• No results found

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

N/A
N/A
Protected

Academic year: 2021

Share "TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System"

Copied!
25
0
0

Loading.... (view fulltext now)

Full text

(1)

TICS - Integrated Control Strategy

TICS - Total Integrated Control Strategy

Mid Range System

(2)

TICS - Integrated Control Strategy

Mid Range

System

(3)

TICS - Integrated Control Strategy

Sensor

Type

Application

Complete Integration

The system can interface with underfloor heating,

radiators and hot water to ensure ideal comfort

condition at minimum running cost

.

And

/Or

Digital (2 Ch)

Bus Network

UFH

Radiator

DHW

Bus Network

Bus Network

Star Network

And

/Or

Central

Control

4.3” Touch Screen cc245

7” Touch Screen cc200

Or

TICS Mid Range

Install controls without

the complicated wiring

Bead (2 Ch)

Bus Network

Plate (1 Ch)

Star Network

(4)

TICS - Integrated Control Strategy

Central Control:

The control’s design enables all

elements of the underfloor heating,

Radiators and hot water to be

managed centrally via a simple to

use Touch Screen Interface.

Energy Efficient:

Time and temperature control for each zone, combined with auto

optimisation capabilities, which automatically learns the thermal inertia of

each zone, including hot water hysteresis. This system results in high

comfort levels and impressive energy savings capabilities.

Reliability

All control devices are individually tested prior to despatch which

dramatically reduces failure rates and consequently improves on-site

product reliability.

User Friendly

Time, effort and expertise have been invested to develop an intuitive,

easy-to-use, touch screen interface which enables the end user centrally

control of the all elements of the system at the touch of a key.

TICS – Mid Range

Total Flexibility

At the console select

Zone Type

Select any Sensor Type

Underfloor Heating

Digital (2 Ch) Bus Network

Radiators

Bead (2 Ch) Bus Network

Hot Water

Plate (1 Ch) Star Network

Mix and match to suit your application

(5)

TICS - Integrated Control Strategy

TICS – Reliability

Reliability

All control devices are individually tested prior to despatch which dramatically

reduces failure rates and consequently improves on-site product reliability.

Extensive Diagnostics

Embedded diagnostic facilities quickly identify typical

installation and service issues.

Pump Exercising Routine

Ensure pumps are kept operational during periods of inactivity.

12v Operation

No Batteries - No Replacing, No Recurring Cost, No Leaking

No RF issues - 100% reliability

Health & Safety

Significantly reduces the amount of 220v cable installed thought out the building

All products are

CE approved

Reliability

(6)

TICS - Integrated Control Strategy

User Friendly

Time, effort and expertise have been invested to develop an intuitive,

easy-to-use, sensor and touch screen interface

Zone Labelling

Zone designations are clearly labelled.

View Room Settings

Enables the user to view and edit every zone setting.

Stop Facility

Ideal for rooms which are not in use.

Lockout

Disable zone sensor buttons.

TICS – Simple To Operate

Control at your

finger tips

Central Console

Touch Screen Console Simple user friendly icons

Room Sensors

(7)

TICS - Integrated Control Strategy

32 Zones individual Temperature & Scheduling

Individual time & temperature control of each zone.

Boost Heat

Take advantage of low cost energy tariff periods.

Hot Water Management

Time & Temperature, Hysteresis & Legionella Boost functions

Zone Settings

Set back Tracking – ensure heat-up time are not over stretched

TICS – Energy Efficient

Mid Range & Advance System – See Module Options

Outstanding

Energy efficient

(8)

TICS - Integrated Control Strategy

TICS – Comfort Features

Zone Temperature

Independent temperature control per zone

E.g. Bedrooms 20°C, Baby Bedroom 24°C.

Programmable Timer

Individual zone scheduling to homeowner

personal settings.

Hot Water Boost

HW boost activates the

DHW for 2 hours.

Optimisation

Optimisation is a mechanism that ensures zone temperatures are reached at the

scheduled times, including an automatic learning mode.

Frost Protection

(9)

TICS - Total Integrated Control Strategy

Touch Screen

4.3” - CC245

Central Control:

All elements of the heating, & hot water managed

Up to 32 zones

All rooms can be managed individually to reduce running costs.

Time & Temperature Control

Temp (SP/SB/BH) / Timer 7 day inc 4 x SP per day

Simple To operate

Typical user operations require one or two keystrokes.

Edit Zone Labeling

Zone label edit capability

4 Modes

All Off / All On / Manual / Timed.

Holiday

Select dates of an upcoming Holiday.

Sensor Lock Out

Ability to disable the use of room sensor button.

