• No results found

EEG Basic Concept

N/A
N/A
Protected

Academic year: 2021

Share "EEG Basic Concept"

Copied!
33
0
0

Loading.... (view fulltext now)

Full text

(1)Fundamental of Electroencephalogram (EEG) Prepared by: Eng. Alshimaa Abd-Elaal Mohamed.

(2) Introduction ¾ The electroencephalogram (EEG) was first measured in humans by Hans Berger in 1929. Berger was the first to record the electrical activity of the human brain. ¾Electrical impulses generated by nerve firings in the brain can be measured by electrodes placed on the scalp. ¾The EEG gives a coarse view of neural activity and has been used to non-invasively study the physiology of the brain. ¾ He was the first to record an epileptic seizures. ¾ EEG activity is quite small signal, measured in microvolt (µV) with the main frequencies of interest up to approximately 30 Hertz (Hz)..

(3) ¾Signal range : 2µV (brain death ) – several hundred µV. ¾The frequency bands in EEG: 1- Delta (<4 Hz): deep sleep stages of normal adults. 2- Theta (4-8 Hz): normal infants and children as well as during drowsiness and sleep in adults. 3- Alpha (8-14 Hz): mostly below 50 µV, normal adults during relaxed and mentally inactive awake ness. 4- Beta (14-30 Hz): mostly below 30 µV , It is enhanced by expectancy states and tension. 5- Gamma (>30 Hz): Usually, it is not of clinical and physiological interests and therefore often filtered out in EEG recordings.

(4)

(5) Physiological Artifacts.

(6) Non-Physiological Artifacts.

(7) EEG machine consists of the following components:. 1- Electrodes. 2- Amplifiers. 3- Filters. 4- Recording unit..

(8) Analog EEG System Head Box. Input Select Switches. Low Frequency Filter Calibration Pulse. High Frequency Filter. Notch Filter. PA. Differential Amplifier.

(9) Digital EEG system Head Box. Computer Ch 1. Fixed Band pass Filter. Mux. A/D Converter Ch n. Ref. GND. Fixed Band pass Filter.

(10) EEG electrode • Electrode: means whereby the electrical activity of the brain communicated to the input circuit of the amplifier in the EEG machine, Metal is the material of which the electrode is composed. • Electrolyte: may be conducting solution (gel or paste) or may be fluid of living tissue as when electrode inserted below skin. It is salt solution, principally sodium chloride. This means that current flow within brain becomes electron flow in the electrodes and electrode wires.. To understand how electrical current pass through metalelectrolyte interface. we must know some basic of electrical properties of electrolyte: ‰ Ions is particles in solution that bear an electrical charge. The fact that ions are free to move in the solution, so if applied voltage between two points in the solution, an electric current can be made to flow in it..

(11) The current carried by ions in the solution in the same way that current is carried by the loosely bound electrons in a metallic conductor and this is appropriate with electrode potentials.. Metal – electrolyte interface: It is the junction where flow of ions is converted into flow of electrons. It is the place where an electrochemical phenomenon is converted into purely electrical phenomenon..

(12) Types of electrodes.

(13) Electrode Design Two identical pieces of felt cutting into circles big enough fit onto the suction cups. Silver wire is bent around the two pieces of felt into a U- shape.. Flat electrode. Cup electrode.

(14) ¾ electrodes are placed on the scalp in special positions. These positions are identified by the recorders who measures the head using the International 10/20 System.. ¾There are two different types of EEG signals depending on where the signal is taken in the head: scalp or intracranial. For scalp EEG, electrodes, are placed on the scalp with good mechanical and electrical contact. In intracranial EEG (IEEG), the EEG signal is obtained by special electrodes implanted in the brain surface during a surgery..

(15) ¾ The brain (cerebrum) is formed of two cerebral hemispheres, right and left. ¾ Each cerebral hemisphere is formed of four lobes: 1- Frontal lobe: contains motor area. 2- Parietal lobe: contains sensory area. 3- Temporal lobe: contains area of hearing & memory. 4- Occipital lobe: contains area of vision..

(16)

(17) ¾ EEG system cover all parts of brain by placing electrode on all part of head.. ¾ There are two system of electrode placement: 1- 10-20 international system: includes 21 electrodes. 2- 10-10 international system: includes 64 electrodes..

(18) 10-20 international system of electrode placement. electrode placement system, where Fp is Prefrontal, F is Frontal, C is Central, T is Temporal, P is Parietal, O is Occipital, A is Ear..

(19)

(20) 10-10 international system of electrode placement.

(21) Basic Differential Amplifier Differential amplifiers measure the voltage difference between the two signals at each of its inputs..

(22) Electrode Montages ¾ The pattern of connections between the electrodes and the recording channels is known as a montage. ¾ There are two basic types of EEG montage: 1- Referential: The potential difference is measured between an active electrode and an inactive reference electrode..

(23) 2- Bipolar: The potential difference is measured between two active electrodes..

(24) Four EEG channels of bipolar montage 500. F8-C4. Amplitude (microvolt). 0 -500 0. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 500 F7-C3 0 -500 0. 1. 2. 3. 4. 5. 6. 7. 8. 500. 9. 10. T6-O2. 0 -500 0. 1. 2. 3. 4. 5. 6. 7. 8. 500. 9. 10. T5-O1. 0 -500 0. 1. 2. 3. 4. 5 6 Time (sec). 7. 8. 9. 10.

(25) Filter FOURIER THEOREM Any wave can be thought of (decomposed) as a number of sinusoidal waveforms that vary in amplitude, frequency and phase.. +.

(26) Filter.

(27) Function of a filter Filtering is the operation that results in zero amplitude for the waves at frequencies that we don't want to contribute to our final waveform..

(28) Low Pass Filter.

(29) High Pass Filter.

(30) Band - Pass Filter.

(31) Notch filter. 100 Percent Amplitude. A band pass filter around the power lines frequency (50 or 60 Hz).. 80 60 40 20 0. 20. 40. 60. Frequency (Hz).

(32) Types of FILTERS • Analog :. A piece of hardware, a resistor and a capacitor coupled together. ƒ Is applied before the analog-to-digital conversion. ƒ ON-LINE. • Digital:. A software algorithm.. ƒ Is applied after the analog-to-digital conversion. ƒ OFF-LINE.

(33)

(34)

References

Related documents

Contract type Antecedents Scope of content Effect on commitment Consequences of violation Emphasized fairness type Transactional Boundaryless career –mindset,

Glass tubes with an outside diameter range from 100 mm up to 400 mm possible (depending on wall thickness and length).. Lengths from 100 mm up to 1,700 mm are possible (depending

Technology companies are aggressively entering the market, investing in analytics, optimization and digital advertising solutions for the enterprise Technology companies

Nowlin was also an instructor in conducting and band scoring at Bowling Green State University and has served as a staff arranger for the Kansas State University Marching Band as

Analysis of the volumes traded on the Irish Stock Exchange present no dramatic increases apart from the period prior to the European financial crisis, with financials showing the

Part of the mechanism of action in endothelial cells is through decreased expression or release of a number of autocrine angiogenic factors, part is by interference with signaling

The purpose of this paper is to recommend that the Business Mobility Group endorse the attached Multilateral Framework (MLF) which will be the basis for APEC economies to

Table 1: Top Drivers for Contract Management Initiatives ...1 Table 2: The Impact of Poor Contract Management within the Enterprise...3 Table 3: Challenges around Contract