• No results found

4000 WIRELESS PROFINET

N/A
N/A
Protected

Academic year: 2021

Share "4000 WIRELESS PROFINET"

Copied!
11
0
0

Loading.... (view fulltext now)

Full text

(1)

4000

WIRELESS PROFINET

(2)

Substitute of conductor lines

Substitute of trailing cables and cable chains Substitute of optical data transceivers Crane systems

Warehouse systems Automotive industry Transport vehicles

Water, wastewater, waste and raw material management Engineering

Lifts, inclined lifts and cable cars Oil and gas industry

Steel and cement plants Stage technology o o o o o o o o o o o o o

Your benefits

WIRELESS PROFINET - DATAEAGLE 4000

The DATAEAGLE 4000 series was particularly designed for transparent data transmission of PROFINET IO using various radio technologies. All devices featuring a PROFINET IO interface may be connected via radio. Our patented filter technology guarantees a highly available and reliable radio connection. Read our white paper „Wireless 101“ to learn more about our patented wireless technology.

o o o o o

Patented filter technology PROFINET IO interface PROFIsafe

Plug and Play – no device configuration required up to 3000 meter range

Versatile

APPLICATION EXAMPLES

We have been successfully equipping industrial plants with our radio data transmission system for over 35 years. On our website you will find numerous practical examples and an overview of our

(3)

Differences at a glance

WIRELESS PROFINET - DATAEAGLE 4000

Profisafe Max. Radio Slaves Max. PROFIBUS Slaves Schutzart Reichweite

WIRELESS PROFINET - DATAEAGLE 4000

300 m 300 m 300 m 300 m 300 m 300 m 3000 m 3000 m Yes Yes No No No No No No 4 4 4 4 1 1 4 4 2,4 GHz 2,4 GHz 2,4 GHz 2,4 GHz 2,4 GHz 2,4 GHz 869 MHz 915 MHz 869 MHz 915 MHz 6 6 6 6 4 4 6 6 IP20 IP65 IP20 IP65 IP20 IP65 IP20 IP65 Typical Distance Frequency

Product Max. Radio Slaves Max. PROFINET Devices Protection class PROFIsafe Compact 4712 X-treme 4712 Compact 4713 X-treme 4713 Compact 4715 X-treme 4715 Compact 4333 Compact 4343 X-treme 4333 X-treme 4343

(4)

Technical data

24 V DC Terminal clamps 150 mA

DIN rail mounting IP20 -20…+60 °C CE, FCC 130 g 22,5 mm 99 mm 114,5 mm Black 2,4 GHz Bluetooth 100 mW (EIRP) 4 100 m 300 m

SMA Connection - 50 Ohm

100 Mbit Yes RJ 45 6 Yes 11174 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER

DATAEAGLE COMPACT 4712

o o o o

(5)

Technical data

24 V DC M12, A-coded 150 mA

4-hole screw fastening IP65 -20…+60 °C CE, FCC 280 g 88 mm 120 mm 42 mm Black 2,4 GHz Bluetooth 100 mW (EIRP) 4 100 m 300 m

SMA Connection - 50 Ohm

100 Mbit No M12, D-coded 6 Yes 11422 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER

DATAEAGLE X-TREME 4712

5 o o o o

WIRELESS PROFINET - DATAEAGLE 4000

Here you find all informations about antennas and accessories o

(6)

Technical data

24 V DC Terminal clamps 150 mA

DIN rail mounting IP20 -20…+60 °C CE, FCC 130 g 22,5 mm 99 mm 114,5 mm Black 2,4 GHz Bluetooth 100 mW (EIRP) 4 100 m 300 m

SMA Connection - 50 Ohm

100 Mbit Yes RJ 45 6 No 11171 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER

DATAEAGLE COMPACT 4713

o o o o

(7)

Technical data

WIRELESS PROFINET - DATAEAGLE 4000

GENERAL

Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER

DATAEAGLE X-TREME 4713

o o o o 24 V DC M12 150 mA

4-hole screw fastening IP65 -20…+60 °C CE, FCC 280 g 88 mm 120 mm 42 mm Black 2,4 GHz Bluetooth 100 mW (EIRP) 4 100 m 300 m

