• No results found

Using the Dynamics Assistant

In document Aspen HYSYS 7.3 Tutorial (Page 140-147)

1.3 Dynamic Simulation

1.3.3 Using the Dynamics Assistant

Before you can run the simulation case in Dynamic mode, the degrees of freedom for the flowsheet must be reduced to zero by setting the pressure-flow specifications. It is also necessary to size the existing valves, vessels, coolers, and heat

exchangers in the Main Flowsheet and the Column Sub-

flowsheet. The following sizing parameters must be specified for these unit operations:

The Dynamics Assistant makes recommendations as to how the flowsheet topology should change and what pressure-flow specifications are required in order to run a case in Dynamic mode. In addition, it automatically sets the sizing parameters of the equipment in the simulation flowsheet. Not all the

suggestions that the Dynamics Assistant offers need to be followed.

The Dynamics Assistant will be used to do the following:

• Add Pressure-Flow specifications to the simulation case. • Size the Valve, Vessel, and Heat Exchanger operations.

Unit Operation Sizing Parameter

Valves Cv value

Vessels Volume

1. Click the Dynamics Assistant icon in the toolbar.

Green checkmarks appear in the Make Changes column beside all recommendations by default. You can choose which recommendations will be executed by the Assistant by activating or deactivating the checkboxes beside each recommendation.

Browse through each tab in the Dynamics Assistant property view to inspect the recommendations.

2. Click the Streams tab.

Figure 1.132

Figure 1.133 Dynamics Assistant icon

The Streams tab contains a list of recommendations regarding the setting or removing of pressure-flow specifications in the flowsheet.

3. For each page in the Streams tab, set the following

recommendations as active or inactive according to the table shown below:

Tab [Page] Recommendation Stream OK Checkbox

Streams

[Pressure Specs] Remove Pressure Specifications Feed 1 Active Set Pressure

Specifications LiquidProdSalesGas ActiveActive Streams [Flow

Specs] Remove Flow Specifications Feed 1Feed 2 InactiveInactive Streams [Insert

Valves] Insert Valves Feed 1Feed 2 InactiveInactive

Ovhd Inactive

Streams [Int.

Flow Spec] Set Internal Flow Specification Reflux Active

Checkbox Description

An active recommendation will be implemented by the Dynamics Assistant.

An inactive recommendation will be ignored by the Dynamics Assistant.

If some of the columns or rows on the pages are not visible, use the scroll bars beside or under the information area to bring the columns or rows into view.

4. Click the Pressure Flow Specs tab.

This tab contains a list of unit operations which can use a Pressure Flow or Pressure Drop (DeltaP) specification. Typically, all unit operations in Dynamic mode should use the Pressure Flow specification.

5. Ensure that all the recommendations in this page are active:

Figure 1.134

Tab [Page] Recommendation Unit Operation OK Checkbox

Pressure Flow Specs

[PF versus DP] Pressure Flow Spec instead of Delta P ChillerGas/Gas ActiveActive

6. Click the Unknown Sizes tab and select the Volumes page.

You can modify any of the default sizing parameters in the Unknown Sizes tab. Once you modify a sizing parameter, the piece of equipment is automatically sized and the volume, Cv, or k-value displayed.

7. For each page in the Unknown Sizes tab, ensure that all the recommendations are active:

Figure 1.135

The Unknown Sizes tab contains a list of the unit operations in the flowsheet that require sizing.

• The Valve operations are sized based on the current flow rate and pressure drop across the valve. The valves are sized with a 50% valve opening.

• The Vessel operation volumes are determined based on the liquid exit volumetric flow rate and a 10- second residence time.

• The Heat Exchanger operations are sized based on the current flow rate and pressure drop across the equipment.

Tab [Page] Recommendation Unit Operation OK Checkbox

Unknown Sizes [Volumes]

Vessel Sizing Chiller Active Gas/Gas (Tube) 1 Active Gas/Gas (Shell) 2 Active

8. Click the Tray sections tab.

The Tray sections tab identifies tray sections and streams whose total steady state pressure drops are inconsistent with the total pressure drop calculated according to the dynamics rating model.

For the purpose of this tutorial, recommendations on this tab will be ignored.

9. Click the Other tab.

10. Activate the following recommendations:

The Other tab contains a list of miscellaneous changes that should to be made in order for the Dynamic simulation case to run effectively.

11. Click the Make Changes button once.

All the active suggestions in the Dynamics Assistant are implemented.

12. Close the Dynamics Assistant property view. Unknown

Sizes [k values]

Heat Exchanger

Sizing ChillerGas/Gas (Tube) ActiveActive

Gas/Gas (Shell) Active

Figure 1.136

Tab [Page] Recommendation Unit Operation OK Checkbox

Other [Misc

Specs] Set Equalize Option Mixers Mixer-101 Active

13. Switch to Dynamic mode by clicking the Dynamic mode icon. When asked “Are you sure you want to switch to dynamics?”, click the Yes button.

Since you deactivated the suggestion to insert a valve on the Ovhd stream, you must set a pressure-flow specification on this stream.

14. In the PFD, double-click the Ovhd stream icon to open stream property view.

15. Click the Dynamics tab, then select the Specs page. 16. Activate the Pressure specification by selecting the

appropriate checkbox.

The Pressure specification should be the only specification active.

Ensure that the Ovhd Molar Flow specification is inactive.

17. Close the Ovhd property view.

18. In the PFD, double-click the Heater icon to access the property view.

You can enter the Ovhd stream pressure specification in either the Main Flowsheet environment or the Column Sub- Flowsheet.

Figure 1.137 Dynamic Mode icon

You can specify the exit temperature of the Heater operation in Dynamic mode. The duty of the heater is back-calculated to make the temperature specification.

19. Click the Dynamics tab, then select the Specs page. 20. In the Model Details group, select the Product Temp Spec

radio button.

21. Close the property view.

22. Save the case as De-Propanizer - Dynamic Model-3.hsc.

1.3.4 Adding Controller

In document Aspen HYSYS 7.3 Tutorial (Page 140-147)