Huawei SingleDAS Solution Overview

Author : Fengfuan 00179441

Version:V02(20130325)

Multi-Band/Multi-Network/Multi-Vendor/Multi-Operator

In-building Solution

(2)

Content

IBS Requirements In MBB Era

• Huawei SingleDAS Solution

• Cases

(3)

~70% mobile traffic occurred in indoor

~70% mobile traffic occurred in indoor

Source: NTT DoCoMo

Indoor Coverage Transfer from “Nice to Have” to “Must Have”

80% complaints come from indoor

80% complaints come from indoor

 Drop Call  Weak Signal  Poor Call Quality  Low Download Speed

Indoor coverage is vital for business success

Source: Softbank Outdoor 30.30% Indoor 69.70% Customers complaint Voice Services Data Services Outdoor 10% Indoor 90%

(4)

TCO Pressure Drives Operators Sharing DAS

Multi-operator and multi-system sharing is the

effect way to improve the resource utilization

Multi-operator and multi-system sharing is the

effect way to improve the resource utilization

System share is the main trend of large scenes

System share is the main trend of large scenes

Burj Dubai

ET&du share Stadium of Brazil world cup Vivo/OI/TIM/Claro/Nextel

Beijing airport T3 China Unicom& China Telecom

Spain subway

Telefonica/VDF/Orange

Train station of Shenzhen

CMCC/Unicom/Telecom Venice hotel of Macao5 operators sharing

In order to reduce the investment, many operator choose DAS share in large scenes

Some scenarios don’t have enough installation space, operators much share the DAS system

Subway/tunnel Airport

Europe, the site rental cost is 57.99% of TCO

OPEX 73% CAPEX 27% Site rental 57.99% Power consumption 12% Maintenance 2% BSC software upgrade 0.6% Transmission 0.01% BTS Equipment 23% I&C 2.3% De-installation 0.3% Fiber 0.6% Transportation 0.2% BSC 1%

(5)

Content

IBS Requirements In MBB Era

•Huawei SingleDAS Solution

(6)

SingleDAS: New Generation IBS Solution for Multi-Band/Network/Vendor/Operator

UMTS NodeB LTE eNodeB Operator A Slave DCU1 GSM BTS UMTS NodeB LTE eNodeB Operator B Master DCU GSM BTS UMTS NodeB LTE eNodeB Operator C Slave DCU2 GSM BTS DRH DRH Camouflage Camouflage Stadium Subway/Tunnel Skyscraper Airport • Full-digital, full-band,

multi-operator/ system/vendor

No dedicated equipment rooms to reduce CAPEX

Unified RAN & DAS management to reduce OPEX

The Optimal IBS Sharing Solution

M2000

IP network

Optical fiber

(7)

Huawei SingleDAS Portfolio



DCU+DRH

 DCU: Distributed ControlUnit,

Master Unit

 DRH: Distributed Remote Head , Remote Unit



POI(Point Of Interface)

 High performance multi-network sharing unit

SingleDAS

Platform TX RX Operator A Operator B GSM UMTS LTE GSM UMTS LTE Tunnel Leaked cable DRH DRH Optical fiber POI DCU RF Signal RFU/RRU Antenna Coupler Equipment room

(8)

SingleDAS Highlights

• Smooth expansion new band • Software for cell splitting • 2T2R for MIMO

• Smooth re-farming

Smooth Expansion & Evolution

Excellent Performance

• Advance platform

• Low power consumption • Low noise floor

• High reliability

Flexible Deployment

• Different site sharing • Electronic-adjustable POI

• Easy installation & maintenance

Unified Management

• Unified RAN and DAS O&M • Remote interference precise

(9)

DBS3900 IBS: Advanced Digital Platform Ensure Product High Performance

Frequency band: DD800/900/1800/2100/2600MHz(Now)

700/850/1900/AWS(Planning)

Supports 6 bands/sectors

Electronic-adjustable POI: Each RFC supports 4 operators and

input power remote configuration

DCU 1:3 star networking

Support 72DRHs Master DCU

DPC

12 digital port to DRHs or Slave DCU

RFC:

RF interface to BTS (6~+16dBm)

