AIR CONDITIONER

Wall mounted type

DESIGN & TECHNICAL MANUAL

For Extra Cold Climate Area

INDOOR

ASUH09LMAS ASUH12LMAS

OUTDOOR

AOUH09LMAH1 AOUH12LMAH1

DR_AS131EF_03 2021.06.24

(2)

Notices:

• Product specifications and design are subject to change without notice for future improvement.

• For further details, please check with our authorized dealer.

Trademarks

FGLair is trademark of Fujitsu General Limited in the United States, other countries or both.

Google Play is trademark of Google Inc.

App Store® is a service mark of Apple Inc., registered in the U.S. and other countries.

Copyright © 2020 Fujitsu General Limited. All rights reserved.

(3)

CONTENTS

Part 1. INDOOR UNIT...1

1. Specifications...2

2. Dimensions...4

2-1. Models: ASUH09LMAS and ASUH12LMAS ...4

2-2. Installation space requirement ...5

3. Wiring diagrams ...6

3-1. Models: ASUH09LMAS and ASUH12LMAS ...6

4. Capacity table...7

4-1. Cooling capacity...7

4-2. Heating capacity ...9

5. Fan performance ...10

5-1. Air velocity distributions...10

5-2. Airflow ...11

6. Operation noise (sound pressure)...13

6-1. Noise level curve...13

6-2. Sound level check point ...13

7. Safety devices ...14

8. External input and output...15

8-1. External input ...15

8-2. External output...18

8-3. Combination of external input and output...20

8-4. Details of function ...22

9. Group connection ...46

10. Remote controller ...47

10-1.Wireless remote controller ...47

11. Function settings ...49

11-1.Function settings by using remote controller...49

11-2.Custom code setting for wireless remote controller...58

12. Accessories ...59

12-1.Models: ASUH09LMAS and ASUH12LMAS ...59

13. Optional parts ...60

13-1.Controllers ...60

13-2.Others ...61

(4)

Part 2. OUTDOOR UNIT...63

1. Specifications...64

2. Dimensions...65

2-1. Models: AOUH09LMAH1 and AOUH12LMAH1...65

3. Installation space ...66

3-1. Models: AOUH09LMAH1 and AOUH12LMAH1...66

4. Refrigerant circuit ...69

4-1. Models: AOUH09LMAH1 and AOUH12LMAH1...69

5. Wiring diagrams ...70

5-1. Models: AOUH09LMAH1 and AOUH12LMAH1...70

6. Capacity compensation rate for pipe length and height difference...71

6-1. Models: AOUH09LMAH1 and AOUH12LMAH1...71

7. Additional charge calculation ...72

7-1. Model: AOUH09LMAH1...72

7-2. Model: AOUH12LMAH1...72

8. Airflow ...73

8-1. Model: AOUH09LMAH1...73

8-2. Model: AOUH12LMAH1...73

9. Operation noise (sound pressure)...74

9-1. Noise level curve...74

9-2. Sound level check point ...75

10. Electrical characteristics ...76

11. Safety devices ...77

12. Accessories ...78

12-1.Models: AOUH09LMAH1 and AOUH12LMAH1...78

CONTENTS (continued)

(5)

Part 1. INDOOR UNIT

WALL MOUNTED TYPE:

ASUH09LMAS

ASUH12LMAS

(6)

1. Specifications

Type Wall mounted

Inverter heat pump

Model name ASUH09LMAS ASUH12LMAS

Power supply 208/230 V ~ 60 Hz

Power supply intake Outdoor unit

Available voltage range 187—253 V

Capacity

Cooling

Rated kW 2.64 3.52

Btu/h 9,000 12,000

Min.—Max. kW 1.0—3.37 1.0—3.90

Btu/h 3,400—11,500 3,400—13,300

Heating

Rated kW 3.52 4.69

Btu/h 12,000 16,000

Min.—Max. kW 0.82—4.69 0.82—5.60

Btu/h 2,800—16,000 2,800—19,100

Heating (17 °F)*1

Rated kW 2.17 3.02

Btu/h 7,400 10,300

Max. kW 3.09 3.72

Btu/h 10,550 12,700

Input power

Cooling Rated

kW

0.585 0.960

Min.—Max. 0.14—1.27 0.14—1.27

Heating Rated 0.79 1.28

Min.—Max. 0.14—1.67 0.14—1.67

Heating (17 °F)*1

Rated 0.68 1.04

Max. 1.39 1.39

Current Cooling

Rated A 3.0 4.7

Heating 3.9 6.0

EER Cooling kW/kW 4.51 3.66

Btu/hW 15.4 12.5

COP Heating kW/kW 4.45 3.66

Btu/hW 15.2 12.5

SEER Cooling Btu/hW 26.5 23.0

HSPF Heating Btu/hW 13.0 12.5

Power factor Cooling

% 84.8 88.8

Heating 88.1 92.8

Moisture removal pints/h (L/h) 2.7 (1.3) 3.8 (1.8)

