(1)CUMMINS DIESEL GENERATOR SET. WWW.V-FLO.COM.

(2) CUMMINS DIESEL GENERATOR SET 50HZ 33kVA—-550kVA > Description of products: ———Intelligent PCC2100/1301 control system 1.Generator sets of basic characteristic ◆ Low cost, high efficiency, compact structure, environment friendly. ◆ Heavy load durable, four-stroke, water cooled engine. ◆ Excellent transient response. ②STAMFORD Alternator ◆Brushless, four-pole revolving field, single bearing and drop proof screen protected. ◆Class H insulation ◆IP21-IP23 protection standard ◆Super short-circuit the affordability ◆Nonlinear distortion small load voltage waveform ③PCC digital control system The highly integrated control system: ◆Micro-processor control module. ◆To achieve the best reliable operation of generating units ◆Integrated engine speed and voltage regulator function ◆Comply with RFI/EMI standard and surge testing specification Units monitoring and alarm functions: ◆Monitoring engine and generator running ◆Self-diagnosis system function ◆Real-time display engine and generator operating parameters ◆system real–time warning Battery monitoring system: ◆Generators each time you start, monitor battery capacity ◆Weak battery warning ◆Battery high/low voltage alarm Interface ◆Equipped with communication interface ④Integrity of the supporting equipment Generating units installed built-in shock absorber, control system, starting system and others Base ◆ Built-in shock absorption pad used rubber materials ◆Does not require the installation of shock absorption pad for the base and connect with the foundations of fixed Cooling ◆50 ℃ ambient temperature design. WWW.V-FLO.COM. WWW.V-FLO.COM. ①CUMMINS DIESEL ENGINE.

(3) ①Voltage regulator rate The following cases voltage regulator in the rate of less than ±0.5%-±1% ◆Power factor 0.8(logging)-1.0 ◆From the no-load to full load, and in any load condition stable operation ◆From the cooler to the heat engine ◆Speed drop(%)<4.5 ②Frequency regulator rate From the no-load to full load, the frequency of synchronized ③Random frequency fluctuation From the no-load to full load, and in any load condition stable operation, maximum ±0.25% ④Voltage waveform ◆Open circuit, the maximum wave of distortion is 1.5% ◆3 equilibrium load, the maximum wave of distortion is 5.0% ⑤Telephone impact factor (TIF) Less than 50 ⑥Telephone harmonious factor (THF) Less than 2%,comply with BS4999 section 40 standard ⑦Electromagnetic effects Comply with BS800 standard, VDE standard between class G and N. 3. Engine performance parameters ①Type: CUMMINS 4B, 4lsBe, 6B, 6tsBe, 6C, QSL9, NTA855, QSX15, KTA19 series engine ②Structure: forged steel crankshaft. Cast-iron cylinder and wet cylinder , each cylinder 2/4 valve ③Starting system: ◆12VDC/24VDC starting battery, 30A-65A battery charger ◆At 0℃ ,current is 550A-640A ④Intake: ◆Turbocharged ◆Free air intake ◆Water/air intercooler turbocharged ⑤Fuel system ◆12VDC/24VDC safe isolate valve, dual spin-on paper element fuel filter, gensets equipped with dual flexible fuel union pipe. ◆DI/EFI system ⑥Filter system ◆Gas into the dry-core resistance indicator air filter ◆Spin-on paper element oil filter with full-flow and bypass ◆Rotary with anti corrosion water filter. 4. Synchronous Generator performance parameters ①Type: ◆brushless, four-pole revolving field, single bearing and drop proof screen protected. ◆Class H insulation ◆IP22( or NEMA 1) protection standard ◆IC 01 cooling system ◆AC exciter, rectifier unit rotation ◆Stator windings by the vacuum pressure impregnation with moisture-proof surface covering epoxy insulator. WWW.V-FLO.COM. WWW.V-FLO.COM. 2. Generator sets performance parameters:.

