• No results found

Krc2 Pci Modem

N/A
N/A
Protected

Academic year: 2021

Share "Krc2 Pci Modem"

Copied!
12
0
0

Loading.... (view fulltext now)

Full text

(1)

Page 1 -2 KUKA Roboter GmbH - Installation / Removal Instructions

Version:

Date of issue: 02 Jun 05 00

KR C2 edition2005

PCI Modem for KPC edition2005

Europe and USA

(2)

Page 2 -2 Installation / Removal Instructions „PCI Modem for KPC edition2005“

© Copyright 2005

KUKA Roboter GmbH Hery Park 3000

86368 Gersthofen, Germany

This document or excerpts thereof may not be reproduced or disclosed to third parties without the express permission of the publishers.

Other functions not described in this documentation may be operable in the controller. The user has no claims to these functions, however, in the case of a replacement or service work.

We have checked the content of this documentation for conformity with the hardware and software described. Nevertheless, discrepancies cannot be precluded, for which reason we are not able to guarantee total conformity. The information in this documentation is checked on a regular basis, however, and necessary corrections will be incorporated in subsequent editions. Subject to technical alterations without an effect on the function.

(3)

Contents

KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ Page 3 -4

1

Introduction. . . 5

1.1

Use . . . .5

1.2

Terms and abbreviations used . . . .6

2

Safety . . . 7

2.1

Fundamentals . . . .7

2.2

Liability . . . .7

2.3

Designated use . . . .7

3

Installation and removal . . . 8

3.1

Installation . . . .9

3.2

Removal . . . .10

4

Start-up. . . 11

4.1

Establish modem connection . . . .11

(4)

Contents

KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

(5)

Introduction

Page 5 -12

KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

1

Introduction

The following documentation describes the installation and removal of the PCI modem plug-in card (Europe and USA) for the KR C2 edition2005 controller.

1.1

Use

Providing the NSM remote control function

The PCI modem may be installed on the following motherboards only:

Soyo 7VBA (slot 3);

FSC D1688 (slot 6).

The KUKA counting direction for the PCI slots is the opposite of the counting direction on the motherboard.

The slot specifications are based on the KUKA counting direction.

The PCI modem is authorized for use with the Windows XP operating system only.

In addition to the modem connection (Figure 1 [1]), the USA variant of the PCI modem has a second connection (Figure 1 [2]) for operating a telephone.

Use of the telephone connection is not permissible.

Fig.1 PCI modem connections (USA variant)

1 2

(6)

Introduction

Page 6 -12 KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

1.2

Terms and abbreviations used

The following terms and abbreviations are used in these Installation and Removal Instructions:

Typographical conventions:

Term/Abbreviation Meaning

GUI KUKA user interface

KPC KUKA PC

KR C2 edition2005 KUKA Robot Control (robot control cabinet)

PCI Peripheral Component Interconnect

Example Meaning

1. Numbering indicates instructions.

This symbol is used for bulleted lists. „U.S. Robotics

PCI Modem“

Names of operator control and display elements, buttons and program names are placed in quotation marks.

Start > Settings > Control Panel

Selection of the Control Panel submenu in the Settings submenu of the

(7)

Safety

Page 7 -12

KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

2

Safety

2.1

Fundamentals

W A R N I N G !

Failure to observe these safety instructions could result in injury or a fatal accident and/or damage to the robot system or other property!

All pertinent safety regulations as well as the booklet [Safety and Installation Instructions] are to be observed when working on the system.

The KUKA safety chapter [KR C Safety, General] is supplied with the robot system and must be read and understood before commencing work.

The safety instructions in the „KR C2 edition2005“ Operating Handbook must be observed.

2.2

Liability

Connection and use of the PCI modem card must be carried out in compliance with this documentation.

2.3

Designated use

Using this product for any purpose other than or additional to that described in Section 1.1 is considered contrary to its designated use. The manufacturer cannot be held liable for any damage resulting from such use.

The risk lies entirely with the user.

(8)

Installation and removal

Page 8 -12 KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

3

Installation and removal

W A R N I N G !