DCU Specification

DCU Specification

RFC : Radio Frequency Card

DPC : Digital Processing Card

DRH Specification

DRH Specification

Dual band

Single-band Triple band

……

Up to

six band

Output power:40W /20W

Power Consumption: 660WVs traditional 1600W (Triple band@40W output)

Noise Figure:3 dB Vs traditional 5dB

MTBF>100,000h >> Vs traditional 50000h

2T2R for LTE MIMO

Natural cooling

Slave DCU1 Slave DCU2 Slave DCU3

1 2 6

cascade to 6 DRH

Excellent Performance Flexible deployment Smooth expansion & evolution Unified management

DC-48V power supply

Power Supply

Power Module

(10)

POI3401: Full-band/High Performance Sharing Unit

Modularized Design, Easy Evolution

Modularized Design, Easy Evolution

Frequency: 800/900/1800/2100/2600MHz

Full bandwidth :

30M@800MHz/ 35M@900MHz/

75M@1800MHz/60M@2100MHz/ 70M@2600Mhz

High performance ensure network quality:

PIM>-160dBc, Isolation(inter-band)>30dB,

Isolation(out-band)>80dB

Each band support

4 operators sharing

(11)

Green Site Saves Power Consumption by 54%

Power consumption save by 54%

1600W

660W

Reduce

54%

Power consumption

Traditional Repeater DBS3900 IBS (Triple band @40W)

Test@10dB PAR

Traditional FFPA DPD+Doherty

DPD+A DHT

12%

25%

30%

DAS3401 Advanced linearity technology ensure PA high efficiency

DAS3401: Dielectric duplexer

Traditional repeater: Metal duplexer

New duplexer with less insertion loss

Traditional repeater:Multi-chip DAS3401: Single chip

High integrated design with low power consumption

(12)

Multi DRHs Uplink Noise Floor Is Not Superimposed to Ensure Network Quality

Excellent Performance Flexible deployment Smooth expansion & evolution Unified management

Carrier 1 RU1

Carrier 1

……

RU2

Carrier 1 RU6

Slot 0 Slot 4 Slot 7

Uplink noise floor

Uplink noise floor

Uplink noise floor

Slot 0 Slot 4 Slot 7

Noise floor superposition

Total uplink noise floor

Traditional Solution

DBS3900 IBS Solution

Carrier 1 DRH1

Carrier 1

……

DRH2

Carrier 1 DRH6

Slot 0 Slot 4 Slot 7

Uplink noise floor

Uplink noise floor

Uplink noise floor

Slot 0 Slot 4 Slot 7

Nonoise floor superposition

Total uplink noise floor

Signal pre-demodulation, close the no user slot channel to ensure nonoise floor superposition

(13)

High Reliability Ensure Network High Performance

Salt spray test

ROHS test

High/low temperature test Rain test Vibration test

Packaging drop test

PIM test Power capacity test

MTBF

High Performance

Network

Sharing the high quality

DNA of Huawei RRU

Strict quality control

processes

Full series of simulation

environment test

Incoming control QC

100% initial test

Inventory sampling test 100% retest

(14)

Different Site Sharing Minimize CAPEX

Busy carrier Idle carrier No dedicated site reduce the high rental cost of new site

DRH BTS BTS BTS site B site A site C Slave DCU1 Slave DCU2 Master DCU Reuse outdoor macro site

Excellent Performance Flexible deployment Smooth expansion & evolution Unified management

New site BTS B BTS C BTS A MU RU MU

High CAPEX for new site

Long construction period

Traditional Solution

(15)

Electronic-adjustable POI Make Installation & Configuration Easier

RFC

embedded electronic-adjustable POI:

 No need external combiner & attenuator

 Input power remote configuration by M2000, no need to work on site

Combiner RU RU RU RUInstallation is difficult

On-site configure input power with spectrum analyzer

Traditional Solution

DBS3900 IBS Solution

RF cable DRH DRH DRH DRH DCU M2000 Coupler Operator A Operator B Operator C Operator D RFU/RRU Load/POI Coupler Operator A Operator B Operator C Operator D Load/POI Attenuator MU RFU/RRU

