• No results found

PTTeDatabook1

N/A
N/A
Protected

Academic year: 2021

Share "PTTeDatabook1"

Copied!
119
0
0

Loading.... (view fulltext now)

Full text

(1)

PRECISION

TUBE TECHNOLOGY

CT Services & Product Specifications

Technical Support & Welding Guidelines

Research Bulletins & CT Technical Papers

PTT - TechHandbook 1/97

PRECISION

TUBE

TECHNOLOGY

,

INC

.

C

OILED

T

UBING

(2)

PRECISION

TUBE TECHNOLOGY

P R E C I S I O N T U B E T E C H N O L O G Y , I N C .

COILED TUBING

TECHNICAL HANDBOOK

Telephone: (281) 458-2883 FAX: (281) 458-2886

Email: [email protected]

(3)

oiled Tubing Products

C

"Precision Tube Technology ... Leading the way in coiled tubing manufacturing technology."

R ev.003 1/97

PRECISION

TUBE TECHNOLOGY

PRECISION

TUBE TECHNOLOGY

Coiled Tubing Technical Data

Standard Downhole Products

O

VERVIEW

OF

P

RODUCTS

& S

ERVICES

Q

UALITY

A

SSURANCE

S

YSTEM

& C

ERTIFICATION

P

RODUCT

S

PECIFICATIONS

T

ECHNICAL

S

UPPORT

W

ELDING

G

UIDELINES

&

C

OILED

T

UBING

C

ONNECTIONS

S

HIPPING

S

POOL

C

APACITIES

& S

PECIFICATIONS

C

OILED

T

UBING

T

ECHNICAL

P

APERS

&

R

ESEARCH

B

ULLETINS

Overview

Material Certificate &

Weld Location Record

HS-70™ Tubing Data

HS-80™ Tubing Data

HS-90™ Tubing Data

Metric Conversions

SEE WEBSITE for Dynamic Model

Freepoint Calculation

Corrosion Prediction

Coiled Tubing Order QuickList / Checklist

Definitions & Calculations

C

OLLAPSE

/B

URST

& F

RICTION

C

HARTS

Maximum Slack-off Weight

HS-110™ Tubing Data

(4)

Downhole Coiled Tubing Products

Contact Information

Coiled Line Pipe Products

Precision Tube Technology's range of coiled line pipe products, produced in

accordance with API 5LCP, offers an economical alternative to conventional

subsea flowlines and control lines, as well as onshore surface or buried flowlines

for gathering system tie-ins and gas injection. Benefits include:

Coating systems applied at the tube mill with unsurpassed subsea and

surface corrosion protection.

Up to several miles without tube welds.

Elimination of costly weld, heat-treat, x-ray, and inspection steps.

Dramatic reduction of installation time and equipment

Reduced right-of-way costs and environmental impact.

Precision offers a range of downhole products tailored to the specific demands of

an expanding spectrum of downhole coiled tubing applications. From standard

well-workover and velocity/production strings to logging, drilling and special

application strings with factory installed wireline, capillary tubes, or integral tools,

Precision's technical and sales staff will work with the customer to select, design

and build the tubing string best suited to ensure the success of the project. A

sampling of products include R

EEL

-

TAPER

tapered tubing strings and

FRee

-internal flash removed coiled tubing.

P

recision Tube Technology is wholly devoted to the production of the finest

grades of downhole coiled tubing and coiled line pipe in the world.

The company has gathered a dedicated team of mill, quality assurance, service,

and sales personnel committed to product quality and the customer. PTT's mills

incorporate the very best tube making and coating technology available. As the

first U.S. tubing manufacturer certified to the ISO-9001 standard, Precision

ensures the supply of the highest quality coiled tubing products through its Quality

Assurance System, designed for complete traceability of the material,

manufacturing processes, tests and inspections for every string of coiled tubing.

Precision's objective is to make its combined experience work to the customer's

benefit by developing products to suit the rapidly changing needs of the industry.

Products & Services:

Downhole Tube Grades

HS-70

HS-80

HS-90

HS-110

Available as both CM (continuously-milled) W (conventional butt-welded)

Ongoing development of other alloys & tube strengths

Coiled Line Pipe Grades

X-52-C

X-65-C

X-70-C

X-80-C

P

ER

API

5LCP

Other material strength grades available. Available with a variety of external coating systems: (FBE, HDPE, HDPP, 3 layer)

Sizes

O.D. - 1" thru 6-5/8"

*

Walls - .080" thru .300"

(Other sizes available on request.)

* PTT - Peterhead, Scotland. PTT's Houston plant capable of up to 5" O.D.

In-Line Coating Facility

FBE

2 layer extruded HDPE

3 layer FBE/HDPE

3 layer FBE/HDPP

*Pre-applied at the coiled tubing mill for buried, surface and subsea corrosion protection.

Full CT Services

Factory and field welding

services & weld quality

assurance

Comprehensive spooling

services

Hydro-test and N-ert

nitrogen purge

Cable injection/removal

CT inspection & testing

Local technical support

Research & Development

Higher strength & CRA

materials

Advancement of welding

techniques

Enhancement of tube

quality & manufacturing

techniques

Tube life modelling

Coiled Tubing

Products and Services

Precision Tube Technology, Inc.

Precision Tube Technology Ltd.

Physical Address:

8615 Beltway 8 East

South Bay Oil Service Base

Houston, TX 77044

Peterhead, Scotland AB42 2ZD

Mailing Address:

P.O. Box 24746

South Bay Oil Service Base

Houston, TX 77229

Peterhead, Scotland AB42 2ZD

24 Hours/Weekdays

Tel.*

(281) 458-2883

(44-1779) 481-716

Weekends/Holidays Fax.

(281)

458-2886

(44-1779)

481-718

(365 days a year)*:

Email.

[email protected]

[email protected]

Canadian Service:

P r e c i s i o n T u b e C a n a d a L i m i t e d

Center

131- 37565 Highway 2, Red Deer County

Red Deer, ALBERTA T4E1B4 CANADA

Tel. (403) 347-4544 Fax. (403) 347-2102

PRECISION

TUBE TECHNOLOGY

oiled Tubing Products

C

"Precision Tube Technology ... Leading the way in coiled tubing manufacturing technology."

Rev.007 6/99

See us on the web @ www.precisio.com

PRECISION

(5)

Development of

HS 110ª

Continuously-Milled Coiled Tubing

GRADE DESCRIPTION:

This is a new ultra high strength coiled tubing grade which exhibits yields

strengths approximating 108,000 Ð 115,000 psi while maintaining good ductility. The grade exhibits superior

low cycle fatigue life with moderate to high internal pressure levels without a tremendous sacrifice in life

expectancy at low pressure levels. Even with the very high strength levels, this grade exhibits superior

resistance to environmental cracking. (Caution: Even though this ultra high strength grade exhibits increased

resistance to environmental cracking such as sulfide stress corrosion cracking, the resistance is inferior to the

HS-90

coiled tubing grade and the lower strength grades. Care must be taken when selecting high strength

coiled tubing for severe hydrogen sulfide containing environments.)

