FIBER OPTIC
CABLE
Product . . . 4
Support . . . 6
Incab Cable Range . . . 16
InSky OPGW . . . 18
InAir ADSS . . . 26
Incab Specialty Cable . . . 32
InFire Rated . . . 36 InDuct . . . 46 InArmor . . . 50 BlownIn . . . 68 InWater . . . 74 InAir Figure 8 . . . 78 InHome FTTH . . . 84 InDrop FTTH . . . 92 Semi-Finished Products . . . 96 Knowledge Base. . . . 102
Types and Parameters of Optical Fiber . . . 104
Color Identification Chart . . . 107
Transportation. Maintenance. Installation . . . 109
2
INCAB
13 YEARS
8,750,770
miles of fiber
354,800
miles of cable
1,231,800
miles of fiber
52,200
miles of cable
IN 2020
103
cable designs
WORKING SINCE 2007
GEOGRAPHY
of supply: Americas, Europe and Asia
One of the largest manufacturers of optical cables worldwide.
When presenting Incab we always speak about our "triple I": I³ = I × I × I: innovative, intellectual, individual.
"Triple I" by Incab
Alexander Smilgevich President
Mike Riddle
Executive Vice President [email protected]
Dan L Berg Vice President, Sales [email protected]
INNOVATIVE
INTELLECTUAL
INDIVIDUAL
We choose the most innovative technologies from among all available worldwide and build our products around them.
It is vital to us that our products always contain our maximum intellectual potential.
It is essential to us to address even the smallest details when serving our customers, no matter how large we grow.
We would be very happy to prove our "triple I" to you!
Watch the factory video
tour
PRODUCT
Incab America LLC has the widest product range
Design is one of the core competencies of Incab which developed from our
experience in the production and supply of fiber optic cables.
we design cables based on our
Customers' specific technical
requirements
types of cable designs
+
Specialty Cable
InSky OPGW
InFire Rated
InDuct
InArmor
InAir Figure 8
InWater
BlownIn
InAir ADSS
InHome FTTH
InDrop FTTH
Semi-Finished
SUPPORT
Support at all stages by consulting our customers on all
aspects of optical communication and operation. Full range
of services allows Incab to accumulate hands-on knowledge
and experience, which is used in the development of new
cable designs.
Knowledge Base
Some materials from the Knowledge Base are available in this catalog, pages 102 to 109. Accessories selection:
splice closures, fittings, clamps, connectors, vibration dampers, fixtures
Cable selection Transportation,
storage and installation guidelines
Our Advanced Cable Engineering System (ACES) is a unique
software tool to help engineers select the optimal OPGW and ADSS
design along with the associated accessories, including dead ends,
suspensions, down leads, splice closures and dampers.
ACES will also help engineers and planners prepare cost estimates,
generate a complete bill of materials, determine reel lengths, and
plan logistics.
ACES was developed by Incab in partnership with Preformed Line
Products, and we very much appreciate their assistance.
Latest updates on our website incabamerica.com
ACES: Advanced Cable
Engineering System
Cost estimation
Design calculation Specifications generation Optimal cable selection
Quality philosophy
“Quality means doing it right when no one is looking”. Henry FordPHILOSOPHY
Quality is in the heart of everything we do. Our quality policy is implemented through: — 100% step-by-step quality control; — best in the industry Test Center; — high-quality materials;
— quality management system is recognized as both effective and ISO compliant by TÜV International Certification; — declarations for all cable types manufactured by Incab; — reference letters and certificates provided by federal companies and controlling authorities;
— software to select the right type of fiber optic cable, the right size of the reels, and the optimal arrangement of reels on trucks and in containers;
— software for aerial cable calculations;
— calculation of power line electromagnetic fields; — continuous customer feedback.
STEP-BY-STEP QUALITY CONTROL
Quality Control employees carry out stringent control at all stages of the manufacturing process, including:
— incoming control of materials;
— measuring parameters of each optical fiber; — control of fiber length in the tubes;
— verification of compliance with the design requirements; — check of resistance and tightness of the jacket
(for armored cables);
— control of marking and packing.
