TICS - Integrated Control Strategy
TICS - Total Integrated Control Strategy
Mid Range System
TICS - Integrated Control Strategy
Mid Range
System
TICS - Integrated Control Strategy
Sensor
Type
Application
Complete Integration
The system can interface with underfloor heating,
radiators and hot water to ensure ideal comfort
condition at minimum running cost
.
And
/Or
Digital (2 Ch)
Bus Network
UFH
Radiator
DHW
Bus Network
Bus Network
Star Network
And
/Or
Central
Control
4.3” Touch Screen cc245
7” Touch Screen cc200
Or
TICS Mid Range
Install controls without
the complicated wiring
Bead (2 Ch)
Bus Network
Plate (1 Ch)
Star Network
TICS - Integrated Control Strategy
Central Control:
The control’s design enables all
elements of the underfloor heating,
Radiators and hot water to be
managed centrally via a simple to
use Touch Screen Interface.
Energy Efficient:
Time and temperature control for each zone, combined with auto
optimisation capabilities, which automatically learns the thermal inertia of
each zone, including hot water hysteresis. This system results in high
comfort levels and impressive energy savings capabilities.
Reliability
All control devices are individually tested prior to despatch which
dramatically reduces failure rates and consequently improves on-site
product reliability.
User Friendly
Time, effort and expertise have been invested to develop an intuitive,
easy-to-use, touch screen interface which enables the end user centrally
control of the all elements of the system at the touch of a key.
TICS – Mid Range
Total Flexibility
At the console select
Zone Type
Select any Sensor Type
Underfloor Heating
Digital (2 Ch) Bus Network
Radiators
Bead (2 Ch) Bus Network
Hot Water
Plate (1 Ch) Star Network
Mix and match to suit your application
TICS - Integrated Control Strategy
TICS – Reliability
Reliability
All control devices are individually tested prior to despatch which dramatically
reduces failure rates and consequently improves on-site product reliability.
Extensive Diagnostics
Embedded diagnostic facilities quickly identify typical
installation and service issues.
Pump Exercising Routine
Ensure pumps are kept operational during periods of inactivity.
12v Operation
No Batteries - No Replacing, No Recurring Cost, No Leaking
No RF issues - 100% reliability
Health & Safety
Significantly reduces the amount of 220v cable installed thought out the building
All products are
CE approved
Reliability
TICS - Integrated Control Strategy
User Friendly
Time, effort and expertise have been invested to develop an intuitive,
easy-to-use, sensor and touch screen interface
Zone Labelling
Zone designations are clearly labelled.
View Room Settings
Enables the user to view and edit every zone setting.
Stop Facility
Ideal for rooms which are not in use.
Lockout
Disable zone sensor buttons.
TICS – Simple To Operate
Control at your
finger tips
Central Console
Touch Screen Console Simple user friendly icons
Room Sensors
TICS - Integrated Control Strategy
32 Zones individual Temperature & Scheduling
Individual time & temperature control of each zone.
Boost Heat
Take advantage of low cost energy tariff periods.
Hot Water Management
Time & Temperature, Hysteresis & Legionella Boost functions
Zone Settings
Set back Tracking – ensure heat-up time are not over stretched
TICS – Energy Efficient
Mid Range & Advance System – See Module Options
Outstanding
Energy efficient
TICS - Integrated Control Strategy
TICS – Comfort Features
Zone Temperature
Independent temperature control per zone
E.g. Bedrooms 20°C, Baby Bedroom 24°C.
Programmable Timer
Individual zone scheduling to homeowner
personal settings.
Hot Water Boost
HW boost activates the
DHW for 2 hours.
Optimisation
Optimisation is a mechanism that ensures zone temperatures are reached at the
scheduled times, including an automatic learning mode.
Frost Protection
TICS - Total Integrated Control Strategy
Touch Screen
4.3” - CC245
Central Control:
All elements of the heating, & hot water managed
Up to 32 zones
All rooms can be managed individually to reduce running costs.
Time & Temperature Control
Temp (SP/SB/BH) / Timer 7 day inc 4 x SP per day
Simple To operate
Typical user operations require one or two keystrokes.
