• No results found

Digital Super Hybrid System KX-TD208E

N/A
N/A
Protected

Academic year: 2020

Share "Digital Super Hybrid System KX-TD208E"

Copied!
12
0
0

Loading.... (view fulltext now)

Full text

(1)

Digital Super Hybrid System

KX-TD208E

This booklet tells you how to install your KX-TD208 quickly and easily and gives you initial operating instructions.

g

n

i

t

t

e

(2)

C

C o

o n

n t

t e

e n

n t

t s

s

Preparation

Describes the included accessories and required

tools for installation. Page

3

Connection

Shows you how to install your system from set-up to

initial use. Page

4

Basic

Programming

Describes the programs nec-essary depending on your contract and requirements.

Page

6

Programming

Using A Personal

Computer

Shows you a personal comput-er connection and how to

program by using it. Page

9

Basic

Operations

Describes how to make and receive calls in order to confirm the connections.

Page

8

Assistance

Information

Page 11

IBM is a registered trademark of International Business Machines Corporation.

(3)

P

Pr

re

ep

pa

ar

ra

at

ti

io

on

n

¢

¢ Check the package contents. The included materials are:

¢

¢ Necessary user-supplied tools:

✔Phillips screwdriver and flathead screwdriver

✔Electrician’s pliers

✔Telephone company contract

✔Serial printer cable to connect a PC to the telephone system

✔Telephone sockets to connect the telephone equipment, if required

✔Wire (solid wire) for the extension connection: Conductor diameter: Ø 0.4 – 0.6mm Diameter with coating: Ø 0.66 – 1.05mm

DIGITAL SUPER HYBRID SYSTEM

P O W E R

Main Unit ... one

AC Cord ... one

ISDN Line Cord ... one 4-pin Plugs* ... eleven

Screws and Washers ... three Floppy Disk for PC

Programming ... one

Before installing your system

*Do not close the transparent part into the black

(4)

C

C o

o n

n n

n e

e c

c t

t i

i o

o n

n s

s

POWER

DIGITAL SUPER HYBRID SYSTEM

2

. Connect the include

3

. Connect the user -

4

. Connect the PC to

1

. Open the front cove

RS-232C Port (Serial Interface)

To AC Outlet

Reset Switch

Strip the wire cover with pliers.

To the "Extension Jack"

User-supplied Telephone Socket

ISDN Modular Jack

5

. Close the front cove

1.

Extension Jack

4.

Remove the socket cover with flathead screwdriver.

You can program the syste The required operating syste ISDN Port 2

ISDN Port 1

scre Preparation

EXTN.1 AB

PC

socke cover

POWER

DIGITAAL SUPER HYBRIDE SYSTEEM

(5)

ISDN line cord to "ISDN Port 1" and the Telephone socket to the exchange line.

supplied extension line cord to the "Extension Jack" and telephone equipment.

the RS-232C port.

DIGITAL SUPER HYBRID SYSTEM

P O W E R

EXTN. EXTN. EXTN. EXTN. EXTN. EXTN. EXTN. EXTN. 8 7 6 5 4 3 2 1

1. Slide the cover in the direction of the arrow.

2. Tighten the screw.

AC Inlet

Press the transparent part into the black part firmly.

Insert the other end of the wires into the hole on the back and tighten both screws by the driver.

A B 6 5 4 1 2 3

and connect the AC cord to the AC inlet and AC outlet.

3. 2.

5.

Insert the user-supplied telephone wires completely into the holes of the included plugs.

A B 25 DIGITAL SUPER HYBRID SYSTEM

P O W E R

screw

1. Loosen the screw.

2. Slide the cover toward the right while pressing the " " mark.

data using TD208.EXE file in the included floppy disk on the IBM-PC/AT or compatible personal computer (PC). OS) is Version 5.0 or later versions of MS-DOS.

hole

A B To the Exchange Line

¥The maximum length of the extension line cords to the extensions are;

Line Diameter Max. Length SLT PT 0.6mm 0.6mm 240m 620m Note

¥For installing proprietary telephones, an optional PT Interface Card

(KX-TD20870CE) should be installed on your system. Please refer to the Operating Instructions for details.

(6)

B

C

D

B

B a

a s

s i

i c

c

P

P r

r o

o g

g r

r a

a m

m m

m i

i n

n g

g

Some programming is required for basic operation. Check your contract with the telephone company and program as needed. The following flow chart will tell you which programming is required for your system. Please program your system accordingly.

Your contract is:

1: Point-to-Multi-point 2: Point-to-Point

Do you want to specify the receiving extension?

Does your contract apply to a DDI service?

Programming type selection

A

1 2

No Yes No Yes

Connect a tone-type single line telephone to jack number 1 for programming. Check: • Your telephone is on-hook.

• No calls are on hold at your telephone.

Programming

5 1 2 3 4

Password (Default)

Off-hook Dial tone 3

extension no. CLIP/COLP no.

20 digits max. (0···9) [404] CLIP / COLP Number Assignment

21 through 28, 31 through 34, 301 through 308 (ISDN ext.), 300 (all ISDN ext.)