Our line operators control the dimensions of the products throughout the manufacturing process. We use advanced high-precision control and measurement equipment: — МТР 9000 Optical Reflectometer;
— Yokogawa AQ7260 Optical Time Domain Reflectometer; — Ando AQ6319 Spectrum Analyzer;
— PK2500 Optical Spectrum Analyzer; — PK2400 Fiber Geometry System; — EXFO FTB-400 Universal Test System; — Zumbach Geometry Testers.
10
CERTIFICATES
All HFFR cables have the relevant fire safety certificates.
Our Quality Management System is certified as ISO compliant by TÜV International Certification (TIC).
Our environmental management system and health and safety management system are certified as ISO and BS OHSAS compliant by TÜV International Certification (TIC).
TEST CENTER
Our Test Center is equipped according to the latest industry standards to conduct type approval and periodic mechanical and environmental resistance tests per IEC 60794-1-2 (water penetration, temperature cycling, high humidity, vibration, stretching, bending, torsion, crush, compression).
FEEDBACK
In order to meet the world's highest quality standards, we continuously monitor feedback from our customers. For comments and suggestions, please, contact us — [email protected]
Best Materials
To produce Incab cables, we use the most advanced materials available in the market.
CORNING® SMF-28® ULTRA
Advantages:
— Increased equipment efficiency, 10% less fiber attenuation. — Significantly improved reliability and resistance to installation
damage. Ten times higher bend-resistance compared to standard single-mode fibers.
BOREALIS BIMODAL POLYETHYLENE
Advantages:
— Low shrinkage and high resistance to temperature changes. — Installation temperatures down to -22°F.
14
Best Equipment
CAPACITY:
— 4400 mi of cable per month — 650 mi of OPGW per month
PRODUCTION EQUIPMENT BY:
Maillefer, Medek&Schorner, Nexans, Photonium, Compotec and other manufacturers.
Fiber Optic Cable: — coloring lines; — loose tube lines; — stranding lines;
— sheathing lines with aramid servers; — steel wire armoring machines.
OPGW:
— production line for manufacture of stainless steel tubes containing optical fibers; — pre-cleaning and rewinding line; — cladding line;
— drawing line;
16
InAir ADSS
InAir ADSS MT Aramid DJ
InAir ADSS MT FiberGlass DJ
InAir ADSS MT Aramid
InAir ADSS MT FiberGlass
InAir ADSS MT FRP Defender
InSky OPGW InSky OPGW C InSky OPGW S InSky MASS InSky OPGW CA InPhase OPPC InSky OPGW AP
InSky ACS Ground Wire
InArmor CT CST Light
InArmor+ CT FRP Dielectric
InArmor+ CT GSW
InArmor+ SST
InArmor+ MT FiberGlass DJ Dielectric Specialty Cable InDuct MT InDuct MT FiberGlass InDuct MT Aramid InDuct InArmor InArmor MT CST Light InArmor MT CST InArmor MT CST DJ InFire Rated
InFire Rated Dielectric InFire Rated Universal
InFire Rated Dielectric Light
InFire Rated Outdoor
BlownIn MT 12 BlownIn MT 24 BlownIn BlownIn CT InWater Submersible CT GSW2 InWater InAir Figure 8 MT GSW InAir Figure 8 InHome FTTH InHome Distribution TB InHome Simplex TB InHome Duplex TB
InDrop Flat Type Reinforced
InDrop Round Type Tight-Buffered
InDrop FTTH InArmor++ CT FRP2 Dielectric InArmor++ CT GSW2 InArmor+ MT GSW Wetland InArmor++ MT GSW2 Wetland InWater Submersible SST GSW2 InAir Figure 8 MT FRP InAir Figure 8 CT GSW InAir Figure 8 CT FRP InHome Riser TB InHome Riser MT InHome Distribution MT
InDrop Round Type InArmor+ SST GSW
InArmor+ MT GSW
InArmor++ MT GSW2
InArmor++ MT FRP2 Dielectric
Protection of power lines from lightning overvoltage
APPLICATION
Construction of optical communication systemsOPERATING PARAMETERS
Operating temperature -58°F...+185°F Installation temperature -22°F...+122°FTransportation and storage temperature -58°F...+158°F
Minimun bending radius 20×cable diameter
Warranty as specifed in the supply
agreement, min 2 years We design cables based on our Customers' specific technical requirements. Please, contact us for a cable designed to your exact specifications.