APPLICATIONS:

The need arises for ultra high strength coiled tubing because of the following

(1) HIGH PRESSURE SERVICE Ð The higher mechanical properties permit higher pressure ratings at equal

wall thicknesses. For example with 2Ó x 0.134Ó coiled tubing, increasing the yield strength from 70,000 psi

to 90,000 psi to 110,000 psi increases the burst pressure based on Von Mises yield criteria from 9270 psi

to 12,390 psi to 15,420 psi respectively.

(2) LONGER REACH - The higher mechanical properties permit greater tubing loads which correlate directly

to greater depths at equal tubing dimensions.

(3) WEIGHT SAVINGS - The higher mechanical properties permit decreasing wall thickness for equal load and

pressure capabilities. For example, a 2Ó x 0.134Ó coiled tubing with a 110,000 yield strength can sustain a

greater internal pressure than a 2Ó x 0.175Ó with an 80,000 psi yield strength.

TARGET PROPERTIES:

The target properties are 110,00 ksi yield strength, 118,000 ksi tensile strength

with an elongation of at least 22%. These values are target values because additional new heats of steel are

necessary to define the statistical ranges and firmly establish production ranges.

Sample Tested Properties

from HS-110ª Milled Tubing

Wall Thickness Yield Strength Tensile Strength Elongation

inches

ksi

ksi

0.190

112.9

119.9

28%

0.175

116.3

124.4

26%

0.175

113.5

122

27%

0.156

114.6

122.4

24%

0.156

113.1

120.7

26%

0.156

112.8

119.4

25%

0.156

115.1

122.2

26%

0.145

116.1

124.2

24%

0.145

112.9

121.2

26%

0.134

113.4

126.6

23%

0.125

113.4

121.5

25%

Hardnesses Associated

with Yield Strength

Yield Strength

Typical Hardness

Range

70 ksi (483 MPa)

85 - 94 Rockwell B

80 ksi (552 MPa)

90 - 98 Rockwell B

90 ksi (621 MPa)

94 HRB - 22 HRC

100 ksi (690 MPa)

20 - 25 Rockwell C

110 ksi (758 MPa)

22 - 28 Rockwell C

Note: All hardness values are rough

estimates. Average tested hardnesses for

HS-110ª range from 22 - 26 HRC

0.125

0.109

110.8

111.3

119

117

25%

23%

(6)

0 5 0 100 150 200 250 Trips (48" Radius) 600 2000 4000 6000 8000 10000

Cycle Pressure (PSI)

1.50" x .134" Coiled Tubing

Fatigue Life

HS-70ª Model HS-80ª Model HS-90ª Model HS-110ª Model HS-110ª Test

Modeling on Cerberus 4.5 Updated

0

50

100

150

200

250

300

350

400

Trips

(72" Radius)

4000

8000

10000

Cycle Pressure (PSI)

1.75" x .190" Coiled Tubing

Fatigue Life

HS-70ª Model

HS-80ª Model

HS-90ª Model

HS-110ª Model

HS-110ª Test

(7)

QUALITY ASSURANCE

SYSTEM & CERTIFICATION

PRECISION

(8)

PRECISION

TUBE TECHNOLOGY

Q

UALITY

A

SSURANCE

S

YSTEM

O

VERVIEW

A word about Precision Tube Technology's Quality Policy...

Precision Tube Technology, Inc. is dedicated to the pursuit of excellence in the products

and services that we provide to our customers. We recognize that the needs of our

customers are the sole reason for our company to exist and that in order to achieve and

consistently maintain the highest level of quality, every member of the company must be

an active participant in the company's Quality Assurance programs and policies.

The Precision Tube Technology Quality Assurance Manual is the company's formal

guide for the methods and requirements necessary to achieve our standard of increasing

excellence and to ensure compliance with all customer, internal, ISO-9001 and statutory

requirements, but in recognition that perfection is a goal and not an achievement, all

employees, vendors, and customers are encouraged to make any suggestions for

improvements to products and services.

A final statement to employees and vendors: this commitment to quality is absolute.

Whenever a question arises that concerns quality, the decision will be in favor of

improved quality.

Following is an overview of the standard quality control steps that are taken in the

manufacturing process for continuously milled coiled tubing:

CHEMICAL ANALYSIS - Representative strip material from each mill heat is submitted

for a chemical composition analysis. An independent laboratory verifies that the

chemical composition meets PTT specification.

RECEIVING INSPECTION - Each strip received is dimensionally checked for width and

gauge, and visually inspected for slitting defects. Additionally, each strip is assigned a

unique identification number which ensures traceability.

RADIOGRAPHY - All strip bias welds are 100% radiographed (X-rayed) using a procedure

exceeding the requirements of ASME Section V, Article 2. Unlike ASME Section VII or

III, PTT's acceptance criteria allows no welding defects or repair of defective areas.

CRUSH AND FLARE - The seam-weld integrity is verified by these two destructive tests

using samples taken at the beginning and the end of each milled string. The Crush test

flattens the tubing fully upon itself with the seam-weld oriented at the apex of the fold;

no open defects are permitted in the weld. The Flare test stretches the open end of the

tubing over a mandrel with a 60

°

taper; the tubing must expand 21% over the initial

diameter before failure (splitting) and the seam weld cannot fail. The Crush and Flare

tests are in accordance with ASTM A450.

QA Statement1 - 2/97

Houston, Texas

(9)

PRECISION

TUBE TECHNOLOGY

Q

UALITY

A

SSURANCE

S

YSTEM

O

VERVIEW

(

CONTINUED

)

ELECTROMAGNETIC TESTING (Eddy Current) - As tubing is milled, the seam weld is

continuously monitored using electromagnetic (eddy current) testing. The eddy

current testing is calibrated at the beginning and the end of each milled string using

standards with 1/32 inch holes drilled through the seam weld. The eddy current test

station is equipped with an audible alarm and with an automatic marking system.

This will identify precisely areas that may require further inspection.(i.e. magnetic

particle testing and radiography)

DIMENSIONAL INSPECTION - The beginning and end of each strip as well as the bias

weld width and thickness is inspected at the assembly line. Samples from the

beginning and the end of each milled string are dimensionally inspected for ovality (

±

0.010 inches), wall thickness (minimum specified for nominal specified) and

seam-weld mismatch (

±

10% of actual wall thickness).

TENSILE TESTING - Full-section tubing samples from the beginning and the end of

each string are tensile tested to verify the Yield Strength (0.2% Offset Method),

Ultimate Tensile Strength, and Percent Elongation (2-inch Gauge Length). Tensile

testing and determination of properties is in accordance with ASTM A370.