(4) ◆Through high temperature insulation resin paint handling exciter and rotor are more applicable to the use of harsh environment. ◆Dynamically balanced rotor to BS5625 grade 2.5 ◆High-quality lubrication sealed for long-life bearing ◆Rotor silicon steel sheet machinery sealing. ①Base ◆Special welding base, built-in shock absorber ◆Lifting overall ◆Dual-flexible rubber fuel pipe, base frame tank with level gage, the sewage plug ②Surface decoration Emerald green special coating, Bright durable, wear-resistant ③Documents with delivery Installation and maintenance manual, operation manual. 6. Generator sets optional assembly ①Engine ◆With heavy resistance indicator of the air filter ◆Oil pump emissions ◆240V cooling water heater( temp. control) ◆Exhaust gas temperature indicator ②Fuel system ◆Discrete type 450L, 900L fuel tank ◆Electrical control fuel delivery system ◆High level/low oil alarm or shut-down protection ◆Manual delivery oil pump ③Generator ◆Anti-condensation heater ◆105℃ temperature rise generator ④Exhaust system ◆Exhaust silencers (homely) ◆Bellows ◆Exhaust pipe elbow ⑤Others 5A.10A auto–charger Standards: ISO3046 ISO8528 UTE5100 BS5514. VDE0530. BS4999 BS5000pt99 CAS A22.2. AS359 CEMA. > Control system PCC2100 1. AmpSentry TM Protection function ①Cummins’s patented products ②Over current alarm/shut down ③High/Low AC voltage shutdown ④Low frequency shutdown ⑤Over frequency shutdown/alarm ⑥Overload alarm. ⑦Reverse power shutdown ⑧Inverse reactive shutdown ⑨Sensor signal loss shutdown. IEC34 NEMA MG1-22. WWW.V-FLO.COM. WWW.V-FLO.COM. 5. Other functions.

(5) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●. Digital control engine speed Digital voltage regulation AmpSentry TM protection Analog and digital AC output instrument display Battery weak monitoring system Digital alarm and state information display Generator sets monitoring function Self-diagnosis system function Communication network Advanced PC software application services capabilities Remote auto starting up Control the number of units launched Digital display output Voltage, Current phase of the selection keys “Operating-shutdown-auto” knobs switches Urgent shutting off control Custom interface box Disk background lights Reset button Unified global network of services. 3. Parameter Indication ● ● ● ● ● ● ● ● ● ● ● ● ● ●. Generator sets parameter Starting/operating data record Generator sets output voltage Generator sets output current Generator sets output frequency Generator sets output power Generator sets output electricity Battery voltage Engine lube oil pressure Engine cool water temperature System Data display Adjustment of historical data Failure historical data Load parameter. 4. Internal control function ①Engine control ● Remote start mode ● Sleep mode ● Data record ● Failure analog mode ● Engine starting ● Turning circle ● Delayed start-up and shutdown ②Engine regulation speed ● Speed sync function ● With the temperature adjustment ● Smart idling mode ③Alternator control ● Digital output voltage adjustment rate ● Torque match voltage overload control ● Fault current adjustment. 5. Standard protection function ①Generator sets protection. WWW.V-FLO.COM. WWW.V-FLO.COM. 2. Standard Control Function.

