The decimal abend (abnormal end) codes described in this chapter occur in ADAInn, ADARUN, and in some utility messages. The message ADAM99 presents both system and nucleus STAE abend codes in hexadecimal; in this case, a nucleus abend code must first be changed to decimal before the description can be located here.
Most abend codes (except 20) result from errors that normally require assistance from your Adabas support technical representative. If abend codes 23 or 24 occur, save the Work data set. For all abend codes, save any dumps and note any messages or other indications that the system issues.
Advise your Adabas technical support representative of the error.
Explanation Module
Code
Workpool too small to execute session autorestart.
(nucleus) 15
DTP=RM: Two-phase commit logic error.
(nucleus) 16
DTP=RM: Work-part-4 overflow.
(nucleus) 17
DTP=RM: Two-phase commit logic error.
(nucleus) 19
Error during system startup (refer to section Nucleus Startup Error Messages in chapter 2).
(nucleus) 20
I/O error during asynchronous buffer flush (Asso/Data/Work/PLOG).
(nucleus) 21
I/O error on sequential PLOG and PLOGRQ=YES/FORCE in effect.
(nucleus) 22
WORK overflow.
(nucleus) 23
Autostart cancelled - protection area inconsistent.
(nucleus) 24
Logical I/O error: Adabas was unable to track one or more I/O operations).
(nucleus) 25
Adabas session cancelled by operator command.
(nucleus) 26
Session ended due to work pool space problems.
(nucleus) 27
Nucleus problem during an asynchronous buffer flush.
(nucleus) 28
Adabas Transaction Manager (ATM) interface error.
(nucleus) 29
Adabas Transaction Manager (ATM) interface error.
(nucleus) 30
Explanation Module
Code
Insufficient workpool space for only active command.
(nucleus) 31
Logic error during file number validation.
(nucleus) 33
Recovery Aid logic error.
ADARAC 33
Abnormal termination with dump.
utilities 34
Abnormal termination without dump.
utilities 35
I/O error occurred while writing to DDDRUCK or DDPRINT. Check JCL.
utilities 36
ET post logic error.
(nucleus) 37
Unexpected response code for internal command.
(nucleus) 38
Fatal internal response code occurred during asynchronous buffer flush.
(nucleus) 39
Getmain failure early during session start.
(nucleus) 40
Fatal error during ADACOM processing (cluster environments).
ADACOM 40
Fatal error during Delta Save Facility processing.
ADADSFN 41
An ADAESI or security violation occurred at startup.
(nucleus) 42
Logic error in command selection (freeze table).
(nucleus) 43
Logic error in an FST write or an online process.
(nucleus) 44
Logic error in asynchronous buffer flush by volume (with ASYTVS=YES) (nucleus)
45
Logic error in the buffer pool manager.
(nucleus) 46
Logic error in thread management (nucleus)
47
Logic error in an ADANCX (cluster environments).
(nucleus) 48
General internal error (various reasons) (nucleus)
49
Logic error in SRB code (Adabas Cluster Services) (nucleus)
50
Logic error in dynamic Work access (nucleus)
51
STCK clock not running (nucleus)
52
Logic error in global hold queue element lock handling (nucleus)
53
Logic error in global file lock handling (nucleus)
54
Fatal error during ADACLU processing (cluster environments).
ADACLU 55
Logic error in ET synchronization process (nucleus)
56
Unexpected error during online recovery (nucleus)
57
Error in protection record bookkeeping (nucleus)
58
Logic error during large object (LB) processing (nucleus)
59
Parallel Services nucleus canceled by peer nucleus (nucleus)
70
An uncorrectable intracluster communication failure occurred.
(nucleus) 79
Logic error in file activity bookkeeping (nucleus)
82
Logic error in extended MU/PE handling (nucleus)
83
Logic error in spanned record handling (nucleus)
84
Logic error in spanned record read-lock handling (nucleus)
85
Explanation Module
Code
Logic error in Adabas Fastpath multifetch processing (nucleus)
86
Logic error in multiple buffers (nucleus)
87
Logic error during global update command synchronization (nucleus)
89
Failure to load and install the trace module ADATRA
Invalid FORCE of active target MPMCMS
226
Wrong ADARER module found MPMBS2
227
STXIT not successfully installed MPMBS2
228
Invalid function MPMBS2
229
Invalid router-40 caller The router-40 call is used to change entries in the ID table in the common memory. The authority of the caller is checked before the MPMBS2
230
change is made. If another Entire Net-work task was started with the FORCE=YES option specified, this task may now be prevented from issuing router-40 calls, and could have been abended.
Caller not correct target MPMBS2
231
Invalid IDT MPMBS2
232
Adabas cancelled in BOURSE WAIT (see the ADAM82 message description in Adabas Messages and Codes).