SMA Connection - 50 Ohm

100 Mbit No M12, D-coded 6 No 11421 7 Here you find all informations about antennas and accessories

o

(8)

24 V DC Terminal clamps 150 mA

DIN rail mounting IP20 -20…+60 °C CE, FCC 130 g 22,5 mm 99 mm 114,5 mm Black 2,4 GHz Bluetooth 100 mW (EIRP) 1 100 m 300 m

SMA Connection - 50 Ohm

100 Mbit Yes RJ 45 4 No 11170 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER

DATAEAGLE COMPACT 4715

o o o o

Technical data

(9)

24 V DC M12 150 mA

4-hole screw fastening IP65 -20…+60 °C CE, FCC 280 g 88 mm 120 mm 42 mm Black 2,4 GHz Bluetooth 100 mW (EIRP) 1 100 m 300 m

SMA Connection - 50 Ohm

100 Mbit No M12, D-coded 4 No 11420 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER

DATAEAGLE X-TREME 4715

9 o o o o

Technical data

WIRELESS PROFINET - DATAEAGLE 4000

Here you find all informations about antennas and accessories o

(10)

24 V DC Terminal clamps 250 mA

DIN rail mounting IP20 -20…+60 °C CE (869 MHz), FCC (915MHz) 160 g 22,5 mm 99 mm 114,5 mm Black 869 MHz or 915 MHz 500 mW (EIRP) 4 300 m 1000 -3000 m

SMA Connection - 50 Ohm

100 Mbit Yes RJ 45 6 No 11144 11158 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER DATAEAGLE Compact 4333 (869 MHz) DATAEAGLE Compact 4343 (915 MHz)

DATAEAGLE COMPACT

4333 / 4343

o o o o

Technical data

(11)

24 V DC M12, A-coded 250 mA

4-hole screw fastening IP65 -20…+60 °C CE (869 MHz), FCC (915MHz) 300 g 88 mm 120 mm 42 mm Black 869 MHz or 915 MHz 500 mW (EIRP) 4 300 m 1000 - 3000 m

SMA Connection - 50 Ohm

100 Mbit No M12, D-coded 6 No 11372 11374 GENERAL Voltage supply

Connection Voltage supply Power consumption Fixing Protection class Temperature range Conformity Weight Width Height Depth Color RADIO TECHNOLOGY Frequency Transmitting power Max. Number radio slaves Range Indoor

Range Outdoor Antenna connection

INTERFACE

Max. PROFINET Transmission rate 2-fach Switch

PROFINET Connection

Max. Number PROFINET Devices PROFIsafe ORDER NUMBER DATAEAGLE X-treme 4333 (869 MHz) DATAEAGLE X-treme 4343 (915 MHz)

DATAEAGLE X-TREME

4333 / 4343

11 o o o o

Technical data

WIRELESS PROFINET - DATAEAGLE 4000

Here you find all informations about antennas and accessories o

References

Related documents

Liquid film properties such as viscosity and surface tension affect the liquid mass separation of a shear-driven liquid film at the sharp corner through changes in LAW forma- tion

You can also receive academic training to earn an Associate of Applied Science or Applied Technology at Clark College.. 2 years at Clark for cost savings, personal instruction

You’re working in a business environment and want to specialize in the football industry.. You’re passionate about football and want specialized education to devote

Businesses in the two districts differed in their perception of other issues, with West Devon businesses reporting that meeting wage demands was a significant issue whilst South

PROFIBUS & PROFINET NL PROFIBUS, PROFINET en IO-Link Fieldbus Decentralized peripherals Controller Communication HMI Engineering Sensor/Actuator Engineering Controller z. Fault

Head Station with ProfiTrace built in Repeater modules with optional ‘scope and redundancy PROFIBUS DP slave modules IO modules digital, relay, analogue etc PROFINET

IO Controller CPU, IO Devices Bus Coupler, Signal and function modules with diagnostic capability detect internal and external module errors and generate a diagnostic