Edit Zone Labeling
Zone label edit capability
4 Modes
All Off / All On / Manual / Timed.
Holiday
Select dates of an upcoming Holiday.
Sensor Lock Out
Ability to disable the use of room sensor button.
View Room Settings
View & edit each room setting./ View all zones status
Hot Water Boost
Scheduling / Boost / Hysteresis /Legionella Purge
Whole House Status
View status of all zones at a glance.
Optimization
4 Setting including an automatic learning mode.
TICS: Mid Range - Home Owner
Relay Board
R10i8s2
Sensor Options
Digital (2 Ch) (Bus)
Bead (2 Ch) (Bus)
Plate (1 Ch) (Star)
The control’s design enables all elements of the underfloor heating,
radiators and hot water to be managed centrally via a simple to use
TICS - Integrated Control Strategy
TICS: Mid Range - Integration
Console
Central Control of all elements (UFH / Rad / DHW)
Zoning
Individual Time & Temperature Control via
Discrete Plate Sensors or Digital Sensors
Hot Water
Time & Temperature Control via Cylinder Stat
Mechanical
Manage all Actuators /Valves /Pump/Boiler Demand.
Schedule
Schedule element such as Garden Sprinklers
TICS - Integrated Control Strategy
TICS: Time & Cycling
Relays Timers
Individually Assigned Time ON Delays (1-99 Min)
Individually Assigned Time Off –Overrun (1-99 Min)
Solves noise issues
Pump Exercising Routine
Assign Cycle Interval (Hrs) e.g. 336 (2 weeks)
Assign Cycle Duration (1-30 Min)
TICS - Integrated Control Strategy
TICS - Installation
Cabling – 1
st
Fix
1
stFix Cabling (Sensors)
All Low Voltage
Plates - Star (2 wire)
Digital - Bus (4 wire)
Cabling
Single cable bus network design reduces installation time
and costs. Reduce electrical cost approx 50%-60%
No Containment Duct or Conduits
TICS - Integrated Control Strategy
Install controls without the complicated wiring
2nd Fix Cabling (Mechanical)
Single Point wiring
Manage all Zone Valves, Pump & Boiler Demand.
Impressive M&E Savings
System manages interlock !!!
Time Delay & Pump Exercising
Configurable Time On Delay, Overrun & Pump Exercising
Simple
No on site complex wiring
No Phone Calls
Eliminate electrical phone calls
Traditional Controls
TICS Controls
TICS manages all interlocks !!!
TICS - Installation
Cabling – 2
nd
Fix
TICS - Integrated Control Strategy
TICS : Commissioning
Mid Range Configurable (R10i8 Board)
Tailored
Tailor the system to suit project requirements
Sensors:
Digital (2Ch)/ Bead (2Ch)/ Plate (1Ch)
Manage:
UFH/ Rad/ DHW/ Scheduled (Lights, sprinklers
etc)
Control:
All Pumps, Valve & Boiler Demands
Effortless Commissioning
Easy Drop-Down List Selection
Controls built to
suit a changing
world
Pump Aufh (All UFH zones)
Pump MF (Only UFH this MF)
Pump Ht (UFH & Rad)
Pump DHW (All DHW zone)
Pump Rad (All Rad zones)
Boiler (UFH/Rads/DHW)
TICS - Total Integrated Control Strategy
Touch Screen
4.3” - CC245
Remote Access
Broadband Router with Wifi Required (Hardware & Software)
DHW Priority
Automatically override heating zones
Basic Cooling (R8)
Override Boiler & active a single whole house cooling device
Extend Drop Down List
Extend Install Basic Installation / Commissioning Drop Down List
Input config - Modes
System Mode Inputs-Trigger Seasons & Master Modes)
Alarms
Via Inputs – Display -Front Screen
TICS: Mid Range - Optional Modules
Select which Module and System Options
suit your project requirements
Optional Modules
M
M
M
M
Touch Screen4.3” or 7” Options & 8/16/24/32 Zones
Sensors
Digital (2ch) (Bus )(Dual) /Bead (2ch) (Bus) (Dual) /Plate (1ch) (Star)
Screed
TICS - Total Integrated Control Strategy
Sample Layout 1
Equipment
4.3” Touch Screen
Digital Sensors
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
Bead Sensors
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
TICS - Total Integrated Control Strategy
Sample Layout 2
Equipment
4.3” Touch Screen
Plate Sensors
(1ch) (Air ) Star Wiring
TICS - Total Integrated Control Strategy
Sample Layout 3
Equipment
4.3” Touch Screen
Digital Sensors
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
Bead Sensors
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
Plate Sensor
(1ch) (Air )
Star Wiring
TICS - Total Integrated Control Strategy
Equipment
7” Touch Screen
Digital Sensors
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
Bead Sensors
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
Plate Sensor
(1ch) (Air & Screed Probe or Dual Zone) Star Wiring
DHW Probe
TICS - Integrated Control Strategy
TICS – 4.3” Touch Screen
CC245
Central Control:
The control’s design enables all elements of the heating, and hot water managed centrally via a simple to use Touch Screen Interface.
