• Stulz Was Founded In Hamburg (Germany) In 1947 And Has 5 Production Sites And 14 Subsidiaries In 14 Countries.

• We Are Represented By Partners In Over 110 Countries.

• Stulz Is The World's Leading Manufacturer Of Energy-efficient Precision Air-conditioning Systems For Data Centers

• The Market Share World Wide Is Over 20% In Precision Air Conditioner Company For It Applications

(3)

STULZ GmbH

Hamburg, Germany STULZ S.p.A., Valeggio sul Mincio (VR), Italy

STULZ

Air Technology Systems (Shanghai), China STULZ CHSPL (India) P.Ltd., India STULZ

Air Technology Systems, Frederick/MD, USA

(4)

STULZ Global

Company Headquarters and Production Production

(5)
(6)

Leadership In DC Precision Cooling

1990S’ --- Indirect Free Cooling (Over 1000 Reference Worldwide) 2004 --- Initiating EC Fan Application With Steel Wheel

2009 --- Initiating Direct Free Cooling As Standard Product Line 2010 --- Initiating EC Compressor Application

(7)

Efficiency Supply Air Fans, Free Cooling Form Factor/Configuration Room Size and Height

Surrounding Space

Capacity What IT Load to Plan for

Outdoor Ambient Where

Cold Aisle Conditions Temperature and Humidity

Cooling Type Chilled Water, Air-Cooled, Water-Cooled

(8)

STULZ Indoor Cooling

(9)

Perimeter Cooling

To Help You Strike The Right Balance Between Capital Investment, Operating Costs And Energy Efficiency, We Offer Air Conditioners In A Variety Of Sizes And Configurations.

(10)

CyberAir 3

Cooling Systems

A-System GE-System

Indirect Free Cooling

CW-System

G-System ACW-System

GCW-System CW2-System

(11)

DFC

Indirect Free Cooling

DFC Is A Closed Control System And Combines Compressor Cooling And Free Cooling In Four Stages.The System Switches To Energy-saving Mode As Soon As The Outside Temperature Permits.

Save Up To 60% On Costs Annually

• FC – Free Cooling Mode • Efc – Extended Free Cooling • Mixed – Compressor And Free Cooling

(12)

DFC²

Direct Free Cooling

With Direct Free Cooling, Conditioned Ambient Air Is Used To Keep The Data Centre Cool. This Brings Huge Potential Savings. Thanks To Our Intelligent Controller Additional Savings Can Be Reached In Mixed And DX Mode.

(13)

 Available In Air- And Water-cooled Versions In Various Sizes

 Various Mixing And Filtration Boxes

 Modular Design

 Enlarged Heat Exchanger Surface Area

 Outstanding System Scalability

 STULZ Microprocessor Controls And Monitors All Components

(14)

CyberAir 3

CWE/CWU Water Cooled

• Water-chilled Air-conditioning Unit • Separate Fan Unit

• 40 Kw - 240 Kw

• Energy-optimised Heat Exchanger For High Water And Return Air Temperatures

• Reduced Power Consumption • Swiveling Heat Exchanger

(15)

Cybersonic

Humidifying system for data centres

• STULZ Humidifier Cabinet Is An Autonomous-running All-in-one Solution • Up To 42 Kg/H Humidification Capacity

• 90% Energy Saving Compared To Conventional Electrode Steam Humidifier • Up To 29KW Adiabatic Cooling Capacity

• Outstanding Control Characteristics

—Full Humidifier Capacity Is Available Without Delay On Power-up • Reverse Osmosis And Interchangable Cartridges For Ion Exchanger • Distribution By Infinitely Adjustable EC Fan

(16)
(17)

CyberRow

Row Cooling

• Direct Rack Cooling

• Innovative Horizontal Air Conduction • 4 Cooling Systems

• Up To 62.6 Kw Chilled -Water • Up To 37,8 Kw Compressor-cooled

• Up To 37,8 Kw With Indirect Free Cooling • Standalone A/C Unit

(18)

