1 ON: Denotes the apparatus is turned on
OFF: Denotes the apparatus is turned off.
CAUTION: Describes precautions that should be observed to prevent danger of the apparatus.
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
Protective grounding terminal
WARNING: Describes precautions that should be observed to prevent the danger of injury or death to the operator.
¡ã
¡ã
The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even under the normal operating conditions, which may be sufficient to constitute the risk of electric shock or death.
The symbol is used in the service documentation to in- dicate that specific component shall be replaced only by the component specified in that documentation for safety reasons.
Alternating current/voltage Hazardous live terminal
Read these instructions.
Keep these instructions.
Heed all warning.
Follow all instructions.
Water & Moisture
The apparatus should be protected from moisture and rain, can not used near water, for example: near bathtub, kitchen sink or a swimming pool, etc.
Heat
The apparatus should be located away from the heat source such as radiators, stoves or other appliances that produce heat.
IMPORTANT SAFETY SYMBOLS
IMPORTANT SAFETY INSTRUCTIONS
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION:
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE ON
RIGHT 4
LEFT 4 OUTPUT
LEFT SPEAKER RIGHT SPEAKER
MAINS INPUT 115/230V 60/50Hz Pwr: 250VA T 5A H 110-120V FUSE T 2.5A H 220-240V
Cleaning
Clean only with a dry cloth. Do not use any solvents such as benzol or alcohol.
Servicing
Do not implement any servicing other than those means described in the manual.
Refer all servicing to qualified service personnel only.
Only use accessories/attachments or parts recommended by the manufacturer.
Electrical Connection
Improper electrical wiring may invalidate the product warranty.
Power Cord and Plug
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A ground- ing type plug has two blades and a third grounding prong.
The wide blade or the third prong is provided for your safety.
If the provided plug does not fit into your outlet, refer to elec- trician for replacement.
Power Supply
The apparatus should be connected to the power supply only of the type as marked on the apparatus or described in the manual. Failure to do could result in damage to the product and possibly the user. Unplug this apparatus during lightning storms or when unused for long periods of time.
Fuse
To prevent the risk of fire and damaging the unit, please use only of the recommended fuse type as described in the manual.
Before replacing the fuse, make sure the unit turned off and disconnected from the AC outlet.
Ventilation
Do not block areas of ventilation opening. Failure to do could result in fire. Always install accordance with the manufacturer's instructions.
Object and Liquid Entry
Objects do not fall into and liquids are not spilled into the inside of the apparatus for safety.
Application
-15 +15 -15 +15 -15 +15
-15 +15 -15 +15 -15 +15
0 10 0 10 0 10
0 10 0 10 0 10
0 10 0 10 0 10
HIGH
LOW
MON
EFF
LEVEL HIGH
LOW
MON
EFF
LEVEL HIGH
LOW
MON
EFF
LEVEL
CH 1 CH 2 CH 3
MIC IN MIC IN MIC IN
LINE IN LINE IN LINE IN
-15 +15
-15 +15
0 10
0 10
0 10 HIGH
LOW
MON
EFF
LEVEL
CH 4/5
MIC IN
LINE L LINE R
-15 +15
-15 +15
0 10
0 10
0 10 HIGH
LOW
MON
EFF
LEVEL
CH 6/7
MONO STEREO TAPE IN
REC OUT R L
L R
L R
0 10
0 10 0 10
0 10 MON UP POWER
DOWN
MASTER PROGRAM
OUTPUT
L R
EFF
MON INSERT RETURNEFF
LEVEL
0 0
-6 -6
-12 -12
+6 +6
+12 +12
100 200 500 1K 2K 5K 10K
G R A P H I C E Q U A L I Z E R
INSTRUMENTS EFF / MUTE FOOT SWITCH
DIGITAL EFFECT PROCESSOR 0-Hall1 1-Hall2 2-Room1 3-Room2 4-Room3 5-Plate1 6-Plate2 7-Spring
8-DLY 5ms 9-DLY 10ms A-DLY 20ms B-DLY 30ms C-DLY 200ms D-DLY 300ms E-DLY 400ms F-DLY 500ms
..
Condenser Mic bal
Bass/ Guitar
Power Amplifier Monitor Speaker
Effector Recorder
UP BYPASS STORE
DOWNENTERRECALL
ANALOG LEVEL SEARCHDELAYFEED BACK
1 3
2 4
5
06
1 3
2 4
5
06
POWER INPUT OUTPUT CONTROL PANEL
HALL GATE ROOM
DELAY CHORUS FLANGER PITCH SHIFTER DISTORTION
DUAL ENGINE PROCESSOR
. . .
CLIP
L dB R - 5- 10 - 20 - 30
ON EDITSTORE RECALL + +
F M 3 1 0 6 75
RDSSEEK
1 2RPT3I S4D S5RND6
D - D +
PTYAF CD TUNER BAND
LOCMON
T AP S CLK
CD
23
Introduction
Congratulations on your purchase Powered Mixing console.
manual carefully it in a safe place for f- uture reference.
Main Features
1. CH MIC, Lo-Z input (XLR-Bal), Hi-Z input(1/ 4"Bal phone jack)
2. CH Stereo, 2-Track input channel.
It may be used for Guitar, key-board, CD and Tape recorder signal input.
3. Each channel: 2 Band EQ, Monitor, Effect and signal control.
4. Feed back display Equalizer.
5. Stereo, AUX input channel.
6. 62GD built-in set Digital sound effect processing system (DSP). 62GE built-in Electronic Reverb.
7. 50W/4 + 50W/4 power amplifier.