MPMBS2 233
Enqueue to IDT failed (BS2000) MPMBS2
234
Unable to acquire memory for MPM client table UTAB (BS2000) ADAMP2
235
Unsuccessful STAE MPMMVS
247
Invalid operating system or RMODE; for MPMF4, invalid operating system or RMODE; or CID GETMAIN failed The operating system check did not MPMMVS or MPMF4
248
recognize a "known" operating system. The known system is z/OS. For z/OS:
if the nucleus is running AMODE 31, then RMODE 24 was not set for at least one Adabas module other than ADALNK.
Invalid function MPMMVS
249
Adabas subtask abend. See the ADAM90 message description in the Adabas Messages and Codes.
IORSUB 252
Nonrecoverable abend (caused by STAE/STXIT processing program check or nucleus abend) See the ADAM99 message description in the Adabas Messages and Codes.
MPMIND 253
Invalid function in abnormal termination recovery exit MPMIND
254
Explanation
Return code on 24-call from FREEVIS MPMVSE
257
The subsystem name specified is already being used by another ADABAS SVC. Select another subsystem name and rerun the job.
ADASIP 435
Invalid IDT for option table replace ADASIP
436
No SSCT for option table replace ADASIP
437
Incorrect ADAESI option table ADASIP
438
ADAESI option table load error ADASIP
439
Program loaded above 16-megabyte (RMODE=ANY) IORCMS
440
Incorrect operating system version. Not z/VM.
IORCMS 441
Invalid 40-caller RTRGCS
443
Caller not correct target RTRGCS
Length of user info LT (less than) 0 LNKGCS
453
Error in link initialization routine LNKGCS
454
Incorrect router version LNKGCS
455
User exit before call increased length of user info LNKGCS
456
Internal control blocks not found LDICMS
Invalid length of USER INFO, less than zero or modified by ZAP LNKCMS
460
User exit before-call increased length of USER INFO LNKCMS
461
Line driver error encountered LDICMS
462
IDT manager machine logged off LDICMS
Output tape file protected IORCMS
468
ADASIP CDE cannot be found SIPMVS
469
Explanation
ADASIR non-zero return code SIPMVS
473
SVC table entry changed SIPMVS
ADASIR or ADASVC were not found in the load libraries provided to the ADASIP job
RMODE or AMODE not 24 SIPMVS
Caller specified an unknown or invalid target. This is possibly caused by restarting an already active target using FORCE=YES.
SVCMVS
SVC 12-call without 16-call required SVCMVS
Length of user info less than zero LNKBTO
499
Error in link initialization routine LNKBTO
500
Incorrect router version LNKBTO
501
User exit before-call increased length of user info LNKBTO
Explanation
Not z/OS system; z/OS RMODE is not 24; or z/OS AMODE 31 is not allowed IOROS
Requested file not on tape IORCMS
553
Block count in EOF/EOV label not equal to I/O count IORCMS
554
Tape I/O error during mount or label processing IORCMS
Maximum blocks/track > minimum, I/O error, global sequential BLKSIZE too big, or invalid number (ECBS)
IOROS
Program loaded above 16 meg IOROS
562
Invalid TDCE found during ADAIOR INIT IORBS2
563
Failure to load ADAIOI or AT when trying to enable EVENT NAME IORBS2
564
ECB list overflow IORBS2
565
Invalid SOLSIG return code IORBS2
Fatal error attempting to establish operator command interface (BS2000) ADAIOS
573
ADARUN nucleus extension not found USRCMS
575
Insufficient storage for data area USRCMS
576
User exit before-call increased length of USER INFO LNKCX
577
Explanation
Error in link initialization routine LNKCX
579
Length of USER INFO LT 0 LNKCX
Maximum blocks/track > minimum, I/O error IORCMS
SUBSID error, invalid version, or ADAIOI could not be loaded IORVSE
601
CKTDC error IORVSE
602
Global sequential block size too big or invalid number (ECBS) IORVSE
Length of USER INFO (less than) 0 LNKBS2
608
Incorrect router version LNKBS2
609
User exit before-call increased length of USER INFO LNKBS2
610
WAIT error LNKBS2
611
No IDT (identification table) RERBS2
612
Invalid function RERBS2
613
Explanation Module
Code
Invalid function via caller SVCVSE
614
No IDT (identification table) SVCVSE
Caller specified an unknown or invalid target. This is possibly caused by restarting an already active target using FORCE=YES.
SVCVSE 618
Error attempting to open a VSAM file. See the ADAI68 message description for z/OS in chapter 1.
IORMVS 619
IOR fatal error IORIND
620
PLOG size alteration error. The PLOG size (DUALPLS or PLOGSIZE) was changed with the last startup, and PLOG data is still in the PLOG. Run ADARES PLCOPY to save the data, then restart the nucleus.
IORIND 621
Invalid SAVE area in UB (UEXITB or LUEXIT1) SAVE area (USERSAV) in the Adabas link routine was less than 72 bytes and user exit 1/2 (A/B in Adabas 7) was invoked.
