Available Online at www.ijpret.com 1136

INTERNATIONAL JOURNAL OF PURE AND

APPLIED RESEARCH IN ENGINEERING AND

TECHNOLOGY

A PATH FOR HORIZING YOUR INNOVATIVE WORK

OTP BASED LOCKER SYSTEM USING GSM

MR. R. B. NIMBALKAR1, MR. S. B. LAVHATE1, MR. N. D. TORADMAL2

1. P. Dr. V. Vikhe Patil Institute of Engineering & Technology (Polytechnic), Loni, 2. Government Polytechnic, Malvan

Accepted Date: 05/03/2015; Published Date: 01/05/2015

\

Abstract: In this paper we have proposed a model of OTP based locker. Security describes protection of life and property. To protect our valuable belongings we keep them in a Locker. Locker are used everywhere in home, offices, banks, hotels, shops, malls etc. Mostly the lockers are key based or by some security codes or mechanical linkages. There are more chances to make the duplicate keys, break such passwords to open the lockers. In proposed system when we are opening the locker, the controller will first ask to enter the password. When entered password is correct then controller will send the randomly generated six digits OTP & then user will have to enter the OTP. Then & then only locker will open. If at any stage the entered password is wrong the user will get message on registered mobile that “someone has tried to open the locker”. Thus it gives a two way security aspect. The system is designed using 8051 based microcontroller & simulated on Proteus.

Keywords: GSM, OTP, Locker, Security, Microcontroller

. Corresponding Author: MR. R. B. NIMBALKAR

Access Online On:

www.ijpret.com

How to Cite This Article:

R. B. Nimbalkar, IJPRET, 2015; Volume 3 (9): 1136-1141

(2)

Available Online at www.ijpret.com 1137 INTRODUCTION

In life the people gives more importance to the Security. The people keep their important documents, jewelry & other valuables in the bank lockers, but most of the time it is inconvenient to go to the banks. To avoid this lockers are purchased & kept at houses, offices hotels, malls etc. But there are many chances of opening thy lockers. [3]

The proposed model for safe & smart locking system can be used at homes, banks, shops, malls, hotels etc., Here the system is designed using 8051 based microcontroller 89C51. The keypad is interfaced to the controller to enter the password. It is a two way password protected locker. User has to first enter the four digits password. If the password is correct then on users registered mobile user will get the six digits OTP. Then system will ask user to enter the OTP if OTP is matched then locker will open. The system uses dc motor to open & close the lock. When the dc motor rotates forward the locker will open & when the dc motor will rotate reverse the locker will close.

Specifications:-

Supply Voltage :- 5V Battery

Input to System :- Password

Number of Motors :- 1 DC Motor

Display :- LCD

GSM Module :- SIM 300

Clock Mode :- 24 Hour Mode

SMS Billing :- At Low Cost

Security :- Authentication

Password.

II. Block Diagram:-

(3)

Available Online at www.ijpret.com 1138 As it have many advantages over the others. GSM is widely available in our country. Many operators are available in the market & virtually no distance limitations.[1]

GSM networks operate in a number of different carrier frequency ranges (separated into GSM frequency ranges for 2G and UMTS frequency bands for 3G), with most 2G GSM networks operating in the 900 MHz or 1800 MHz bands. Where these bands were already allocated, the 850 MHz and 1900 MHz bands were used instead (for example in Canada and the United States). In rare cases the 400 and 450 MHz frequency bands are assigned in some countries because they were previously used for first-generation systems.

Most 3G networks in Europe operate in the 2100 MHz frequency band. For more information on worldwide GSM frequency usage, see GSM frequency band.[3]

Today’s GSM platform is living, growing and evolving and already offers an expanded and feature-rich ‘family’ of voice and multimedia services, we can also use this for biomedical enhanced developed fields, so we have using the multimedia service for control any kind of device globally via GSM modem which can be controlled by AT commands using the embedded systems.

The heart of the system is microcontroller. The microcontroller is interfaced with the GSM model SIM 300 through the level shifter MAX 232.

