Diagnosis / Troubleshooting

A. With fault code

Special tool

Commercially available tool

Notice

The blinking code of the retarder pilot light (as of Digiprop-Version 1.0) can be used to obtain a read-out from the fault memory.

Furthermore a diagnosis with the PC „DigiDia“ software is possible. In this case please contact VOITH TURBO or a responsible contracting party.

Multimeter recommended: Fluke 87

53.8224.10

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/8

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Fault memory read-out via retarder pilot light blinking code

Notice

If several faults have been stored in the memory, they are indicated in the sequence of their occurance, but always only one fault per triggering.

Exception:

The fault „Coding fault“ is not held in the memory but is indicated via the blinking code.

The blinking code can be read-out of the control unit with service cable or retarder stage switch.

Fault memory read-out with service cable (Digiprop-Version 0.2)

Requirements

- Retarder stage switch in position 0

- Vehicle in parking position, Ignition ON

1. Service interface L-lead connected to ground for ≥ 2 s. For this purpose, press push-button of service cable switch.

2. First fault as blinking code output.

3. Repeat from step 2 and 3 for more blinking code outputs.

Meaning

- long blinking signals (2 sec.) tens unit.

- short blinking signals (0,5 sec.) single unit.

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/9

R

16016

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Digiprop-Version 1.0

The blinking code can be triggered analogous to V 0.2, the conditions are the same. Additionally the blinking code can be triggered with the help of the retarder stage switch during the service function:

1. Shift RSS-Position 0

2. Shift RSS-Position 1 ( ≥ 2 Seconds) 3. Shift RSS-Position 0

4. Blinking code of first fault is indicated

5. Repeat from step 2 to 3 for more blinking code outputs Addition for versions as of V 1.1

There is a break of 3 seconds before and after each blinking code output, during this time the retarder pilot light is switched off.

Display example for fault code 23:

The number of tens will be indicated first as long ON-time: each 2 seconds The number of singles afterwards will be indicated as short ON-time: each 0,5 seconds

Breaks between each ON-time: each 1 second

If a relevant fault is indicated, the retarder pilot light is ON before triggering of the blinking code, the retarder pilot light switches to permanent lighting again after the blinking code.

If there is only one fault in the memory, the retarder pilot light stays OFF after the output.

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/10

16025

Display example: Fault code 23

E Retarder stage swit ch on A Retarder stage swit ch off

t Time

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Delete fault memory

No marginal conditions in accordance with read-out of fault memory.

1. Ignition: OFF

2. Service interface L-lead connected to ground. For this purpose, press push-button of service cable switch.

3. Ignition: ON

4. Disconnect after ≥ 2 seconds the L-lead of ground.

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/11

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Notice

Meaning of entries in „Measurement/test connection“ column: X 1/15 W X 3/11 Pin 15 to plug X1, Multimeter set for Ohms, Pin 11 to plug X3

Table 1:

1) X 1/15 = ground control unit

2) Only, if no fault is recognizable after a complete check of the periphery: change control unit.

Fault Fault text Fault

class

Trigger time Requirement / Operation

Measurement/

test

connection1 )

Result/

Set point

Cause/

Remedy 2)

Code (Check)

01 Stop light relay/

Short circuit to ground

slight 1 s - Ignition: OFF

- Pull plug X3 out of

or consumers

02 LS 1 output

Short circuit to battery

slight 400 ms - Ignition: OFF - Pull plug X1 out of

control unit - Disconnect plug for extra operation

or consumers

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/12

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 2:

Fault

Fault text Fault class

Trigger time Requirement / Operation

Measurement/

test connection

Result/

slight 1 s - Ignition: OFF

- Pull plug X1 out of control unit

X 1/18 W X 1/

15

With relay installed:

250 - 350 W

Check lead, plugs and relay

or consumers

04 HS 2 output

Short circuit

slight 1 s - Ignition: OFF

- Pull plug X1 out of

or consumers

05 Terminal 15

Undervoltage

serious 60 s - Ignition: OFF - Pull plug X1 out of

control unit - Ignition: ON

X 1/7 V X 1/15 ≥ 17,5 V Check lead, plugs and fuses

06 Terminal 15

Overvoltage

serious 10 s - Ignition: OFF - Pull plug X1 out of

control unit - Ignition: ON - Start engine (idle speed)

X 1/7 V X 1/15 ≤ 32,5 V Checking electrical installation of vehicle (see manufacturer instructions)

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/13

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 3:

* Fault is in serious class, if temperature sensor for oil and water are defective at the same time.

Fault

Fault text Fault class

Trigger time Requirement / Operation Discontinuity / Short circuit to battery 1039 - 1117W 60°C ± 10 °C = 1099 - 1271W 80°C ± 10 °C = 1271 - 1347W Notice:

The measuring in one temperature range

normally is sufficient.

Check lead and sensor

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/14

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 4:

* Fault is in serious class, if temperature sensor for oil and water are defective at the same time.

Fault

Fault text Fault class

Trigger time Requirement / Operation

Oil temperature sensor

Discontinuity / Short circuit to battery 1039 - 1117W 60°C ± 10 °C = 1099 - 1271W 80°C ± 10 °C = 1271 - 1347W Notice:

The measuring in one temperature range

normally is sufficient.