Maximum operating current*2 Cooling

A 6.9 6.9

Heating 9.4 9.4

Fan

Airflow rate Cooling

HIGH

CFM (m3/h)

453 (770) 453 (770)

MED 353 (600) 353 (600)

LOW 265 (450) 265 (450)

QUIET 147 (250) 147 (250)

Heating

HIGH 453 (770) 453 (770)

MED 377 (640) 377 (640)

LOW 306 (520) 306 (520)

QUIET 182 (310) 182 (310)

Type × Q'ty Crossflow fan × 1

Motor output W 49

Sound pressure level*3

Cooling

HIGH

dB (A)

43 43

MED 36 36

LOW 30 30

QUIET 19 19

Heating

HIGH 43 43

MED 38 38

LOW 33 33

QUIET 21 21

Heat exchanger type

Dimensions (H × W × D) in (mm)

Main1: 8-1/4 × 26-3/8 × 1-1/16 (210 × 670 × 26.6) Main2: 4-7/16 × 26-3/8 × 13/16 (112 × 670 × 20) Sub: 3-5/16 × 26-3/8 × 1/2 (84 × 670 × 13.3)

Fin pitch FPI

Man1: 21 Main2: 23 Sub: 18 Rows × Stages

Main1: 2 × 10 Main2: 2 × 7 Sub: 1 × 4

Pipe type Copper

Fin type Aluminum

Enclosure

Material Polystyrene

Color White

Approximate color of Munsell N 9.25/

Dimensions (H × W × D)

Net in (mm) 10-5/8 × 32-13/16 × 8-3/4 (270 × 834 × 222)

Gross 10-7/8 × 36 × 13-1/16 (277 × 914 × 332)

Weight Net

lb (kg) 22 (10)

Gross 29 (13)

Connection pipe Size Liquid

in (mm) Ø 1/4 (6.35)

Gas Ø 3/8 (Ø 9.52)

Method Flare

Drain hose Material PP+HDPE

Tip diameter in (mm) Ø17/32 (Ø 13.8) (I.D.), Ø19/32 to 21/32 (Ø 15.0 to 16.8) (O.D.)

Operation range Cooling °F (°C) 64 to 90 (18 to 32)

%RH 80 or less

Heating °F (°C) 60 to 86 (16 to 30)

Remote controller type Wireless (Wired, Mobile app*4 [FGLair] [option])

- 2 -

1. Specifications

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(7)

Type Wall mounted Inverter heat pump

Model name ASUH09LMAS ASUH12LMAS

NOTES:

• Specifications are based on the following conditions:

– Cooling: Indoor temperature of 80 °F (26.67 °CDB) /67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).

– Heating: Indoor temperature of 70 °FDB (21.11 °CDB) /60 °FWB (15.56 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) /43 °FWB (6.11 °CWB).

– *1: Heating (17 °F): Indoor temperature of 70 °FDB (21.11 °CDB) /60 °FWB (15.56 °CWB), and outdoor temperature of 17 °FDB (-8.33 °CDB) /15 °FWB (-9.44 °CWB).

– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)

• Protective function might work when using it outside the operation range.

• *2: Maximum current is maximum value when operated within the operation range.

• *3: Sound pressure level:

– Measured values in manufacturer’s anechoic chamber.

– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.

• *4: Available on Google Play store or on App Store®. Optional WLAN adapter is also required. For details, refer to the setting manual.

- 3 -

1. Specifications

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(8)

2. Dimensions

2-1. Models: ASUH09LMAS and ASUH12LMAS

Unit: in (mm)

32-13/16 (834)

10-5/8 (270)

8-3/4 (222)

1/8 (3.0) (32-13/16 [834])

13-9/16 (344) 14 (356)

12-7/8 (327) 4-7/16 (113)

12-7/8 (327) 2-5/8 (67)

2-7/16 (62)

1-15/16 (50) 3-5/16 (84)

1-11/16 (43) (10-5/8 [270])

1-11/16 (43)

Outline of indoor unit

for pipe inlet Ø 2-9/16 (65) for pipe inlet Ø 2-9/16 (65)

2-7/16 (62)

- 4 -

2-1. Models: ASUH09LMAS and ASUH12LMAS 2. Dimensions

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(9)

2-2. Installation space requirement

Provide sufficient installation space for product safety.

