The Composite Structural Insulated Panel (C-SIP) System Connection Details are listed below:
•
Continuous fiberglass reinforced thermoset (FRT) 4" x 1-3/8" x 3/16" Bedford Composite Channels are
used instead of lumber for the top and bottom plate - replacing all wood components susceptible to rot,
mold and moisture penetration.
•
The H-Stud panel connection, made of the high performance FRT composite material in the 3-1/2" x
1-1/2" x 3/16" Bedford Channel, joins the C-SIP wall panels together with a structural stud.
•
The H-Stud is installed between the adjacent C-SIP wall panels with ITW Buildex 10-16 x 1-13/16"
Fasteners self-tapping flush head screws – spaced as required by engineering specifications.
•
The 1/4" gap between panels is then filled with 3M's 4000UV Adhesive Sealant that bonds the C-SIP
skins together.
•
The complete joint is then covered with 4″ wide 3M 8067 All Weather Flashing tape. This flashing tape
is also used around all wall penetrations creating an air and water tight joint over the H-Stud connection.
•Windows are mounted onto the C-SIP exterior skin with fasteners that screw into the 4" FRT channel
running continuously inside the rough window opening.
•
The same high performance 4″ inch wide 3M all weather flashing tape covers the window nailing
flange – creating an air and water tight bond with the C-SIP wall panel skin.
This innovative combination of advanced FRT composite skins and the high insulating polyurethane
foam core – R-26 in a 4-1/2 inch thick panel – delivers the performance that homeowners, architects,
apartment and building owners demand and need to protect their long term investments.
264 Reynoldsdale Road, Bedford, PA 15522-7401 Phone: 814-623-8125
Sales Fax: 814-623-6032 www.bedfordplastics.com E-mail: frpsales@bedfordplastics.com 6/2007 4-7
4 X 1 3/8 X 3/16 CHANNEL
101.6 x 34.9 x 4.8 CHANNEL
ALLOWABLE UNIFORM LOADS (lbs./ft. /
N/m.
)
Laterally Supported
A
w= 0.680 in.
2/
438.7mm
2Wt. = 0.88 lbs./ft. /
1.31kg/m.
I = 2.62 in.
4/
1090526mm.
4S = 1.31 in.
3/
21467mm.
3This item is stocked in 20-foot lengths in Standard Polyester (ST) and Polyester Fire Retardant (FR). Other lengths available in mill run quantities.
The mill run on this item is 1,000 feet.
Orders for less than mill run quantities will be subject to set up charges as well as premium per foot cost.
L/100
L/150
L/180
L/240
L/360
3/
0.91 435/6343
Fv ----/
---- ----/
---- ----/
---- ----/
---- 296/
4322 4/
1.22 244/
3562 Fv ----/
---- ----/
---- ----/
---- 211/
3086 141/
2053 5/
1.52 156/
2275 Fb ----/
---- ----/
---- 153/
2237 115/
1675 76/
1112 6/
1.83 108/1576
Fb ----/
---- ----/
---- 92/
1336 68/
999 45/
662 7/
2.13 79/
1154 Fb ----/
---- 71/
1029 59/
855 44/
638 29/
421 8/
2.44 60/
881 Fb ----/
---- 48/
695 40/
577 29/
430 19/
282 9/
2.74 48/693
Fb ----/
---- 34/
490 28/
406 21/
301 13/
196 10/
3.05 38/559
Fb 37/
540 24/
356 20/
295 15/
218 10/
141 The part weight has been deducted in the above table. English/MetricSPAN
FT/m MAXIMUM LOAD
264 Reynoldsdale Road, Bedford, PA 15522-7401 Phone: 814-623-8125
Sales Fax: 814-623-6032 www.bedfordplastics.com E-mail: frpsales@bedfordplastics.com 6/2007 4-5
3 1/2 X 1 1/2 X 3/16 CHANNEL
88.9 x 38.1 x 4.8 CHANNEL
ALLOWABLE UNIFORM LOADS (lbs./ft. /
N/m
.
)
Major Axis
********Laterally Supported **********
A
w(in.
2/
mm.
2)=0.54 /
348.3
Wt.(lbs./
kg/m
)=0.86 /
1.28
I(in.
4/
mm.
4)= 1.92 /
799164
S(in.
3/
mm.
3)= 1.10 /
18026
Minor Axis
********Laterally Supported **********
A
w(in.
2/
mm.
2)=0.44 /
283.9
Wt.(lbs./
kg/m
)=0.86 /
1.28
I(in.
4/
mm.
4)=0.22 /
91571
S(in.
3/
mm.
3)=0.21 /
3441
This item is stocked in 20-foot lengths in Standard Polyester (STD) and Polyester Fire Retardant (FR). Other lengths available in mill run quantities.
The mill run on this item is 1,000 feet.
Orders for less than mill run quantities will be subject to set-up charges as well as premium per foot cost.
