• No results found

THRU 8 EXIT

In document nastran error list (Page 80-200)

Delete the next 3 lines which invoke the SOS editor. Known Error CR 2319

Corrected Version 69

Abstract Static Analysis - PLOAD1 and SORT2 - Wrong Answers

Description

In SOL 24, the effects of distributed loading with PLOAD1 are not reflected in the element stress and force

output in the SORT2 format. The fix to this error requires changes to the SOL 24 DMAP which would necessitate all

user DMAPs to be modified. Since there are several possible avoidances it has been decided that it is in the

user's best interest to maintain the upward compatibility of the user's DMAPs and leave this error as a general

limitation.

One avoidance is to use SOL 61 or SOL 101. An alternate avoidance is to apply the following DMAP alter.

compile sol24 souin=mscsou noref nolist alter 176 SDRX CASECC,OEF1,OES1,GEOM2,GEOM3,EST,CSTM,MPT,DIT/ OEF1X,OES1X/S,N,NOX $ alter 178,178 SDR3 OUGV1,OPG1,OQG1,OEF1X,OES1X,/OUGV2,OPG2,OQG2,OEF2,OES Known Error CR 2322 Product MSC / MD Nastran Corrected Version GL

Abstract Documentation - MSGMESH Analyst's Gu - Incorrect Documentation

Description

On page 3-3 in the MSGVIEW portion of the MSGMESH Analyst's Guide, it states

that MSGVIEW plot sets are

printed in the the MSGMESH output. This print option was removed prior to the release of MSC/NASTRAN Version 64.

Known Error CR 2330

Product MSC / MD Nastran Corrected Version 69

Abstract Random Response Analysis - RANDPS - SWM 3002, Missing Output

Description

If multiple RANDPS entries appear in the Bulk Data with the same set identification

number (SID) and the

same subcases specified for J and K, then SWM 3002 will be issued and random

analysis data recovery will not be completed. A correction to this error was integrated into Version 65B and later systems but the fix is incorrect. The incorrect fix results in UFM 5418 whenever duplication of fields J,

Known Error CR 2330

K and X is encountered on any RANDPS entry. The code should check for duplication

of SID, J, and K.

This error has been corrected in Version 69.

Avoidance: An avoidance for systems prior to Version 65B is to specify unique SIDs for each RANDPS entry. In Version 65B and later systems the avoidance is to modify the X value (field 5) whenever there

are duplicates across fields 3,4, Known Error CR 2341

Product MSC / MD Nastran Corrected Version GL

Abstract Geometric Nonlinearity (SOL 64 - Follower Forces, SPC - Wrong Answers

Description

In SOL 64, follower forces are computed using the load requests of

the present iteration and the geometry of the previous iteration. However, the geometric effects on follower forces, implied by a SPCD request, is not reflected until the next iteration.

There is no known avoidance. Known Error CR 2375

Product MSC / MD Nastran Corrected Version 69

Abstract Documentation - XYPLOT, CDAMPi,CVISC - Missing Plot Output

Description

In the documentation for XYPLOTS, User's Manual Section 4, it implies the CDAMPi AND CVISCi elements are

treated exactly the same as CELASi AND CONROD elements, respectively for plot requests. However, General

Limitation 2028 states: "For modal formulations, element force output requests

for CVISCi and CDAMPi elements are

ignored, if the matrix method of data recovery is used." An avoidance is given for this General Limitation and is

applicable for XYPLOT output requests.

Avoidance: An avoidance is to request the mode displacement method by including PARAM,DDRMM,-1 in the Bulk

Data Deck. The XY output for damping and elastic elements must be requested

Product MSC / MD Nastran Corrected Version 66

Abstract Nonlinear Analysis - Follower Forces - Wrong Answers

Description

This error is related to Error 2237 but it occurs for all follower

force type loads, including thermal loads, in SOL 66. Wrong answers are produced when a stiffness matrix update and new load factor are computed simultaneously. This is likely to happen with the ITER (LSQN) and SEMI (SEMIQN) methods, since stiffness matrix updates are prescribed by these methods.