The robot system must be switched off before exchange, adjustment, maintenance and repair in accordance with the regulations contained in these operating instructions, i.e. the main switch on the KR C2 edition2005 control cabinet must be turned to „OFF“ and secured with a padlock to prevent it from inadvertently being switched on again.

N o t e !

The ESD directives (ESD: electrostatic sensitive devices) must be observed at all times when handling modules for use in the KR C2 edition2005 (see „Safety, General“, Section 7, ESD directives).

(9)

Installation and removal

Page 9 -12

KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

3.1

Installation

1. Select the Force cold start option before switching off the KR C2 control.

2. Open the cabinet door of the KR C2 edition2005 control cabinet and the PC chassis door. 3. Check the PCI modem card for mechanical damage.

4. Depending on the motherboard used, plug the PCI modem card into PCI slot 3 or 6.

When plugging the card in, hold the front plate of the card with one hand (Figure 2 [1]) and the opposite edge of the card with the other hand and push the card into the slot, holding it straight.

5. Connect the cable (strain relieved) to the modem and fasten the modem cable, e.g. with cable straps, to the cable harness that leads to the PC.

For modem connection of the Europe variant, see Figure 2 [2]. For modem connection of the USA variant, see Figure 2 [3].

6. Close and lock the PC chassis door and the cabinet door of the KR C2 edition2005 control cabinet.

Fig.2 PCI modem (Europe and USA)

2 1

1

(10)

Installation and removal

Page 10 -12 KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

N o t e !

Only install the driver software for the PCI modem if: - the Windows XP operating system has been started and - the GUI has not yet been started.

7. Switch the KR C2 edition2005 control cabinet on. Prevent the KR C2 controller software (Cross3) from loading by pressing the Shift + Ctrl keys simultaneously.

8. Insert the CD-ROM with the driver software into the CD-ROM drive and follow the instructions on the screen. The modem drivers are installed automatically.

9. Once the installation of the driver software has been completed successfully, start the KR C2 controller software (Cross3).

3.2

Removal

N o t e !

Only uninstall the driver software for the PCI modem if: - the Windows XP operating system has been started and - the GUI has not yet been started.

Do not uninstall the driver software in the Device Manager.

1. Select Start > Settings > Control Panel from the Windows task bar and then click on Software.

2. Select the entry „U.S. Robotics PCI Modem“ and then the Add/Remove Programs button. Follow the instructions on the screen.

3. Shut down the KR C2 controller.

4. Remove the PCI modem card from the PC. To do this, reverse the steps described in the installation procedure (see Section 3.1).

(11)

Start-up

Page 11 -12

KUKA Roboter GmbH - Installation / Removal Instructions „PCI Modem for KPC edition2005“ - Version 00

4

Start-up

4.1

Establish modem connection

N o t e !

Only establish the modem connection with the GUI running.

4.2

Disconnect modem connection

N o t e !

(12)

Start-up

References

Related documents

After Windows has removed the Modem software, remove the Modem card from your machine (continue to the Removing 3Com ADSL Modem PCI hardware section, if necessary).. Your Modem is

Rear Panel Mounting the Telephony Modem Tools and Materials Location Instructions Wall-mounting instructions Desktop mounting instructions Connecting the Telephony Modem Making

Total coliforms: Coliform organisms, better referred to as total coliforms to avoid confusion with others in the group, are not an index of faecal pollution or of health risk, but

Text to Screen Adaptation: Examining Reverse Ekphrasis in Joe Wright’s Films Adapting for..

On this view, after having determined our animal's ability to learn, the simplicity or complexity of its methods of learning, the effect of past habit upon present

The results of this study demonstrate the need to provide teachers in this district with additional training on how to meet the educational needs of students with dyslexia in their

A Console DB-9 Connect to a modem that may be supplied by Lucent or by the customer for remote access.. (see page 12 for modem installation

RocketPort PCI, Universal PCI or Plus Univer- sal PCI 17 Straight-through cable 17 , 23 RS-422 DB25 loopback plug Female 14 Male 14 DB9 Loopback plug 11 , 20 Null-modem cable 11 ,