Zone configurations and partition selection

DEFAULT ZONE CONFIGURATIONS

Zones can be programmed to be one of thirty different zone configurations (zone types). The default zone configurations are listed below. Programming locations 110-169 can customise all zone configurations.

DATA R conf. DESCRIPTION OF DEFAULT CONFIGURATION

1 1 DAY ZONE

Instant when system is armed; trouble zone when system is disarmed. A day zone will only work if programmed for single end-of-line resistor.

2 2 24 HOUR AUDIBLE

Creates an instant yelping siren alarm regardless of the arming state of the control panel. This zone type is not abortable. This zone can be bypassed.

3 2 ENTRY/EXIT DELAY 1

A trip will start entry delay 1. Absence of a trip during the exit delay will enable the Automatic Bypass or Instant mode, if so programmed.

4 2 FOLLOWER (WITH AUTO- BYPASS DISABLED)

This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not bypass

automatically, even if enabled in segment 1 of location 23. 5 2 INTERIOR FOLLOWER (WITH AUTO- BYPASS ENABLED)

This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will bypass automatically, if enabled in segment 1 of location 23.

6 2 INSTANT

This zone creates an instant alarm whenever it is tripped and the armed LED is on. 7 2 24 HOUR SILENT

Creates an instant silent alarm regardless of the arming state of the control panel. It will not display on the keypad. This zone is not abortable, but can be bypassed.

8 1 FIRE

This zone will light up the fire LED and sound the steady siren each time the zone is shorted. It will also rapidly flash the fire LED, indicating trouble if the zone is open. This zone cannot be bypassed.

9 2 ENTRY/EXIT DELAY 2

A trip will start entry delay 2. Absence of a trip during the exit delay will enable the automatic bypass or instant mode, if so programmed.

10 1 24 HOUR AUDIBLE SUPERVISED

Creates an instant audible alarm, regardless of the arming state of the control panel. It will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This zone is not abortable and cannot be bypassed.

11 2 MOMENTARY KEYSWITCH ZONE

This zone type will arm and disarm the partition or partitions of the control panel where it is resident, every time the zone is shorted. Keyswitch arming will report as user 99. This zone type can only belong to 1 partition.

12 2 INTERIOR FOLLOWER WITH “CROSS ZONE” ENABLED

This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a “Cross Zone” is not being timed, it will start a “Cross Zone” timer. If a “Cross Zone” is being timed, it will create an instant alarm. This zone will bypass automatically, when enabled in segment 1 of location 23.

13 2 INSTANT ENTRY GUARD

This zone creates an instant alarm whenever it is tripped and the stay/instant LED is off. It will start an entry delay time 1 if it is tripped, provided that the system is armed and the stay/instant LED is on.

14 2 ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED

A trip will start entry delay 1. This zone will bypass when the “Group Bypass” command is entered at the keypad. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed.

15 2 INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED

This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the “Group Bypass” command is entered at the keypad. This zone will bypass automatically, if enabled in segment 1 of location 23.

16 2 INSTANT WITH GROUP BYPASS ENABLED

This zone creates an instant alarm whenever it is tripped and the armed LED is on. This zone will bypass when the “Group Bypass” command is entered at the keypad

17 2 MAINTAINED KEYSWITCH

This zone type will arm the partition or partitions of the control panel where it is resident, as long as the zone is shorted. This zone type will disarm the partition or partitions of the control where it is resident, as long as the zone is open. Keyswitch arming will report as user 99. 18 2 ENTRY/EXIT DELAY 1 FORCE ARMABLE

A trip will start entry delay 1. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. This zone is force armable (see feature definitions pages 5-11).

19 2 ENTRY/EXIT DELAY 2 FORCE ARMABLE

A trip will start entry delay 2. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. This zone is force armable (see feature definitions, pages 5-11).

20 2 ENTRY/EXIT DELAY 1 WITH CHIME ENABLED

A trip will start entry delay 1. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone.

21 2 TECHNICAL ALARM, SUPERVISED, AUDIBLE

Any trip on a technical zone creates an audible alarm, regardless of the arming state of the control panel. This zone can be bypassed.

22 2 TECHNICAL ALARM, SUPERVISED, SILENCE

Any trip on a silent technical zone creates a silent alarm, regardless of the arming state of the control panel. Only the transmitter will be activated. This zone can be bypassed. 23 2 INTERIOR INSTANT ZONE

This zone creates an instant alarm whenever it is tripped during the arming state of the control panel. This zone will bypass automatically, if enabled in segment 1 of location 23, or when ths system is armed in the “Stay” mode.

24 2 INSTANT ZONE WITH CHIME ENABLED

A trip will create an alarm when the system is armed. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone.

25 2 FOLLOWER ZONE WITH CHIME ACTIVATED

This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not bypass

automatically, even if enabled in segment 1 of location 23. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone. 26 2 24 HOUR, AUDIBLE, SUPERVISED, LOCAL

Creates an instant audible alarm, regardless of the arming state of the control panel. It will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This zonetype will NOT be reported.

27 2 INSTANT ZONE FORCE ARMABLE

This zone creates an instant alarm whenever the system is armed. This zone is force armable (see feature definitions, pages 5-11).

28 2 INSTANT ZONE ACTIVITY MONITOR ENABLED

This zone creates an instant alarm whenever the system is armed. It will send a report if the zone activity time is reached without a change of state (see location 40, segment 11 and locations 110-169).

29 INSTANT ZONE WITH END OF LINE RESISTOR DEFEAT

This zone creates an instant alarm whenever the system is armed. When the loop is closed, the zone is ready. Opening of the loop means a faulted zone (see locations 110-169). 30 2 24 HOUR, MEDICAL, AUDIBLE, SUPERVISED

Creates an instant audible alarm, regardless of the arming state of the control panel. It will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). A medical report will be sent to the CMS.

Note: all zone configurations are programmed for double end of line resistor

configuration, except for DAY ZONE, FIRE, 24H AUDIBLE SUPERVISED and END OF LINE RESISTOR DEFEAT.

LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data)

Location 25 contains the configuration group (zone type) for zones 1-8. Segment 1 is for zone 1, and segment 8 is for zone 8. You will find the default configurations in the table above.

LOCATION 26 - PARTITION SELECT, ZONES 1-8 (8 segments, feature selection data)

Location 26 is used to select the partition(s) in which zones 1 - 8 reside. A zone may reside in any combination of the 2 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 1, and segment 8 corresponds to zone 8.

Segment 1-8 1 = Partition 1 2 = Partition 2

3-8 Reserved

LOCATION 27 - ZONES 9-16 CONFIGURATION GROUP (8 segments, numerical data)

Location 27 contains the configuration group (zone type) for zones 9 -16. Segment 1 is for zone 9, and segment 8 is for zone 16. You will find the default configurations in the table above.

LOCATION 28 - PARTITION SELECT, ZONES 9-16 (8 segments, feature selection data)

Location 28 is used to select the partition(s) in which zones 9-16 reside. A zone may reside in any combination of the 2 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 28 has 8 segments. Segment 1 corresponds to zone 9 and Segment 8 corresponds to zone 16.

Segment 1-8 1 = Partition 1 2 = Partition 2

3-8 Reserved