CyberRow

Row Cooling

• In Widths Of 300, 400 And 600mm • Ec Fans, Independently Controlled • Six Temperature Probes

(19)

Airflow Management

AirBooster, AirBooster Pro and Air Modulator

• Electricity Supply: 230 V / 50 Hz /1 Ph; Lower Inrush Current = UPS

• Low Installation Height = From 400 Mm In Raised Floors

• Compatible With Any Server Racks

• Need-based Flap Position (Air Modulator)

• Infinitely Variable Adaptation Of The Fan Speed Up To 2500 M³/H (Air Booster/PRO)

(20)

AirModulator

Air Booster

AirBooster Pro

For Cooling High Density Rack Of Up To 15KW For Efficient Cold Aisle Cooling

(21)
(22)

CyberCool 2

Cybercool Chillers Are Designed To Work Reliably And With The Highest Efficiency, All Year Round, Regardless Of Local Ambient Temperature Conditions. The Chiller Uses Sophisticated,

(23)

CyberCool 2

• Air-cooled

• Cooling Capacity 10 ~ 1.400 Kw • Large Heat Exchanger Areas

• Variable Speed Screw Compressors With Flooded Evaporators

• Integral Free Cooling Option • UPS Backed Controls

• Integrated Quick Start Function (Full Load In Approx. 120 Seconds)

(24)

CyberCool 2

• Condenser Fan Diffusor For Reduced Energy Consumption And Noise Levels

• Fold Out Fans

• Robust Construction

• Central Control Logic For Multiple Units • BMS Compatibility

(25)

Technology

Quality And Perfect Combination Of Air-conditioning Components Is Especially

Important To Us. Components That Are Not Produced By STULZ Meet Our Specified Requirements And Criteria As Well

(26)

Technology

All The Relevant Steps, From The Rough Draft To The Finished Precision Air-conditioning

System, Are Supported By Finely Tuned Development Tools. Development, Prototyping, Testing And Production All Take Place Under One Roof At All STULZ Locations.

We Continually Invest In New Technology And Processes So That We Can Always Offer You The Best Solutions.

(27)

Expert consulting and planning

If you choose STULZ, you get best support

 Our Air-conditioning Experts Provide End-to-end Support For Your Project, From Initial Contact Through Commissioning – And Beyond If Needed

 After-sales Support From Stulz Or Our Trained Partners

 Air-conditioning Solutions From A Single Source, Worldwide

 Witness Testing On Request, With Comprehensive Documentation

(28)

07.10.2013 STULZ - Gestaltungsmuster "Schlichtheit"

29

(29)

07.10.2013 STULZ - Gestaltungsmuster "Schlichtheit" 30

(30)

References

Related documents

Figure 9 shows the sum of the airflow through the tiles with and without the CRAC unit running for different IT heat load conditions and an 80°F return air temperature

If Do Not Beep After Good Decode is selected, the beeper still operates during parameter menu scanning and indicates error conditions. * Beep After Good

of Indian Affairs extreme control over status Indians. For example, the Superintendent had the power to determine who was of “good moral character” and therefore deserve

INDUCTION SYSTEM INDUCTION SYSTEM INDUCTION PROCEDURE INDUCTION PROCEDURE : : WRITTEN TEST WRITTEN TEST INTELLIGENCE TEST/INTERVIEW INTELLIGENCE TEST/INTERVIEW MEDICAL

port 1 and port 3 being the new outputs, and port 2 and port 4 being the new inputs (see Fig. Then port 4 of the coupler would be the input for the previous RNs placed between

On the basis of Knürr and Liebert products, Emerson Network Power provides numerous cooling solu- tions that meet all requirements – from network rooms through to large-scale

Apart from the uniform pricing constraint it considers the unregulated benchmark and symmetric price- regulation according to the welfare maximization scenario with only a

The functionality that is evaluated comprises the loading of an event log in relational and in-memory databases, executing OLAP operations on the process cube, unloading an event