32 zones
All rooms can be managed individually to reduce running costs.
Temperature Control
Individual Set Point on each zone Set Point & Set Back
7 Day Programmable Timer
Individual Timer for each Zone.
Simple To operate
Typical user operations require one or two keystrokes.
Edit Zone Labeling
Zone label edit capability
4 Modes
All Off / All On / Manual / Timed.
Holiday
Select dates of an upcoming holidays.
Sensor Lock Out
Ability to disable the use of room sensor button.
View Room Settings
Enables the user to view and edit each room setting.
Hot Water Boost
The HW key turns the Immersion on for 2 hours. Hysteresis – Stop Boiler Cycling
Legionella – DHW 70 °C 1/2hr Scheduled Boost
Property Value
Excellent controls - property resale value increases.
Environment
Efficient Control Technology results in reduced gas emissions. that harm the environment.
Whole House Status
View status of all zones at a glance.
Copy Schedule
Helpful copy function between zones.
Edit Zone Labeling
Zone label edit capability
Optimization
4 Setting including an automatic learning mode.
Time change
Summer /Winter automatic change over.
Legibility
TICS - Integrated Control Strategy
TICS – Sensors Types/ Finishes
Digital – Slim Line
2 Channel
4 Wire
Bus Network
Colour: White
Model: CCT764WHI Colour: Brushed Stainless Steel Model: CCT764BSS Colour: Mirrored Chrome Model: CCT764MC
Bead Sensor
2 Channel
4 Wire
Bus Network
Colour: Legrand Special Model: CCB765 – Legrand
Plate Sensor 1 Channel 2 Wire
Star Network
Colour: Brushed Stainless Steel Model: CCB767BSS Colour: White (ABS)
Model: CCP767WHI)
Colour: Brushed Stainless Steel Model: CCB765BSS
Colour: Mirrored Chrome Model: CCB767MC Colour: Legrand Special
Model: CCB765 – Legrand
TICS - Integrated Control Strategy
TICS – Digital Sensor
CC764 Features
Zone Sensors
SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use.
BH - Boost heat Utilize low cost electricity.
7 day & 5/2 Programmable Timer *
Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C.
PI - Optimization*
Optimization is a mechanism of ensuring zone
temperatures are achieved according to the programmed schedule.
Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time.
Stop
Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back.
Lockout*
Solves the problem of children interfering with the room temp or thermostats located public areas.
Frost Protection Mode - Disable *
Ensure all plumbing is protected against frost.
Floor surface Protection *
Max floor temps setting, ensures floor surface are protected.
Min Screed Temp: Floor Surface Warming *
Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied.
Accuracy
Accuracy of 0.5° C
Screen
Screen: LCD Displays Actual & Set Point Temp Backlight : Blue Backlight with timeout.
Calibration
Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2
Central Override at the Console *
All sensor can be centrally overridden by the main console.
Centralized Clock
No need to enter date & time on each thermostat.
Installation
Simple to install, significantly reduce electrical costs.
12v Operation
Low voltage for Heath & Safety issues.
No Batteries—Eliminates dying & replacing old batteries No RF issues- 100% reliability.
Set Back Tracking
Ensure the Set Back always follows the Set Point.
Network
All sensors are network capable.