Unit: in (mm)

2 (50) or more 3 (71) or more

The flare connection part should be installed outdoors.

2 (40) or more 3 (70) or more

5 (107) or more

60 (1,500) or more

71 (1,800) or more

8 (183) or more Wall hook bracket

Outline of the indoor unit

- 5 -

2-2. Installation space requirement 2. Dimensions

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(10)

3. Wiring diagrams

3-1. Models: ASUH09LMAS and ASUH12LMAS

- 6 -

3-1. Models: ASUH09LMAS and ASUH12LMAS 3. Wiring diagrams

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(11)

4. Capacity table

Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR):

For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP)

4-1. Cooling capacity

¢ Model: ASUH09LMAS

AFR CFM 453

Indoor temperature

°FDB 64 70 75 80 85 90

°FWB 54 60 63 67 71 73

Outdoor temperature

°FDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP

kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW

14 8.34 5.55 0.20 9.30 6.19 0.20 10.26 6.82 0.21 10.57 7.04 0.20 11.21 7.46 0.20 11.85 7.89 0.21

23 7.95 5.29 0.22 8.86 5.90 0.22 9.78 6.51 0.22 10.08 6.71 0.22 10.69 7.11 0.22 11.30 7.52 0.22

32 7.57 5.04 0.22 8.43 5.61 0.22 9.31 6.19 0.22 9.59 6.38 0.22 10.17 6.77 0.22 10.74 7.15 0.22

41 7.18 4.78 0.22 8.00 5.32 0.22 8.83 5.88 0.23 9.10 6.06 0.22 9.64 6.42 0.22 10.19 6.78 0.23

50 6.80 4.52 0.20 7.56 5.03 0.20 8.36 5.56 0.21 8.61 5.73 0.21 9.12 6.07 0.21 9.63 6.41 0.22

59 6.41 4.85 0.20 7.13 4.85 0.21 7.88 5.29 0.21 8.12 5.73 0.21 8.60 5.70 0.21 9.08 6.07 0.22

67 8.53 5.29 0.40 9.52 5.32 0.40 10.47 5.80 0.41 10.82 6.28 0.41 11.46 6.24 0.41 12.11 6.65 0.42

77 8.02 5.29 0.46 8.94 5.32 0.47 9.86 5.83 0.47 10.17 6.28 0.48 10.78 6.24 0.48 11.40 6.65 0.49

87 7.54 5.12 0.51 8.39 5.15 0.52 9.25 5.60 0.53 9.52 6.04 0.53 10.10 6.04 0.54 10.68 6.41 0.55

95 7.10 4.98 0.57 7.92 5.02 0.58 8.73 5.46 0.58 9.00 5.90 0.58 9.55 5.87 0.59 10.07 6.24 0.59

104 5.90 4.64 0.46 6.59 4.67 0.47 7.27 5.08 0.48 7.47 5.49 0.48 7.95 5.46 0.49 8.39 5.83 0.49

115 4.20 3.28 0.35 4.67 3.31 0.35 5.12 3.62 0.36 5.29 3.89 0.36 5.60 3.86 0.37 5.94 4.13 0.37

AFR m3/h 770

Indoor temperature

°CDB 17.8 21.1 23.9 26.7 29.4 32.2

°CWB 12.2 15.6 17.2 19.4 21.7 22.8

Outdoor temperature

°CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP

kW kW kW kW kW kW

-10.0 2.44 1.63 0.20 2.72 1.81 0.20 3.01 2.00 0.21 3.10 2.06 0.20 3.29 2.19 0.20 3.47 2.31 0.21

-5.0 2.33 1.55 0.22 2.60 1.73 0.22 2.87 1.91 0.22 2.96 1.97 0.22 3.13 2.09 0.22 3.31 2.20 0.22

0.0 2.22 1.48 0.22 2.47 1.64 0.22 2.73 1.82 0.22 2.81 1.87 0.22 2.98 1.98 0.22 3.15 2.10 0.22

5.0 2.10 1.40 0.22 2.34 1.56 0.22 2.59 1.72 0.23 2.67 1.78 0.22 2.83 1.88 0.22 2.99 1.99 0.23

10.0 1.99 1.33 0.20 2.22 1.48 0.20 2.45 1.63 0.21 2.52 1.68 0.21 2.67 1.78 0.21 2.82 1.88 0.22

15.0 1.88 1.42 0.20 2.09 1.42 0.21 2.31 1.55 0.21 2.38 1.68 0.21 2.52 1.67 0.21 2.66 1.78 0.22

