• No results found

IT CHANGE MANAGEMENT POLICY

N/A
N/A
Protected

Academic year: 2021

Share "IT CHANGE MANAGEMENT POLICY"

Copied!
12
0
0

Loading.... (view fulltext now)

Full text

(1)

Page 1 of 2

IT CHANGE MANAGEMENT POLICY

PURPOSE

The purpose of the IT Change Management Policy is to manage

changes in a planned and predictable manner in order to assign

resources, assess risk and minimize any potential negative

impact to services at the University.

SCOPE

This Policy applies to all ITS staff at Brock University.

POLICY

STATEMENT

All changes (including urgent / emergency changes) to IT

resources, services and / or systems must follow a standard

process to ensure appropriate planning, resourcing and

execution. The Change Manager along with the Change Advisory

Board (CAB) are the stewards of this process.

All changes must be presented to the CAB for approval in order

to coordinate timelines, avoid conflict and maintain a complete

and controlled view of change at the University. The CAB will

in turn maintain a record and schedule of all changes and

communicate the changes to the Brock community.

DEFINITIONS

Refer to the Change Management Procedure.

COMPLIANCE

AND REPORTING

ITS enforces this Policy and the related Standards at all times.

Anyone who has reason to suspect a deliberate and / or

significant violation of this Policy is encouraged to promptly

report it to the Information Technology Services (“ITS”) Help

Desk.

Policy violations that come to the attention of the ITS Help Desk

will be escalated to the Director, Client Services. Policy

(2)

IT Change Management Policy Page 2 of 2

violation, including consequences where appropriate, subject to

collective agreements and / or other contractual conditions.

Where Policy violations are considered severe and / or cannot

be easily remediated, the incident will be escalated to the AVP,

ITS for further action. Periodically, the AVP, ITS will provide to

SAC a summary of all policy violations.

Policy owner:

Associate Vice-President, Information Technology Services

Authorized by:

Board of Trustees, Capital Infrastructure Committee

Accepted by:

Senior Administrative Council

Effective date:

March 2016

Next review:

March 2017

Revision history:

New

Related documents:

IT Change Management Standards

Change Management Procedure

(3)

Page 1 of 2

IT CHANGE MANAGEMENT STANDARDS

PURPOSE

A standard includes specific low level mandatory controls that

help enforce and support a policy.

The purpose of this document is to support and outline in detail

the requirements of the IT Change Management Policy. These

requirements are mandatory and must be adhered.

STANDARDS

All changes to an IT resource / service must be submitted to,

reviewed and approved by the Change Advisory Board (CAB)

The CAB is chaired by the Change Manager and includes ITS

representatives from Client Services, Infrastructure, and

Application Development

The purpose of the CAB is to understand, authorize and

schedule proposed changes to Brock University’s production

IT environment

IT Stakeholders from outside of ITS (e.g. Library, FAHS, GSB,

COSC etc.) are welcome to attend CAB meetings and have

view access to the CITS-Activity Calendar

The CAB has the authority to re-schedule, deny or request

further detail regarding any Change Request

The CAB must maintain, track and communicate all Change

Requests using, but not limited to:

o Footprints Ticket

o Footprints Projects

o ITS CITS-Activity Calendar

o Brock Portal Bulletins

o Mailing Lists (ITSFYI, CSL-L)

The CAB is responsible for governance, not execution

activities

(4)

Page 2 of 2

success of their respective change

All changes to an IT resource, service or system must be

performed in compliance with the Change Management

Procedure. These include, but are not limited to:

o Firewall rule changes (additions, changes, deletions)

o Changes to production network infrastructure

(hardware and/or configuration)

o Changes to production server infrastructure (hardware

and/or configuration)

o Enterprise applications (code releases, updates and

maintenance)

The CAB will meet weekly to review Change Requests in

accordance with the timelines outlined in the Change

Management Procedure

Urgent/Emergency change requests to prevent an imminent

failure or to repair a service outage in the production

environment may be expedited through the Emergency CAB

(ECAB) process outlined in the Change Management

Procedure

Changes that do not comply with the IT Change Management

Policy, or that are implemented without the knowledge of

the CAB are unauthorized

o IT Resources will not be made available for

unauthorized changes

o ITS has the authority to reverse any unauthorized

changes that cause, are suspected as causing or have

the potential to cause disruption to other users of the

services.

(5)

1

Information Technology Services

Change Management Procedures

Brock University ITS – Client Services Document Version 1.0 December 12, 2014

(6)

2

Introduction

All changes to an IT resource, system or service must follow the standard procedure outlined below to ensure appropriate resourcing, planning and execution.