MICROHARDNESS TESTING - Portable hardness tests are performed on all strip bias

welds. Cross-sections of tubing samples from the beginning and end of each string are

metallographically prepared for microhardness testing (Knoop Method). Multiple

measurements are made in the seam-weld, associated Heat-Affected-Zone (HAZ) and

unaffected base metal. Hardness in any area cannot exceed 22 HRC.

METALLOGRAPHY - The prepared cross-sections are then metallographically

examined to determine the degree of mismatch at the seam-weld and to examine the

weld and HAZ for proper microstructure and normalizing. Photomicrographs are

then taken of the seam-weld and become part of the QC Test Record.

HYDROSTATIC TESTING - Each string is hydrostatically tested to 90% of the

theoretical yield burst pressure for a minimum of 30 minutes. Test pressure and

duration are recorded on a chart and become part of the permanent record. As the

tubing is filled with water, a steel gauge ball of a specified diameter is run through the

tubing to insure there are no obstructions. After hydro-testing, the test fluid is purged

from the string using nitrogen gas.

QA Statement2 - 2/97

Houston, Texas

(10)
(11)

EXAMPLE CERTIFICATE - FOR SAMPLE USE ONLY

PRECISION

TUBE TECHNOLOGY

Date

Master Coil

Number

QC Test

Number

Yield Strength

(0.2% Offset),

psi

Ultimate

Tensile

Strength, psi

Percent

Elongation

(2 in. Gage)

Base

Weld

Flare Crush

Weld

X-ray

psi

min.

Hardness, HRB

Hydrostatic

Test

ASTM A450

MECHANICAL PROPERTIES

I certify the above tests, inspections and reports are true and accurate. The products of

this certificate were manufactured to the requirements of Precision Tube Technology's

ISO-9001 certified quality program.

(Certificate, Rev. 4) (3/1/96))

REPORT OF TESTS, INSPECTIONS AND ANALYSES

TUBING INFORMATION

Tubing Grade

Diameter, in.

Wall Thickness, in.

Size:

Length, ft.

CUSTOMER INFORMATION

PTT Order No.

Date Completed

Customer

Customer P.O.

Remarks:

Certificate No.

CHEMICAL ANALYSES

,

Wt. %

C

Mn

P

S

Si

Cu

Ni

Cr

Other

Heat Number

String Number

Master Coil No.

(12)

EXAMPLE WELD LOCATION RECORD - FOR SAMPLE USE ONLY

Weld Location Record

STRING NO.:

SIZE:

PTT NO.:

DATE SHIPPED:

SHIPPED TO:

TOTAL LENGTH:

Gauge

Length

Strip No.

Indicates CM™ (Continuously Milled) type weld

Indicates W™ (Butt-Welded) type weld

Prepared By _______

P.O. NUMBER:

GRADE:

PRECISION

TUBE TECHNOLOGY

1502 Segmented Wing Half

(Wood Shipping Spool)

(13)

TUBING DATA

HS-70 CM™

(CONTINUOUSLY MILLED TUBING)

HS-70 W™

(BUTT WELDED TUBE SECTIONS)

PRECISION

(14)

PRECISION

TUBE TECHNOLOGY

M

ATERIAL

S

PECIFICATIONS

- HS-70™

HS-70 CM™

(CONTINUOUSLY MILLED TUBING)

HS-70 W™

(BUTT WELDED TUBE SECTIONS)

PHYSICAL PROPERTIES:

CHEMICAL COMPOSITION - %:

STEEL ALLOY DESCRIPTION:

MINIMUM YIELD STRENGTH - 70,000 PSI

MINIMUM TENSILE STRENGTH - 80,000 PSI

MINIMUM ELONGATION - 30%

MAXIMUM HARDNESS - 22C ROCKWELL

CARBON 0.10 - 0.15 RANGE

MANGANESE 0.60 - 0.90 RANGE

PHOSPHORUS 0.03 MAX

SULFUR 0.005 MAX

SILICON 0.30 - 0.50 RANGE

CHROMIUM 0.45 - 0.70 RANGE

COPPER 0.40 MAX

NICKEL 0.25 MAX

A-606 TYPE 4, MODIFIED

Houston, Texas

Telephone: (281) 458-2883 FAX: (281) 458-2886

(15)

HydroTest

9 0 %

Yield

Minimum

Tensile

Minimum

Internal

Yield Min

Yield

Ultimate

Gallons

Barrels

Gallons

Barrels

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE LOAD BODY

(Lbs.)

INTERNAL

PRESSURE (psi)

TORSIONAL

YIELD

(ft. - lbs.)

INTERNAL

CAPACITY

per 1000 ft.

EXTERNAL

DISPLACEMENT

per 1000 ft.

w/ min.

Wall

TUBING AREA

(sq. in.)

Internal

Min

PRECISION

TUBE TECHNOLOGY

(70 Ksi Min. Yield Strength; 80 Ksi Min. Ult. Strength; 30 % Min. Elongation; Loads calculated using nom. wall)

HS-70™ GRADE* SELECTED COILED TUBING DATA

Tel. 281-458-2883

Fax. 281-458-2886

Email: [email protected]

O . D .

( m m )

Wall

( m m )