View Room Settings

View & edit each room setting./ View all zones status

Hot Water Boost

Scheduling / Boost / Hysteresis /Legionella Purge

Whole House Status

View status of all zones at a glance.

Optimization

4 Setting including an automatic learning mode.

TICS: Mid Range - Home Owner

Relay Board

R10i8s2

Sensor Options

Digital (2 Ch) (Bus)

Bead (2 Ch) (Bus)

Plate (1 Ch) (Star)

The control’s design enables all elements of the underfloor heating,

radiators and hot water to be managed centrally via a simple to use

(10)

TICS - Integrated Control Strategy

TICS: Mid Range - Integration

Console

Central Control of all elements (UFH / Rad / DHW)

Zoning

Individual Time & Temperature Control via

Discrete Plate Sensors or Digital Sensors

Hot Water

Time & Temperature Control via Cylinder Stat

Mechanical

Manage all Actuators /Valves /Pump/Boiler Demand.

Schedule

Schedule element such as Garden Sprinklers

(11)

TICS - Integrated Control Strategy

TICS: Time & Cycling

Relays Timers

Individually Assigned Time ON Delays (1-99 Min)

Individually Assigned Time Off –Overrun (1-99 Min)

Solves noise issues

Pump Exercising Routine

Assign Cycle Interval (Hrs) e.g. 336 (2 weeks)

Assign Cycle Duration (1-30 Min)

(12)

TICS - Integrated Control Strategy

TICS - Installation

Cabling – 1

st

Fix

1

st

Fix Cabling (Sensors)

All Low Voltage

Plates - Star (2 wire)

Digital - Bus (4 wire)

Cabling

Single cable bus network design reduces installation time

and costs. Reduce electrical cost approx 50%-60%

No Containment Duct or Conduits

(13)

TICS - Integrated Control Strategy

Install controls without the complicated wiring

2nd Fix Cabling (Mechanical)

Single Point wiring

Manage all Zone Valves, Pump & Boiler Demand.

Impressive M&E Savings

System manages interlock !!!

Time Delay & Pump Exercising

Configurable Time On Delay, Overrun & Pump Exercising

Simple

No on site complex wiring

No Phone Calls

Eliminate electrical phone calls

Traditional Controls

TICS Controls

TICS manages all interlocks !!!

TICS - Installation

Cabling – 2

nd

Fix

(14)

TICS - Integrated Control Strategy

TICS : Commissioning

Mid Range Configurable (R10i8 Board)

Tailored

Tailor the system to suit project requirements

Sensors:

Digital (2Ch)/ Bead (2Ch)/ Plate (1Ch)

Manage:

UFH/ Rad/ DHW/ Scheduled (Lights, sprinklers

etc)

Control:

All Pumps, Valve & Boiler Demands

Effortless Commissioning

Easy Drop-Down List Selection

Controls built to

suit a changing

world

Pump Aufh (All UFH zones)

Pump MF (Only UFH this MF)

Pump Ht (UFH & Rad)

Pump DHW (All DHW zone)

Pump Rad (All Rad zones)

Boiler (UFH/Rads/DHW)

(15)

TICS - Total Integrated Control Strategy

Touch Screen

4.3” - CC245

Remote Access

Broadband Router with Wifi Required (Hardware & Software)

DHW Priority

Automatically override heating zones

Basic Cooling (R8)

Override Boiler & active a single whole house cooling device

Extend Drop Down List

Extend Install Basic Installation / Commissioning Drop Down List

Input config - Modes

System Mode Inputs-Trigger Seasons & Master Modes)

Alarms

Via Inputs – Display -Front Screen

TICS: Mid Range - Optional Modules

Select which Module and System Options

suit your project requirements

Optional Modules

M

M

M

M

Touch Screen

4.3” or 7” Options & 8/16/24/32 Zones

Sensors

Digital (2ch) (Bus )(Dual) /Bead (2ch) (Bus) (Dual) /Plate (1ch) (Star)

Screed

(16)

TICS - Total Integrated Control Strategy

Sample Layout 1

Equipment

4.3” Touch Screen

Digital Sensors

(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring

Bead Sensors

(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring

(17)

TICS - Total Integrated Control Strategy

Sample Layout 2

Equipment

4.3” Touch Screen

Plate Sensors

(1ch) (Air ) Star Wiring

(18)

TICS - Total Integrated Control Strategy

Sample Layout 3

Equipment

4.3” Touch Screen

Digital Sensors

(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring

Bead Sensors

(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring

Plate Sensor

(1ch) (Air )

Star Wiring

(19)

TICS - Total Integrated Control Strategy

Equipment

7” Touch Screen

Digital Sensors

(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring

Bead Sensors

(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring

Plate Sensor

(1ch) (Air & Screed Probe or Dual Zone) Star Wiring

DHW Probe

(20)

TICS - Integrated Control Strategy

TICS – 4.3” Touch Screen

CC245

Central Control:

The control’s design enables all elements of the heating, and hot water managed centrally via a simple to use Touch Screen Interface.

