As the key member of CIRC and the pioneer of isotope industry in China, Chengdu Gaotong Isotope Co., Ltd.(CNNC), commonly known as Gaotong, specializes in research & development, production and distribution of radiopharmaceuticals and sealed radioactive sources. It is the major supplier of diagnostic and therapeutic radiopharmaceuticals and sealed radioactive sources for both medical and industrial purposes in China. Gaotong first developed Cobalt-60 Teletherapy Sources, Cobalt-60 Industrial Radiation Sources and Cobalt-60 Gamma-knife Sources in China and first built 131I dry-process production facilities in China and Gel-type 99mTc Generator production facility in the world. Gaotong has dozens of radioisotope production facilities which provides the customer with various high-quality radiopharmaceuticals and sealed radioactive sources, as well as NDT Equipment and Stereotactic Gamma-ray Radio-surgery System. Meanwhile, Gaotong provides the customers with transport of radioactive materials, on-site replacement of radioactive sources, recycle of spent sources, import-export, etc..
About Us
China Isotope & Radiation Corporation (CIRC), a subsidiary of China National Nuclear Corporation(CNNC), specializes in nuclear technology application industry and becomes the leader in the field of radioisotopes and radiation technology application in China. CIRC is the biggest manufacturer of imaging diagnostic and therapeutic Radiopharmaceuticals, Urea Breath Test Kits & Analyzers and Radioimmunoassay kits, and sealed radioactive sources for both medical and industrial purposes in China; a qualified EPC (Engineering, Procurement, Construction) supplier of irradiation facilities approved by Ministry of Ecology and Environment of China; a reputable service provider for independent medical laboratories of the Chinese hospitals and other medical institutes.
I
Gel: type
99Mo-
99"'Tc Generator
Gel-type generator ""Mof"mTc produces sterile solution of sodium pertechnetate [ Na00"Tc04]. Mother
nuclide 00
Mo in the form of ZrO""MoQ4 gel is filled in generator column. Daughter nuclide """Tc reaches
equilibrium with i;gMo after about 23 hours and can be washed from the column with saline. Sodium pertechnetate [ Na00mTC0
4] can be used directly for diagnostics or for labeling of radiopharmaceutical kits. Nuclear data ""Mo T,a: 66.0h 'Y Energy: 0.14MeV � Energy: 1.214MeV T,a: 6.02h 'Y Energy: 0.14MeV Technical parameter Eluate Assay of 99Mo: < 0.1 %
Radiochemical purity: >Na00"Tc0 4 98% Zr content, < 8.0 1-1 g/ml
pH: 4.0- 7.0 Generator
Elution yields: 70%
Expiration: 1 Sdays after production Weight: 39 kg
Specifications
18.SGBq; 29.6GBq; 37GBq
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
R
adiopharmaceuticals
I
Str�ntium[
89
Sr ] Chloride Injection
Strontium t'Sr ] Chloride injection is used for palliative treatment of bone pain in patients with metastases from carcinomas of the prostatic gland and mammary gland. The most frequent indication for Strontium[""Sr] Chloride therapy are multiple spread metastases in patients formerly treated with conventional therapeutic methods in which no pain relief response was obtained.
Nuclear data
� Energy: 1.49MeVTechnical parameter
Radionuclidic purity: > 99.9% Radioactive concentration: ;:,:37MBq/mL Sr content : ,:;;; 12 .Sm g/m L Al content: ,s;2µg/ m L pH: 4.0 -7.5Expiration: 30 days after production
Specifications
111MBq; 148MBq; 222MBq; 296MBq
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
R
adiopharmaceuticals
I
So�um Iodide
C
'
1I] Oral Solution
Sodium iodide ['3
' I] oral solution is used for diagnosis and treatment of thyroid gland disease or for
preparing 131 1 labeled radiopharmaceuticals.
Nuclear data
T 112: 8.04d y Energy: 0.365MeV 13 Energy: 0.606MeVTechnical parameter
Radionuclidic purity:> 99.9% Radiochemical purity: :;:,:95% Radioactive concentration: :;:,: 185MBq/mL pH: 7.0- 9.0Expiration: 24 days after production
Specifications
925MBq ; 1850MBq; 3700MBq; 7400MBq
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
R
adiopharmaceuticals
I
So+um Iodohippurate [
131
1) Injection
Sodium lodohippurate ['311] Injection is used for kidney and urinary system function test.
Nuclear data:
T 112: 8.04d 'Y Energy: 0.365MeV 13 -Energy: 0.606MeVTechnical parameter
Radionuclidic purity, >99.9% Radiochemical purity, ?!95% Radioactive concentration: ?!37MBq/m L pH: 5.0-6.0Expiration: 16 days after production
Specifications
37MBq: 111MBq: 185MBq; 370MBq
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
R
adiopharmaceuticals
I
Cob�lt
-
60 Gamma-
knife Source
Use: Non-invasive treatment of cerebral tumors or other parts' tumors.