0 . 0 8 0 0 . 0 8 7 0 . 0 9 5 0 . 1 0 2 0 . 1 0 9 0.076 0.083 0.090 0.097 0.104 0.840 0.826 0.810 0.796 0.782 0.788 0.850 0.920 0.981 1.040 16,200 17,500 18,900 20,100 21,400 18,500 20,000 21,600 23,000 24,400 10,500 11,400 12,300 13,300 14,200 9,400 10,300 11,100 11,900 12,700 0.221 0.239 0.257 0.275 0.293 0.565 0.546 0.528 0.510 0.493 319 341 362 382 401 344 370 395 420 443 28.79 27.84 26.77 25.85 24.95 0.69 0.66 0.64 0.62 0.59 40.80 40.80 40.80 40.80 40.80 0.97 0.97 0.97 0.97 0.97 1 . 0 0 0 1 . 0 0 0 1 . 0 0 0 1 . 0 0 0 1 . 0 0 0 25.4 25.4 25.4 25.4 25.4 2.03 2.21 2.41 2.59 2.77 0 . 0 8 0 0 . 0 8 7 0 . 0 9 5 0 . 1 0 2 0 . 1 0 9 0 . 1 1 6 0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0.076 0.083 0.090 0.097 0.104 0.111 0.118 0.128 0.138 0.148 0.167 1.090 1.076 1.060 1.046 1.032 1.018 1.000 0.982 0.960 0.938 0.900 1.002 1.083 1.175 1.254 1.332 1.408 1.506 1.601 1.715 1.827 2.014 20,600 22,300 24,100 25,800 27,400 28,900 30,900 32,900 35,200 37,500 41,400 23,500 25,400 27,600 29,400 31,300 33,100 35,300 37,600 40,300 42,900 47,300 8,400 9,200 9,900 10,700 11,400 12,200 12,900 14,000 15,000 16,000 17,900 7,600 8,300 9,000 9,600 10,300 11,000 11,600 12,600 13,500 14,400 16,100 0.280 0.304 0.328 0.351 0.374 0.397 0.420 0.451 0.482 0.512 0.568 0.947 0.923 0.899 0.876 0.853 0.830 0.808 0.776 0.745 0.715 0.659 522 561 598 633 668 700 732 775 815 853 919 555 599 642 683 724 764 802 856 907 956 1,044 48.47 47.24 45.84 44.64 43.45 42.28 40.80 39.34 37.60 35.90 33.05 1.15 1.12 1.09 1.06 1.03 1.01 0.97 0.94 0.90 0.85 0.79 63.75 63.75 63.75 63.75 63.75 63.75 63.75 63.75 63.75 63.75 63.75 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 31.8 31.8 31.8 31.8 31.8 31.8 31.8 31.8 31.8 31.8 31.8 2.03 2.21 2.41 2.59 2.77 2.95 3.18 3.40 3.68 3.96 4.45 0 . 0 9 5 0 . 1 0 2 0 . 1 0 9 0 . 1 1 6 0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0 . 1 9 0 0.090 0.097 0.104 0.111 0.118 0.128 0.138 0.148 0.167 0.180 1.310 1.296 1.282 1.268 1.250 1.232 1.210 1.188 1.150 1.120 1.429 1.527 1.623 1.719 1.840 1.960 2.104 2.245 2.483 2.665 29,400 31,400 33,300 35,300 37,800 40,300 43,200 46,100 51,000 54,700 33,500 35,800 38,100 40,300 43,200 46,000 49,400 52,700 58,300 62,600 8,300 9,000 9,600 10,200 10,800 11,700 12,600 13,500 15,100 16,200 7,500 8,100 8,600 9,200 9,800 10,600 11,300 12,100 13,600 14,600 0.399 0.428 0.456 0.484 0.512 0.552 0.590 0.629 0.699 0.746 1.368 1.340 1.311 1.283 1.255 1.215 1.177 1.139 1.068 1.021 893 949 1,003 1,055 1,106 1,175 1,242 1,305 1,416 1,486 947 1,011 1,074 1,135 1,194 1,278 1,358 1,436 1,577 1,668 70.02 68.53 67.06 65.60 63.75 61.93 59.74 57.58 53.96 51.18 1.67 1.63 1.60 1.56 1.52 1.47 1.42 1.37 1.28 1.22 91.80 91.80 91.80 91.80 91.80 91.80 91.80 91.80 91.80 91.80 2.19 2.19 2.19 2.19 2.19 2.19 2.19 2.19 2.19 2.19 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 1 . 5 0 0 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 2.41 2.59 2.77 2.95 3.18 3.40 3.68 3.96 4.45 4.83 0 . 1 0 9 0 . 1 1 6 0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0 . 1 9 0 0 . 2 0 4 0.104 0.111 0.118 0.128 0.138 0.148 0.167 0.180 0.195 1.532 1.518 1.500 1.482 1.460 1.438 1.400 1.370 1.342 1.915 2.029 2.175 2.318 2.492 2.662 2.951 3.173 3.377 39,300 41,700 44,700 47,600 51,200 54,700 60,600 65,200 69,400 45,000 47,600 51,100 54,400 58,500 62,500 69,300 74,500 79,300 8,200 8,800 9,300 10,100 10,900 11,600 13,100 14,000 15,100 7,400 7,900 8,400 9,100 9,800 10,500 11,700 12,600 13,600 0.538 0.572 0.605 0.652 0.699 0.745 0.831 0.888 0.953 1.867 1.834 1.800 1.753 1.706 1.660 1.575 1.517 1.453 1,407 1,483 1,558 1,660 1,759 1,854 2,024 2,132 2,250 1,492 1,579 1,665 1,784 1,901 2,014 2,221 2,356 2,506 95.76 94.02 91.80 89.61 86.97 84.37 79.97 76.58 73.48 2.28 2.24 2.19 2.13 2.07 2.01 1.90 1.82 1.75 124.95 124.95 124.95 124.95 124.95 124.95 124.95 124.95 124.95 2.97 2.97 2.97 2.97 2.97 2.97 2.97 2.97 2.97 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 1 . 7 5 0 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5 2.77 2.95 3.18 3.40 3.68 3.96 4.45 4.83 5.18 0 . 1 0 9 0 . 1 1 6 0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0 . 1 9 0 0 . 2 0 4 0.104 0.111 0.118 0.128 0.138 0.148 0.167 0.180 0.195 1.782 1.768 1.750 1.732 1.710 1.688 1.650 1.620 1.592 2.207 2.340 2.509 2.677 2.880 3.080 3.419 3.682 3.923 45,300 48,100 51,500 55,000 59,200 63,300 70,200 75,600 80,600 51,800 54,900 58,900 62,800 67,600 72,300 80,300 86,400 92,100 7,200 7,700 8,200 8,900 9,500 10,200 11,500 12,300 13,300 6,500 6,900 7,400 8,000 8,600 9,200 10,300 11,100 12,000 0.619 0.659 0.698 0.753 0.807 0.861 0.962 1.029 1.106 2.522 2.483 2.444 2.389 2.334 2.280 2.180 2.112 2.036 1,879 1,985 2,088 2,230 2,368 2,501 2,741 2,897 3,067 1,979 2,097 2,213 2,375 2,534 2,690 2,975 3,163 3,372 129.56 127.53 124.95 122.39 119.30 116.25 111.08 107.08 103.41 3.08 3.04 2.97 2.91 2.84 2.77 2.64 2.55 2.46 163.20 163.20 163.20 163.20 163.20 163.20 163.20 163.20 163.20 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 2 . 0 0 0 50.8 50.8 50.8 50.8 50.8 50.8 50.8 50.8 50.8 2.77 2.95 3.18 3.40 3.68 3.96 4.45 4.83 5.18 0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0 . 1 9 0 0 . 2 0 4 0 . 2 2 4 0.118 0.128 0.138 0.148 0.167 0.180 0.195 0.214 2.125 2.107 2.085 2.063 2.025 1.995 1.967 1.927 3.011 3.215 3.462 3.706 4.122 4.445 4.742 5.159 61,900 66,000 71,100 76,100 84,700 91,300 97,400 106,000 70,700 75,500 81,300 87,000 96,800 104,300 111,300 121,100 6,900 7,500 8,100 8,600 9,700 10,500 11,300 12,400 6,200 6,700 7,300 7,800 8,700 9,400 10,200 11,100 0.837 0.904 0.970 1.035 1.158 1.241 1.335 1.453 3.593 3.527 3.460 3.395 3.272 3.189 3.095 2.977 3,028 3,243 3,452 3,655 4,025 4,266 4,533 4,855 3,181 3,421 3,656 3,886 4,313 4,595 4,913 5,301 184.24 181.13 177.37 173.64 167.31 162.38 157.86 151.50 4.39 4.31 4.22 4.13 3.98 3.87 3.76 3.61 230.14 230.14 230.14 230.14 230.14 230.14 230.14 230.14 5.48 5.48 5.48 5.48 5.48 5.48 5.48 5.48 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 60.3 60.3 60.3 60.3 60.3 60.3 60.3 60.3 3.18 3.40 3.68 3.96 4.45 4.83 5.18 5.69

(70™ Data Tabloid+Metric Rev.007 3/99)

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined by user. * Available as continuously milled tubing (CM™) or conventional butt-welded tubing sections (W™). All data is for new tubing at minimum strength. Other sizes and wall thicknesses available on request. See individual size sheets for additional wall thicknesses.