Configuration

complexity

Excellent Performance Flexible deployment Smooth expansion & evolution Unified management

(16)

Modularized Open Architecture Easy Installation & Maintenance

Fast Installation

Easy Maintenance

900 2100 2100

5

minutes for triple band DRH installation 900900

Each band can be installed one by one

Separated OM for each band

(17)

Software Cell Splitting for Capacity Expansion

U2100 Sector1 F2 G900 TRx1 F1 MU RU RU RU RU U2100 Sector2 F2 G900 TRx1 F1 U2100 Sector1 F2 DRH DRH DRH DRHAdd a new MU

Optical fiber redeployment for cell assignment

Add a new RFC

•Cell assignment by M2000

Footprint is limited

High CAPEX for new MU

Traditional Solution

DBS3900 IBS Solution

MU1

Reduce equipment & engineering investment

U2100 Sector2

F2

New RFC

DCU

(18)

DCU DRH GSM900 LTE1800 RFC DRH DRH DRH DRH

Base station Base station

900Mhz 1800Mhz

Modularized Open Architecture Easy Expansion New Band

Step 1:Insert a new RFC & new cell

in DCU .

Step 2: Add a new DRH

Step 3:Software configuration by M2000

Expansion new band don’t need to replace the equipment

RFC 900

RFC 1800

(19)

2T2R for MIMO Reduce 50% Quantity of Equipments & Transmission

eNodeB TRX2 TRX1 Optical fiber RF cable TRX2 TRX1 Antenna

DBS3900 IBS Solution

DCU: 1Optical fiber :1DRH :1

Traditional Solution

MU: 2Optical fiber: 2RU: 2 eNodeB TRX2 TRX1 Optical fiber RF cable Antenna MU1 MU2 RU2 RU1 RFC2 RFC1

Excellent Performance Flexible deployment Smooth expansion & evolution Unified management

0 50000 100000 150000 20M 2T2R&1T1R DL THP 2T2R 1T1R

Near point Middle point Far point

(20)

Smooth Evolution for Re-farming Without Hardware Expansion

Assume scenario :GSM1800 re-farming to LTE

Step1:Add LTE source

Step2: Customized output power of different system via M2000

Satisfy diversified coverage requirement for multi-system without hardware expansion

1800MHz LTE OR 1800MHz GSM LTE 1800MHz GSM

(21)

One OSS Saves Hardware Investment

DAS REMS

One OSS

:

One OSS server

saves 50% hardware with less

footprint and power

consumption

“2”







 “ 1”

Separate Network

Two OSS

Traditional Solution

SingleDAS Solution

DRH M2000 DRH DRH DRH DRH DRH DCU Co-OM Link HW BTS/ DBS RAN BTS/ DBS RU RU RU MU RAN OSS RAN DAS DAS RAN RAN

(22)

Unified Management Improves O&M Efficiency

Domain Alarm Name NE Relative BTS RAN Output low power RRU1 /

DAS Output low power DRH1 RRU1

Unified Management By M2000

Unified Management By M2000



One

surveillance view(alarm/device

panel ……),

improves O&M efficiency



One

maintenance experience &

One

configuration,

reduce maintenance skill

requirement

M2000

DAS RAN

(23)

Fast Remote Precise Interference Location Saves OPEX

RTWP abnormal BTS MU RU RU RU RU Abnormal RU RTWP abnormal DCU M2000 OM Link BTS DRH DRH DRH DRH DRH Abnormal DRH DRH level RTWP remote detect by M2000

Fast remote troubleshootingLow OPEX

Traditional Solution

DBS3900 IBS Solution

Work on site, low OM efficiencyHigh OPEX for troubleshooting

RTWP d B m -120 -80 -100 1900 1920 1940 1960 1980 Frequency MHz RTWP: -83.5dBm

DRH supports Spectrum scanning

Excellent Performance Flexible deployment Smooth expansion & evolution Unified management

• Found uplink noise interference from DRH

• Found intermodulation interference from passive DAS

(24)

Content

IBS Requirements In MBB Era

• Huawei SingleDAS Solution

(25)

Backgroud

Crystal Hall , the biggest theater in Azerbaijan, Total seats are 25000 . There are many VIP mobile customers.