(6) Fault alarm Urgent shutting off Programmable alarm and state input ②Engine protection ● Over-speed protection ● Lube low pressure alarm/shutdown ● High water temperature alarm/shutdown ● Low level water alarm/shutdown ● Starting /Turning failure ● Turning locking ● Sensor fault display ● Low/high battery voltage alarm ● Leak battery /fault alarm ● Starter not connected. 6. EMC Standard PCC2100 control system in line with EMC international standard. ①Communication interface ● Equipped with RS232 communication interface. ● Supported Cummins GOAL agreement. ● Customer monitoring system can be used to obtain data . ● Cummins services can also be used for monitoring software or software INPOWER ②Standard: NFPA110-1 EN50081-1 UL508 EN50081-2 CSA C282-M1999 EN50082-1 CSA 22.2-14 EN50082-2 ISO 8528-4;1993 MIL STD 202C NFPA99 ANSI C62.41 ISO 7637-#2b.4 EC MARKING IEC 801.2.3.4.5 ③Software ● InPower TM service software, implementation services to the unit control system Settings and fault diagnosis. ● Power Command for Windows TM monitoring software, implementation computer monitoring and control. ④Optional parts and accessories ● Key model selection switch ● Fault alarm module ● Exhaust temperature monitoring ● Digital remote alarm box ● Digital output module relay ● Power conversion control ● LonWorks network interface ● Engine oil temperature display. > Control system PCC1301 1. Standard function ● ● ● ● ● ●. Precise voltage regulator 3 phase voltage and current detection Engine starting Generator sets monitoring Generator sets protection Operating display. WWW.V-FLO.COM. WWW.V-FLO.COM. ● ● ●.

(7) ● ● ●. Advanced maintainability Ability to adapt to the environment To set the input and output signals. ①Engine control ● Automatic operation mode ● Urgent shutdown ● Sleep mode ● Engine starting ● Multiple-turning ● Engine speed detection ● Mechanical/ electrical speed regulator ● Emergency operation mode ②Alternator control ● Output voltage regulating ● Torque match voltage/frequency overload control. 3. Standard protection ①Generator sets protection ● Programmable alarm and status input ● Urgent shutdown ②Engine protection ● Over-speed shutdown ● Lube low pressure alarm/shutdown ● High water temperature alarm/shutdown ● Low water level alarm ● High/low Battery voltage alarm ● Leak battery alarm ● Starting/ turning failure shutdown ● Sensor fault display ③Alternator ● Low/high alternator voltage shutdown ● Over-current alarm/shutdown ● Less frequent shutdown ● Over frequent shutdown ● Voltage signal loss shutdown ● Exciting magnetic field overload shutdown. 4. Control system components ● ● ● ● ● ●. Control switch—-RUN/OFF/AUTO “Failure /status” indicator Digital display Screen menu to select button Menu button at the next higher level Engine electronic control module. 5. Adjustment parameters ● ● ●. Delayed start:0—300sec Output voltage:±5% Shutdown delay:0-600sec. WWW.V-FLO.COM. WWW.V-FLO.COM. 2. Internal controls.

(8) Model. unit. C33D5. C38D5. C55D5. C70D5. C80D5. standby. 33. 38. 55. 70. 80. Prime. 30. 35. 50. 63. 72. standby. 26.4. 30.4. 44. 56. 64. prime. 24. 28. 40. 50. 58. Control model. PCC1301. PCC1301. PCC1301. PCC1301. PCC1301. Manufacture. cummins. cummins. cummins. cummins. cummins. Engine model. 4B3.3G1. 4B3.3G1. 4BT3.3G2. 4BT3.9G4. 4BTA3.9G1. cylinders. 4. 4. 4. 4. 4. Cylinders arrangement. L. L. L. L. L. Governor type. mechanism. mechanism. mechanism. mechanism. mechanism. inspiration. natural. natural. turbocharged. turbocharged. Turbocharged intercooled. 95*115. 95*115. 95*115. 102*120. 102*120. 18.2:1. 18.2:1. 17.0:1. 16.5:1. 16.5:1. 3.3. 3.3. 3.3. 3.92. 3.92. No-assist/-12. No-assist/-12. kVA. Bore*stroke. mm. Compression ratio. displacement. L ·. C. Min. temperature cold start. No-assist/-4 No-assist/-4 No-assist/-4. Battery capacity. A/Hr. 70. 70. 70. 100. 100. Engine prime power. kWm. 32. 32. 46. 58. 66. Engine standby power. kWm. 36. 36. 51. 64. 73. Speed. r/min. 1500. 1500. 1500. 1500. 1500. Engine voltage regulator. ±1%. ±1%. ±1%. ±1%. ±1%. Engine insulation class. H. H. H. H. H. Prime L/h. 7.1. 8.4. 11.5. 15. 15. Standby L/h. 8. 9.4. 12.9. 16. 17. Lube volume. L. 7.5. 7.5. 8.0. 10.9. 10.9. Base tank volume. L. 144. 144. 144. 112. 112. Coolant volume. L. 7.9. 7.9. 7.9. 17.2. 17.9. Exhaust temp.. Prime 100%·C. 448. 448. 380. 523. 475. Exhaust flow. Prime 100% L/s. 89. 89. 124. 170. 166. Max. exhaust pressure. Standby mmHg. 75. 75. 75. 76. 76. Cool air flow. 50·C radiator m3/s. 1.45. 1.45. 1.45. 1.71. 1.71. Fan pressure head. 50·C radiator mmWg. 10. 10. 10. 13. 13. Burning air flow. M3/h. 120. 126. 172.8. 237.6. 248. Units total radiant heat. kWm. 6.3. 6.3. 10.2. 17.1. 12.6. 100% load fuel. WWW.V-FLO.COM. WWW.V-FLO.COM. KWe.

