REQUIREMENTS:
1 2 3 4PROCEDURE
1 2 3 4 5 6 7 8 9 10 11 12 13and observe if the script loading will continue
If already finished with script loading, check the status of the 2nd DUW with EMAS (needs to be enabled)
Load the Cabinet and Site with 3rd Carrier Configuration Softwares (Element Manager, PUTTY or HyperTerminal, Bison)
Call Integration to perform HC and Backup CV for Site
Wait until the synch status of the 2nd DUW is “StandbyReady” Verify with Integration Team for the Status of 2nd DUW Create a CV (Ex. After_DUW_sync )
Start upgrading to
R3M02
Export and Delete the Configuration. Do the cabling as shown in the Layout
Note: If script loading is taking too much time (more than 10 mins) you need to switch "OFF" and the switch "ON" again the Secondary DUW Run the modify script to add the 2nd DUW to the RBS (switch on 2nd DUW if you see
“waiting for start up of board” in the Modify-Wizzard
Check the status of the 2nd DUW with MOSHELL using “cab”
With the command “cab” you see that the 2nd DUW is in synch status. (Need to restart cabinet if 2nd DUW is not showing on moshell) All materials needed should be available (SUBRACK, CABLES, ADDITIONAL DUW) see Layout for Cable reference
Script for 3rd Carrier Configuration
Proper Tools (Laptop with Cables to Connect to RBS6201, 2nd Subrack Installation)
Open MDT call Integration to perform HC and Backup CV for Site Install 2nd SUBRACK
Insert 2nd DUW into the expansion (still powered down)
Switch "ON" and Format Secondary DUW
(NO CABLES CONNECTED)
. After Format Switch"OFF" againRBS6201 3RD CARRIER IMPLEMENTATION
and observe if the script loading will continue
If already finished with script loading, check the status of the 2nd DUW with EMAS (needs to be enabled)
Load the Cabinet and Site with 3rd Carrier Configuration Softwares (Element Manager, PUTTY or HyperTerminal, Bison)
Call Integration to perform HC and Backup CV for Site
Wait until the synch status of the 2nd DUW is “StandbyReady” Verify with Integration Team for the Status of 2nd DUW Create a CV (Ex. After_DUW_sync )
Start upgrading to
R3M02
Export and Delete the Configuration. Do the cabling as shown in the Layout
Note: If script loading is taking too much time (more than 10 mins) you need to switch "OFF" and the switch "ON" again the Secondary DUW Run the modify script to add the 2nd DUW to the RBS (switch on 2nd DUW if you see
“waiting for start up of board” in the Modify-Wizzard
Check the status of the 2nd DUW with MOSHELL using “cab”
With the command “cab” you see that the 2nd DUW is in synch status. (Need to restart cabinet if 2nd DUW is not showing on moshell) All materials needed should be available (SUBRACK, CABLES, ADDITIONAL DUW) see Layout for Cable reference
Script for 3rd Carrier Configuration
Proper Tools (Laptop with Cables to Connect to RBS6201, 2nd Subrack Installation)
Open MDT call Integration to perform HC and Backup CV for Site Install 2nd SUBRACK
Insert 2nd DUW into the expansion (still powered down)
Switch "ON" and Format Secondary DUW
(NO CABLES CONNECTED)
. After Format Switch"OFF" againINTEGRATION
TEAM
RPM 777 263 / 00650 - R1B
SIGNAL CABLE
(IDL to IDL Connection from Primary to Secondary DUW)
RPM 777 193 / 01000 R1C
DC POWER CABLE WCDMA Need Additional 1 pc
