4 foot or less, linear or u-bends
1- to 2-lamp, low ballast factor
(≤.85) $15
1- to 2-lamp, normal or high ballast
factor (>.85) $5
3- to 4-lamp, low ballast factor
(≤.85) $34
3- to 4-lamp, normal or high ballast
factor (>.85) $26
5 to 8 foot
1- to 2-lamp, low ballast factor
(≤.85) $13
1- to 2-lamp, normal or high ballast
factor (>.85) $11
8 foot to 4 foot
Two 4-foot T8 fluorescents, any
ballast factor $34
Retrofit 2-lamp 8 foot T12 fixture with two 4-foot T8 fixture (delamping). Must permanently remove one set of sockets.
Four 4-foot T8 fluorescents, low
ballast factor (≤.85) $27 Retrofit 2-lamp 8 foot T12 fixture with four 4-foot T8s.
2x2 u-bend 2-3 linear lamp, any ballast factor $24
Retrofit 2x2 u-bend T12 magnetic ballast fixture with 2x2 17-watt T8 linear fluorescents. 2 or 3 17-watt T8 allowed. High efficiency electronic ballasts required. No 700 series T8s allowed.
T8 to T8
1- to 4-lamp, low ballast factor
(≤.85) $6
Retrofit standard or magnetic ballast 32-watt T8 fixture with high efficiency electronic ballast with 28-watt or less T8. No 700 series T8s allowed.
4 foot, 28-watt or less per lamp rebate $1 Install 28-watt or less T8 lamps instead of 32-watt T8 lamp.
All 4 foot lamps and ballasts must be on Consortium for Energy Efficiency list. No 700 series T8s rebated.
Fluorescent T8 Fixtures with High Efficiency Electronic Ballasts Replacing T12 Fluorescent with Magnetic Ballast -- Rebate per fixture
Low-Wattage Fluorescent T8 Lamps
One for one lamp retrofit. For example, retrofitting 2-lamp T12 fixture with 2-lamp T8 fixture.
One for one lamp retrofit. High efficiency electronic ballast required. No 700 series T8s allowed.
T12 to T8 - Install 1- to 2-lamp T8,
any ballast factor $47
T12 to T8 - Install 3-lamp, any
ballast factor $37
Delamping only $4
Reflector kits must be installed in conjunction with delamping and must be ≥90% reflectivity. Rebate is per fixture.
1- to 2-lamp $16 Retrofit 4-foot T12 fixture with T5 fluorescent and electronic ballast.
LED or LEC Exit Signs
Replace incandescent with LED or
LEC Exit Sign $25
LED or LEC Exit Signs
Replace fluorescent > 15 watts with
LED or LEC Exit Sign $14
5 watt or less $11
Greater than 5 watt to 10 watt $15
Greater than 10 watt to 20 watt $26
Reflector Kits
LED Lamps
Fluorescent T5 Fixtures with Electronic Ballasts Replacing T12 Fluorescent with Magnetic Ballast -- Rebate per fixture
Replace incandescent or halogen lamps with Energy Star qualified LED lamps
Must be Energy Star qualified or listed on Lighting Facts. Finding qualifying LEDs at
http://www.energystar.gov/index.cfm?c=manuf_res.pt_lighting http://www.lightingfacts.com/content/products
Must replace entire exit sign. Delamping
Rebate based on permanent removal of lamps, ballasts, and sockets in the fixture. For example, retrofitting 4-lamp T12 to 2-lamp T8. Reducing quantity of fixtures does not qualify. Ballast AND lamps must be on Consortium for Energy Efficiency list. May take reflector kit and low-wattage T8 rebate.
25 watt or less
Replace incandescent or halogen
lamps with LED $32
Must be Energy Star qualified or listed on Lighting Facts (see websites above). Must be rated for commercial use.
25 watt
Replace 65 watt or greater incandescent or halogen with
integrated ceramic metal halide. $17
25 watt Integrated ceramic metal halides only.