19.4 2.50 1.55 0.40 2.79 1.56 0.40 3.07 1.70 0.41 3.17 1.84 0.41 3.36 1.83 0.41 3.55 1.95 0.42

25.0 2.35 1.55 0.46 2.62 1.56 0.47 2.89 1.71 0.47 2.98 1.84 0.48 3.16 1.83 0.48 3.34 1.95 0.49

30.6 2.21 1.50 0.51 2.46 1.51 0.52 2.71 1.64 0.53 2.79 1.77 0.53 2.96 1.77 0.54 3.13 1.88 0.55

35.0 2.08 1.46 0.57 2.32 1.47 0.58 2.56 1.60 0.58 2.64 1.73 0.58 2.80 1.72 0.59 2.95 1.83 0.59

40.0 1.73 1.36 0.46 1.93 1.37 0.47 2.13 1.49 0.48 2.19 1.61 0.48 2.33 1.60 0.49 2.46 1.71 0.49

46.1 1.23 0.96 0.35 1.37 0.97 0.35 1.50 1.06 0.36 1.55 1.14 0.36 1.64 1.13 0.37 1.74 1.21 0.37

- 7 -

4-1. Cooling capacity 4. Capacity table

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(12)

¢ Model: ASUH12LMAS

AFR CFM 453

Indoor temperature

°FDB 64 70 75 80 85 90

°FWB 54 60 63 67 71 73

Outdoor temperature

°FDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP

kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW

14 11.25 7.76 0.33 12.53 8.65 0.33 13.80 9.53 0.35 14.23 9.82 0.34 15.08 10.41 0.34 15.93 11.00 0.35 23 10.66 7.36 0.37 11.87 8.19 0.38 13.08 9.03 0.40 13.49 9.31 0.39 14.30 9.87 0.39 15.10 10.42 0.40

32 10.07 6.95 0.40 11.21 7.74 0.40 12.36 8.53 0.42 12.74 8.79 0.41 13.51 9.33 0.41 14.27 9.85 0.42

41 9.47 6.54 0.40 10.56 7.29 0.40 11.64 8.04 0.42 12.00 8.28 0.41 12.73 8.78 0.41 13.44 9.27 0.43

50 8.88 6.13 0.39 9.90 6.84 0.39 10.92 7.54 0.41 11.25 7.77 0.40 11.94 8.24 0.40 12.60 8.70 0.41

59 8.29 6.35 0.40 9.25 6.38 0.41 10.20 6.96 0.42 10.51 7.51 0.42 11.16 7.47 0.42 11.77 7.98 0.43

67 11.43 7.47 0.65 12.73 7.51 0.66 14.06 8.19 0.67 14.47 8.84 0.68 15.35 8.80 0.68 16.21 9.38 0.69

77 10.82 7.13 0.75 12.04 7.17 0.76 13.27 7.85 0.77 13.68 8.46 0.77 14.50 8.43 0.78 15.32 8.97 0.79

87 10.10 6.99 0.85 11.26 7.03 0.86 12.39 7.68 0.87 12.80 8.29 0.88 13.55 8.26 0.88 14.30 8.77 0.89

95 9.49 6.69 0.93 10.58 6.72 0.94 11.63 7.34 0.96 12.00 7.92 0.96 12.73 7.88 0.97 13.44 8.39 0.98

104 8.05 6.35 0.87 8.97 6.38 0.89 9.89 6.96 0.90 10.20 7.51 0.91 10.78 7.51 0.92 11.40 7.98 0.92

115 5.66 5.15 0.69 6.28 5.19 0.70 6.93 5.63 0.71 7.17 6.11 0.71 7.57 6.07 0.72 8.02 6.48 0.73

AFR m3/h 770

Indoor temperature

°CDB 17.8 21.1 23.9 26.7 29.4 32.2

°CWB 12.2 15.6 17.2 19.4 21.7 22.8

Outdoor temperature

°CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP

kW kW kW kW kW kW

-10.0 3.30 2.28 0.33 3.67 2.53 0.33 4.05 2.79 0.35 4.17 2.88 0.34 4.42 3.05 0.34 4.67 3.22 0.35

-5.0 3.12 2.16 0.37 3.48 2.40 0.38 3.83 2.65 0.40 3.95 2.73 0.39 4.19 2.89 0.39 4.43 3.05 0.40

0.0 2.95 2.04 0.40 3.29 2.27 0.40 3.62 2.50 0.42 3.73 2.58 0.41 3.96 2.73 0.41 4.18 2.89 0.42

5.0 2.78 1.92 0.40 3.09 2.14 0.40 3.41 2.36 0.42 3.52 2.43 0.41 3.73 2.57 0.41 3.94 2.72 0.43

