• No results found

IIMVERTER SINGLE SPLIT

N/A
N/A
Protected

Academic year: 2021

Share "IIMVERTER SINGLE SPLIT"

Copied!
5
0
0

Loading.... (view fulltext now)

Full text

(1)

Life's Good

LG AIR CONDITIONER

IIMVERTER

SINGLE SPLIT

(2)

Why LG

Inverter Single Split?

Recognizing the importance of saving energy, LG has taken the initiative to develop new, more efficient inverter technology In addition to consuming less electricity the company's advanced inverter systems also boast powerful performance and enhanced reliability.

LG's Inverter Single Split lowers energy usage and operational costs, illustrating how clever technology can make a real difference. Designed for commercial spaces such as offices and retail stores, the new model can opérate for extended pehods of time, while also providing exceptional seasonal energy effíciency

The Inverter Single Split is able to produce an impressive volume of cool ain helping to créate the perfect indoor temperature in almost no time at all. As well as delivering fast and efficient cooling, LG's latest solution can also minimize electricity consumption by as much as 40 percent.

Comfortabi^ Operation

Once the desired temperature is achieved, unlike conventional air conditioners that turn the compressor on and off LG inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised.

Conventional , LG Inverter

Temprature Temprature

Setting Temprature

Room Temprature Power On Power Off Room Temprature Power On

(3)

Excellent

Energy Saving World Top Class

LG's advanced inverter technology leads to powerful performance while minimizing energy consumption. It will bring you greater cost saving over the product life time.

Cassette

3.65 17

ATNQ24GNLE3

Annual Power Consumption

Conventional LG Inverter

Total Cost of Ownership Cost($)

4,000 3,000 2,000 1,000

mtm Conventional

^ LG Inverter

J I I I I I I I I l_

2 Period (Year)

Duct

3.23 16

World Top Class J

Convertible

5,027

Annual Power Consumption (kWh)

5,000 4,000 3,000 2,000 1,000

Conventional LG Inverter

Totat Cost of Ownership Conventional LG Inverter

3.02 16

^ ^ W o r í ^ l o p a ^ s ^ ^

Annual Power Consumption 7.973

Total Cost of Ownership ~

Conventional LG Inverter

Cassette / Duct 1 - Calculation based on regional temperature condition of Jakarta, Indonesia 2. Electric Charge (Commercial): 0.12 $ / kWh 3. Initial cost: Product pnce installation cost 4. Operation duration : 9 hours/day (09:00-18:00) S 6 days/week 5. Cooling peak load: based on 7kW

rnr»«ir+ikla 1 Calcutation based on reoional temoerature condition of Bangkok, Thailand 2. Electric Charge (Commercial): 0.1 $ / kWh 3. Initial cost; Product pnce +

(4)

Ceiling Suspended

Indoor i AVI\1Q24GJLA0

Capacity Min.-Rated-Max. kW 2.8 - 7.00 - 8,0

Capacity Cooling

Min.-Rated-Max. Btü/h 9,600 - 23,900 - 27,300

Running Cun-ent A 10.1

Power Supply V / 0 / H z 22OV/01 / 5 0 / 6 0 H Z

EER/COP 3.02/2.60

SEER 16

Air Flow Rate H / M / L m3/m¡n 1 2 . 4 / 1 1 . 4 / 1 0 . 4

Air Flow Rate

H / M / L ft3/min 4 3 8 / 4 0 3 / 3 6 7

Sound Pressure Level H / M / L dB(A) 4 4 / 4 3 / 4 1

Dimmensions Body W x H x D mm 950 X 650 X 220

Dimmensions

Packing W x H x D mm 1 , 0 5 2 x 3 1 6 x 7 4 7

Weight Net kg 2 0 5

Weight

Gross kg 25.7

Liquid mm(inch) 0 9.52 (3/8)

Piping connections Gas mm(inch) 0 15.88 (5/8)