2-5/8", 2-7/8", and other sizes not shown are also available.

(16)

HydroTest

9 0 %

Yield

Minimum

Tensile

Minimum

Internal

Yield Min

Yield

Ultimate

Liters

Liters

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

Nominal

Weight

K g / m

w/ min.

Wall

Internal

Min

DIMENSIONS

(mm)

TUBE LOAD BODY

(Newtons)

INTERNAL

PRESSURE (kPa)

TORSIONAL

YIELD

( N - m )

INTERNAL

CAPACITY

per meter

EXTERNAL

DISPLACEMENT

per meter

TUBING AREA

(sq. cm)

PRECISION

TUBE TECHNOLOGY

HS-70™ GRADE* SELECTED COILED TUBING DATA - METRIC VALUES

Tel. 281-458-2883

Fax. 281458-2886

Email: [email protected]

O . D .

(inches)

Wall

(inches)

(483 N/mm2 Min. Yield Strength; 552 N/mm2 Min. Ult. Strength; 30 % Min. Elongation; Loads calculated using nom. wall)

0.080 0.087 0.095 0.102 0.109 1.000 1.000 1.000 1.000 1.000 2 5 . 4 2 5 . 4 2 5 . 4 2 5 . 4 2 5 . 4 2 . 0 3 2 . 2 1 2 . 4 1 2 . 5 9 2 . 7 7 1.93 2.11 2.29 2.46 2.64 21.3 21.0 20.6 20.2 19.9 1.17 1.26 1.37 1.46 1.55 72,100 77,800 84,100 89,400 95,200 82,300 89,000 96,100 102,300 108,500 64,800 71,000 76,500 82,100 87,600 72,400 78,600 84,800 91,700 97,900 1.42 1.54 1.66 1.78 1.89 3.64 3.52 3.41 3.29 3.18 430 460 490 520 540 470 500 540 570 600 0.36 0.35 0.33 0.32 0.31 0.51 0.51 0.51 0.51 0.51 0.080 0.087 0.095 0.102 0.109 0.116 0.125 0.134 0.145 0.156 0.175 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 3 1 . 8 2 . 0 3 2 . 2 1 2 . 4 1 2 . 5 9 2 . 7 7 2 . 9 5 3 . 1 8 3 . 4 0 3 . 6 8 3 . 9 6 4 . 4 5 1.93 2.11 2.29 2.46 2.64 2.82 3.00 3.25 3.51 3.76 4.24 27.7 27.3 26.9 26.6 26.2 25.9 25.4 24.9 24.4 23.8 22.9 1.49 1.61 1.75 1.86 1.98 2.09 2.24 2.38 2.55 2.72 2.99 91,600 99,200 107,200 114,800 121,900 128,500 137,400 146,300 156,600 166,800 184,100 104,500 113,000 122,800 130,800 139,200 147,200 157,000 167,200 179,300 190,800 210,400 52,400 57,200 62,100 66,200 71,000 75,800 80,000 86,900 93,100 99,300 111,000 57,900 63,400 68,300 73,800 78,600 84,100 88,900 96,500 103,400 110,300 123,400 1.81 1.96 2.12 2.27 2.42 2.56 2.71 2.91 3.11 3.31 3.67 6.11 5.95 5.80 5.65 5.50 5.35 5.21 5.01 4.81 4.61 4.25 710 760 810 860 910 950 990 1,050 1,110 1,160 1,250 750 810 870 930 980 1,040 1,090 1,160 1,230 1,300 1,420 0.60 0.59 0.57 0.55 0.54 0.53 0.51 0.49 0.47 0.45 0.41 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.095 0.102 0.109 0.116 0.125 0.134 0.145 0.156 0.175 0.190 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 3 8 . 1 2 . 4 1 2 . 5 9 2 . 7 7 2 . 9 5 3 . 1 8 3 . 4 0 3 . 6 8 3 . 9 6 4 . 4 5 4 . 8 3 2.29 2.46 2.64 2.82 3.00 3.25 3.51 3.76 4.24 4.57 33.3 32.9 32.6 32.2 31.8 31.3 30.7 30.2 29.2 28.4 2.12 2.27 2.41 2.55 2.73 2.91 3.13 3.34 3.69 3.96 130,800 139,700 148,100 157,000 168,100 179,300 192,200 205,100 226,800 243,300 149,000 159,200 169,500 179,300 192,200 204,600 219,700 234,400 259,300 278,400 51,700 55,800 59,300 63,400 67,600 73,100 77,900 83,400 93,800 100,700 57,200 62,100 66,200 70,300 74,500 80,700 86,900 93,100 104,100 111,700 2.57 2.76 2.94 3.12 3.31 3.56 3.81 4.06 4.51 4.82 8.83 8.64 8.46 8.28 8.10 7.84 7.59 7.35 6.89 6.59 1,210 1,290 1,360 1,430 1,500 1,590 1,680 1,770 1,920 2,020 1,280 1,370 1,460 1,540 1,620 1,730 1,840 1,950 2,140 2,260 0.87 0.85 0.83 0.81 0.79 0.77 0.74 0.72 0.67 0.64 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 0.109 0.116 0.125 0.134 0.145 0.156 0.175 0.190 0.204 1.750 1.750 1.750 1.750 1.750 1.750 1.750 1.750 1.750 4 4 . 5 4 4 . 5 4 4 . 5 4 4 . 5 4 4 . 5 4 4 . 5 4 4 . 5 4 4 . 5 4 4 . 5 2 . 7 7 2 . 9 5 3 . 1 8 3 . 4 0 3 . 6 8 3 . 9 6 4 . 4 5 4 . 8 3 5 . 1 8 2.64 2.82 3.00 3.25 3.51 3.76 4.24 4.57 4.95 38.9 38.6 38.1 37.6 37.1 36.5 35.6 34.8 34.1 2.85 3.02 3.23 3.45 3.70 3.96 4.39 4.72 5.02 174,800 185,500 198,800 211,700 227,700 243,300 269,500 290,000 308,700 200,200 211,700 227,300 242,000 260,200 278,000 308,200 331,400 352,700 51,000 54,500 57,900 62,700 67,600 72,400 80,700 86,900 93,800 56,500 60,700 64,100 69,600 75,200 80,000 90,300 96,500 104,100 3.47 3.69 3.90 4.21 4.51 4.81 5.36 5.73 6.15 12.05 11.83 11.61 11.31 11.01 10.71 10.16 9.79 9.37 1,910 2,010 2,110 2,250 2,390 2,510 2,740 2,890 3,050 2,020 2,140 2,260 2,420 2,580 2,730 3,010 3,190 3,400 1.19 1.17 1.14 1.11 1.08 1.05 0.99 0.95 0.91 1.55 1.55 1.55 1.55 1.55 1.55 1.55 1.55 1.55 0.109 0.116 0.125 0.134 0.145 0.156 0.175 0.190 0.204 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 5 0 . 8 5 0 . 8 5 0 . 8 5 0 . 8 5 0 . 8 5 0 . 8 5 0 . 8 5 0 . 8 5 0 . 8 2 . 7 7 2 . 9 5 3 . 1 8 3 . 4 0 3 . 6 8 3 . 9 6 4 . 4 5 4 . 8 3 5 . 1 8 2.64 2.82 3.00 3.25 3.51 3.76 4.24 4.57 4.95 45.3 44.9 44.5 44.0 43.4 42.9 41.9 41.1 40.4 3.28 3.48 3.73 3.98 4.28 4.58 5.08 5.47 5.83 201,500 213,900 229,100 244,600 263,300 281,600 312,200 336,300 358,500 230,400 244,200 262,000 279,300 300,700 321,600 357,200 384,300 409,700 44,800 47,600 51,000 55,200 59,300 63,400 71,000 76,500 82,700 49,600 53,100 56,500 61,400 65,500 70,300 79,300 84,800 91,700 4.00 4.25 4.50 4.86 5.21 5.56 6.20 6.64 7.13 16.27 16.02 15.77 15.41 15.06 14.71 14.06 13.63 13.13 2,550 2,690 2,830 3,020 3,210 3,390 3,720 3,930 4,160 2,680 2,840 3,000 3,220 3,440 3,650 4,030 4,290 4,570 1.61 1.58 1.55 1.52 1.48 1.44 1.38 1.33 1.28 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 0.125 0.134 0.145 0.156 0.175 0.190 0.204 0.224 2.375 2.375 2.375 2.375 2.375 2.375 2.375 2.375 6 0 . 3 6 0 . 3 6 0 . 3 6 0 . 3 6 0 . 3 6 0 . 3 6 0 . 3 6 0 . 3 3 . 1 8 3 . 4 0 3 . 6 8 3 . 9 6 4 . 4 5 4 . 8 3 5 . 1 8 5 . 6 9 3.00 3.25 3.51 3.76 4.24 4.57 4.95 5.44 54.0 53.5 53.0 52.4 51.4 50.7 50.0 48.9 4.47 4.78 5.14 5.51 6.13 6.61 7.05 7.67 275,300 293,600 316,300 338,500 376,700 406,100 433,200 471,500 314,500 335,800 361,600 387,000 430,600 463,900 495,100 538,700 42,700 46,200 50,300 53,800 60,000 64,800 70,300 76,500 47,600 51,700 55,800 59,300 66,900 72,400 77,900 85,500 5.40 5.83 6.26 6.68 7.47 8.01 8.62 9.37 23.18 22.75 22.32 21.90 21.11 20.57 19.97 19.21 4,110 4,400 4,680 4,960 5,460 5,780 6,150 6,580 4,310 4,640 4,960 5,270 5,850 6,230 6,660 7,190 2.29 2.25 2.20 2.16 2.08 2.02 1.96 1.88 2.86 2.86 2.86 2.86 2.86 2.86 2.86 2.86