10.0 2.60 1.80 0.39 2.90 2.00 0.39 3.20 2.21 0.41 3.30 2.28 0.40 3.50 2.42 0.40 3.69 2.55 0.41

15.0 2.43 1.86 0.40 2.71 1.87 0.41 2.99 2.04 0.42 3.08 2.20 0.42 3.27 2.19 0.42 3.45 2.34 0.43

19.4 3.35 2.19 0.65 3.73 2.20 0.66 4.12 2.40 0.67 4.24 2.59 0.68 4.50 2.58 0.68 4.75 2.75 0.69

25.0 3.17 2.09 0.75 3.53 2.10 0.76 3.89 2.30 0.77 4.01 2.48 0.77 4.25 2.47 0.78 4.49 2.63 0.79

30.6 2.96 2.05 0.85 3.30 2.06 0.86 3.63 2.25 0.87 3.75 2.43 0.88 3.97 2.42 0.88 4.19 2.57 0.89

35.0 2.78 1.96 0.93 3.10 1.97 0.94 3.41 2.15 0.96 3.52 2.32 0.96 3.73 2.31 0.97 3.94 2.46 0.98

40.0 2.36 1.86 0.87 2.63 1.87 0.89 2.90 2.04 0.90 2.99 2.20 0.91 3.16 2.20 0.92 3.34 2.34 0.92

46.1 1.66 1.51 0.69 1.84 1.52 0.70 2.03 1.65 0.71 2.10 1.79 0.71 2.22 1.78 0.72 2.35 1.90 0.73

- 8 -

4-1. Cooling capacity 4. Capacity table

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(13)

4-2. Heating capacity

NOTE: Values mentioned in the table are calculated based on the maximum capacity.