32 zones

All rooms can be managed individually to reduce running costs.

Temperature Control

Individual Set Point on each zone Set Point & Set Back

7 Day Programmable Timer

Individual Timer for each Zone.

Simple To operate

Typical user operations require one or two keystrokes.

Edit Zone Labeling

Zone label edit capability

4 Modes

All Off / All On / Manual / Timed.

Holiday

Select dates of an upcoming holidays.

Sensor Lock Out

Ability to disable the use of room sensor button.

View Room Settings

Enables the user to view and edit each room setting.

Hot Water Boost

The HW key turns the Immersion on for 2 hours. Hysteresis – Stop Boiler Cycling

Legionella – DHW 70 °C 1/2hr Scheduled Boost

Property Value

Excellent controls - property resale value increases.

Environment

Efficient Control Technology results in reduced gas emissions. that harm the environment.

Whole House Status

View status of all zones at a glance.

Copy Schedule

Helpful copy function between zones.

Edit Zone Labeling

Zone label edit capability

Optimization

4 Setting including an automatic learning mode.

Time change

Summer /Winter automatic change over.

Legibility

(21)

TICS - Integrated Control Strategy

TICS – Sensors Types/ Finishes

Digital – Slim Line

2 Channel

4 Wire

Bus Network

Colour: White

Model: CCT764WHI Colour: Brushed Stainless Steel Model: CCT764BSS Colour: Mirrored Chrome Model: CCT764MC

Bead Sensor

2 Channel

4 Wire

Bus Network

Colour: Legrand Special Model: CCB765 – Legrand

Plate Sensor 1 Channel 2 Wire

Star Network

Colour: Brushed Stainless Steel Model: CCB767BSS Colour: White (ABS)

Model: CCP767WHI)

Colour: Brushed Stainless Steel Model: CCB765BSS

Colour: Mirrored Chrome Model: CCB767MC Colour: Legrand Special

Model: CCB765 – Legrand

(22)

TICS - Integrated Control Strategy

TICS – Digital Sensor

CC764 Features

Zone Sensors

SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use.

BH - Boost heat Utilize low cost electricity.

7 day & 5/2 Programmable Timer *

Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C.

PI - Optimization*

Optimization is a mechanism of ensuring zone

temperatures are achieved according to the programmed schedule.

Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time.

Stop

Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back.

Lockout*

Solves the problem of children interfering with the room temp or thermostats located public areas.

Frost Protection Mode - Disable *

Ensure all plumbing is protected against frost.

Floor surface Protection *

Max floor temps setting, ensures floor surface are protected.

Min Screed Temp: Floor Surface Warming *

Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied.

Accuracy

Accuracy of 0.5° C

Screen

Screen: LCD Displays Actual & Set Point Temp Backlight : Blue Backlight with timeout.

Calibration

Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2

Central Override at the Console *

All sensor can be centrally overridden by the main console.

Centralized Clock

No need to enter date & time on each thermostat.

Installation

Simple to install, significantly reduce electrical costs.

12v Operation

Low voltage for Heath & Safety issues.

No Batteries—Eliminates dying & replacing old batteries No RF issues- 100% reliability.

Set Back Tracking

Ensure the Set Back always follows the Set Point.

Network

All sensors are network capable.

Dual Sensing channels

All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures.

Aux (Type 01)

Configurable Aux Channel

External / Flow / Retune / Ref Temp

Dual Zone (Type 02)

Single Digital sensor with Probe, can manage 2 zones

(23)

TICS - Integrated Control Strategy

TICS – Bead Sensor

CC765 Features

Zone Sensors

SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use.

BH - Boost heat Utilize low cost electricity.

7 day & 5/2 Programmable Timer *

Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C.

PI - Optimization*

Optimization is a mechanism of ensuring zone

temperatures are achieved according to the programmed schedule.

Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time.

Stop

Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back.

Frost Protection Mode - Disable *

Ensure all plumbing is protected against frost.

Floor surface Protection *

Max floor temps setting, ensures floor surface are protected.

Min Screed Temp: Floor Surface Warming *

Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied.