(70™ Metric Data Tabloid Rev.007 3/99)

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined by user. * Available as continuously milled tubing (CM™) or conventional butt-welded tubing sections (W™). All data is for new tubing at minimum strength. Other sizes and wall thicknesses available on request. See individual size sheets for additional wall thicknesses.

66.7 mm, 73.0mm, and other sizes not shown are also available.

(17)

O . D .

1"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

1 . 0 0 0

1 . 0 0 0

1 . 0 0 0

1 . 0 0 0

1 . 0 0 0

0 . 0 8 0

0 . 0 8 7

0 . 0 9 5

0 . 1 0 2

0 . 1 0 9

0.076

0.083

0.090

0.097

0.104

0.840

0.826

0.810

0.796

0.782

0.788

0.850

0.920

0.981

1.040

16,200

17,500

18,900

20,100

21,400

18,500

20,000

21,600

23,000

24,400

10,500

11,400

12,300

13,300

14,200

9,400

10,300

11,100

11,900

12,700

0.221

0.239

0.257

0.275

0.293

0.565

0.546

0.528

0.510

0.493

319

341

362

382

401

344

370

395

420

443

1 . 0 0 0

1 . 0 0 0

1 . 0 0 0

1 . 0 0 0

1 . 0 0 0

0.076

0.083

0.090

0.097

0.104

28.79

27.84

26.77

25.85

24.95

0.69

0.66

0.64

0.62

0.59

O . D .

Specified

Wall

Minimum

TUBING AREA

(sq. in.)

DIMENSIONS

(Inches)

Internal

Min.

w/ Wall

Min.

TORSIONAL

YIELD

(ft. / lbs.)

Yield

Ultimate

INTERNAL

CAPACITY

per 1000 ft.

Gallons

Barrels

Gallons

Barrels

EXTERNAL

DISPLACEMENT

per 1000 ft.

40.80

40.80

40.80

40.80

40.80

0.97

0.97

0.97

0.97

0.97

HS-70 CM™

(CONTINUOUSLY-MILLED TUBING)

HS-70 W™

(BUTT-WELDED TUBE SECTIONS)

OR

Available Grades:

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE BODY LOAD

( L b s . )

Yield

Minimum

Tensile

Minimum

INTERNAL

PRESSURE (psi)

HydroTest

9 0 %

Internal

Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and

Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

(18)

O . D .