SPAN MAXIMUM DEFLECTION
FT/m LOAD L/100 L/150 L/180 L/240 L/360 3
/
0.91 298/
4353 Fv ----/
---- ----/
---- ----/
---- ----/
---- 221/
3228 4/
1.22 167/
2442 Fv ----/
---- ----/
---- ----/
---- 157/
2286 104/
1519 5/
1.52 107/
1558 Fb ----/
---- ----/
---- ----/
---- 84/
1233 56/
817 6/
1.83 74/
1077 Fb ----/
---- ----/
---- 67/
980 50/
731 33/
483 7/
2.13 54/
788 Fb ----/
---- 52/
753 43/
625 32/
465 21/
305 8/
2.44 41/
600 Fb ----/
---- 35/
506 29/
419 21/
311 14/
202 9/
2.74 32/
471 Fb ----/
---- 24/
355 20/
293 15/
216 10/
139 10/
3.05 26/
378 Fb ----/
---- 18/
256 14/
211 11/
155 7/
98 11/
3.35 21/
310 Fb 20/
292 13/
190 11/
156 8/
113 5/
71 12/
3.66 18/
258 Fb 15/
223 10/
144 8/
117 6/
84 4/
51SPAN MAXIMUM DEFLECTION
FT/m LOAD L/100 L/150 L/180 L/240 L/360
3
/
0.91 154/
2245 Fb 115/
1683 77/
1117 64/
928 47/
693 31/
4574
/
1.22 86/
1256 Fb 49/
716 32/
472 27/
391 20/
290 13/
1885
/
1.52 55/
799 Fb 25/
363 16/
237 13/
195 10/
143 6/
906
/
1.83 38/
550 Fb 14/
205 9/
132 7/
107 5/
77 3/
46Wood Part Head Drill Drill & Tap
Attachment Applications Number Description Style Point Capacity
Range 1565500 10-16 x 1'' Wafer #3 .030-.175 1/4''-1/2'' 2,500 1791000 10-16 x 1-13/16'' **PSD Flat #3 .030-.175 1/4''-3/4'' 2,500 1077000 10-24 x 3/4" Wafer #3 .036-.175 1/4''-3/8'' 8,000 1079000 10-24 x 1" Wafer #3 .036-.175 1/4''-1/2'' 5,000 1547500 10-24 x 1-1/4" PFH #3 .036-.175 1/4''-3/4'' 5,000 1643100 10-24 x 1-1/4" Wafer #3 .036-.175 1/4''-3/4'' 5,000 1548500 10-24 x 1-1/2" PFH #3 .036-.175 1/4''-1'' 3,000 1644100 10-24 x 1-1/2" Wafer #3 .036-.175 1/4''-1'' 3,000 1082000 10-24 x 1-7/16" *PFH #3 .060-.175 1/4''-3/4'' 3,000 1588910 #2 PSD Bit 1 1552500 12-24 x 1-5/8" *PFH #4 .125-.250 3/4''-1-1/8'' 2,500 1092000 12-24 x 2-1/4" *PFH #4 .125-.250 3/4''-1-3/8'' 2,000 1094000 12-24 x 2-3/4" *PFH #4 .125-.250 3/4''-1-5/8'' 1,500 1096000 1/4-20 x 3" *PFH #4 .125-.250 3/4''-2'' 1,000
A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500.
Adjust the screwgun nosepiece to properly seat the fastener.
Worn or damaged bit tip should be replaced.
The fastener is fully seated when the head is flush with the work surface.
Overdriving may result in torsional failure of the fastener or stripout of the substrate.
The fastener must penetrate beyond the metal structure a mini-mum of 3 pitches of thread.
All #10 diameter “Winged” parts must be driven into a minimum of 16 GA steel thickness.
All 1/4 and #12 diameter “Winged” parts must be driven into a minimum of 1/8" steel in order to break the wings consistently.
Dia. #10 #12 1/4 Pt. 3 4 4 20 728 -18 1266 -16 1540 -14 1522 -12 -2048 2650 1/8 -2030 2820
TEKS
W
OOD-T
O-M
ETALS
ELF-D
RILLINGF
ASTENERSSelector Guide
Performance Data
Fastener Steel Gauge (lapped) SHEAR VALUES (average lbs. ultimate)
Fastener (dia-tpi) 10-16 10-24 12-24 1/4-20 Tensile (lbs. min.) 1936 2702 3165 3860 Shear (avg. lbs. ult.) 1400 1500 2200 2700 Torque (min. in. lbs.) 61 65 150 168 FASTENER VALUES 12 .105'' 14 .075'' 16 .060'' 18 .048'' 20 .036'' 22 .030'' 24 .024'' 26 .018'' Gauge No. Decimal Equivalent
SHEET STEEL GAUGES
Teks®, Climaseal®and Spex™are trademarks of ITW Buildex and Illinois Tool Works, Inc.
Phillips Square Driv®is a registered trademark of the Phillips Screw Company.
© 2010 ITW Buildex and Illinois Tool Works, Inc. The values listed are ultimate averages achieved under laboratory conditions and
apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes.
Product Report No. 02705
14
Installation Guidelines
Dia. #10-16 #10-24 #12 1/4 Pt. 3 3 4 4 26 -24 208 -- -22 266 -20 299 334 -18 499 495 -16 708 702 -14 967 900 -12 1474 1570 1508 1803 3/16 -3865 4297 1/4 -4101-Fastener Steel Gauge
PULLOUT VALUES (average lbs. ultimate)
1349 West Bryn Mawr Avenue Itasca, Illinois 60143 630-595-3500 Fax: 630-595-3549 www.itwbuildex.com - -• Plywood, 2 x 4’s headers to steel framing • 2 x 4’s to steel framing Box Qty ®
* With wings ** With ribs under head
• Plywood, mansard, fascia, roofing, flooring to steel framing
CARTRIDGES 310 mL SIZE