(9) unit. C110D5. C150D5. C180D5. standby. 110. 150. 180. Prime. 100. 138. 164. standby. 88. 120. 144. prime. 80. 109. 131. Control model. PCC1301. PCC1301. PCC1301. Manufacture. cummins. cummins. cummins. Engine model. 4ISBeG1. 6BTA5.9G2. 6ISBeG1. cylinders. 4. 6. 6. Cylinders arrangement. L. L. L. Governor type. electrical. electrical. electrical. kVA. WWW.V-FLO.COM. KWe. inspiration. Turbocharged inter- Turbocharged intercooled. Bore*stroke. mm. Compression ratio displacement. L ·. C. Min. temperature cold start. Turbocharged intercooled. 102*120. 102*120. 102*120. 17.3:1. 16.5:1. 16.5:1. 3.92. 5.88. 5.88. No-assist/-12. No-assist/-12. No-assist/-12. Battery capacity. A/Hr. 100. 150. 150. Engine prime power. kWm. 94. 131. 150. Engine standby power. kWm. 102. 145. 164. Speed. r/min. 1500. 1500. 1500. Engine voltage regulator. ±1%. ±1%. ±1%. Engine insulation class. H. H. H. Prime L/h. 23. 33. 36. Standby L/h. 25. 35. 40. Lube volume. L. 13.0. 16.4. 19.5. Base tank volume. L. 112. 340. 340. Coolant volume. L. 19.5. 21.9. 22. Exhaust temp.. Prime 100%·C. 550. 578. 551. Exhaust flow. Prime 100% L/s. 170. 391. 363. Max. exhaust pressure. Standby mmHg. 76. 75. 75. Cool air flow. 50·C radiator m3/s. 3.38. 5.43. 5.29. Fan pressure head. 50·C radiator mmWg. 13. 13. 13. Burning air flow. M3/h. 309.6. 518.4. 518.4. Units total radiant heat. kWm. 13.7. 21. 28.4. 100% load fuel. WWW.V-FLO.COM. Model.