1

-1/4"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

0 . 0 8 0

0 . 0 8 7

0 . 0 9 5

0 . 1 0 2

0 . 1 0 9

0 . 1 1 6

0 . 1 2 5

0 . 1 3 4

0 . 1 4 5

0 . 1 5 6

0 . 1 7 5

0.076

0.083

0.090

0.097

0.104

0.111

0.118

0.128

0.138

0.148

0.167

1.090

1.076

1.060

1.046

1.032

1.018

1.000

0.982

0.960

0.938

0.900

1.002

1.083

1.175

1.254

1.332

1.408

1.506

1.601

1.715

1.827

2.014

20,600

22,300

24,100

25,800

27,400

28,900

30,900

32,900

35,200

37,500

41,400

23,500

25,400

27,600

29,400

31,300

33,100

35,300

37,600

40,300

42,900

47,300

8,400

9,200

9,900

10,700

11,400

12,200

12,900

14,000

15,000

16,000

17,900

7,600

8,300

9,000

9,600

10,300

11,000

11,600

12,600

13,500

14,400

16,100

0.280

0.304

0.328

0.351

0.374

0.397

0.420

0.451

0.482

0.512

0.568

0.947

0.923

0.899

0.876

0.853

0.830

0.808

0.776

0.745

0.715

0.659

522

561

598

633

668

700

732

775

815

853

919

555

599

642

683

724

764

802

856

907

956

1,044

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

1 . 2 5 0

0.076

0.083

0.090

0.097

0.104

0.111

0.118

0.128

0.138

0.148

0.167

48.47

47.24

45.84

44.64

43.45

42.28

40.80

39.34

37.60

35.90

33.05

1.15

1.12

1.09

1.06

1.03

1.01

0.97

0.94

0.90

0.85

0.79

O . D .

Specified

Wall

Minimum

TUBING AREA

(sq. in.)

DIMENSIONS

(Inches)

Internal

Min.

w/ Wall

Min.

TORSIONAL

YIELD

(ft. / lbs.)

Yield

Ultimate

INTERNAL

CAPACITY

per 1000 ft.

Gallons

Barrels

Gallons

Barrels

EXTERNAL

DISPLACEMENT

per 1000 ft.

63.75

63.75

63.75

63.75

63.75

63.75

63.75

63.75

63.75

63.75

63.75

1.52

1.52

1.52

1.52

1.52

1.52

1.52

1.52

1.52

1.52

1.52

HS-70 CM™

(CONTINUOUSLY-MILLED TUBING)

HS-70 W™

(BUTT-WELDED TUBE SECTIONS)

OR

Available Grades:

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE BODY LOAD

( L b s . )

Yield

Minimum

Tensile

Minimum

INTERNAL

PRESSURE (psi)

HydroTest

9 0 %

Internal

Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and

Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

(19)

O . D .

1

-1/2"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

0 . 0 9 5

0 . 1 0 2

0 . 1 0 9

0 . 1 1 6

0 . 1 2 5

0 . 1 3 4

0 . 1 4 5

0 . 1 5 6

0 . 1 7 5

0 . 1 9 0

0.090

0.097

0.104

0.111

0.118

0.128

0.138

0.148

0.167

0.180

1.310

1.296

1.282

1.268

1.250

1.232

1.210

1.188

1.150

1.120

1.429

1.527

1.623

1.719

1.840

1.960

2.104

2.245

2.483

2.665

29,400

31,400

33,300

35,300

37,800

40,300

43,200

46,100

51,000

54,700

33,500

35,800

38,100

40,300

43,200

46,000

49,400

52,700

58,300

62,600

8,300

9,000

9,600

10,200

10,800

11,700

12,600

13,500

15,100

16,200

7,500

8,100

8,600

9,200

9,800

10,600

11,300

12,100

13,600

14,600

0.399

0.428

0.456

0.484

0.512

0.552

0.590

0.629

0.699

0.746

1.368

1.340

1.311

1.283

1.255

1.215

1.177

1.139

1.068

1.021

893

949

1,003

1,055

1,106

1,175

1,242

1,305

1,416

1,486

947

1,011

1,074

1,135

1,194

1,278

1,358

1,436

1,577

1,668

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

1 . 5 0 0

0.090

0.097

0.104

0.111

0.118

0.128

0.138

0.148

0.167

0.180

70.02

68.53

67.06

65.60

63.75

61.93

59.74

57.58

53.96

51.18

1.67

1.63

1.60

1.56

1.52

1.47

1.42

1.37

1.28

1.22

O . D .

Specified

Wall

Minimum

TUBING AREA

(sq. in.)

DIMENSIONS

(Inches)

Internal

Min.

w/ Wall

Min.

TORSIONAL

YIELD

(ft. / lbs.)

Yield

Ultimate

INTERNAL

CAPACITY

per 1000 ft.

Gallons

Barrels

Gallons

Barrels

EXTERNAL

DISPLACEMENT

per 1000 ft.

91.80

91.80

91.80

91.80

91.80

91.80

91.80

91.80

91.80

91.80

2.19

2.19

2.19

2.19

2.19

2.19

2.19

2.19

2.19

2.19

HS-70 CM™

(CONTINUOUSLY-MILLED TUBING)

HS-70 W™

(BUTT-WELDED TUBE SECTIONS)

OR

Available Grades:

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE BODY LOAD

( L b s . )

Yield

Minimum

Tensile

Minimum

INTERNAL

PRESSURE (psi)

HydroTest

9 0 %

Internal

Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and

Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

(20)

O . D .

1

-3/4"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

0 . 1 0 9

0 . 1 1 6

0 . 1 2 5

0 . 1 3 4

0 . 1 4 5

0 . 1 5 6

0 . 1 7 5

0 . 1 9 0

0 . 2 0 4

0.104

0.111

0.118

0.128

0.138

0.148

0.167

0.180

0.195

1.532

1.518

1.500

1.482

1.460

1.438

1.400

1.370

1.342

1.915

2.029

2.175

2.318

2.492

2.662

2.951

3.173

3.377

39,300

41,700

44,700

47,600

51,200

54,700

60,600

65,200

69,400

45,000

47,600

51,100

54,400

58,500

62,500

69,300

74,500

79,300

8,200

8,800

9,300

10,100

10,900

11,600

13,100

14,000

15,100

7,400

7,900

8,400

9,100

9,800

10,500

11,700

12,600

13,600

0.538

0.572

0.605

0.652

0.699

0.745

0.831

0.888

0.953

1.867

1.834

1.800

1.753

1.706

1.660

1.575

1.517

1.453

1,407

1,483

1,558

1,660

1,759

1,854

2,024

2,132

2,250

1,492

1,579

1,665

1,784

1,901

2,014

2,221

2,356

2,506

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

1 . 7 5 0

0.104

0.111

0.118

0.128

0.138

0.148

0.167

0.180

0.195

95.76

94.02

91.80

89.61

86.97

84.37

79.97

76.58

73.48

2.28

2.24

2.19

2.13

2.07

2.01

1.90

1.82

1.75

O . D .

Specified

Wall

Minimum

TUBING AREA

(sq. in.)

DIMENSIONS

(Inches)

Internal

Min.

w/ Wall

Min.

TORSIONAL

YIELD

(ft. / lbs.)

Yield

Ultimate

INTERNAL

CAPACITY

per 1000 ft.