¢ Model: ASUH09LMAS

AFR CFM 453

Indoor temperature

°FDB 60 65 70 72 75

Outdoor temperature

°FDB °FWB TC IP TC IP TC IP TC IP TC IP

kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW

-15 -17 5.77 1.24 5.62 1.27 5.47 1.29 5.32 1.31 5.17 1.33

-5 -7 8.07 1.32 7.86 1.34 7.65 1.37 7.44 1.39 7.23 1.41

5 3 9.46 1.23 9.21 1.25 9.48 1.28 8.72 1.30 8.47 1.33

14 12 10.52 1.31 10.25 1.33 9.97 1.36 9.69 1.39 9.42 1.41

23 19 12.38 1.38 12.05 1.41 11.73 1.44 11.41 1.47 11.08 1.50

32 28 14.06 1.49 13.69 1.52 13.32 1.55 12.95 1.58 12.59 1.61

41 37 15.56 1.58 15.15 1.62 14.75 1.65 14.34 1.68 13.93 1.71

47 43 16.89 1.60 16.44 1.63 16.00 1.67 15.56 1.70 15.12 1.73

50 47 16.97 1.62 16.53 1.65 16.09 1.69 15.64 1.72 15.20 1.75

59 50 17.15 1.53 16.70 1.56 16.25 1.59 15.80 1.62 15.36 1.65

68 59 16.18 1.19 15.76 1.21 15.33 1.24 14.91 1.26 14.48 1.29

75 64 16.71 1.25 16.27 1.27 15.83 1.30 15.40 1.32 14.96 1.35

AFR m3/h 770

Indoor temperature

°CDB 15.6 18.3 21.1 22.2 23.9

Outdoor temperature

°CDB °CWB TC IP TC IP TC IP TC IP TC IP

kW kW kW kW kW

-26.1 -27.0 1.69 1.24 1.65 1.27 1.60 1.29 1.56 1.31 1.51 1.33

-20.6 -21.7 2.37 1.32 2.30 1.34 2.24 1.37 2.18 1.39 2.12 1.41

-15.0 -16.1 2.77 1.23 2.70 1.25 2.78 1.28 2.55 1.30 2.48 1.33

-10.0 -11.1 3.08 1.31 3.00 1.33 2.92 1.36 2.84 1.39 2.76 1.41

-5.0 -7.2 3.63 1.38 3.53 1.41 3.44 1.44 3.34 1.47 3.25 1.50

0.0 -2.2 4.12 1.49 4.01 1.52 3.90 1.55 3.80 1.58 3.69 1.61

5.0 2.8 4.56 1.58 4.44 1.62 4.32 1.65 4.20 1.68 4.08 1.71

8.3 6.1 4.95 1.60 4.82 1.63 4.69 1.67 4.56 1.70 4.43 1.73

10.0 8.3 4.97 1.62 4.84 1.65 4.71 1.69 4.58 1.72 4.45 1.75

15.0 10.0 5.03 1.53 4.90 1.56 4.76 1.59 4.63 1.62 4.50 1.65

20.0 15.0 4.74 1.19 4.62 1.21 4.49 1.24 4.37 1.26 4.25 1.29

24.0 18.0 4.90 1.25 4.77 1.27 4.64 1.30 4.51 1.32 4.38 1.35

¢ Model: ASUH12LMAS

AFR CFM 453

Indoor temperature

°FDB 60 65 70 72 75

Outdoor temperature

°FDB °FWB TC IP TC IP TC IP TC IP TC IP

kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW

-15 -17 6.52 1.24 6.35 1.27 6.18 1.29 6.01 1.31 5.84 1.33

-5 -7 9.12 1.32 8.88 1.34 8.65 1.37 8.41 1.39 8.17 1.41

5 3 11.29 1.23 11.00 1.25 10.70 1.28 10.40 1.30 10.11 1.33

14 12 12.56 1.31 12.23 1.33 11.90 1.36 11.57 1.39 11.24 1.41

23 19 14.77 1.38 14.39 1.41 14.00 1.44 13.61 1.47 13.23 1.50

32 28 16.78 1.49 16.34 1.52 15.90 1.55 15.46 1.58 15.02 1.61

41 37 18.57 1.58 18.09 1.62 17.60 1.65 17.11 1.68 16.63 1.71

47 43 20.16 1.60 19.63 1.63 19.10 1.67 18.57 1.70 18.04 1.73

50 47 20.26 1.62 19.73 1.65 19.20 1.69 18.67 1.72 18.14 1.75

59 50 20.47 1.53 19.94 1.56 19.40 1.59 18.86 1.62 18.33 1.65

68 59 19.31 1.19 18.81 1.21 18.30 1.24 17.79 1.26 17.29 1.29

75 64 19.94 1.25 19.42 1.27 18.90 1.30 18.38 1.32 17.86 1.35

AFR m3/h 770

Indoor temperature

°CDB 15.6 18.3 21.1 22.2 23.9

Outdoor temperature

°CDB °CWB TC IP TC IP TC IP TC IP TC IP

kW kW kW kW kW

-26.1 -27.0 1.91 1.24 1.86 1.27 1.81 1.29 1.76 1.31 1.71 1.33

-20.6 -21.7 2.67 1.32 2.60 1.34 2.53 1.37 2.46 1.39 2.39 1.41

-15.0 -16.1 3.31 1.23 3.22 1.25 3.14 1.28 3.05 1.30 2.96 1.33

-10.0 -11.1 3.68 1.31 3.58 1.33 3.49 1.36 3.39 1.39 3.30 1.41

-5.0 -7.2 4.33 1.38 4.22 1.41 4.10 1.44 3.99 1.47 3.88 1.50

0.0 -2.2 4.92 1.49 4.79 1.52 4.66 1.55 4.53 1.58 4.40 1.61

5.0 2.8 5.44 1.58 5.30 1.62 5.16 1.65 5.02 1.68 4.87 1.71

8.3 6.1 5.91 1.60 5.75 1.63 5.60 1.67 5.44 1.70 5.29 1.73

10.0 8.3 5.94 1.62 5.78 1.65 5.63 1.69 5.47 1.72 5.32 1.75

15.0 10.0 6.00 1.53 5.84 1.56 5.69 1.59 5.53 1.62 5.37 1.65

20.0 15.0 5.66 1.19 5.51 1.21 5.36 1.24 5.22 1.26 5.07 1.29

24.0 18.0 5.85 1.25 5.69 1.27 5.54 1.30 5.39 1.32 5.23 1.35

- 9 -

4-2. Heating capacity 4. Capacity table

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(14)

5. Fan performance

5-1. Air velocity distributions

¢ Models: ASUH09LMAS and ASUH12LMAS

Measuring conditions Fan speed Operation mode

HIGH FAN

Top view

Vertical airflow direction louver: Up Horizontal airflow direction louver: Center

(m)

(m)

3 2 1 0 1 2 3

0 1 2 3 4 5 6 7 8 9 10

7 10 (ft)

3 13 16 20 23 26 30 33

10 7 3 0 3 7 10

(ft) Unit: ft/s (m/s)

7 (2) 3 (1) 2 (0.5)

0

Top view

Vertical airflow direction louver: Up Horizontal airflow direction louver: Left & Right

(m)

(m)

3 2 1 0 1 2 3

0 1 2 3 4 5 6 7 8 9 10

10 7 3 0 3 7 10

(ft)

7 (2)

7 (2)

3 (1) 3 (1)

2 (0.5)