Dual Sensing channels
All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures.
Aux (Type 01)
Configurable Aux Channel
External / Flow / Retune / Ref Temp
Dual Zone (Type 02)
Single Digital sensor with Probe, can manage 2 zones
TICS - Integrated Control Strategy
TICS – Bead Sensor
CC765 Features
Zone Sensors
SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use.
BH - Boost heat Utilize low cost electricity.
7 day & 5/2 Programmable Timer *
Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C.
PI - Optimization*
Optimization is a mechanism of ensuring zone
temperatures are achieved according to the programmed schedule.
Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time.
Stop
Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back.
Frost Protection Mode - Disable *
Ensure all plumbing is protected against frost.
Floor surface Protection *
Max floor temps setting, ensures floor surface are protected.
Min Screed Temp: Floor Surface Warming *
Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied.
Accuracy
Accuracy of 0.5° C
Calibration
Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2
Central Override at the Console *
All sensor can be centrally overridden by the main console.
Centralized Clock
No need to enter date & time on each thermostat.
Installation
Simple to install, significantly reduce electrical costs.
12v Operation
Low voltage for Heath & Safety issues.
No Batteries—Eliminates dying & replacing old batteries No RF issues- 100% reliability.
Set Back Tracking
Ensure the Set Back always follows the Set Point.
Network
All sensors are network capable.
Dual Sensing channels
All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures.
Aux (Type 01)
Configurable Aux Channel
External / Flow / Retune / Ref Temp
Dual Zone (Type 02)
Single Digital sensor with Probe, can manage 2 zones
* Centrally set & control led at the console
Model: Colour:
TICS - Integrated Control Strategy
TICS Plate Sensor
CC767
Wiring2 Wire – Star Network
12v Operation
Low voltage for Heath & Safety issues.
No Batteries—Eliminates replacing old batteries No RF issues- 100% reliability.
Installation
Simple to install, significantly reduce electrical costs.
Accuracy
Accuracy of 1° C
Model: Colour:
CCP767WHI White (ABS) CCP767MC Mirrored Chrome CCP767BSS Brushed Stainless Steel
* Central control via the console
* Central Override at the Console *
All sensor can be centrally overridden by the main console.
* Zone Sensors
SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use.
BH – Boost heat Utilize low cost electricity.
* 7 day & 5/2 Programmable Timer *
Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C.
* PI - Optimization
Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time.
* Stop
Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back.
* Frost Protection Mode - Disable *
Ensure all plumbing is protected against frost.
* Set Back Tracking
Ensure the Set Back always follows the Set Point.
TICS - Integrated Control Strategy
OUTPUTS
Outputs (R10)8 x 230v Powered Outputs – Zones
1 x 230v Powered Outputs – Manifold Pump 1 x S/L Output –Boiler
(Switch live output can be jumpered to serve as a powered output)
Led indication
Each relay has a LED indicating the output status at a glance
Terminals
3 Connector terminals per relay.
(A single relay can activate up to 3 actuators)
Fuse Rate
Relay 1-5 (Qty 1) 4Amp Relay 6-8 & ufh pump (Qty 1) 4Amp Relay 6 Boiler (Qty 1) 4Amp
230v Input Supply (Qty 1) 1Amp Slow Blow
INPUTS
Inputs Temperature
Input 1-8
2 wire Temperature Input
Operate with temp probe OR mechanical cylinder stat Interface with Thimble or Plate Sensors
Switch Input Qty 2
Use with Optional Modules e.g. Back Boiler
SUPPLY Supply
Single 220v spur required at I/O Module Fuse Rating : 1Amp Slow Blow
BUS NETWORK
Network Terminal Bus network Connection ABGV
Network with Console & Digital Sensors Bus network Connection ABG
Network between I/O boards
Max Network Overall Cable length 1200meter
Addressing
Dip switch address
Up to 8 boards can be connected in a system Configurable:
Tailored to suit your project
SUMMARY
Reduce Electrical Installation Error & Cost
Centralised All connections in one location Reduce Wiring Single drop connect each device Powered Individually Powered Outputs Termination All connection via screw terminal Layout Clear & accessible layout Diagnostics View Comms Status