Gallons

Barrels

Gallons

Barrels

EXTERNAL

DISPLACEMENT

per 1000 ft.

124.95

124.95

124.95

124.95

124.95

124.95

124.95

124.95

124.95

2.97

2.97

2.97

2.97

2.97

2.97

2.97

2.97

2.97

HS-70 CM™

(CONTINUOUSLY-MILLED TUBING)

HS-70 W™

(BUTT-WELDED TUBE SECTIONS)

OR

Available Grades:

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE BODY LOAD

( L b s . )

Yield

Minimum

Tensile

Minimum

INTERNAL

PRESSURE (psi)

HydroTest

9 0 %

Internal

Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and

Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

(21)

O . D .

2"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

0 . 1 0 9

0 . 1 1 6

0 . 1 2 5

0 . 1 3 4

0 . 1 4 5

0 . 1 5 6

0 . 1 7 5

0 . 1 9 0

0 . 2 0 4

0.104

0.111

0.118

0.128

0.138

0.148

0.167

0.180

0.195

1.782

1.768

1.750

1.732

1.710

1.688

1.650

1.620

1.592

2.207

2.340

2.509

2.677

2.880

3.080

3.419

3.682

3.923

45,300

48,100

51,500

55,000

59,200

63,300

70,200

75,600

80,600

51,800

54,900

58,900

62,800

67,600

72,300

80,300

86,400

92,100

7,200

7,700

8,200

8,900

9,500

10,200

11,500

12,300

13,300

6,500

6,900

7,400

8,000

8,600

9,200

10,300

11,100

12,000

0.619

0.659

0.698

0.753

0.807

0.861

0.962

1.029

1.106

2.522

2.483

2.444

2.389

2.334

2.280

2.180

2.112

2.036

1,879

1,985

2,088

2,230

2,368

2,501

2,741

2,897

3,067

1,979

2,097

2,213

2,375

2,534

2,690

2,975

3,163

3,372

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

2 . 0 0 0

0.104

0.111

0.118

0.128

0.138

0.148

0.167

0.180

0.195

129.56

127.53

124.95

122.39

119.30

116.25

111.08

107.08

103.41

3.08

3.04

2.97

2.91

2.84

2.77

2.64

2.55

2.46

O . D .

Specified

Wall

Minimum

TUBING AREA

(sq. in.)

DIMENSIONS

(Inches)

Internal

Min.

w/ Wall

Min.

TORSIONAL

YIELD

(ft. / lbs.)

Yield

Ultimate

INTERNAL

CAPACITY

per 1000 ft.

Gallons

Barrels

Gallons

Barrels

EXTERNAL

DISPLACEMENT

per 1000 ft.

163.20

163.20

163.20

163.20

163.20

163.20

163.20

163.20

163.20

3.89

3.89

3.89

3.89

3.89

3.89

3.89

3.89

3.89

HS-70 CM™

(CONTINUOUSLY-MILLED TUBING)

HS-70 W™

(BUTT-WELDED TUBE SECTIONS)

OR

Available Grades:

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE BODY LOAD

( L b s . )

Yield

Minimum

Tensile

Minimum

INTERNAL

PRESSURE (psi)

HydroTest

9 0 %

Internal

Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and

Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

(22)

O . D .

2

-3/8"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

0 . 1 2 5

0 . 1 3 4

0 . 1 4 5

0 . 1 5 6

0 . 1 7 5

0 . 1 9 0

0 . 2 0 4

0 . 2 2 4

0.118

0.128

0.138

0.148

0.167

0.180

0.195

0.214

2.125

2.107

2.085

2.063

2.025

1.995

1.967

1.927

3.011

3.215

3.462

3.706

4.122

4.445

4.742

5.159

61,900

66,000

71,100

76,100

84,700

91,300

97,400

106,000

70,700

75,500

81,300

87,000

96,800

104,300

111,300

121,100

6,900

7,500

8,100

8,600

9,700

10,500

11,300

12,400

6,200

6,700

7,300

7,800

8,700

9,400

10,200

11,100

0.837

0.904

0.970

1.035

1.158

1.241

1.335

1.453

3.593

3.527

3.460

3.395

3.272

3.189

3.095

2.977

3,028

3,243

3,452

3,655

4,025

4,266

4,533

4,855

3,181

3,421

3,656

3,886

4,313

4,595

4,913

5,301

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

2 . 3 7 5

0.118

0.128

0.138

0.148

0.167

0.180

0.195

0.214

184.24

181.13

177.37

173.64

167.31

162.38

157.86

151.50

4.39

4.31

4.22

4.13

3.98

3.87

3.76

3.61

O . D .

Specified

Wall

Minimum

TUBING AREA

(sq. in.)

DIMENSIONS

(Inches)

Internal

Min.

w/ Wall

Min.

TORSIONAL

YIELD

(ft. / lbs.)

Yield

Ultimate

INTERNAL

CAPACITY

per 1000 ft.

Gallons

Barrels

Gallons

Barrels

EXTERNAL

DISPLACEMENT

per 1000 ft.

230.14

230.14

230.14

230.14

230.14

230.14

230.14

230.14

5.48

5.48

5.48

5.48

5.48

5.48

5.48

5.48

HS-70 CM™

(CONTINUOUSLY-MILLED TUBING)

HS-70 W™

(BUTT-WELDED TUBE SECTIONS)

OR

Available Grades:

O . D .

Specified

Wall

Specified

Wall

Minimum

I . D .

Calculated

DIMENSIONS

(Inches)

Nominal

Weight

Lbs. / ft.

TUBE BODY LOAD

( L b s . )

Yield

Minimum

Tensile

Minimum

INTERNAL

PRESSURE (psi)

HydroTest

9 0 %

Internal

Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and

Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

References

Related documents

patients treated for recurrent disease, 6 had received prior head and neck radiation, 6 had skull base involvement, and 3 had.. known distant metastatic pulmonary disease, but

Knowing unique characteristics of speech Knowing limitation of speech recognition Identify the

a multiphonic fingering on the oboe may not work on the cor anglais, or may work but produce quite a different multiphonic and not simply the same pitches transposed down a 5th.

The model is validated against experimental data available for droplets suspended on a small diameter pipe in a hot air environment under convective flow

Boström Windhamre HA, von Heideken JP, Une- Larsson VE, Ekelund AL: Surgical treatment of chronic acromioclavicular dislocations: A comparative study of Weaver-Dunn augmented

The POC component utilizes PULSE-WAVE Delivery and offers lightweight comfort with up to 12.5 hours of internal battery life.. Standard 3-Year

THAT the Alberni Valley Committee approve the Alberni Valley Landfill & Bamfield Waste Management budget for inclusion in first reading of the 2015‐2019 Alberni‐Clayoquot

2.6 The MID-AMC STG1 noted Status of Implementation of the AMHS in the MID Region, where six (6) States have operational AMHS links, three (3) States have signed a contract