Avoidance: A possible avoidance is to use the AUTO method (with a large KSTEP, e.g., 20) to prevent any

stiffness matrix updates from occurring. Known Error CR 2378

Product MSC / MD Nastran Corrected Version GL

Abstract Eigenvalue Analysis - Lanczos - Unexplainable User Message

Description

If the Lanczos method is used for an eigenvalue analysis, the following termination message may be issued in

the eigenvalue analysis summary: NOT ALL EIGENVALUES FOUND IN RANGE. This

message is given when three consecutive shifts have failed to produce any new eigenvalues. (V65 only)

Avoidance: There is no known avoidance. The user should try rerunning the problem with a different frequency range in order to force the shift algorithm to select a different series of shift values. Please refer to Error 2571 for a related error.

Known Error CR 2383

Product MSC / MD Nastran Corrected Version 68

Abstract Heat Transfer - GP1 - UFM 2012

Description

Superelement solution sequences 74 and 89 fail to accept upstream superelements

when an SPOINT entry exists.

Avoidance: The avoidance is to change all SPOINT type entries to GRIDS entries.

Known Error CR 2388

Product MSC / MD Nastran Corrected Version 66

Abstract Documentation - - NASTRAN Will Not Execute

Description

VAX must have VMS 4.0 Operating System or greater in order to run MSC/65.

Avoidance: If clients have VMS 3.X Operating System installed and want to leave it at 3.X, they should use MSC/64. (VAX V65 only)

Known Error CR 2393

Product MSC / MD Nastran Corrected Version 69

Abstract Differential Stiffness and Buckling - GPSTR2 - Divide by zero

Description

If in SOL 5 a grid point stress output request is made above the subcase level, a machine dependent error

indicating divide by zero will be issued. (V65 only)

Avoidance: Grid point stress output requests should be placed within the first subcase only. In Version 66,

the user should use SOL 105. Known Error CR 2406

Product MSC / MD Nastran Corrected Version 70.5

Abstract Dynamic Response Analysis - SDAMPING - Wrong Answers, Missing Messages

Description

The SDAMPING Case Control command can select only one entry in the superelement

sequences. No warning

messages are issued that any subsequent SDAMP requests are being ignored.

The solution uses the initial SDAMP

request and produces plausible but wrong results. UM 2.3 description of the command has a qualified remark

directing the user to include multiple FREQ requests which needs a further qualification to indicate that it

applies only to the Rigid Formats. MSC/NASTRAN Version 68 will be enhanced

to support multiple SDAMP entries.

Solution

Sequences Unstructured or

Structured, then multiple restarts must be employed. Known Error CR 2414

Product MSC / MD Nastran Corrected Version 69

Abstract Transient Analysis - SOLs 27,31,69,72,109,112 - SORT1 Output Unavailable

Description

When performing either Direct Transient Response, SOL 27, or Modal Transient Response, SOL 31, if SORT1 output is requested SORT2 output will be obtained.

Avoidance: Either SOL 69 or 109 with PARAM,CURVPLOT,1 or SOL 72 or 112 with PARAM,CURVPLOT,1 and

PARAM,DDRMM,-1 may be substituted for SOL 27 and SOL 31 respectively. Else

one of the following alters must be included depending on the solution and PARAM,DDRMM option requested:

ALTER 449 $ SOL 27 JUMP LSORT1 $ ALTER 477,478 $ ALTER 481,481 $

ALTER 557 $ SOL 31 WITH DDRMM=-1 JUMP LSORT1 $

ALTER 586,586 ALTER 588,588

ALTER 524 $ SOL 31 WITH DDRMM=0 (DEFAULT) JUMP LBLDRM1 $ ALTER 586,586 $ ALTER 588,588 $ Known Error CR 2432 Product MSC / MD Nastran Corrected Version 70

Abstract Hydroelastic Analysis - VECPLOT/PLOT - SFM 4276

Description

If determination of the differential stiffness matrix is desired in a SOL 64 run with hydroelastic elements

present in the model, SFM 4276, Recovery Code 7777 will occur in the VECPLOT

Known Error CR 2432

and PLOT modules.