Change Classifications and Definitions

Changes Categories

Routine

A routine change is a scheduled change that is done routinely to maintain or tune a resource, service or system, e.g., performing Windows updates on a server, installing a security patch on an appliance. Routine changes have a “Minor” Client Impact Rating and a “Low” Technology Risk (see “Technology Risk Rating” and “Client Impact Rating” below)

Standard

A standard change is a scheduled change that has a “Moderate” Client Impact Rating. Standard changes have the potential to impact a larger portion of the user community, e.g., a network switch upgrade in a building that may impact multiple departments

Enterprise

An enterprise change is a scheduled change that has a “Moderate” to “Major” Client

Impact Rating and has the potential to impact University operations, e.g., taking the “my.brocku.ca” portal offline for upgrades or maintenance

Emergency

An emergency change is an unscheduled change that has a “Moderate” to “Major” Client Impact Rating but must be performed quickly to address a service outage, prevent an outage, or fix a critical problem, e.g., deploying a critical security patch to all

Windows servers, restarting the entire wireless network in order to address a performance issue.

Technology Risk Ratings

Low

A technology change with little or no interactions with other resources, services or systems, e.g., Bomgar, KACE, stand-alone Windows servers

Significant

A technology change with increased interactions with other resources, services or systems, e.g., “Radius Authentication” (affects wired and wireless services), e-mail

High

A technology change with many interactions with other resources, services or systems,

(7)

3

Client Impact Ratings

Minor

A change that has the potential to disrupt a group of 1-25 users

Moderate

A change that has the potential to disrupt a group of 26-100 users

Major

A change that has the potential to disrupt a significant group of over 100 users

Change Classification Matrix

Change Category Technology Risk

Client Impact

Student/Faculty/Staff

Change Approval Required

Routine

Low

Minor

No*

Standard

Low

Moderate

Yes

Significant

Moderate

Yes

Enterprise Change

Significant

Major

Yes

High

Moderate / Major

Yes

Emergency

High

Major

Yes

*While “Routine” changes are still documented and scheduled, after initial approval, subsequent approvals for the same change are not required, e.g., weekly Windows server patching which occur during a regularly scheduled maintenance period.

Maintenance Windows

ITS maintains specific scheduled times in which work on resources / services / systems is preferred in order to minimize disruptions. The times listed below are listed as maintenance times on specific pages (e.g. Webmail, Portal, Sakai) in order to notify our users that work may be performed during these times and therefore the resource / service / system may be unavailable. Work may be performed outside of these scheduled maintenance windows but must be communicated (see “Communications” below).

(8)

4

Scheduled ITS Maintenance Windows

Change Category Change Window Notice required Routine No predefined window Not Applicable Standard Monday – Friday

6:00 AM – 8:00 AM 5 Business Days Enterprise Saturday

12:00 AM – 10:00 AM

10 Business Days Emergency Determined by Change Manager

and/or ITS Director

Determined by Change Manager and/or ITS Director

Maintenance Freeze Periods

Annual times for maintenance freeze Change Category Allowed 4th week of August to 3rd week of

September Routine and Emergency

The week-and-a-half before the Christmas Break (Payroll)

Routine and Emergency

Roles and Responsibilities

Change Manager

The Change Manager is responsible for managing Change Management for ITS. This individual focuses on the change process as a whole rather than the specifics of the work within each individual change. The Change Manager’s responsibilities include:

 Ensuring that Change Requests are formatted and submitted to the CITS-Activity Calendar from Change Initiators

 Maintaining the CITS-Activity Calendar and its membership  Facilitating CAB meetings

 Reviewing Technology Risk and Client Impact Ratings for all submitted Change Requests  Publishing Change Notifications to the community

 Documenting, publishing and assessing compliance with the Change Management process  Reviewing, evaluating and maturing the change process.

Change Initiator

All members of ITS are permitted to submit change requests as Change Initiators. Change Initiators are responsible for:

(9)

5

 Initiating change requests by completing the Change Request Template and submitting it to the CITS-Activity Calendar

 Assuring that all change requests are documented and linked to either a Footprints Ticket or Footprints Project Number

 Assisting the CAB when further information is required about pending change requests.

Change Advisory Board (CAB)

The Change Advisory Board is a group of individuals that formally meet to review change requests. The CAB is comprised of departmentally-appointed individuals to act as contributors and is chaired by the Change Manager.

 The CAB Meets every Tuesday morning, at 9:30 to review and schedule change requests (see “Change Request Process”)

The CAB as a whole Approves, Denies or Recycles proposed change requests and documents the change of status in the CITS-Activity Calendar.

 At the conclusion of the CAB meeting, members pass along Change Management related information to the Change Initiators/Staff in their respective departments, e.g., if a change request was moved due to a scheduling conflict, or more information is required for a particular change request.

Emergency Change Advisory Board (ECAB)

The Emergency Change Advisory Board is a group of individuals that must meet in extraordinary circumstances in order to approve an Emergency Change Request. Emergency change requests requiring an ECAB are un-planned and require the approval from one of the following prior to change implementation:

 AVP, Information Technology Services  Director, Application Development  Director, Client Services

 Director, IT Infrastructure.