Drain (O.D./I.D.) mm 0 21.5/16.0

Outdoor AUUQ24GH1

Capacity Min.-Rated-Max. kW 2.8 - 7.00 - 8.0

Capacity Cooling Min.-Rated-Max. Btu/h 9 , 6 0 0 - 2 3 , 9 0 0 - 2 7 3 0 0

Power Input Rated kW 1.92

Compressor Type Twin Rotary

Air Flow Rate m^/min 5 0 x 1

Sound Pressure Level dBA 48

Dimmensions Body W x H x D mm 870 X 655 X 320

Dimmensions

Packing W x H x D mm 1 , 0 2 2 x 7 1 6 x 4 3 7

Weight Net kg 44.0

Weight

Gross kg 48.1

Type R410A

Refrigerant Precharged

Amount 9 1,100

Additional Charg-

inq Volume g/m 40

Operation Range (Outdoor) Min. - Max. oCDB - 1 5 - 4 8

Power Supply V / 0 / H z 22Ov/01 / 5 0 / 6 0 H Z

Power Supply Cable No. x mm2 3C X 2,5

Transmission Cable No. X mm^ 4 C x 0 7 5

Circuit Breaker A 25

• Piping Length Max. m(ft) 50(164.0)

Máximum Height Difference ODU - IDU Max. m(ft) 30 (98.4)

Piping Conneaions Liquid mm(inch) 0 9.52 (3/8)

Piping Conneaions

Gas mm(inch)" 0 1 5.88 (5/8)

Note : 1 . Capacities are based on the folloming conditions Cooling : Indoor Temperature 27°C DB / 19°C W B / Outdoor Temperature 35°C DB / 24°C W B Heating: Indoor Temperature 20°C DB /15°C W B / Outdoor Temperature 7°C DB / 6°C W B 2. Annual energy consumption based on average use of 500 running hours per year at Ratedinal condition

* Due to our policy of innovation some specifications may be changed without notification.

(5)

1 AVNQ36GKLA0 AVNQ42GLLA0 A\/IMQ48GLLA0 A\/NQ54GLLA0

4 . 0 - 1 0 . 0 - 11 0 5.0- 12 5 - 1 3 . 1 5 . 3 6 - 1 3 . 4 - 147 6.32 - 15.8 - 16.6

13,600 - 34,100 - 37,500 1 7 , 0 0 0 - 4 2 , 7 0 0 - 4 5 , 0 0 0 18,300 - 45,700 - 50,200 2 1 , 6 0 0 - 5 3 , 9 0 0 - 5 6 , 6 0 0

1 4 4 16.9 19.3 2 2 7

22Ov/01 / 5 0 / 6 0 H Z 22OV/01 / 5 0 / 6 0 H Z 22OV/01 / 5 0 / 6 0 H Z 22OV/01 / 5 0 / 6 0 H Z

3.02 / 2.60 3.22/2.50 3.02 / 2.50 3.02 / 2.80

16 16 16 16

2 1 4 / 1 9 . 8 / 1 8 . 2 2 8 . 6 / 2 6 . 9 / 2 5 . 2 3 0 . 0 / 2 8 . 3 / 2 6 . 6 3 1 . 5 / 2 9 . 7 / 2 8 . 0 756 / 699 / 643 1 , 0 1 0 / 9 5 0 / 8 9 0 1 , 0 6 0 / 9 9 9 / 9 3 9 1 . 1 1 2 / 1 , 0 4 9 / 9 8 9

4 5 / 4 3 / 4 1 4 7 / 4 6 / 4 4 4 7 / 4 6 / 4 4 4 8 / 4 7 / 4 5

1 , 3 5 0 x 6 5 0 x 2 2 0 1 , 7 5 0 x 6 5 0 x 2 2 0 1 , 7 5 0 x 6 5 0 x 220 1 , 7 5 0 x 6 5 0 x 220 1 , 0 5 2 x 3 1 6 x 7 4 7 1 , 0 5 2 x 3 1 6 x 7 4 7 1 , 0 5 2 x 3 1 6 x 7 4 7 1 , 0 5 2 x 3 1 6 x 7 4 7

29.0 35.0 3 5 0 35.0

3 5 5 43.5 43.5 43.5

0 9.52(3/8) 0 9.52 (3/8) 0 9.52 (3/8) 0 9.52 (3/8)

