• No results found

Be ready for emergencies

N/A
N/A
Protected

Academic year: 2021

Share "Be ready for emergencies"

Copied!
12
0
0

Loading.... (view fulltext now)

Full text

(1)

pas

com alarm server

Be ready for emergencies

(2)

We simplify

your processes ...

by integrating various moduls

into a unified system!

pascom is an Austrian development company and IT service provider. Our hardware and software solutions are used in the following areas:

SmartCard systems, one card for all applikationsEntertainment solutions especially for healthcare and

Alerting and

information

SmartCard

system

Entertainment

solutions

Development, production and installation

of hardware and software

(3)

No data redundancies

Isolated data solutions generally do not offer inter-faces to up- or downstream systems, and entail data redundancies. With the pascom system you only have to enter your data once.

Location-independent use

The system ensures at any location of your company a unified billing, location-independent alerting and access to the central information system.

Connection of external systems

Because of the modularity and adaptability of the system we are able to meet the growing customer requirements.

Easy system expansion

Our highly skilled development team for hardware and software ensures the continuous development of our management system.

Development in the house

pascom

management system

All with one SmartCard

The pascom management system allows the use of a single SmartCard for all applications: from access, time recording, single-sign-on up to cash-less payments throughout the house.

The central pascom management system manages people, applications and devices as well

as the billing of sevices. pascom is the ideal solution to create from a heterogeneous system

landscapes a homogeneous and powerful platform.

(4)

pascom alarm server

For an effective and efficient emergency alarm system

In case of an emergency, every second matters for the life to be saved. The alerting process is becoming more and more prominent, because a fast alarm trans-mission can avert greater damage. The pascom alarm server helps you to minimize this time period consi-derably and to maximize your efficiency.

Saving up to 95% in time

(5)

5/12 We simplify your processes!

The pascom WebClient, a web-based administration tool for all pascom modules

The System

The pascom alarm server is based on a client-server architecture and with its modular system we can cus-tomize it to fit your needs perfectly - an affordable and easily upgradeable system. Due to its different inter-faces, it can be integrated into your existing technical infrastructure without any problems.

Stability, reliability and security are the minimum requirements fulfilled by the pascom alarm server. Uninterrupted power supply, watchdog monitoring, remote maintenance and security logging are a must have for every alarm system.

Operation

In case of an emergency signal sent from an internal or external alarm sensor, the alarm server independently contacts both internal and external rescue teams and informs them via text message or spoken message of the situation.

In order to provide maximum security a predefined number of emergency calls has to be acknowledged after an alarm notification. If an alarm is not acknow-ledged the system can contact the person again after a set time.

Escalation plan

In case the number of alarm acknowledgements falls below a defined minimum the escalation plan beco-mes effective. This means further participants can be connected. The system will repeat this until enough helpers have reached the scene of emergency.

(6)

Alarm transmitter

The modular design of the system provides

you with the opportunity to individually

incorporate it into your already existing

system.

„ Alarm contacts

The simplest type of alarm triggering is by using poten-tial-free contacts such as relays or alarm buttons.

„ Remote activation via telephone

The alarm can also be triggered by identification via PIN code after calling an alarm number from a hard-line or mobile phone.

„ IT-network

Using TCP / IP protocols, the alarm server can easily connect to your existing network (e.g. BMS) and auto-nomously contact the people responsible in case of specific emergencies.

„ Personal alarm

If a personal alarm is triggered the connection to the pascom alarm server can provide rapid and efficient help.

„ System alerting

(7)

7/12 We simplify your processes!

Ready for any kind of emergency

The pascom alarm server is ready for any

kind of alarm.

„ Medical emergencies:

It is of greatest importance to not only contact the rescue and emergency resuscitation teams in time, but also provide them with the most essential informations as fast as possible.

„ Technical problems:

Equipment failures or technical failures can often draw disastrous consequences. To avoid or prevent serious damage a incident-driven selective alarm call to the people responsible is absolutely essential.

„ Danger alarms such as fire or burglary:

Dangers such as a fire or a break-in must be recog-nized by the already installed technical equipment and immediately forwarded to the alarm server. A reli-able notification of the fire department, the police, the security service or other authorities is in a situation like that of great importance.

„ Evacuation:

In case of an emergency all people currently in the building need to be informed and briefed on the upco-ming evacuation. Therefore, the warning and instruc-tion messages of the alarm server are programmable in various different languages to help and reach all people.

„ Other services:

(8)

The top priority of an alarm system besides triggering the alarm as fast as possible must be the timely notifi-cation of the corresponding group of people. Because of this the pascom alarm server supports both audible and visual alarms.