4 0 4 X

(Continued)

X – CLIP / COLP Classfication

1 : CLIP no. Business 2 : CLIP no.-Private 3 : COLP no.-Business 4 : COLP no.-Private

: All

Type

Step 2. Program

[404]

to all the types A, B, C, D.

Step 1. Enter into the programming mode.

Before programming

(1,2, )

ISDN port no.

(7)

B

B a

a s

s i

i c

c

P

P r

r o

o g

g r

r a

a m

m m

m i

i n

n g

g

[407] Multiple Subscriber Number (MSN) Set

(01···10) 16 digits max.(0···9)

MSN location no. (01···10) location no.

[406] ISDN Configuration

6

4 0

[408]–[409] Extension Ringing Assignment —Day / Night for ISDN

(21 ... 28, 31...34) extension no.

0: immediate 1: 1 ring delay 3: 3 rings delay 6: 6 rings delay 9: disable delayed ring time Y - Day...8

Night...9

Consecutive entries

(1,2, )

ISDN port no.

(1,2, )

ISDN port no.

(1,2, )

ISDN port no.

(1,2, )

4 0 7

4 0 Y

A

B

C

D

[412] ISDN DDI Number / Extension Number Transformation

20 digits max. (0···9)

DDI no.

4 1 2

Press Reset Switch.

On-hook

[405] Direct Dialling In

Step 3. Follow the chart according to your programming type .

Step 4. Exit from the programming mode.

1

0 5 2

4

ISDN port no.

(1,2, )

ISDN port no.

extension no.

21 through 28, 31 through 34, 301 through 308, 300, 291 through 298 (UCD Group or Ring Gruop)

Go to Step 4.

C

D

(8)

B

Ba

as

si

ic

c

O

Op

pe

er

ra

at

ti

io

on

ns

s

Let’s try to make and receive a call in order to confirm the connections.

¢

¢ Making a call from extension 21 to extension 22

Did it work???

¢

¢ Calling a Speaking Clock

1. Off-hook.

2. Enter .

3. Dial .

Can you hear the time announcement?

9

Making a call to another extension and receiving it

Making a call to an outside party

At extension 21

1.

Off-hook.

2.

Dial .2 2

At extension 22

1.

Off-hook.

(9)

¢

¢ Refer to the following chart for the pin configuration; HING SYSTEM EXTN. EXTN. EXTN. EXTN. EXTN. EXTN. EXTN. EXTN. 8 7 6 5 4 3 2 1 Connect your personal computer to the RS-232C port with the user-supplied serial printer cable. The Cable must

be shielded and the maximum length

is 2 m.

Connection

Circuit Type (EIA) BB BA CD AB CC CA CB Pin No. 2 3 4 5 6 7 8 Signal Name RXD TXD DTR SG DSR RTS CTS Pin No. 2 3 4 5 6 7 8

Port on your system 9-pin port on a PC

P

(10)

P

Pr

ro

og

gr

ra

am

mm

mi

in

ng

g

U

Us

si

in

ng

g

A

A

P

Pe

er

rs

so

on

na

al

l

C

Co

om

mp

pu

ut

te

er

r

You can program the system data using the application software in the included floppy disk on the IBM-PC/AT or a compatible personal computer. The system pro-gramming data can be stored either on the floppy disk or on your hard disk.

To use the floppy disk for PC programming, you must have MS-DOS (or equivalent) version 5.0 or later. A minimum of 450K of free conventional memory is required.

¢

¢ File Configuration

The file name: TD208.EXE (Execution file) You may store the following files if desired.

Database file: *.DBF ASCII file: *.DBA

Screen save file: P208.PRT

£The “*” represents the file name of your choice. (up to 8 characters)

¢

¢ Setup

1.

Insert the floppy disk into drive A.

2.

Change the current directory to drive A.

3.

Type TD208after confirming the sign “>” and press the Enter key.

– The initial screen appears.

£After the initial screen appears, you can remove the included disk and insert a database file disk to save the data.

£If your monitor is monochrome and you cannot see the cursor easily, exit the

programming mode and re-type TD208/MONO.

£If you need an explanation of the system and its operations, press F4 (Help)

on the initial screen. A Help screen will appear.

£This program is guaranteed to work with MS-DOS only. It is not guaranteed with MS-DOS in Windows.

Programming

!

!

!

(11)

A

As

ss

si

is

st

ta

an

nc

ce

e

I

In

nf

fo

or

rm

ma

at

ti

io

on

n

(12)

References

Related documents

To replace a troubled data disk, please release these 5 screws to remove the cover of the chassis.. You will see there are 2 disk trays in the chassis, one for system disk and one

Such a collegiate cul- ture, like honors cultures everywhere, is best achieved by open and trusting relationships of the students with each other and the instructor, discussions

[r]

You can monitor this measurement to identify remote PCs that require a different swap file setting in the operating system, or more disk space (by installing a second hard disk, for

You can remove and replace the disk drive in a single-disk SG510 appliance, but you must power off the system before replacing the disk drive.. Before

Download a copy of the file to a disk and to a network server, scan the disk with your antivirus software, and then copy the file from the network server to your hard drive after you

The autoassociative neural network model (AANN) is used to capture the distribution of the acoustic and visual feature vectors.. The AANN model captures the distribution of