ADAOPTD could not be found, or could not be loaded into storage.
IORVSE 629
Unable to load ADAOPTD.
IORVSE 630
GETVIS failed for sequential file table.
IORVSE 631
No more slots in sequential file table.
IORVSE 632
Internal error file name not found.
IORVSE 633
No TWA is available for the task, or the length of the TWA is less than 24 bytes.
Check the execution of the task with CEDF to determine if the ADDRESS TWA LNCSTUB
636
or ASSIGN TWALENG commands are providing a valid TWA address and length.
A CICS request failed. Use CEDF to determine the failing request and the nature of the failure. Contact Software AG technical support if necessary.
LNCSTUB 637
A CICS request failed. Use CEDF to determine the failing request and the nature of the failure. Contact Software AG technical support if necessary.
LNKOLSC 639
The router (ADARER) detected an Adalink at Adabas 5.2.6 level or higher that issued a call to an Adabas nucleus at Adabas 5.2.5 level or lower while the LNKBS2
640
address of the UB was XS. The Adalink module should be bound below the 16-megabyte limit.
No memory available for LNK anchor block (BS2000) ADALNK
640
The SM6 Adalink detected a router at 5.2.5 level or lower. The ID Table must be initialized with an Adabas nucleus at level 5.2.6 or higher.
LNKBS2 641
The Adalink cannot read the parameter file; the file may be empty, or it may be an ISAM file. Use a SAM/V data set that was created by EDT.
LNKBS2 642
Explanation Module
Code
The Adalink detected a syntax error in its parameters. Correct the syntax and rerun.
LNKBS2 643
The CICS macro level interface is not supported for CICS/ESA 3.2 and above.
ADALNC 645
(BS2000) Cannot read the SYSDTA data set; see the message ADAI56 description.
ADAIOR 646
SVC does not match the IDT (identification table).
SVCMVS 650
ADALNK: unsupported operating system version, unsupported HSI. Adabas version 6.1 and above requires BS2000 version 10 and above and XS31 hardware.
ADALNK 654
Incompatible versions of ADALNK and ADAL2P. Check library assignments;
check TSOSLNK/BINDER protocols. See message ADAK09.
ADALNK 655
The DBID/SVC routing table could not be loaded. This table is required to support Adabas SVC routing by database ID. Ensure that the DBSVCTN ADALINK
657
keyword in the LGBLSET macro (used to prepare the link globals table for the link routine) provides the correct DBID/SVC routing table load module name.
Also verify that the DBID/SVC routing table load module is in a library concatenated in the library search chain so it can be located when the link routine runs.
LNKUES module not available to ADALNK.
ADALNK 658
PC routine invoked by invalid caller.
SVCMVS 659
CICS instructed ATM to perform a single-phase commit, but the outcome of the attempted commit could not be determined. Check the status of the transaction using Adabas Transaction Manager's Online Services.
ATMCXRMI 660
Name/Token service error.
SVCMVS 661
SVC incompatible with install program.
SVCMVS 664
Invalid SVC caller.
SVCMVS 665
Invalid AllocAB deallocation length.
SVCMVS 666
Required CPU instruction set features are not available. IBM ArchLvl 1 instruction set is required.
SVCMVS 667
A syncpoint operation was triggered by an Adabas command, but the user's communication ID was not known.
ATMCXRMI 668
S64 recovery routine manager error.
SVCMVS 669
The CICS EXTRACT command used to obtain the Adabas Task Related User Exit (TRUE) global work area failed. The Adabas 8 or enhanced Adabas 7 CICS environment is not correctly established.
To determine the cause, consult the messages associated with starting the Adabas TRUE issued from ADAENAB (if you are running Adabas 7) or from ADACIC0 (if you are running Adabas 8).
link routines 670
IDT extension not provided. Possible incorrect version of ADASIR is indicated.
SVCMVS 672
Invalid PCRCLU caller.
SVCMVS 673
Explanation Module
Code
A version 8 call using the ACBX has been made, but the link routine did not detect a valid reentrancy token in direct call (field APLXRTOK) of the Adabas 8 parameter list.
link routines 674
The work area passed to an Adabas 8 link routine in the direct call (field APLXRTOK of the APLX) was invalid, or the attempt to obtain storage for the work area failed.
link routines 676
The Adabas 8 link routine could not find the address of a link global table, either because it was not linked with the Adabas 8 link routine, or because an attempt to load the link globals table failed.
link routines 678
Invalid operating system detected - not MVS NETSIP/OS
800
Parameter error detected NETSIP/OS
801
Addressing or residency mode, authorization error or operating system is not a virtual machine guest
NETSIP/OS 802
Error detected during program loading or validation NETSIP/OS
803
Space allocation failure NETSIP/OS
804
NETSIR initialization failed NETSIP/OS
806