The ringtone can be changed to either 'normal' or 'urgent'. Depending on the configuration of your telephone system, the system also provides you with options such as continuous tone, call interruption or intrusion.

For optimal security you can optionally enable the multiline function, which allows you to notify a person even during a phone call provided that the specific telephone has not activated call forwarding.

Media:

Both wired and mobile internal or external devices can be contacted and informed in writing and lan-guage of the emergency with the pascom alarm server. For example, the following media can be contacted:

„ hardline phone

„ mobile phone

„ text message

„ e-Mail

„ pager

„ fax with recall confirmation

„ IT-network

Alarm receiver

Alerting individuals and groups:

Informing an individual person or an entire group of people responsible in a specific case of emergency, which you defined beforehand, is easy and user-friendly with the alarm server. Depending on the situ-ation different communicsitu-ational channels for indivi-duals or groups can be chosen. If one of the alarms is not acknowledged, for example via the internal tele-phone, then the system automatically sends a notifica-tion with the next medium on the list.

Acknowledgement:

(9)

9/12 We simplify your processes!

Administration

pascom WebClient, web-based administration tool

In management, processing and analysis the system supports you with its Windows interface. The requi-red training for your employees will be requi-reduced to a minimum.

Due to the client/server architecture of the alarm server, you can change your data directly on the server or any other personal computer connected to the buil-ding network.

(10)

Specifications

Producer Hewlett Packard Type HP DL380 G7 Hexa Core mouse + Keyboard Monitor optional Dimensions: BxTxH: 445,4 x 699,8 x 85,9 mm Weight 21.45 kg Extensions/Connectivity supply: Hot-Plug power: 460 Watt

Einschübe: Hot Swap - 2.5“ SFF slots: 3x PCI Express x8 3x PCI Express x16 18 RDIMM-Steckplatz

Massenspeicher-Controller

Type: 1x Raidcontroller (SATA 150 SAS) RAID Level: RAID 0

RAID 1 RAID 5 RAID 10 Montage Rack Montage - 2U Memory 3 x 146 GB disk operating system/software

Microsoft Windows Server 2008 Microsoft SQL Server 2008 R2

RAM

8 GB DDR3 RAM

Network

(11)

11/12 We simplify your processes!

Specifications

Supply:

power Supply in: 230V~50Hz 0,15A power Supply out: 12V=2,1A +/-10% power per module: max. 12W connectors:

1x LAN: 10MBIT temperature: 10 - 40 C˚

pascom fail over box

The pascom fail over box allows fail-safe operation of the contact box. It controls the functionality of the main and backup server.

If the master server doesn´t work, the pascom FailO-verBox switches to the backup server. So a fail-safe operation of the contact box is possible.

For fail-safe operation of the contact box

pascom contact box

Specifications

Supply:

Power Supply input: 220V~50Hz Power Supply output: 12V/25W

Connections per CPU card:

1x supply output : 12V

1x Watchdog input: potential-free input 8x output: potential-free output

24x input: potential-free input 8x Common connections: for inputs

Monitoring of the alarm server

The pascom contact box is used to monitor the alarm server and for reading and setting of alarms.

It consists of a CPU module and up to 8 I / O cards, each I / O card has 8 outputs and 24 inputs and can be connected via RS232 or RS485 to the alarm server.

Operating temperature: 10 °C - 40 °C Dimensions:

(12)

References

Related documents

Through the transmission of a high power signal on the same frequency of a cell phone, the jamming device creates a competing signal that covides with and

More specifically, there was a higher percentage of persons with private insurance only all year (78.5 percent), public insurance only all year (84.5 percent), and a combination

It can send a TCP message and it can receive trigger signal from external alarm systems as well as send trigger signal to other existing alarm systems. For example if there are door

• Presenter at Apple University Consortium’s /dev/world Conference in Melbourne, Australia, September 2011. Session title: “Introducing the <canvas> element with

The Child Care Worker is responsible to the Director Colleen Gale Children’s Services for coordination of activities within the Service’s operation, the supervision of children and

• 2) Analyze North Carolina textile companies using Clusters and Global Competitiveness Framework (fishbone diagram). • 3) Determine needed assistance for companies • 4)

• I define the semantics of my metadata categories myself • Plus in CMDI you can describe any resource you like:.. – collections/corpora, single texts – historical sources,

According to Figure 1, participants affirmed that the causes of payment default for municipal services include communication issues, lack of implementation of credit policies,