Azercell mobile market share: 60%, 3G subscriber rate:90%, but have no coverage in Crystal HallHigh complaint rate

SingleDAS Help Azercell Enhance Brand in Crystal Hall

Crystal Hall

Challenge

Equipment footprint is limited ,difficult to deploy E// Marco BTS equipment

1800MHz LTE evolution demand, but it is too hard to get the authorization to rebuild system.

(26)

SingleDAS Help Azercell Enhance Brand in Crystal Hall

Benefit

One set of equipment support multi-system ,fast deployment

High output power(40W per band) make less equipment, easy deployment

One deployment support capacity flexible scheduling and LTE evolution ,reduce CAPEX

Excellent coverage (RSCP>–95dBm : 100%, Ec/Io>–7dB : 99%), reduce subscriber rate RF cable DCU Coupler GSM900 DCS1800 UMTS2100 E// RFU Load Equipment room7 DCU+ 15 tri-band DRH14 sectors access  900MHz:::: 14sector,,4 carrier/sector 1800MHz:::: 14sector,,4 carrier/sector 2100MHz:::: 14sector,,3 carrier/sector

SingleDAS solution

(27)

France

France

France

France SFR: POI3401 Replaced Traditional POI In Paris Subway

SFR: POI3401 Replaced Traditional POI In Paris Subway

SFR: POI3401 Replaced Traditional POI In Paris Subway

SFR: POI3401 Replaced Traditional POI In Paris Subway

Background

SFR deployed UMTS and LTE over all RATP transport network in Paris, and shared with BYG/LotB/Orange. The network is composed of 295

stations and 319 radio sites.

Challenges

5 bands and 4 operators sharing, Inter-modulation

rejection is the biggest challenge

Tradition solution do not support evolution from 2G

to UMTS and LTE

Installation space is narrow, traditional solution is

hard to update new band

(28)

Huawei Value

Low PIM(-160dBc) and high isolation(in-band:

30dB; out-band:80dB) reduced interference,

protect investment

Modularized design, new module is added on

the top to update LTE, no need redundant space

Idler wheel design makes installation easy and

fast, improves efficiency

One system support 5 bands and 4 operators

BTS POI DAS DD800 900 1800 2100 2600

OP1 OP2 OP3 OP1 OP2 OP3 OP4 OP1 OP2 OP3 OP4 OP1 OP2 OP3 OP4 OP1 OP2 OP3 OP4

Idler wheel

Easy for installation DD800

2600

900/ 1800/ 2100

Smooth expansion to LTE

France

France

France

(29)

Summary

1. Huawei innovative SingleDAS fully meet multi-band, multi-network,

multi-vendor ,multi-operator requirements.

2. Advanced digital platform ensure network high performance

3. Flexible deployment for multi-operator IBS sharing, reduce

deployment cost.

4. Easy expansion and smooth evolution, reduce network cost.

5. Unified optimization and management for DAS/RAN, guarantee

(30)

Thank you

www.huawei.com

Copyright©2011 Huawei Technologies Co., Ltd. All Rights Reserved.

The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.

References

Related documents

• No need of third part device management solutions for deployment of Comdasys Mobile Unified Communications Solution. Optimized integration of Unified Communications

BIG-IP ® Access Policy Manager ® (APM) is a flexible, high-performance access and security solution that provides unified global access to your applications and network..

Huawei Smart Campus focuses on the campus network and enables unified, refined management of wired and wireless networks and devices. In Huawei's solution, the entire network

Based on the UC system, Huawei eSpace UC solution provides enterprises with cross-regional mobile office and collaboration applications, enhancing decision-making efficiency

QNAP RAID expansion enclosures and flexible volume management provides a flexible, plug-and-use, and economic storage expansion solution for data-hungry businesses. This

The building offers flexible floor plates of up to 7,000 sq ft and benefits from both on-site car parking and a dedicated property management team to ensure the smooth running

Compute Storage Network Management Traditional Security - Policies tied to physical attributes Virtualized Datacenter Flexible Management 10G Unified Network

The meta- analysis determined that, on average, students in online learning conditions (this means both online and hybrid) had slightly higher performance than those students