2 (0.5) Unit: ft/s (m/s)

7 10 (ft)

3 13 16 20 23 26 30 33

0

Side view

Vertical airflow direction louver: Up Horizontal airflow direction louver: Center

(m)

(m)

3

2

1

0

0 1 2 3 4 5 6 7 8 9 10

10

7

3

0

(ft)

7 (2)

3 (1) 2 (0.5)

Unit: ft/s (m/s)

7 10 (ft)

3 13 16 20 23 26 30 33

0

Side view

Vertical airflow direction louver: Down Horizontal airflow direction louver: Center

(m)

(m)

3

2

1

00 1 2 3 4 5 6 7 8 9 10

10

7

3

0

(ft)

7 (2)

3 (1)

2 (0.5) 2 (0.5)

Unit: ft/s (m/s)

7 10 (ft)

3 13 16 20 23 26 30 33

0

- 10 -

5-1. Air velocity distributions 5. Fan performance

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(15)

5-2. Airflow

¢ Model: ASUH09LMAS

Cooling

Fan speed Airflow

HIGH

m3/h 770

l/s 214

CFM 453

MED

m3/h 600

l/s 167

CFM 353

LOW

m3/h 450

l/s 125

CFM 265

QUIET

m3/h 250

l/s 69

CFM 147

Heating

Fan speed Airflow

HIGH

m3/h 770

l/s 214

CFM 453

MED

m3/h 640

l/s 178

CFM 377

LOW

m3/h 520

l/s 144

CFM 306

QUIET

m3/h 310

l/s 86

CFM 182

- 11 -

5-2. Airflow 5. Fan performance

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(16)

¢ Model: ASUH12LMAS

Cooling

Fan speed Airflow

HIGH

m3/h 770

l/s 214

CFM 453

MED

m3/h 600

l/s 167

CFM 353

LOW

m3/h 450

l/s 125

CFM 265

QUIET

m3/h 250

l/s 69

CFM 147

Heating

Fan speed Airflow

HIGH

m3/h 770

l/s 214

CFM 453

MED

m3/h 640

l/s 178

CFM 377

LOW

m3/h 520

l/s 144

CFM 306

QUIET

m3/h 310

l/s 86

CFM 182

- 12 -

5-2. Airflow 5. Fan performance

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(17)

6. Operation noise (sound pressure) 6-1. Noise level curve

¢ Models: ASUH09LMAS and ASUH12LMAS

Cooling

Octave band sound pressure level, dB: (0 dB=0.0002 µbar)

Octave band center frequency, Hz

80

70

60

50

40

30

20

10

0

63 125 250 500 1,000 2,000 4,000 8,000

NC-65

NC-60

NC-55

NC-50

NC-45

NC-40

NC-35

NC-30

NC-25

NC-20

NC-15 HIGH

QUIET

Heating

Octave band sound pressure level, dB: (0 dB=0.0002 µbar)

Octave band center frequency, Hz

80

70

60

50

40

30

20

10

0

63 125 250 500 1,000 2,000 4,000 8,000

NC-65

NC-60

NC-55

NC-50

NC-45

NC-40

NC-35

NC-30

NC-25

NC-20

NC-15 QUIET

HIGH

6-2. Sound level check point

32 in (0.8 m)

40 in (1 m)

Microphone Microphone

NOTE: Detailed shape of the actual indoor unit might be slightly different from the one illustrated above.

- 13 -

6-1. Noise level curve 6. Operation noise (sound pressure)

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(18)

7. Safety devices

Type of protection Protection form Model

ASUH09LMAS and ASUH12LMAS

Circuit protection Current fuse (PCB*) 250 V, 3.15 A

Fan motor protection Power IC thermal shutdown protection

Activate 257±18°F (125±10°C)

Fan motor stop

Reset 212±18°F (100±10°C)

Fan motor restart

*PCB: Printed Circuit Board

- 14 -

7. Safety devices

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(19)

8. External input and output

Rotary switch SW302

CN308 SW301

External input and output PCB Indoor unit PCB

CN314

CN313

CN312 CN311 CN310 CN65

(Ext. in/out PCB)

CN47 (Ext. out) CN46 (Ext. in)

PCB External input External output Connector Input select Input signal

Indoor unit

Operation/Stop

- CN46 Dry contact Edge

Forced stop

-

Operation status

CN47 - -

Error status Indoor unit fan operation status Cooling thermostat On

Heating thermostat On

External heater output

External input and output (UTY-

XCSXZ2)

Operation/Stop

-

CN313/

CN314 Dry contact/

Apply voltage

Edge/Pulse Forced stop

Forced thermostat off CN313 Edge

-

Operation status

CN310/

CN311/

CN312

- -

Error status Indoor unit fan operation status External heater output

Remote controller output

Cooling high/low output

Heating thermostat On

8-1. External input

With using external input function, some functions on this product can be controlled from an external device.