0 1 5.88 (5/8) 0 1 5.88 (5/8) 0 15.88 (5/8) 0 19.05 (3/4)

0 2 1 . 5 / 1 6 . 0 0 21.5/16.0 0 2 1 . 5 / 1 6 . 0 0 21.5/16.0

AUUQ36GH1 AUUQ42GH1 | AUUQ48GH1 AUUQ54GH1

4 . 0 - 1 0 . 0 - 1 1 . 0 5 , 0 - 1 2 . 5 - 1 3 . 2 5 . 3 6 - 1 3 . 4 - 1 4 7 6 . 3 2 - 1 5 . 8 - 1 6 . 6 13,600 - 34.100 - 3 7 5 0 0 1 7 , 0 0 0 - 4 2 , 7 0 0 - 4 5 , 0 0 0 18,300 - 45,700 - 50,200 2 1 , 6 0 0 - 5 3 , 9 0 0 - 5 6 , 6 0 0

2.90 3.73 4.44 5.23

Twin Rotary Twin Rotary Twin Rotary Twin Rotary

5 8 x 1 60 X 1 6 0 x 1 5 5 x 2

48 52 52 55

950 X 834 X 330 950 X 834 X 330 950 X 834 X 330 950 X 1 , 3 8 0 x 3 3 0

1 , 0 4 0 x 9 1 8 x 4 6 1 1 , 0 4 0 x 9 1 8 x 4 6 1 1 , 0 4 0 x 9 1 8 x 4 6 1 1 , 0 4 0 x 1 4 6 2 x 4 6 1

65.0 6 7 0 '67.0 • 96.0

71 8 73.8 73.8 1071

R410A R410A R410A R410A

1,900 2,300 2,300 3,300

40 40 40 40

- 1 5 - 4 8 - 1 5 - 4 8 - 1 5 - 4 8 - 1 5 - 4 8

22OV/01 /50/60HZ 22OV/01 /50/60HZ 22OV/01 / 5 0 / 6 0 H Z 22Ov/01 /50/60HZ

3C X 4 0 3 C x 5 . 0 3C X 5.0 3C x 5.0

4CxO,75 4C X 0.75 4 0 x 0 . 7 5 4 C x 0 7 5

30 40 40 40

50(164,0) 50(164.0) 50(154.0) 50 (164.0)

30 (98,4) 30 (98.4) 30 (98.4) 30 (98.4)

0 9,52(3/8) 0 9.52 (3/8) 0 9.52(3/8) 0 9.52 (3/8)

0 15,88 (5/8) 0 15.88 (5/8) 0 15.88 (5/8) 019.05 (3/4)

Note : 1. Capacities are based on the fotlowing conditions Cooling : Indoor Temperature 27°C DB/19°C W B / Outdoor Temperature 35°C DB / 24°CWB Heating: Indoor Temperature 20°C DB /15°C W B / Outdoor Temperature 7°C DB / 6°C W B 2. Annuai energy consumption based on average use of 500 running hours per year at Ratedinal condition

* Due to our policy of innovation some specifications may be changed without notification.

References

Related documents

Therefore, this review highlighted the drying methods for municipal solid waste quality improvement around the world and compared them based on the reduction of moisture, weight

○ If BP elevated, think primary aldosteronism, Cushing’s, renal artery stenosis, ○ If BP normal, think hypomagnesemia, severe hypoK, Bartter’s, NaHCO3,

According to the findings on objective three, the statutory protection to the right to privacy against mobile phone usage does not provide direct clue as majority of the

Finite Sample Performance of Frequency and Time Domain Tests for Seasonal Fractional Integration..

The summary resource report prepared by North Atlantic is based on a 43-101 Compliant Resource Report prepared by M. Holter, Consulting Professional Engineer,

[r]

Therefore, we hypothesize: Under the condition that people have no paid job, immigrants with more social capital are more likely to receive an

As consequences, ground movements triggered by earthquakes in the form of transient ground deformation (TGD), caused by the passage of seismic waves (ground shaking) which is