Accuracy

Accuracy of 0.5° C

Calibration

Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2

Central Override at the Console *

All sensor can be centrally overridden by the main console.

Centralized Clock

No need to enter date & time on each thermostat.

Installation

Simple to install, significantly reduce electrical costs.

12v Operation

Low voltage for Heath & Safety issues.

No Batteries—Eliminates dying & replacing old batteries No RF issues- 100% reliability.

Set Back Tracking

Ensure the Set Back always follows the Set Point.

Network

All sensors are network capable.

Dual Sensing channels

All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures.

Aux (Type 01)

Configurable Aux Channel

External / Flow / Retune / Ref Temp

Dual Zone (Type 02)

Single Digital sensor with Probe, can manage 2 zones

* Centrally set & control led at the console

Model: Colour:

(24)

TICS - Integrated Control Strategy

TICS Plate Sensor

CC767

Wiring

2 Wire – Star Network

12v Operation

Low voltage for Heath & Safety issues.

No Batteries—Eliminates replacing old batteries No RF issues- 100% reliability.

Installation

Simple to install, significantly reduce electrical costs.

Accuracy

Accuracy of 1° C

Model: Colour:

CCP767WHI White (ABS) CCP767MC Mirrored Chrome CCP767BSS Brushed Stainless Steel

* Central control via the console

* Central Override at the Console *

All sensor can be centrally overridden by the main console.

* Zone Sensors

SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use.

BH – Boost heat Utilize low cost electricity.

* 7 day & 5/2 Programmable Timer *

Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C.

* PI - Optimization

Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time.

* Stop

Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back.

* Frost Protection Mode - Disable *

Ensure all plumbing is protected against frost.

* Set Back Tracking

Ensure the Set Back always follows the Set Point.

(25)

TICS - Integrated Control Strategy

OUTPUTS

Outputs (R10)

8 x 230v Powered Outputs – Zones

1 x 230v Powered Outputs – Manifold Pump 1 x S/L Output –Boiler

(Switch live output can be jumpered to serve as a powered output)

Led indication

Each relay has a LED indicating the output status at a glance

Terminals

3 Connector terminals per relay.

(A single relay can activate up to 3 actuators)

Fuse Rate

Relay 1-5 (Qty 1) 4Amp Relay 6-8 & ufh pump (Qty 1) 4Amp Relay 6 Boiler (Qty 1) 4Amp

230v Input Supply (Qty 1) 1Amp Slow Blow

INPUTS

Inputs Temperature

Input 1-8

2 wire Temperature Input

Operate with temp probe OR mechanical cylinder stat Interface with Thimble or Plate Sensors

 Switch Input Qty 2

Use with Optional Modules e.g. Back Boiler

SUPPLY Supply

Single 220v spur required at I/O Module Fuse Rating : 1Amp Slow Blow

BUS NETWORK

Network Terminal

 Bus network Connection ABGV

Network with Console & Digital Sensors  Bus network Connection ABG

Network between I/O boards

 Max Network Overall Cable length 1200meter

Addressing

Dip switch address

Up to 8 boards can be connected in a system  Configurable:

Tailored to suit your project

SUMMARY

Reduce Electrical Installation Error & Cost

Centralised All connections in one location Reduce Wiring Single drop connect each device Powered Individually Powered Outputs Termination All connection via screw terminal Layout Clear & accessible layout Diagnostics View Comms Status

TICS Wiring Centre I/O

References

Related documents

This essay asserts that to effectively degrade and ultimately destroy the Islamic State of Iraq and Syria (ISIS), and to topple the Bashar al-Assad’s regime, the international

Making sacramental wine requires special attention and care, starting with qvevri washing and marani hygiene and ending with fermentation, aging and storage. During

This ELR- based approach is used in this study to produce weekly and week-3–4 multimodel ensemble (MME) precipitation tercile probabilities forecasts from three individual

This conclusion is further supported by the following observations: (i) constitutive expression of stdE and stdF in a Dam + background represses SPI-1 expression (Figure 5); (ii)

Ecce Dedi Verbum Mea (composed 2010) for DV A Cappella Choir. Commissioned by the Riverside College Chamber Singers, Riverside, CA, John Byun, director of choral activities.

Project Management, Configuration Services, Deployment Services, Asset Tagging, Apple One-to-One Services Solution, Remote Consulting, and Full-Time Resources are custom

This paper examines the closed economy effects of government policies that vary with respect to whether they treat newly produced capital differently from old capital. Policies that

public void mouseClicked(MouseEvent e) { // Custom components need to request the // input focus when they are clicked,}. // otherwise they won't receive keyboard events