Photocell for Exterior Fixtures
No controls or non-working
photocell $30
Wall Occupancy Sensor No Controls $20
Daylighting, Ceiling or Fixture
Sensor No Controls $30
EC Motors Replace shaded pole motors
$90 walk-in
$50 display Must be installed in refrigeration or freezer applications only
Anti-sweat Heater Controls No controls $90
Rebate is per door. Must install a controller that reduces the energy use of anti-sweat heater by 50% by sensing humidity, dew point or condensation. Rebate only applies to adding ASH controls to existing or new display cases and existing walk-in or warehouse coolers/freezers doors. No rebate is available for NEW walk-in/warehouse.
Permanently Installed Lighting Controls
Must be permanently installed. Lighting controls may be wall-, fixture-, or ceiling-mounted, passive infrared, ultrasonic, wireless, or dual technology sensors.
Refrigeration
Interior LED Recessed Luminaires
ECM Fan Controls No controls $40
Rebate is per fan motor. Must control 4 fans or more. Evaporator fan control systems must turn off evaporator fans at least 70% of the time the compressor is not running. Must reduce the airflow of evaporator fans in walk-in coolers when compressor(s) cycles off while no refrigerant flows through the evaporator, and must control a minimum fan load of 1/20 horsepower when the fan(s) operate continuously at full speed. Rebate only applies to existing or new display cases and existing walk-in or warehouse coolers/freezers doors. No rebate is available for NEW walk-in/warehouse.
LED Case Lighting
Replace T12, T10, or T8 fluorescent
case lighting $65
Rebate is per LED light strip/tube. Must be Design Lights Consortium listed. Find qualifying equipment at:
http://www.designlights.org/solidstate.about.QualifiedProductsList_Public v2.php
LED Case Occupancy Control No controls $10 Rebate is per LED controlled.
Night Covers - Vertical or Horizontal No covers $6.50 Rebate is per linear feet. Night covers must be used when store is closed.
Variable Frequency Drive (VFD) Constant speed motor with no VFD $100
Rebate per horsepower (hp). 1 - 100 hp only. Equipment over 100 hp will be evaluated via custom efficiency application. VFD must operate a minimum of 2,000 hours per year to be eligible for rebate.
Engine Block Heater Timer No timer $10
Must be programmable timer. Holy Cross recommends using engine block heater just 2-4 hours before using vehicle. Be sure the timer is (1) a heavy duty, outdoor timer; (2) cold weather resistant; and (3) rated for 15 Amps (1800 watts) capacity.
Programmable Thermostat
(gas heat) Non-programmable thermostat $20
Participants in this program are encouraged to properly dispose of old thermostats containing mercury. Thermostats can be recycled at Charles D Jones in Glenwood or your county household hazardous waste facility. Programmable Thermostat
(electric heat) Non-programmable thermostat $50
All electric account only; Participants in this program are encouraged to properly dispose of old thermostats containing mercury. Thermostats can be recycled at Charles D Jones in Glenwood or your county household hazardous waste facility.
1. Rebates are subject to change and/or discontinuation without notice. Funding is limited. Applications will be accepted on a first come, first served basis. 2. Rebates are for existing commercial spaces. All measures must be installed within Holy Cross territory.
3. New construction or major renovations will be considered under custom efficiency program. 4. Rebate checks will be sent 4-6 weeks after receiving completed rebate application.
5. Holy Cross Energy reserves the right to inspect the installation premises.
7. Holy Cross Energy is not liable or responsible for any act or omission of any party, consumer, or contractor whatsoever.
8. Rebate amount cannot exceed 50% of total project cost (material, labor, recycling fee -- no tax, shippping, or permit fees included in total costs). 9. Invoices and/or receipts for purchases and work performed must be furnished.
10. Rebate application and associated invoices/receipts must be received no later than 180 days from date of applicable invoices/receipts. 11. Consumer(s) of record must have an active electric account in good standing with Holy Cross Energy.
12. Commercial rebates are limited to $50,000 per year per member.
13. Itemized invoices showing manufacturer and model number of all equipment is required.
13. Ballasts, fluorescents, and other mercury containing lamps must be recycled and proof of recycling must accompany invoice.
Contact Mary Wiener at 970-947-5432 or [email protected] for more information or to submit proposal for rebates over $5,000 or custom projects.