131 PCI-Express (2 x8 slots; 1 FH/FL, 1 FH/HL) Riser Card 2 2
49Y1397 8 GB (1x 4 GB, 2Rx4, 1.35 V) PC3-10600 CL9 ECC DDR3 1333 MHz LP RDIMM 12
46M0831 ServeRAID M1015 SAS/SATA Controller 2
46M1075 IBM 675 W Redundant Power Supply 2
42C1820 Brocade 10 Gb CNA for IBM System x 4
42D0634 IBM 146 GB 10K 6 Gbps SAS 2.5" SFF Slim-HS HDD 4
46C7526 Virtual Media Key 2
4849MTN MS Windows Srv 2008 R2 Enterprise (1-8 CPU,10 CAL) ROK-ML (BR,EN,FR,SP) 2
39Y5533 2.8 m, 10 A/100-250 V, C13 to IEC 320-C14 Rack Power Cable 4
Part number Description Quantity
7944-AC1 IBM System x3550 M3 w/ 2.66 GHz 4C Processor 1
46C0594 2 GB (1x 2 GB, 2Rx8, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 MHz LP RDIMM 3
46M0831 ServeRAID M1015 SAS/SATA Controller 1
42D0632 IBM 146 GB 10K 6 Gbps SAS 2.5" SFF Slim-HS HDD 2
46C7526 Virtual Media Key 1
46M1075 IBM 675 W Redundant Power Supply 1
4849MSN MS Windows Srv 2008 R2 Standard (1-4 CPU,5 CAL) ROK-ML (BR,EN,FR,SP) 1
© Copyright IBM Corp. 2011. All rights reserved. 37
Appendix C.
Ordering options for the IBM XIV
Storage System
The IBM XIV Storage System Gen3 model shown in Figure C-1 is ordered according to the capacity required. The minimum physical installation is six data modules yielding 55 TB of usable storage (there is also a Capacity on Demand (CoD) plan allowing a three-module 28 TB minimum entry point). Although 28 TB is the minimum configuration for the XIV system using CoD, it is appropriate only for storage requirements that grow to at least 55 TB in a one to three-year period.
Figure C-1 XIV Storage System Gen3 model internal components
C
FC iSCSI Inter-module Connectivity Host Host Host15 data modules, each containing:
• 12 high-density SAS disk drives • 24 GB memory
• Quad-core Intel CPU
• 2 x 20 Gbps InfiniBand HCA ports
Host connectivity:
• 24 x 8 Gbps FC ports • 22 x 1 Gbps iSCSI ports
2 InfiniBand switches:
• Redundant inter-module connectivity • 600 Gbps total internal bandwidth
3 UPS modules:
• Stable power to all system components
• Safe shutdown upon power outage
Cache CPU Interface Disks UPS Data Module Data Module UPS UPS Data Module Data Module
Each XIV system includes all of the following software at no additional cost:
Thin provisioning
Snapshots
Sync and async replication
“Host connection” software
Fibre Channel connectivity
ISCSI connectivity
Performance monitoring
Migration software
Basically, all XIV systems include all XIV features, and there are no “options” or additional software features that must be ordered.
Initial configuration options for the IBM Storage System XIV Gen2 and Gen3 models are shown in Table C-1.
Table C-1 Configuration options for XIV Storage System Gen3 models
If ordered initially with less than 15 data modules, the XIV system Gen3 model can be upgraded using the increments in Table C-1. Additional capacity, processing, connectivity, and cache can all be created as needed without disruption or performance impact.
Capacity on demand (CoD)
With the CoD ordering option for the XIV system Gen3 model, customers benefit from the full processing, caching, and drive spindle performance of the physically deployed system, yet only the minimum necessary capacity must be ordered initially.
The minimum usable capacity purchased in a CoD configuration is 28 TB (other initial increments are available). This minimum entry point consists of three CoD data modules and three CoD I/O data modules. As shown in Figure C-2 on page 39, this configuration provides 28 TB of purchased capacity and 27 TB of in-place expansion.
Number of XIV data modules 6 9 10 11 12 13 14 15
Number of disks 72 108 120 132 144 156 168 180
Usable capacity TBs (2 TB drives) 55 88 102 111 125 134 149 161
Usable capacity TBs (3 TB drives) 84 132 154 168 190 203 225 243
Fibre Channel (FC) ports (8 GB) 8 16 16 20 20 24 24 24
Processors (Quad core) 6 9 10 11 12 13 14 15
Gen2 Memory (GB) 96 144 160 176 192 208 224 240
Appendix C. Ordering options for the IBM XIV Storage System 39
Although there is a slight premium per usable TB for CoD options, the performance of CoD purchased capacity benefits from the additional processor, memory, FC ports, and spindles in a base 55 TB configuration.
Figure C-2 Available in-place upgrade with CoD
For more information about the CoD program, terms, and conditions, contact your IBM representative or authorized partner.