Emergency change requests still need to be recorded in the CITS-Activity Calendar (using the Change Template) but are expedited in order to recover from a critical resources, service or system outage.

Communication Plan

In order to keep the University community informed of changes and planned maintenance of IT resources, services and systems, the Change Manager must:

 Keep the CITS-Activity Calendar up-to-date with all change requests, important dates and maintenance freezes

(10)

6

 Ensure that web systems such as Webmail, LMS and the portal have the maintenance schedule identified on their log-on pages

 Post approved change requests to the my.brocku.ca portal identifying the work being performed, who it may affect, the scheduled date and duration

 Additional e-mails may be sent to individuals/groups at the discretion of the Change Manager

Change Management Workflow

Change requests must reference a Footprints ticket or project number. The Footprints system is where all of the information regarding the specifics of the Change Request are to be kept. The detailed information in the ticket must include, but is not limited to:

 Work required

 Required resources (people/teams)  Resources / services / systems affected  Users / groups affected

 Work plan  Back out plan

Change Request Statuses

All Change Requests are submitted to the CITS-Activity Calendar with the starting status of Proposed. Statuses explained:

Proposed

A proposed change awaiting CAB review

Approved

A CAB reviewed change that is approved to proceed

Recycled

A CAB reviewed change that requires more information or needs to be rescheduled based on resource availability

Rejected

A CAB reviewed change that is not approved to proceed due to insufficient planning, resources or not referencing a Footprints ticket or project number

Procedure for Routine, Standard or Enterprise Change Requests (CAB Changes)

1. The Change Initiator creates Footprints ticket/project

2. The Change Initiator submits change request (using “Change Template”) to the CITS-Activity Calendar as a proposed change

3. The CAB reviews the change request in the CITS-Activity Calendar and as a group Approves, Recycles or Rejects the individual change request

4. The CAB Contributors notify their individual department/change initiators of changes that are allowed to proceed

(11)

7

5. Using the Communication Plan, the Change Manager communicates the upcoming approved changes

6. Work on the Approved Changes is performed and tracked in Footprints.

Procedure for Emergency Changes (ECAB Changes)

1. A service outage, vulnerability or proactive event is identified and recorded in Footprints by anyone

2. The Footprints ticket is immediately escalated to a supervisor/manager/director 3. Any available CAB members and/or an ITS Director (as the ECAB) meets with ITS Staff

knowledgeable with the situation to discuss course of action, and approve the Emergency Change

4. The community is notified of the emergency work being performed 5. The Emergency Change Request is posted to the CITS-Activity Calendar 6. Footprints ticket(s) are updated throughout the work.

(12)

8

Appendix A – Change Template

Changes are to be tracked using the CITS-Activity Calendar in Exchange (accessed through Microsoft Outlook). The following template must be included the in body of each Proposed Change Request (as a calendar event):

SUBJECT: Insert BRIEF Title along with Footprints Ticket or Project Number here. STATUS: PROPOSED

PROPOSED CHANGE SUMMARY: Provide a quick summary of the proposed Change Request. OTHER INFORMATION: Place to provide any other information regarding this Change Request. PROPOSED CHANGE TIMELINE: Provide information regarding the proposed date and time for the actual work to be performed.

CHANGE CATEGORY: (The Change Initiator selects the appropriate Change Category). Routine

Standard Enterprise Emergency

TECHNOLOGY RISK: (The Change Initiator selects the appropriate Technology Risk from the Technology Risk Rating assessment).

Low Significant High

CLIENT IMPACT: (The Change Initiator select the appropriate Client Impact choice based on the Client Impact Rating).

Minor Moderate Major

RESOURCES: (The Change Initiator indicates the individuals/teams required as a quick-reference to perform the work for this change).

References

Related documents

Control over IT is achieved by instituting effective policies, then implementing robust controls to ensure that all changes are auditable and authorized, and that

Ypres (Menin Gate) Memorial, West-..

 For a Major change type the full CAB will review the change request at their weekly meeting. The CAB will conduct reviews as needed until the CM process is finalized, at which

[r]

previously agreed admission date, then the patient’s clock should still be ‘paused’ and the start of the ‘pause’ will remain unchanged (it will still be the earliest

This study covers wave energy, tidal current and offshore wind energy systems and discusses physical modelling of Power Take-Off (PTO) systems, numerical modelling of MRE devices and

Standard A: Students will acquire the skills to investigate the world of work in relation to knowl- edge of self, and to make informed career decisions..?. Write down

• Check Wire Harness connections to the Drain Pump, Pressure Switch, and Central Control Unit (CCU) • Check / Clean Drain Pump Filter of foreign objects • Check for Drain