3.1.141 TempP1, TempP2, TempP3, and TempP4

In document Troubleshooting_Manual[1].pdf (Page 170-175)

Troubleshooting instructions

1 Check if the shelf containing the affected card has raised a Fan alarm: FNLOW, FNLOWM, FNUPP, or FNUPPM, and troubleshoot any such alarm first.

2 If the TempP# alarm persists, check the ambient temperature around the shelf. It must be lower than 50°C (122°F) or as otherwise quoted in the official SURPASS hiT 7500 product specifications.

3 Contact your next level of technical support before proceeding since the following action is traffic-affecting. If no other cause can be found, Warm Start the card raising the alarm. If the TempP# alarm persists after Warm Start recovery time (approx 3 minutes), Cold Start the card. If the TempP# alarm persists after Cold Start recovery time (approx 3 minutes), the card is defective. Replace the affected card with a spare.

Alarm name Temperature Problem VOA (TempPVOA) Default severity Minor

Alarm object TSC card General information

and causes

A TempPVOA alarm is raised if the temperature on the indicated card is too high.

Alarm name Temperature Problem # (TempP#) Default severity Major

Alarm object OCA and OCAS cards.

General information and causes

A TempP# alarm is raised if the temperature on the indicated card is too high.

A42022-L5961-L081-03-7619 Issue: 3 Issue date: August 2008

171

3.1.142 TempRegRun

Troubleshooting instructions

1 Check if the shelf containing the affected card has raised a Fan alarm: FNLOW, FNLOWM, FNUPP, or FNUPPM, and troubleshoot any such alarm first.

2 If the TempRegRun alarm persists, check the ambient temperature around the shelf.

It must be lower than 50°C (122°F) or as otherwise quoted in the official SURPASS hiT 7500 product specifications.

3 Contact your next level of technical support before proceeding since the following action is traffic-affecting. If no other cause can be found, Warm Start the card raising the alarm. If the TempRegRun alarm persists after Warm Start recovery time (approx 3 minutes), Cold Start the card. If the TempRegRun alarm persists after Cold Start recovery time (approx 3 minutes), the card is defective. Replace the affected card with a spare.

3.1.143 TimP

Troubleshooting instructions

1 Is traffic affected due to the TimP condition?

Yes: Warm Start the card raising the TimP alarm. Sometimes, this allows a failed card to recover. Note however, that the recovery is often only temporary.

If the Warm Start does not clear the alarm, Cold Start the card. If the Cold Start does not clear the alarm, immediately replace the failed card with a spare.

No: Warm Start the card raising the TimP alarm. Sometimes, this allows a failed card to recover. Note however, that the recovery is often only temporary. If the Warm Start does not clear the alarm, do NOT execute a Cold Start. Wait for the next scheduled maintenance window to replace the faulty card.

2 If the alarm persists, contact your next higher level of technical support.

Alarm name Temperature Regulation Running (TempRegRun) Default severity Warning

Alarm object Raman cards General information

and causes

A TempRegRun alarm is raised if the temperature on the indicated card is too high.

The TimP alarm is raised if the precision oscillator on the indicated OSCT card fails.

172 A42022-L5961-L081-03-7619 Issue: 3 Issue date: August 2008

3.1.144 TSCh1TD

Troubleshooting instructions

1 The TSCh1TD alarm serves as an advance warning that a TSCh1TF alarm might soon occur. Immediate replacement of the card is not necessary. However, TSC card replacement should be scheduled for the next convenient maintenance period.

3.1.145 TSCh2TD

Troubleshooting instructions

1 The TSCh2TD alarm serves as an advance warning that a TSCh2TF alarm might soon occur. Immediate replacement of the card is not necessary. However, TSC card replacement should be scheduled for the next convenient maintenance period.

3.1.146 TSCh3TD

Alarm name Transmit Degrade TSCh1 (TSCh1TD) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh1TD alarm will be raised if the Transient Suppression Channel 1 laser current has degraded.

Alarm name Transmit Degrade TSCh2 (TSCh2TD) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh2TD alarm will be raised if the Transient Suppression Channel 2 laser current has degraded.

Alarm name Transmit Degrade TSCh3 (TSCh3TD) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh3TD alarm will be raised if the Transient Suppression Channel 3 laser current has degraded.

A42022-L5961-L081-03-7619 Issue: 3 Issue date: August 2008

173 Troubleshooting instructions

1 The TSCh3TD alarm serves as an advance warning that a TSCh3TF alarm might soon occur. Immediate replacement of the card is not necessary. However, TSC card replacement should be scheduled for the next convenient maintenance period.

3.1.147 TSCh4TD

Troubleshooting instructions

1 The TSCh4TD alarm serves as an advance warning that a TSCh4TF alarm might soon occur. Immediate replacement of the card is not necessary. However, TSC card replacement should be scheduled for the next convenient maintenance period.

3.1.148 TSCh1TF

Troubleshooting instructions

1 Warm Start the card raising the TSCh1TF alarm. Sometimes, this allows a failed card to recover. Note however, that the recovery is often only temporary. If the Warm Start does not clear the alarm, Cold Start the card. If the Cold Start does not clear the alarm, TSC card replacement should be scheduled for the next convenient main-tenance period.

3.1.149 TSCh2TF

Alarm name Transmit Degrade TSCh4 (TSCh4TD) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh4TD alarm will be raised if the Transient Suppression Channel 4 laser current has degraded.

Alarm name Transmit Fail TSCh1 (TSCh1TF) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh1TF alarm will be raised if the Transient Suppression Channel 1 laser has failed.

Alarm name Transmit Fail TSCh2 (TSCh2TF) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh2TF alarm will be raised if the Transient Suppression Channel 2 laser has failed.

174 A42022-L5961-L081-03-7619 Issue: 3 Issue date: August 2008 Troubleshooting instructions

1 Warm Start the card raising the TSCh2TF alarm. Sometimes, this allows a failed card to recover. Note however, that the recovery is often only temporary. If the Warm Start does not clear the alarm, Cold Start the card. If the Cold Start does not clear the alarm, TSC card replacement should be scheduled for the next convenient main-tenance period.

3.1.150 TSCh3TF

Troubleshooting instructions

1 Warm Start the card raising the TSCh3TF alarm. Sometimes, this allows a failed card to recover. Note however, that the recovery is often only temporary. If the Warm Start does not clear the alarm, Cold Start the card. If the Cold Start does not clear the alarm, TSC card replacement should be scheduled for the next convenient main-tenance period.

Alarm name Transmit Fail TSCh3 (TSCh3TF) Default severity Minor

Alarm object TSC card General information

and causes

A TSCh3TF alarm will be raised if the Transient Suppression Channel 3 laser has failed.

A42022-L5961-L081-03-7619 Issue: 3 Issue date: August 2008

175

3.1.151 TSCh4TF

Troubleshooting instructions

1 Warm Start the card raising the TSCh4TF alarm. Sometimes, this allows a failed card to recover. Note however, that the recovery is often only temporary. If the Warm Start does not clear the alarm, Cold Start the card. If the Cold Start does not clear the alarm, TSC card replacement should be scheduled for the next convenient main-tenance period.