(10) C200D5. C220D5. C250D5. C275D5. C300D5. standby. 200. 220. 250. 275. 300. Prime. 182. 200. 227. 250. 275. standby. 160. 176. 200. 220. 240. prime. 146. 160. 182. 200. 220. Control model. PCC1301. PCC1301. PCC1301. PCC1301. PCC1301. Manufacture. cummins. cummins. cummins. cummins. cummins. Engine model. 6CTAA8.3G1. 6CTAA8.3G1. 6CTAA8.3G2. QSL9G5. QSL9G5. cylinders. 6. 6. 6. 6. 6. Cylinders arrangement. L. L. L. L. L. Governor type. electrical. electrical. electrical. Electrical spray. Electrical spray. inspiration. Turbocharged intercooled. Turbocharged intercooled. Turbocharged intercooled. turbocharge. turbocharge. 114*135. 114*135. 114*135. 114*145. 114*145. 16.8:1. 16.8:1. 16.8:1. 16.8:1. 16.8:1. 8.3. 8.3. 8.3. 8.8. 8.8. No-assist/-12. No-assist/-12. kVA. WWW.V-FLO.COM. KWe. Bore*stroke. mm. Compression ratio displacement. L ·. Min. temperature cold start. C. No-assist/-12. No-assist/- No-assist/-12 12. Battery capacity. A/Hr. 150. 150. 150. 150. 150. Engine prime power. kWm. 183. 183. 210. 268. 268. Engine standby power. kWm. 203. 203. 231. 310. 310. Speed. r/min. 1500. 1500. 1500. 1500. 1500. Engine voltage regulator. ±1%. ±1%. ±1%. ±1%. ±1%. Engine insulation class. H. H. H. H. H. Prime L/h. 41. 45. 51. 52.3. 57.3. Standby L/h. 45. 50. 57. 58.2. 66.2. Lube volume. L. 23.8. 23.8. 23.8. 26.5. 26.5. Base tank volume. L. 350. 350. 350. 604. 604. Coolant volume. L. 24.3. 24.3. 24.3. 28.6. 28.6. Exhaust temp.. Prime 100%·C. 553. 553. 565. 500. 500. Exhaust flow. Prime 100% L/s. 530. 530. 681. 490. 490. Max. exhaust pressure. Standby mmHg. 76. 76. 76. 76. 76. Cool air flow. 50·C radiator m3/s. 5.43. 5.43. 5.43. 7.93. 7.93. Fan pressure head. 50·C radiator mmWg. 13. 13. 13. 13. 13. Burning air flow. M3/h. 720. 720. 918. 1116. 1116. Units total radiant heat. kWm. 24. 28. 28. 30. 30. 100% load fuel. WWW.V-FLO.COM. unit. Model.

(11) C330D5. C350D5. C400D5. C440D5. C500D5. C550D5. standby. 330. 350. 400. 440. 500. 550. Prime. 300. 320. 360. 400. 450. 500. standby. 264. 280. 320. 352. 400. 440. prime. 240. 256. 280. 320. 360. 400. PCC1301 PCC2100. PCC2100. PCC2100. PCC2100. PCC2100. Manufacture. cummins. cummins. cummins. cummins. cummins. cummins. Engine model. QSL9G5. NT855G6. NTA855G4 NTA855G7 QSX15G8. QSX15G8. cylinders. 6. 6. 6. 6. 6. 6. Cylinders arrangement. L. L. L. L. L. L. Governor type. Electrical spray. electrical. electrical. electrical. Electrical spray. Electrical spray. turbocharge. Turbocharged intercooled. Turbocharged intercooled. Turbocharged intercooled. Turbocharged intercooled. 140*152. 140*152. 140*162. 137*169. 137*169. 14.0:1. 14.0:1. 14.0:1. 17.0:1. 17.0:1. 14. 14. 14. 15. 15. No-assist/4. No-assist/-4. No-assist/4. kVA. KWe. WWW.V-FLO.COM. Control model. turbocharge. inspiration. Bore*stroke. 114*145. mm. 16.8:1. Compression ratio displacement. 8.8. L ·. Min. temperature cold start. C. No-assist/- No-assist/- No-assist/12 4 7. Battery capacity. A/Hr. 150. 200. 200. 200. 200. 200. Engine prime power. kWm. 268. 280. 317. 355. 444. 444. Engine standby power. kWm. 310. 310. 351. 391. 500. 500. Speed. r/min. 1500. 1500. 1500. 1500. 1500. 1500. Engine voltage regulator. ±1%. ±0.5%. ±0.5%. ±0.5%. ±0.5%. ±0.5%. Engine insulation class. H. H. H. H. H. H. Prime L/h. 63. 69. 76. 75. 80. 103. Standby L/h. 75. 76. 84. 98. 87. 123. Lube volume. L. 26.5. 38.6. 38.6. 36.7. 91. 91. Base tank volume. L. 604. 750. 750. 900. 900. 900. Coolant volume. L. 28.6. 63.9. 65.8. 65.8. 65.9. 65.9. Exhaust temp.. Prime 100%·C. 500. 574. 524. 553. 488. 488. Exhaust flow. Prime 100% L/s. 490. 1071. 1128. 1433. 1255. 1255. Max. exhaust pressure. Standby mmHg. 76. 76. 76. 76. 76. 76. Cool air flow. 50·C radiator m3/s. 7.93. 4.92. 5.99. 5.99. 10.44. 10.44. Fan pressure head. 50·C radiator mmWg. 13. 13. 13. 13. 13. 13. Burning air flow. M3/h. 1116. 1300. 1468.8. 1468.8. 1944. 1944. Units total radiant heat. kWm. 30. 50. 46. 53. 33. 33. 100% load fuel. WWW.V-FLO.COM. unit. Model.