(4)

Available Online at www.ijpret.com 1139 Figure 1. Block diagram

The matrix keypad is interfaced with the microcontroller to enter the password. LCD display will display the messages like Enter the password, Entered password is wrong. The ULN 2003 driver is used to drive the DC motor. When both the entered passwords are matched the controller will give command to the motor to rotate. The clockwise rotations of motor will open the locker & anticlockwise rotations of motor will close the locker. The locker will open for two minutes only. After two minutes the locker will close automatically. [2][4][5]

IV. Circuit Diagram:-

The circuit diagram of the proposed system is as follows.

Figure 2 Circuit Diagram.

(5)

Available Online at www.ijpret.com 1140 V. Flow Chart:-

Figure 3 Flow chart

Figure 4 Flow Chart for Vibration

(6)

Available Online at www.ijpret.com 1141 the mobile number which is stored in microcontroller. It waits again for the SW1 to be pressed. When we press the switch it request for one time password (OTP).

If the OTP is correct then and then only the door is open. Then after we press the switch SW2 the door gets closed. If we enter wrong password the microcontroller gives us three chances, then the microcontroller send message to the mobile number stored in microcontroller that ‘Someone has Entered Wrong Password’.

VI. CONCLUSION:-

The proposed model represents an inexpensive OTP based locker system. A number of literatures related to the topic of control systems and automation were reviewed and analyzed. According to the proposed model, the system is very useful & robust as GSM is used no chances of OTP duplication, hence more reliable. And if anybody attacks on the locker the vibration sensor will sense the vibrations controller will inform to the user.

VII. ACKNOWLEDGEMENT

We would like to take this opportunity to express our gratitude towards our chairman, Padmabhushan Shri Balasaheb Vikhe Patil (Ex. Minister, Heavy Industries, Government of India), Our trustee Hon’ble Dr. Ashok Vikhe Patil CEO, Pravara Rural Education Society Loni, Tal-. Rahata, DistTal-. - Ahmednagar, (MTal-.STal-.) , ProfTal-. NTal-. GTal-. Nikam Principal, PTal-. DrTal-. Vitthalrao Vikhe Patil Polytechnic, Loni for their guidance, advise and providing facilities for our research.

VIII. REFERENCES

1. Vijay Garg, GSM Application, Pearson Edition, 2001-2002, TMH.

2. Rajkamal, Embedded System Design, TMH.

3. Gyanendra K Verma, Pawan Tripathi, “A Digital Security System with Door Lock System Using

RFID Technology”, International Journal of Computer Applications (IJCA) (0975 – 8887), Volume 5– No.11, August 2010

4. The 8051 Microcontroller – Third Edition authored by Kenneth Ayala

5. The 8051 Microcontroller and Embedded Systems – Second Edition authored by Muhammad

Figure

Figure 1. Block diagram
Figure 3 Flow chart

References

Related documents

As any non-Gaussian contribution present in the primordial fluctuations gets imprinted onto the CMB radiation, the search for non-Gaussianity in CMB data becomes an important test

The experimental investigation concluded that carbon black obtained from waste tyres pyrolysis plant could be used as potential sorbent, for the removal of Ni (II) from

RESEARCH ARTICLE Open Access No association between polymorphisms/ haplotypes of the vascular endothelial growth factor gene and preeclampsia Idalia Garza Veloz1,4, Claudia Castruita De

CASE REPORT Open Access Capacity building permitting comprehensive monitoring of a severe case of Lassa hemorrhagic fever in Sierra Leone with a positive outcome Case Report Jessica

Earth Planets Space, 64, 345?351, 2012 Equatorial sporadic E layer abnormal density enhancement during the recovery phase of the December 2006 magnetic storm A case study L C A Resende

Depending on the nature of loading vis-à-vis the characteristics of the media, different formulations; fully-dynamic (FD), partially-dynamic (PD), quasi-static (QS)

This thesis is concerned with the implementation of an effective numerical method to solve the laser ablation problem modeled by fluid dynamic equations and, thereafter, numerically

The association we find is due to an exces- Figure 5.—Linkage disequilibrium between microsatellite sive number of lightly pigmented individuals (pheno- runs in the N-terminal region