Avoidance: The following alter must be included to avert this problem. $ --- FOR MSC/64 & MSC/65 ---

$ MODIFIES THE SIL AND BDPDT TABLE FOR HYDROELASTIC ALTER 44,44 $ UNDEFORMED SHAPE PLOT

PLTTRAN GBGPDT,GSILS/BGPDP,SIP/V,N,LUSET/S,N,LUSEP $ TABPT BGPDP,SIP,GBGPDT,GSILS, // $

PLOT PLTPAR,GPSETS,ELSETS,CASECC,BGPDP,GEQEXINS,SIP,, GECTS,,/ PLOTX1/NSILS/LUSEP/S,N,JUMPPLOT/1/S,N,PFILE $

$

ALTER 163,163 $ FOR VECPLOT PL

Known Error CR 2443

Product MSC / MD Nastran Corrected Version 69

Abstract Frequency Response and Random - RANDOM - SFM 3002

Description

If in Random Analysis the referenced RANDPS entry references subcases that do not exist, SFM 3002 will be

issued indicating an EOF has been reached.

Avoidance: The user should check his input to insure the referenced subcases exist. If the user is using

superelements or attempting random analysis of the solution set, please refer to error numbers 2431 and 2471 for additional information.

Known Error CR 2452

Product MSC / MD Nastran Corrected Version 66

Abstract Miscellaneous - MCE1 - UFM 5303

Description

In MSC/NASTRAN II, if the [Rmm] matrix which defines the multipoint constraint equations is not diagonal, the

UDCOMP subroutine which is not available in MSC/NASTRAN II will be called resulting in UFM 5303.

Avoidance: In the coding of rigid elements the user can avoid off diagonal terms in the [Rmm] matrix by not

specifying degrees of freedom as dependent on one rigid element and independent

on another. In most practical

applications, this error cannot be avoided for the RBE3 element. Known Error CR 2462

Product MSC / MD Nastran Corrected Version 68

Abstract Documentation - Handbook for Superelement Analysis - Comp. Mode Synthesis

Description

The Handbook for Superelement analysis, Section 3.1.10, references an MSC "internal document" on component

mode synthesis. This document is now available as MSR-71, and may be ordered

in the same manner as other user

documentation. The decks for the examples referred to in Section 4.1 and 4.2 of MSR-71 will be included on the

delivery tape in Version 67.5 and later systems and will be named COMP4P1*.DAT

and COMP42*.DAT. However, the

method described in MSR-71 which utilizes SOL 41, 42, and 43 is no longer the preferred approach for component mode synthesis. These solutions are no longer maintained. The preferred approach is documented in a paper presented

at the 1990 World User's Conference entitled "Creation of and use of "Craig- Bampton"

Models using MSC/NASTRAN" written b Known Error CR 2471

Product MSC / MD Nastran Corrected Version GL

Abstract Frequency Response and Random - RANDOM - Wrong Answers

Description

Error 2423 and General Limitation 1602 instruct the user to duplicate requests

for random analysis of the solution set in SOL 71, once as a solution set request, ie. SDISP, and once as a nonsolution set request, ie. DISP. However, when more than one subcase is involved on the related RANDPS Bulk Data entry,

the PSDF results will incorrectly be that of only one subcase.

Avoidance: To get proper results the user must strictly adhere to the following

procedure:

1. You must make a case control request for the solution set variables desired, SDISP, SVELO or SACCE, with the SORT2 modifier. Physical output requests should not be included within the same run.

