Using the CME to Perform Batch Configuration for Newly Deployed eNodeBs

In document Carrier Aggregation(ERAN8.1 06) (Page 117-121)

6.2 Required Information

6.4.5.1 Using the CME to Perform Batch Configuration for Newly Deployed eNodeBs

details about how to set parameters for identifying defective UEs and defining differentiated handling policies, see Terminal Awareness Differentiation.

6.4.4 Hardware Adjustment

BBP installation varies with the BBU type as follows:

l Inter-BBP CA requires an LBBPd or UBBP to be installed in slot 2 or 3 of a BBU3900, if configured, for capacity expansion or upgrades.

l This requirement does not apply to a BBU3910.

When an eNodeB is restarted, all served cells are reactivated and may be randomly distributed on BBPs. It is possible that inter-frequency cells for CA are all re-established on LBBPc boards. In this case, CA does not work between these cells. To prevent this, you are advised to set a fixed mapping between cells and slots. The procedure is as follows:

1. Run the LST EUCELLSECTOREQM command on a macro eNodeB or the LST EUSECTOREQMGROUP command on a LampSite eNodeB to check the existing mapping configuration. If the baseband equipment ID is in the range of 0 to 23 in the command output, the specified cell has been mapped to the specified baseband equipment. If the ID is 255, the cell has not been mapped to any baseband equipment, and then go to the next step.

2. Run the ADD BASEBANDEQM command to add baseband equipment. Ensure that the baseband equipment ID does not collide with any existing baseband equipment ID. 3. Run the MOD EUCELLSECTOREQM command on the macro eNodeB or the MOD

EUSECTOREQMGROUP command on the LampSite eNodeB to map the cell to the new baseband equipment. After that, the cell will be re-established. Then, the mapping takes effect.

6.4.5 Activation

6.4.5.1 Using the CME to Perform Batch Configuration for Newly Deployed

eNodeBs

Enter the values of the parameters listed in Table 6-3 or Table 6-4 in a summary data file, which also contains other data for the new eNodeBs to be deployed. Then, import the summary data file into the Configuration Management Express (CME) for batch configuration.

For detailed instructions, see section "Creating eNodeBs in Batches" in the initial

configuration guide for the eNodeB, which is available in the eNodeB product documentation. The summary data file may be a scenario-specific file provided by the CME or a customized file, depending on the following conditions:

l The managed objects (MOs) in Table 6-3 or Table 6-4 are contained in a scenario- specific summary data file. In this situation, set the parameters in the MOs, and then verify and save the file.

l Some MOs in Table 6-3 or Table 6-4 are not contained in a scenario-specific summary data file. In this situation, customize a summary data file to include the MOs before you can set the parameters.

Table 6-3 Parameters related to CA-group-based CA

MO Sheet in the

Summary Data File

Parameter Group Remarks

CaGroup User-defined sheet CA Group Identity,

CA Group Type Indication

None

CaGroupCell User-defined sheet CA Group Identity, eNodeB Id, Local Cell ID, Preferred PCell Priority, PCell A4 RSRP

Threshold, PCell A4 RSRQ Threshold

None

CaMgtCfg User-defined sheet Local cell ID,

Carrier Aggregation A2 RSRP threshold, Carrier Aggregation A4 RSRP threshold, Carrier Management Switch, CA Active Buffer Length Threshold, CA Deactive Buffer Length Threshold, CA Active Buffer Delay Threshold, CA Deactive Throughput Threshold, Carrier Aggregation A6 Offset, SCell Aging Time, CA A6 Report Amount, CaA6ReportInterval, SCC Disable CQI Threshold, SCC Configuration Interval, Cell Level CA Algorithm Switch

None

CellDlschAlgo User-defined sheet Local cell ID, Downlink CA Schedule Strategy, Ca Scc Doppler Measurement

None

MO Sheet in the Summary Data File

Parameter Group Remarks

InterFreqHoGroup User-defined sheet CoverageBased Interfreq RSRP threshold, A4A5 Based Interfreq A2 RSRP Threshold

None

ENodeBAlgoSwitch User-defined sheet CA Algorithm Switch

None GlobalProcSwitch User-defined sheet Protocol

Compatibility Switch

None

CaGroupSCellCfg User-defined sheet Local Cell ID, SCell eNodeB ID, SCell Local Cell ID, SCell Priority, SCell Blind Configuration Flag, SCell A4 Offset, SCell A2 Offset

None

Table 6-4 Parameters related to frequency-based or adaptive CA

MO Sheet in the

Summary Data File

Parameter Group Remarks

CaMgtCfg User-defined sheet Carrier Aggregation

A2 RSRP threshold, Carrier Aggregation A4 RSRP threshold, Local cell ID, CA Active Buffer Delay Threshold, CA Active Buffer Length Threshold, CA Deactive Throughput Threshold, CA Deactive Buffer Length Threshold, CA A6 Report Amount, CaA6ReportInterval, SCC Disable CQI Threshold, SCC Configuration Interval, Cell Level CA Algorithm Switch

None

CellDlschAlgo User-defined sheet Downlink CA

Schedule Strategy, Ca Scc Doppler Measurement

None

InterFreqHoGroup User-defined sheet CoverageBased Interfreq RSRP threshold, A4A5 Based Interfreq A2 RSRP Threshold

None

ENodeBAlgoSwitch User-defined sheet CA Algorithm Switch,

OverBBUsSwitch

None

GlobalProcSwitch User-defined sheet Protocol Compatibility Switch

None

PccFreqCfg User-defined sheet PCC Downlink

EARFCN, Preferred PCC Priority, PCC A4 RSRP Threshold, PCC A4 RSRQ Threshold None

MO Sheet in the Summary Data File

Parameter Group Remarks

SccFreqCfg User-defined sheet PCC Downlink

EARFCN, SCC Downlink EARFCN, SCC Priority, SCC A2 Offset, SCC A4 Offset None