Nuclear data:
Half-life: 5.27years
'Y energy: 1.17MeV, 1.33MeV
13 energy: 0.318MeV
Uncertainty of radioactivity:
�
±10%
Safety performance: E63535 or C63535
Leakage and contamination: GB15849-1995
Radioactive material:
<l)1 x 1mm nickel-plated Cobalt-60 pellets
Structure: Double-encapsulated structure sealed by argon-arc welding
Specifications of Cobalt-60 Gamma-knife Source
Source pieces perCobalt-00 Gamma
42
40
18
Knife TI1erapy SourceActivity per single
5.29
12.60
10.30
source, 1bq
Total activity, TBq
222.18
504.00
185.40
18
30
30
25
13.30
10.36
7.40
9.60
239.40
310.80
222.00
240.00
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed R
a
dioactive Sources
I
Co�alt-60 Teletherapy Source
Use: Teletherapy of galactophore, liver, kedney tumors, etc .. Nuclear data:
Half-life: 5.27years
'Y energy:1.17MeV, 1.33MeV � -energy:0.318MeV
Uncertainty of radioactivity: � ± 10 %
Safety performance: E63535
Leakage and contamination: GB15849-1995
Radioactive material:(!>1 x 1mm nickel-plated Cobalt-60 pellets.
Structure: Double-encapsulated structure sealed by argon-arc welding.
Specifications of Cobalt-60 Teletherapy Source
Serial Number External Dimensions, mn
1 (!>26 x 27
2 (!>23 x 33
3 <1>23.4 x 36.7
Max. Dimensions of Content Activity, TBq
Active Part, mm
<1>22 x 20 111 -222 <I> 19 x 25 111 - 222 <I> 19.5 x 28.5 111 - 296
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed R
a
dioactive Sources
I
Co�alt-60 Non-Destructive Testing Source
Use: Non-destructive testing of metallic and nonmetallic material.Nuclear data:
Half-life: 5 .27years;
y energy: 1.1 ?MeV, 1.33MeV
13 ·
energy: 0.318MeV.Uncertainty of radioactivity: �
±
10%Safety performance: C63535
Leakage and contamination: GB15849-1995
Radioactive material: ct> 1
x
1 mm nickel-plated Cobalt-60 pelletsStructure: Double-encapsulated structure sealed by argon-arc welding
Tablel Optin1um Test Thickness
MaLeiial Steel
Optimum Test Thickness
50-150 mm
Light alloy
150-450mm
�
Tab
l
e2 Specifications of Cobalt-60 Non-
D
estructive Testing Source
Serial Number External Dimensions(mm)1
<1>7.3 x 17
�
2
<1>7.5 x 21
3 �, ...
<1>7.5 x 25
Dimensions of Active Patt(mm) Equivalent Activity(TBq)
<1>2 x 3
<1>2 x 3
<1>4x4
0. 55-3.7
<1>4x4
0.55-3.7
<1>4x8
7.4
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed R
a
dioactive Sources
I
Co�alt-60 Level-inspecting Source
Use: Inspecting liquid or solid level in a sealed container.
Nuclear data:
Half-life: 5. 27years
y energy: 1.1 ?MeV, 1.33MeV �·energy: 0.318MeV
Uncertainty of radioactivity: �
±
10% Safety performance: C43313Leakage and contamination: GB15849-1995 Radioactive material: Ni-Co("°Co) alloy
structure: Ni-Co(""Co) alloy wire fixed onto stainless steel rod and sealed in stainless steel capsule
by argon-arc welding.
Specifications of Cobalt
-
60 Level-inspectin
g
Source
Serial No. Outside Diameter, mml
4>7 - 8
2
4>7 - 8
Length, mm Equivalent Activity, GBq 500 -1000 1.85 -5.55
1000-2000 5.55 -11.l
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed R
a
dioactive Sources
I
Iri�um-192 Non-Destructive Testing Source
Use: Non-destructive testing of metallic and non-metallic material.Nuclear data:
Half-life:7 4.2 days
y energy: 0.296MeV, 0.612MeV
Jl ·
energy: 0.675MeV, 0.539MeVUncertainty of radioactivity: �
±
10% Safety performance: C64344Leakage and contamination: GB 1584� 1995. Radioactive material: lridium-192 metallic discs.
structure: Single-encapsulated structure sealed by argon-arc welding.