Known Error CR 2471 the ph Known Error CR 2496

Product MSC / MD Nastran Corrected Version 70

Abstract Documentation - HBDA, Dynamic Reduction - Poor Answers

Description

Documentation for the use of GDR, section 4.1 of the Handbook for Dynamic Analysis, instructs the user to use the defaults for NQDES, NIRV, and NIT, else accuracy or efficiency penalties will be experienced. It assures the user that all vibration modes below FMAX will be computed accurately if these procedures are followed. Although these recommendations are valid for most models, investigations have revealed models where these defaults are not adequate. This topic is discussed further in Section 5.1 of the Handbook for Dynamic Analysis. Models with many closely spaced roots and/or

a large number of roots requested are particularly susceptible to missed roots and loss of accuracy. The user should be aware that there are limitations

to the method and the number of accurate roots is dep Known Error CR 2503

Product MSC / MD Nastran Corrected Version 67.5

Abstract Aeroelastic Analysis - FA2 - SFM 3003

Description

In SOL 75 using the KE flutter method, piston theory aerodynamics, SFM 3003 will be encountered in the FA2

module. (IBM only)

Avoidance: No known avoidance is available. Known Error CR 2515

Product MSC / MD Nastran Corrected Version 69

Abstract Elements - BEND - Wrong Answers

Description

If the alternate form of the PBEND card is used and FSI is set to 2 or 3, incorrect answers will result.

FSI=2 will produce incorrect stresses. Whereas, FSI=3 applies a flexibility correction factor for a curved pipe under pressure rather than an equivalent straight pipe. This leads to poor answers for displacements.

Furthermore, the location of the four points chosen for stress output as documented in Section 1.3 of the User's Manual may not be the maximum stress

Avoidance: Other than using FSI set to 1, there is no known avoidance. Known Error CR 2554

Product MSC / MD Nastran Corrected Version 67

Abstract Geometric Nonlinearity (SOL 64 - - SFM 4275, SFM 4276

Description

Requests for displacements output only in a SOL 64 run may result in "SFM 4275 DURING A DB READ OPERATION"

followed by "SFM 4276 IONAST EC 1302". (Apollo V65, CRAY X-MP/COS V65A

only)

Avoidance: This problem is not yet fully understood. However, a request for additional output such as

SPCFORCE and ELFORCE in conjunction with the DISP request has averted the

problem on both machines where the problem has been discovered.

Known Error CR 2583

Product MSC / MD Nastran Corrected Version GL

Abstract Material Nonlinearity - NLITER - UWM 5409, UFM 4553, 4542

Description

If in material nonlinear analysis the structure is not subjected to any mechanical loads but is subjected to thermal loads, UFM 4542: NO LOAD INCREMENT

EXISTS FOR NONLINEAR SUBCASE may be output. This is a limitation of the design and will happen whenever the temperature loads cause no loads to be passed down to the l-set. For example, a symmetric flat plate supported on all sides or a simple beam supported on both ends subjected to only thermal

loads will produce the fatal message.

A possible alternative to UFM 4542 is some noise loads get passed down to the l-set and job will fail with

maximum number of bisections or minimum load step has been reach. Avoidance: If the fatal message is obtained, a small dummy mechanical load will have to be applied.

Known Error CR 2588

Known Error CR 2588 Corrected Version GL

Abstract Elements - CBAR,CBEAM - Poor Answers

Description

If the orientation vector for a CBAR or CBEAM element is defined nearly parallel with the elements axis, UFM 2026 may fail to appear. The resulting element coordinate system may be randomly defined, which may result in poor

answers depending on the section properties of the element. Avoidance: The user should ensure that the orientation vectors are at an angle of at least one degree from the element axis so as not to introduce

numerical difficulties in the problem. In Version 66 this error message has been changed to UWM 5464 or 5487 which will be issued whenever the orientation

angle is less than one degree. In Version 66 if the orientation angle is exactly zero, then the job will eventually fail. Some machines may issue SFM 4276 EC 7777 in the output, however, other may

Known Error CR 2609

Product MSC / MD Nastran Corrected Version 69

Abstract Plotting - PLTVEC,SEUPPLOT - PACKUNPK FM 211

Description

The SEUPPLOT feature may not be reliable for large models and multi-level superelement decks. Observed

problems include: PACKUNPK FATAL MESSAGE 211 in the PLTVEC module, missing

plot output, and incorrect deformed plots. In most cases the aforementioned

fatal message will occur as the result of an improper restart. The problem is not yet fully understood and users are request to forward problem data decks to MSC.