Check lead and sensor

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/15

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 5:

Fault

Fault text Fault class

Trigger time Requirement / Operation

Measurement/

test connection

Result/

Set point

Cause/

Remedy Code (Check)

13 1 Retarder stage

switch Undefined switch state

serious 100 ms - Ignition: ON - Retarder stage switch:

Position 0

X 1/10 V X 1/15

Check lead, plug and retarder stage switch

13 2 - Ignition: ON

- Retarder stage switch:

Check lead, plug and retarder stage switch

13 3 - Ignition: ON

- Retarder stage switch:

Check lead, plug and retarder stage switch

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/16

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 6:

Fault

Fault text Fault class

Trigger time Requirement / Operation

Measurement/

test connection

Result/

- Retarder stage switch:

Position 3

X 1/10 V X 1/15

Check lead, plug and retarder stage switch

13 5 - Ignition: ON

- Retarder stage switch:

Check lead, plug and retarder stage switch

13 6 - Ignition: ON

- Retarder stage switch:

Position 5

X 1/10 V X 1/15

Check lead, plug and retarder stage switch

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/17

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 7:

Fault

Fault text Fault class

Trigger time Requirement / Operation

Measurement/

test connection

Result/

Set point

Cause/

Remedy Code (Check)

14 Retarder stage

switch

Short circuit to battery

serious 10 s - Ignition: OFF - Pull plug X1 out of

control unit - Ignition: ON - Retarder stage switch:

Position 0

X 1/10 V X 1/15 0 V Check lead and plug

15 Retarder stage

switch

Short circuit to battery

serious 1 s - Ignition: OFF

- Pull plug X1 out of control unit - Retarder stage switch:

Position 5

X 1/10 W X 1/15 Resistor infinite

Single check of stages for short circuit

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/18

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 8:

Fault

Fault text Fault class

Trigger time Requirement / Operation

16 Speedometer

signal Discontinuity

serious 2 s - Ignition: ON X 3/2 V X 1/15 ≤==1 V Check lead and speedometer

18 Speedometer

si-gnal

Short circuit to battery

serious 2 s - Ignition: OFF

- Pull plug X3 out of control unit - Ignition: ON

X 3/2 V X 1/15 ≤==9 V Check lead and speedometer

19 ABS

Short circuit to ground

serious 60 s - Ignition: ON X 3/3 V X 1/15 ≥ 3,5 V Check lead, relay and ABS-con-trol unit

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/19

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 9:

Fault

Fault text Fault

class

Trigger time Requirement / Operation

Measurement/

test connec-tion

Result/

Set point

Cause/

Remedy

Code (Check)

21 ABS-Signal undefined serious 60 s - Ignition: ON X 3/3 V X 1/15 ≥ 16,5 V Check lead,

relay and ABS-control unit

22 Internal fault

ABS-current path

serious 1 s - - − Replace control

unit

23 Proportional valve

Fault No. 1:

Short circuit to battery

serious 1 s - Ignition: OFF

- Pull plug X2 out of control unit - Ignition: ON

X 2/3 V X 1/15 ≤==10 V Check lead

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/20

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 10:

Fault

Fault text Fault

class

Trigger time Requirement / Operation

24 1 Proportional valve

Fault No. 2:

- Short circuit proportional valve magnetic

- Short circuit connection lead proportional valve - Discontinuity nal valve magnetic

Valve magnetic - Discontinuity tion lead proportional valve

- Short circuit to ground at proportional valve - Prop.- and shift valve

interchanged

serious 1 s - Ignition: ON

- Pull plug X2 out of control unit

X 2/2 W X 2/3 18-25 W Check lead and proportional valve (valve block) valve (valve block)

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/21

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 11:

Fault

Fault text Fault

class

Trigger time Requirement / Operation valve (valve block)

25 Proportional valve

Fault No. 3:

defective control unit

serious 10 s Replace

control unit

27 Proportional valve

Fault No. 5:

defective control unit

serious 2 s Replace

control unit

28 Terminal 30

Undervoltage

serious 60 s - Ignition: OFF

- Pull plug X1 out of control unit - Ignition: ON

X 1/13 V X 1/15 ≥ 17,5 V Check lead, plug and fuse

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/22

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 12:

Fault

Fault text Fault

class

Trigger time Requirement / Operation

29 Fault control unit serious 180 ms Replace

control unit

31 Control unit:

Coding fault

serious 100 ms Provide new

parameters for control unit

32 Retarder pilot light:

Discontinuity /

Short circuit to ground

serious 3 s - Ignition: OFF

- Pull plug X3 out of control unit - Ignition: ON

X 3/8 V X 1/15 ≥ 17,5 V Check lead, retarder pilot light and fuse

33 Retarder pilot light:

Short circuit to battery

serious 3 s - Ignition: ON

- Retarder stage switch:

Position 1

X 3/8 V X 1/15 ≤==2 V Check lead and retarder pilot light

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/23

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies (Continue)

Table 13:

Fault

Fault text Fault

class

Trigger time Requirement / Operation

Measurement/

test connec-tion

Result/

Set point

Cause/

Remedy

Code (Check)

35 Fault control unit serious 500 ms / 123 s Replace

control unit

37 Fault pedal operation slight 100 ms / 1 s Check

installati-on relating to OEM- respectively VOITH-instructions

Aftersales Service Manual VOITH Retarder 120 Digiprop Page 4.2/24

Diagnosis /

Troubleshooting

cbtd 98-01 53.2659.10

4.2 Troubleshooting and Remedies

(Continue)