(12) Generator sets model. Engine model. C11D5. Overall dimensions. NET Weight. WET Weight. A. B. C. kg. kg. D1703-BG. 1300. 730. 1130. 361. 376. C15D5. D1703-BG. 1300. 730. 1130. 370. 385. C22D5. 4B3 3G1. 1753. 930. 1256. 544. 609. C33D5. 4B3.3G1. 1753. 930. 1256. 580. 645. C38 D5. 4B3.3G1. 1753. 930. 1256. 640. 705. C55D5. 4BT3.3G2. 1753. 930. 1256. 711. 776. C70D5. 4BT3 9G4. 1950. 10^6. 1221. 1002. 1038. C80D5. 4BTA3.9G1. 1950. 1046. 1221. 1014. 1050. C110D5. 4ISB&G1. 1977. 1046. 1311. 1162. 1200. C150D5. 6BTA5-9G2. 2404. 1100. 1472. 1167. 1216. C180D5. 6ISBeG1. 2404. 1100. 1487. 1400. 1444. C200D5. 6CTAA8.3G1. 2686. 1300. 1547. 1840. 1900. C220D5. 6CTAA8.3G1. 2686. 1300. 1547. 1840. 1900. C250D5. 6CTMS.3G2. 2686. 1300. 1547. 1940. 2000. C275 D5. QSL9G5. 3135. 1100. 1928. 2119. 2171. C300D5. QSL9G5. 3135. 1100. 1928. 2342. 2394. C330D5. OSL9G5. 3135. 1100. 1928. 2422. 2474. C350D5. NT855G6. 3549. 1100. 2078. 2860. 3050. C400D5. NTA855G4. 3549. 1100. 2078. 3037. 3227. C440D5. NTA855G7. 3549. 1100. 2115. 3157. 3347. C500D5. OSX-5G8. 3433. 1500. 2065. 4022. 4117. C550D5. QSX15G8. 3433. 150O. 2065. 4125. 4220. WWW.V-FLO.COM. WWW.V-FLO.COM. > Overall dimension and weight.