(Power Cable for Secondary DUW)
Connected to PDU
IMPORTANT
IDL Cable labeled with "
PRIMARY
" should be connected to the primary DUW and "SECONDARY
" to secondary DUW and do not be mistaken to interchange, otherwise primary DUW will be corruptedRPM 777 279 / 00650 R1B
SIGNAL CABLE
( F to F Connection from Primary to Secondary DUW)
RPM 777 277 / 00900 R3A
SIGNAL CABLE
(approximate length 1m)
Need additional 3 pcs for 3rd Carrier
(Connection from RUW to Secondary DUW)
RPM 777 277 / 00900 R3A
SIGNAL CABLE
(approximate length 1m)
Existing from Cabinet Delivery (3pcs Only)
(Connection from RUW to Primary DUW)
CABLES NEEDED FOR 3rd CARRIER
RPM 777 277 / 00900 R3A
RPM 777 263 / 00650 -
RPM 777 279 / 00650 R1B
Existing from Cabinet Delivery (3pcs Only)
(Connection from RUW to Primary DUW)
CABLES NEEDED FOR 3rd CARRIER
RPM 777 277 / 00900 R3A - 3pcs
RPM 777 263 / 00650 - R1B - 1pc
RPM 777 279 / 00650 R1B - 1pc
RPM 777 263 / 00650 - R1B
SIGNAL CABLE
(IDL to IDL Connection from Primary to Secondary DUW)
RPM 777 279 / 00650 R1B
SIGNAL CABLE
( F to F Connection from Primary to Secondary DUW)
RPM 777 277 / 00900 R3A
RPM 777 193 / 01000 R1C
DC POWER CABLE WCDMA Need additional 1 pc
(Power Cable for Secondary DUW) RPM 777 277 / 00900 R3A
SIGNAL CABLE
(approximate length 1m)
Need additional 3 pcs for 3rd Carrier
username: rbs password:
rbs
Welcome to OSE Shell ose5.3.
$
reload
--OSE Delta PowerPC/BL250206 Welcome to OSE Shell ose5.3.
$ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT Plug-in Unit Product Name: DUW3001
Plug-in Unit Product No: KDU127161/3 Plug-in Unit Product rev: R3C
Plug-in Unit Product Date: 20110120 Plug-in Unit Product Serial: CB4G222342 Ethernet MAC_address 0: 0xC835B842FAA2 RAM size: 1024 Mbytes
Stop due to remain in basic/backup set
formathd /d
All data on volume will be destroyed. Continue? y/n (n):
y
Formatting Hard Disk...$
reload
--OSE Delta PowerPC/BL250206 Welcome to OSE Shell ose5.3.
$ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT Plug-in Unit Product Name: DUW3001
Plug-in Unit Product No: KDU127161/3 Plug-in Unit Product rev: R3C
Plug-in Unit Product Date: 20110120 Plug-in Unit Product Serial: CB4G222342 Ethernet MAC_address 0: 0xC835B842FAA2 RAM size: 1024 Mbytes
Stop due to remain in basic/backup set
formathd /c2
All data on volume will be destroyed. Continue? y/n (n):
y
HOW TO FORMAT DUW
Formatting Hard Disk...
$
reload
--OSE Delta PowerPC/BL250206 Welcome to OSE Shell ose5.3.
$ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT Plug-in Unit Product Name: DUW3001
Plug-in Unit Product No: KDU127161/3 Plug-in Unit Product rev: R3C
Plug-in Unit Product Date: 20110120 Plug-in Unit Product Serial: CB4G222342 Ethernet MAC_address 0: 0xC835B842FAA2 RAM size: 1024 Mbytes
Stop due to remain in basic/backup set
ifconfig le0 169.254.1.1 netmask 255.255.0.0
$1.1 Serial Connection Pin outs
2 from serial to 3 on RJ45 3 from serial to 2 on RJ45 5 from serial to 1 on RJ45
The connection between a DUW and a PC for serial connection (RS232) should look like this. Please note that this is applicable for DUW/DUL/DUG.
use FEMALE serial
output power 3-7-11 / 60 st plugin txdev 0-3/1-3 hscode 1-1/2-2/3-3/1/2/3 get . Pool2 25/25 32574 32575 32576