To view the test log when the tests are completed, type the view command in the DSA interactive menu, or select Diagnostic Event Log in the graphical user
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical information, hints, tips, and new device drivers or to submit a request for information.
Message
number Component Test State Description Action
089-801-xxx CPU CPU Stress Test Aborted Internal program
error. 1. Turn off and restart the system. 2. Make sure that the DSA code is at
the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 3. Run the test again.
4. Make sure that the system firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 5. Run the test again.
6. Turn off and restart the system if necessary to recover from a hung state.
7. Run the test again.
8. Replace the following components one at a time, in the order shown, and run this test again to determine whether the problem has been solved:
a. (Trained service technician only) Microprocessor board
b. (Trained service technician only) Microprocessor
9. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
089-802-xxx CPU CPU Stress Test Aborted System resource
availability error. 1. Turn off and restart the system. 2. Make sure that the DSA code is at
the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 3. Run the test again.
4. Make sure that the system firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For the latest level of firmware, go to http://www.ibm.com/support/
docview.wss?uid=psg1 MIGR-4JTS2T and select your system to display a matrix of available firmware. 5. Run the test again.
6. Turn off and restart the system if necessary to recover from a hung state.
7. Run the test again.
8. Make sure that the system firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 9. Run the test again. 089-802-xxx CPU CPU Stress Test Aborted System resource
availability error. 1. Replace the following componentsone at a time, in the order shown, and run this test again to determine whether the problem has been solved:
a. (Trained service technician only) Microprocessor board
b. (Trained service technician only) Microprocessor
2. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
089-901-xxx CPU CPU Stress Test Failed Test failure. 1. Turn off and restart the system if necessary to recover from a hung state.
2. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 3. Run the test again.
4. Make sure that the system firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 5. Run the test again.
6. Turn off and restart the system if necessary to recover from a hung state.
7. Run the test again.
8. Replace the following components one at a time, in the order shown, and run this test again to determine whether the problem has been solved:
a. (Trained service technician only) Microprocessor board
b. (Trained service technician only) Microprocessor
9. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-801-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: the IMM returned an incorrect response length.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-802-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: the test cannot be completed for an unknown reason.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-803-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: the node is busy; try later.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-804-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: invalid command.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-805-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: invalid command for the given LUN.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-806-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: timeout while processing the command.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-807-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: out of space.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-808-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: reservation canceled or invalid reservation ID.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-809-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: request data was truncated.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-810-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: request data length is invalid.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-811-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: request data field length limit is exceeded.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-812-xxx IMM IMM I2C Test Aborted IMM I2C Test stopped a parameter is out of range.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-813-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: cannot return the number of requested data bytes.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-814-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: requested sensor, data, or record is not present.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM Web site for more troubleshooting information at http://www.ibm.com/ systems/support/supportsite.wss/ docdisplay?brandind=5000008 &lndocid=SERV-CALL.
166-815-xxx IMM IMM I2C Test Aborted IMM I2C test stopped: invalid data field in the request.
1. Turn off the system and disconnect it from the power source. You must disconnect the system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to
http://www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 5. Make sure that the IMM firmware is at
the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For more information, see “Updating the firmware” on page 275. 6. Run the test again.
7. If the failure remains, go to the IBM