(13) Model. Engine model. C11 DS C15 D5 C22D5 C33D5 C38 D5 C55D5 C70D5 C60D5 C110D5 C150D5 C180 D5 C200D5 C220D5 C250D5 C275 D5 C300D5 C330 D5 C350D5 C400D5 C440 D5 C500D5 C550D5 C650D5A 565DFG8 660DFGD C840D5 C900D5 833DFHC 888DFHD 906DFJD C1250D5A C1400 D5 C167S D5A C2000D5 C2250D5 C2500 D5A 2660DQLB. D1703-BG D1703-BG 4B3.3G1 4B3.3G1 4B3 3G1 4BT3.3G2 4BT3 9G4 4BTA3.9G1 4ISBeG1 6BTA5.9G2 6ISBeG1 6CTAAS.3G1 6CTAA8.3G1 6CTAAH3G2 QSL9G5 QSL9G5 QSL9GS NT855G6 NTA855G4 NTA855G7 QSX16G8 OSX1SG8 KTA19G8 VTA28GS VIA28G6 OSK23G3 OSK23G3 QST30G3 QST30G4 KTA38G5 KTA38G9 KTA50G3 KTA50GS8 QSK60G3 QSK60G4 QSK60G8 QSK78G6. 100% fuel Standby power Prime power consume (kw) (kw) (L/hr) 8.8 8 2.7 12 10.4 3.5 17.6 16 4.9 264 24 7.1 30.4 28 8.4 44 40 11.5 56 60 15 64 58 16 B8 80 23 120 109 33 144 131 36 160 146 41 176 160 45 203 182 51 220 20O 63 240 220 573 264 240 63 280 256 69 320 288 76 352 320 68 400 360 93 440 400 103 520 472 122 565 512 140 660 600 147 672 608 151 720 656 161 833 751 184 888 800 202 906 823 209 1000 900 231 1120 1000 261 1340 1200 309 1650 1500 355 1800 1600 394 2000 1800 446 2660 2400 592. N.W(kg). Wet weight (kg). 361 370 544 580 640 711 1002 1014 1162 1167 1400 1840 1840 1940 2119 2342 2422 2860 3037 3157 4022 4125 4225 5730 6389 6550 6700 7152 7712 7960 8650 9099 10324 14649 14863 16690 24637. 376 385 609 64 5 705 776 1038 1060 1200 1216 1444 1900 1900 2OU0 2171 2394 2474 3O50 3227 3347 4117 4220 4350 6040 6699 6873 7023 7450 8000 8350 9400 10075 10626 15152 15366 17217 25280. Overall dimensions (L*W*H)(mm) 1300*730*1130 1300*730*1130 1753*930*256 1753*930*1256 1753*930*1256 1753*930*1256 1950*1046*1221 1950*1046*1221 1977*1046*1311 2404*1100*1472 2404*1100*1487 2686*1300*1547 2686*1300*1547 2686*1300*1547 3135*1100*1928 3135*1100*1928 3135*1100*1928 3549*1100*2078 3549*1100*2078 3549*1100*2115 3433"1500*2065 3433*1500*2065 3419*1285*1906 3900*1423*1942 4047*1423*1942 4593*1502*2066 4593*1502*2086 4297*1448*2082 4547*1702*2332 4470*1785*2229 4565*2083*2225 5105*2000*2238 5811*2033*2756 6175*2287*2537 6175*2287*2537 6175*2494*3116 7158*2251*2535. WWW.V-FLO.COM. WWW.V-FLO.COM. >Cummins diesel generator sets 50HZ , 230V/400V,11kVA-3225kVA.

(14)

References

Related documents

Note: To ensure PowerPanel Shutdown Service could work correctly, all options for the SNMP Trap notification configured from the Event Action page of the CyberPower

This is because an increase in the availability of the substrate sucrose will allow more yeast cells to use the substrate for cellular respiration in the mitochondria—and the

(a) The pigP protein trap element used in [47]: the transposon ends (blue triangles) flank a genetic marker gene (white) and an artificial exon, which in this case contains the

We propose a nuanced conceptual understanding of adventure tourism within an ecological dynamics perspective that considers the relationship between the person, the adventure

Where to File: Business Returns Filing Addresses—2015 Returns Principal Business Activity Codes—Forms 1065, 1120 and 1120S Business Quick Facts Data Sheet. Types of Payments—Where

• Single and three phase fault regulation • Over and under voltage shutdown • Over and under frequency shutdown • Overload warning with alarm contact • Reverse power

I sought to examine the influence of various dimensions of HIV/AIDS stigma, which included public stigma of prejudice, self-stigma of negative attitudes, enacted stigma of abuse,

Once initial and final stress conditions have been established, it is necessary to determine the relation- ship between void ratio and vertical effective stress for the in situ