• “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit.

• A twisted pair cable (22AWG) should be used. Maximum length of cable is 492 ft (150 m).

• The wire connection should be separate from the power cable line.

- 15 -

8-1. External input 8. External input and output

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(20)

¢ Indoor unit

Indoor unit functions such as Operation/Stop can be done by using indoor unit connectors.

1 2 3

 Connector

(CN46) PCB





Connected unit

*1: The switch can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.

- 16 -

8-1. External input 8. External input and output

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(21)

¢ External input and output PCB

The indoor unit Operation/Stop can be set by using the input connector on the PCB.

• Input select:

Use either one of these types of connectors according to the application. (Both types of connec- tors cannot be used simultaneously.)

– Dry contact

In case of internal power supply, set the slide switch of SW301 to "NON VOL" side.

1 2 Input 1 3

PCB Connected unit

*

+

-

1 2 Input 2 3

*

+

-

Connector (CN313)

Connector (CN314)

*1: The switches can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.

– Apply voltage

In case of external power supply, set the slide switch of SW301 to "VOL" side.

1 2 Input 1 3

Power supply

PCB Connected unit

*

*

*2 + -

1 2 3 Input 2

Connector (CN313)

Connector (CN314)

*1: The switches can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.

*2: Make the power supply DC 12 to 24 V, 10 mA or more.

- 17 -

8-1. External input 8. External input and output

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(22)

8-2. External output

Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed.

¢ Indoor unit

• A twisted pair cable (22AWG) should be used. Maximum length of cable is 82 ft (25 m).

• Output voltage: High DC 12 V ± 2 V, Low 0 V.

• Permissible current: 50 mA

• For details, refer to "Combination of external input and output" on page 20.

When indicator or other components are connected directly

Example: Function setting 60 is set to "00"

1 2

Connector (CN47) LED

PCB Resistor

Connected unit

+ -

When connecting with a device equipped with a power supply

Example: Function setting 60 is set to "00"

1 2

Connected device Connector

(CN47) PCB

Connected unit Relay

(Operation status) -

+

- 18 -

8-2. External output 8. External input and output

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

(23)

¢ External input and output PCB

• A twisted pair cable (22AWG) should be used. Maximum length of cable is 82 ft (25 m).

• Output voltage: High DC 12 V±2 V, Low 0 V.

• Permissible current: 50 mA

• For details, refer to "Combination of external input and output" on page 20.

• When indicator or other components are connected directly:

Example: Rotary SW on External input and output PCB is set to “1”.

1 2

Connector (CN310) LED 1

(Operation status)

PCB Resistor

Connected unit

+ -

1 2

Connector (CN311) LED 2

(Error status)

Resistor

+ -

1 2

Connector (CN312) LED 3

(Indoor unit fan operation status)

Resistor

+ -

• When connecting with a device equipped with a power supply:

Example: Rotary SW on External input and output PCB is set to “1”.

1 2

Connected device 1 Connector

(CN310) PCB

Connected unit Relay

(Operation status) -

+

1 2

Connected device 2 Connector

(CN311)

(Error status) -

+

1 2 Connected device 3

Connector (CN312) (Indoor unit fan

operation status) -

+

- 19 -

8-2. External output 8. External input and output

WALL MOUNTED ASUG09-12LMAS WALL MOUNTED ASUG09-12LMAS

References

Related documents

When the Return water temperature is equal or less than Parameter 0 (default setting 2°C) AND the ambient air temperature is equal or less than 0°C) the Heat Pump and circulating

If the outdoor temperature data are not being received within three minutes after setting up (or “- -. -” is shown in the outdoor temperature section of the Projection alarm

Important Solar Benefits  Rising electric costs are avoided.  Solar costs less up front,

Energy Transfer by Heating Heating and Insulating Buildings Energy Transfers and Efficiency Transferring Electrical Energy Generating Electricity The National Grid

With her poor flowers she stood as in a dream. Into her basket hungry eyes

Excellent product as optibond plus export package to keep your order, dental health experts strive their patients happy and a quality materials.. Play a number to solo plus

"When we were dead in our trespasses, God made us alive together with Christ, nailing the record of our sins to the cross." Jesus says to us, + "Your sins

Metrohm IC systems will be a feature of the fi ve new steam- electric power units at the Linkou Thermal Power Plant and the Talin Thermal Power Plant, analyzing water at various