Avoidance: The user may be able to avoid difficulties by plotting one superelement

at a time using SEPLOT.

The scale information output by the PLOT module may be useful in obtaining plots of individual superelements that are to a compatible scale.

Known Error CR 2612

Product MSC / MD Nastran Corrected Version 70

Abstract Documentation - Application Manual,S - UWM 4591

command

format. The OUTPUT parameter shown in field four is not a legal parameter. Use of this parameter on the SURFACE command will result in UWM 4591, ILLEGAL

PARAMETER SPECIFICATION ON A SURFACE OR VOLUME CARD. This documentaion

has been superseded by the Quick Reference Guide. The SURFACE command as

well as all other plot commands are now documented in the QRG.

Avoidance: Remove the OUTPUT parameter from the SURFACE command format

description in the Application Manual. Known Error CR 2623

Product MSC / MD Nastran Corrected Version 70

Abstract Documentation - A.M. 2.4 - Generalized Dynamic Reduction

Description

Section 2.4 of the Application Manual documents the algorithm used in the DYCNTR Module to determine the

DYNRED parameters when the auto select feature is used. This documentation

incorrectly states that the solution for the equations in brackets are rounded up to the next integer value when in actuality they are truncated to the next lowest integer value. Furthermore, the documentation does not list two of the criteria used in the algorithm. The first is that the LCSET cannot be greater than the number of non null mass columns and the second is that the LCSET will be adjusted up such that Nr, the number of initial random vectors calculated within the module, will

divide evenly into LCSET.

Avoidance: The differences should be noted in the A.M. Known Error CR 2627

Product MSC / MD Nastran Corrected Version 67.5

Abstract Material Nonlinearity - NLITER - Excessive Wall Clock Time

Description

When running SOL 66 on Version 64 for the IBM VM/CMS, excessive elapsed time

may be encountered. The ratio of elapsed time to CPU time may be as great as 50:1 (IBM VM/CMS V64 and V65C only)

Avoidance: The problem is the result of the overhead involved

with link switching. This error is considered corrected by offering a single link version of the IBM VM/CMS system in Version 67.5. A possible

Known Error CR 2627

avoidance is to try to decrease DMAP looping by selecting appropriate parameters on the NLPARM card. For example, avoid using ITER or LSQN with KSTEP=1. In other words, make the problem converge as fast as possible by minimizing stiffness updates.

Known Error CR 2641

Product MSC / MD Nastran Corrected Version GL

Abstract Material Nonlinearity - NLITER, MPYAD - SFM 3001, SFM 3007, UFM 5423

Description

CLOAD entries must be used to apply load to upstream superelements in SOL

66. If loads are applied upstream and CLOAD entries are not used, SFM 3001 and SFM 3007 will be output from the NLITER module.

Avoidance: Input the required CLOAD Case Control and Bulk Data entries to avoid this error. See Application note dated June 1990 for proper application

of CLOAD input. Known Error CR 2643

Product MSC / MD Nastran Corrected Version 66

Abstract Documentation - RBE3 - SFM 2038

Description

Internally, the [Rm] matrix formed by the RBE3 element is always of the order of six by six. Thus, if less

than six degrees of freedom are specified for the independent degrees of freedom, the [Rm] matrix may be singular

causing the run to fail with SFM 2038 SINGULAR MATRIX FOR ELEMENT being

output.

Avoidance: It is required that six independent degrees of freedom always be specified. An Application Note

on the proper selection of the independent degrees of freedom, published in June of 1985, should be referred to.

SOL 60 should be used to test the numerical stability of MPC's and rigid elements.

Known Error CR 2648

Product MSC / MD Nastran Corrected Version 68

Abstract Documentation - HBT, TRIARG,TRAPRG - Flux Output Coordinate System

In document nastran error list (Page 80-200)

Related documents