8. High reliable protection circuit.
Mixer Specifications 1. Rated output power: 10
Pl-
ease read this and keep
0W/4 + 100W/4 2. T. H. D: 0.08% (1KHz 20W)
3. Frequency Response: 20Hz-20KHz, 0.5dB 4. Input level ref: 0dB=0.775V 1mW 600 MIC CH (Lo - Z bal) -58dB
MIC CH (Hi -Z bal) -26dB AUX IN TAPE IN -22dB
5. Surplus Noise: -45dB 6. Equalizer
MIC CH: HIGH-10KHz 15dB, LOW-100Hz 15dB LINE CH: HIGH-10KHz 15dB, LOW-100Hz 15dB Graphic Equalizer:
(100Hz, 200Hz, 500Hz, 1KHz, 2KHz, 5KHz, 10KHz) 12dB MAX, with feed back display 7-band graphic equalizer.
7. Effect:
3201
8. Power Supply: AC 110-120V/60Hz 220-240/50Hz Power Consumption: 150W
9. Volume: 420mm x 275mm x 300mm 10. Weight: 6Kg
REAR PANEL
26. POWER SWITCH
27. POWER SOCKET (with fuse) 28. OUTPUTS 1 / 4" phone jack.
6
0-Hall1 1-Hall2 2-Room1 3-Room2
4-Room3 5-Plate1 6-Plate2 7-plate3 8-Chorus
9-flange A-delay1 B-delay2
C-Chorus/Room1 D-chorus/Room2 E-vocal cancel F-rotary speaker
RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION:
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
ON
RIGHT 4
LEFT 4 OUTPUT
11
26
1127 1128
MAINS INPUT 115/230V 60/50Hz Pwr: 250VA T 5A H 110-120V FUSE T 2.5A H 220-240V
SYSTEM BLOCK DIAGRAM
23
1 SPEAKER EFF SEND LOWPASS FILTERDSP MODULE FOOT SWITCH
EFF RETURN
L REC R
LEFT RIGHT
7 BAND FEED BACKDISPLAY
HEAD PHONE Y/R L CHPOWER AMP(PROTECTOR) MONITOR MONITOR OUTPUT
EQUALIZER R CHPOWER AMP(PROTECTOR)
LO-Z
MIC INPUT CH 1-6 HI-Z
PA N
LEFT&MONOIN STEREO INPUT RIGHT IN STEREO AUX INPUT
L PLAYR POWER SUPPLY
TO POWER AMP TO MIXING
AC230V 50Hz
EQUALIZER AMP SENDLINE OUT
5 DOT DISPLAYLED 5 DOT DISPLA\YLED
HEAD PHONE OUTPUT
RETURN MAIN IN RETURN MAIN IN L OUTPUT SPEAKER R OUTPUT
SENDLINE OUT PAD
LOWHIGH LEVEL
PAN EFF
MONITOR
L R EF F
MO NIT
OR +V
-V
GN D
EQUALIZER LOWHIGH LOWHIGH TYPE & AUX
AMP EQUALIZER AMP
LE VE
L L VE LE
EF FE CT
MIC CHANNEL INPUT 1. HIGH (EQ)
2.LOW (EQ)
3. MONITOR VOLUME CONTROL 4. EFF LEVEL
5. LEVEL Channel level 6. Lo-Z XLR connector(Bal)
STEREO CHANNEL INPUT 7. HIGH
8. LOW (EQ) (EQ)
9. MONITOR VOLUME CON- TROL
10. EFF LEVEL
11. LEVEL Channel Level 12. LEFT& MONO 1 / 4" ph- one jack.
13. RIGHT 1 / 4" phone jack.
14. Lo-Z XLR Connector(Bal) 15. TAPE IN/REC OUT L/R RCA connector
16. Mono and Stereo selector
FRONT PANEL
-15 +15
-15 +15
0 10
0 10
0 10 HIGH
LOW
MON
EFF
LEVEL
CH 3
MIC IN LINE IN
-15 +15
-15 +15
0 10
0 10
0 10 HIGH
LOW
MON
EFF
LEVEL
CH 4/5
MIC IN
LINE L LINE R
1
2
3
4
5
6
118
9
10
11
13
14 117
12
15 16
MONO STEREO TAPE IN
REC OUT L R
L R
19. Program selector lab l
20. MASTER LEVEL: Left, Right, Monitor.
21. AUX IN (Stereo) 1 / 4 phone jack.
22. EFF OUT Return 1 /4 phone . 23. MONITOR OUT 1 / 4 phone . 24. LINE OUT Send 1 / 4 phone . 25. FOOT SWITCH
(16 band) e
"
" jack
" jack
" jack 1 / 4" phone jack.
18. Eff Return Level control 17. 7 Band EQ
L R
0 10
0 10 0 10
0 10 MON UP POWER
DOWN
MASTER PROGRAM
OUTPUT
L R
EFF
MON INSERT
RETURNEFF
LEVEL
0 0
-6 -6
-12 -12
+6 +6
+12 +12
100 200 500 1K 2K 5K 10K
G R A P H I C E Q U A L I Z E R
INSTRUMENTS EFF / MUTE
FOOT SWITCH
DIGITAL EFFECT PROCESSOR
..
11171118
11 20
1121 1
122 1
123 1
124
1811 19
1125
0-Hall1 1-Hall2 2-Room1 3-Room2
4-Room3 5-Plate1 6-Plate2 7-Plate3 8-Chorus
9-Flange A-Delay1 B-Delay2
C-Chorus/Room1 D-Chorus/Room2 E-Vocal Cancel F-Rotary Speaker
0-Hall1 1-Hall2 2-Room1 3-Room2 4-Room3 5-Plate1 6-Plate2 7-Plate3
8-Chorus 9-Flange A-Delay1 B-Delay2 C-Chorus/Room1 D-Chorus/Room2 E-Vocal Cancel F-Rotary Speaker