Table! Optimum Test Thickness
Material Steel Light alloy
Optimum Test Thickness 12.5-62.5 nun 40-190 mm
Other mate1iaJ
10-50 g/cm2
Table2 Specifications of Iridium-192 Non-Destructive Testing Source
External Dimensions, mm Dimensions of Active Part, nun Equivalent Activity ,TBq
<1>5 x 8 <1>3 x 2.6
I
<1>3 x 2.8 3.7Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed
Ra
dioactive Sources
Galt-60 Brachytherapy Source
Use: Brachytherapy of cervices, esophagus, rectum tumors, etc .. Nuclear data:Half-life: 5.27years
'Y energy: 1.17MeV, 1.33MeV � energy: 0.318MeV
Uncertainty of radioactivity: �
±
10% Safety performance: C53211Leakage and contamination: GB 1584� 1995
Radioactive material: cJJ 1 X 1 mm nickel-plated Cobalt-60 pellets. Structure: Single-encapsulated structure sealed by argon-arc welding.
Specifications of Cobalt-60
B
rachytherapy Source
SeriaJ umber External Dimensions, mm1
<I> 2.5 x 8.0
2
<I> 1.5 x 3.5
Activity, GBq
22.2
33.3
44.43.7
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed
R
a
dioactive Sources
I
Cob�lt-60/Cesium-137 Blood Irradiation Source
Use: Inactivating immunocompetent lymphocyte of blood. Nuclear data:
Cobalt-60:
Half-life: 5.27years
'Y energy: 1 .1 ?MeV, 1.33MeV 13 · energy: 0.318MeV
Cesium-137:
H alf-1 ife: 33 years; 'Y energy: 0.661MeV Uncertainty of radioactivity: �
±
10% Safety performance: E635 35Leakage and contamination: GB 1584� 1995
Radioactive material: Nickel-plated Cobalt-60 pellets or Cesium-137 metallic material. Structure: Double-encapsulated structure sealed by argon-arc weldi ng.
Specifications of Cobal
t
-60/Cesium
-
l
3
7 Blood Irradiatio
n
Source
Serial number External Dimensions, mm Max. Dimensions of Active Patts, mm EquivalentActivity,IBq
1 <1>26 x 27 2 <1>38 x 48.5 3 <1>38 x 110 <1>22 x 20 22.2-37 <1>33 x 40 48.1 <1>33 x 80 96.2
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed R
a
dioactive Sources
Galt-60 Industrial Gauge Source
Use: Being equipped with industrial gauges. Nuclear data:
Half-life:5.27years
'Y energy: 1.1 ?MeV, 1.33MeV
13 ·
energy: 0.318MeVUncertainty of radioactivity: �
±
10%Safety performance: C53211
Leakage and contamination: GB15849-1995
Radioactive material: Nickel-plated Cobalt-60 pellets
Structure: double-encapsulated structure sealed by argon-arc welding.
Specifications of
C
obalt
-
60 Industrial Gauge Source
External Dimensions, mm Dimensions of Active Parts, mm Equivalent Activity,GBq
<l>5x8 <l>lx2
I
<l>2 x 2 3.7-185Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
S
ealed
R
a
dioactive Sources
Cobalt-60 main parameters
:
Model Radioactive source Max. loaded activity Weight Transmission thickness(Fe) Surface dose Cobalt-60 Co-60 100Ci 156Kg 30-250mm <200mr/h Cobalt-60A Co-60 200Ci 206Kg 30-250mm <200mr/hCobalt-60 detector and accessories
:
Co-60 detector Cable & rack Source guide tube Tripod Crank Source terminal Source pig tail Fast connector
Co
balt
-60 Gamma-ray Flaw
Detector
(NDT Equipment)
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
I
ridium
-192
main parameters
:
Model Radioactive source Max. loaded activity Weight Transmission thickness(Fe) Surface dose IR-192 Ir-192 100Ci 18Kg 10-80mm <200mr/h IR-192A Ir-192 200Ci 20Kg 10-80mm <200mr/h IR-192B Ir-192 150Ci 19Kg 10-80mm <200mr/h Operation distance Source focus Output range 10-15 meters Ø3ר3 5-10 metersI
ridium
-192 detector and accessories
:
Ir-192 detector Cable & rack Source guide tube Tripod
Crank Source terminal Source pig tail Fast connector
Ir
idium
-
192
Gamma-ray Flaw
Detector
(NDT Equipment)
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
Se
lenium
-75 main parameters
:
Model Radioactive source Rated loaded activity Weight Transmission thickness(Fe) Surface dose Se-75 Se-75 100Ci9Kg 4-30mm ≤10mR/h Operation distance Source focus Output range 10-15meters Ø3ר3 5-10 meters
Se
lenium
-75
detector and accessories
:
Se-75 detector Cable & rack Source guide tube Tripod
Crank Source terminal Source pig tail Fast connector
Selenium
-
75
Gamma-ray Flaw
Detector
(NDT Equipment)
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China.
Tel./Fax: (028)85904073, 85904574
N
on-destructive Testing
Sources
at 1 meter from the detector ≤2mR/h
Address: Room 6, Floor3, Building 2, No. 25 Nansan Sect., Erhuan Road, Chengdu, China. Tel./Fax.: (028)85904073, 85904574
E-mail: [email protected] URL: www.cngt.com.cn