In
Sk
y OP
G
W
Optical ground wire (OPGW) shields high-voltage conductors from lightning strikes
Aluminum alloy wires provide conductivity for fault current
Up to 96 fibers in a tube
InSky OPGW C
Optical Ground Wire Central loose tube (C)
1 2 3 3
DESIGN
1. Optical fiber2. Stainless steel tube filled with water-blocking gel
3. Stranded wires (aluminum-clad steel wires and/or aluminum alloy wires)
ADVANTAGES
ACS wires are highly corrosion-resistant
FEATURES
Crush — 571 lb/in Range Fiber count up to 96 Cable weight, lb/ft 0.134...0.827 Cable diameter, in 0.315...0.709 Rated breaking strength (RBS), lb 5620...47210 Maximum rated design tension (MRDT), lb 3372...28101 Elasticity modulus (final), ksi 10153...23206 Short circuit capacity (initial temp 77°F), kA²•s 5...300 Short circuit current for 0.5 s, kA 2...20Сlick here to see detailed
features of this design
20 In Sk y OP G W
Optical ground wire (OPGW) shields high-voltage conductors from lightning strikes
Aluminum alloy wires provide conductivity for fault current
InSky OPGW CA
Optical Ground Wire Central Aluminum-clad loose tube (CA)
DESIGN
1. Optic fiber
2. Aluminum-clad stainless steel tube filled with water-blocking gel 3. Stranded wires (aluminum-clad steel wires and/or aluminum alloy wires)
ADVANTAGES
FEATURES
Crush — 857 lb/inRange
Fiber count up to 96
Rated breaking strength (RBS), lb 5620 … 47210 Maximum rated design tension (MRDT), lb 3372 … 28101 Cable diameter, in 0.354 … 0.709 Cable weight, lb/ft 0.134 … 0.827 Elasticity modulus (final), ksi 10153 … 23206 Short circuit capacity (initial temp 77°F), kA²•s 5...300 Short circuit current for 0.5 s, kA 3...20
Up to 96 fibers
Enhanced corrosion resistance: ACS wires and aluminum-clad stainless steel tube 1
2 3
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In Sk y OP G W
InSky OPGW AP
Optical Ground Wire Aluminum Pipe (AP)
DESIGN
1. Central strength member (FRP) 2. Optical fibers
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable tape
5. Thermal barrier 6. Aluminum pipe
7. Aluminum-clad steel wire and/or aluminum alloy wires
ADVANTAGES
FEATURES
Crush — 571 lb/in Range Fiber count up to 144 Cable weight, lb/ft 0.300...0.900 Cable diameter, in 0.527...1.000 Rated breaking strength (RBS), lb 5620...47210 Maximum rated design tension (MRDT), lb 3372...28101 Elasticity modulus (final), ksi 6962...16679 Short circuit capacity (initial temp 104°F), kA²•s 5...400 Short circuit current for 0.5 s, kA 3...30Up to 144 fibers
Highly corrosion-resistant: ACS wires and aluminum pipe Convenient splice preparation 1 2 3 6 7 5 4
Optical ground wire (OPGW) shields high-voltage conductors from lightning strikes
Aluminum alloy wires provide conductivity for fault current
Сlick here to see detailed
features of this design
22 In Sk y OP G W 22
InSky OPGW S
Optical Ground Wire Stranded (S)
DESIGN
1. Central strength member
(aluminum-clad steel or aluminum alloy wire) 2. Optical fiber
3. Stainless steel tube filled with water-blocking gel
4. Stranded wires (aluminum-clad steel wires and/or aluminum alloy wires)
ADVANTAGES
FEATURES
Crush — 571 lb/in Range Fiber count up to 432 Cable weight, lb/ft 0.222...1.028 Cable diameter, in 0.433…0.984 Rated breaking strength (RBS), lb 10566...61822 Maximum rated design tension (MRDT), lb 6295...37093 Elasticity modulus (final), ksi 10153...23206 Fault current capacity (initial temperature 77°F),kA²•s
5...550 Short circuit current for 0.5 s, kA 4…30
Up to 432 fibers
ACS wires are highly corrosion-resistant 1 2 3 4 4
Optical ground wire (OPGW) shields high-voltage conductors from lightning strikes
Aluminum alloy wires provide conductivity for fault current
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In Sk y OP G W
InSky MASS
Metallic Aerial Self-Supporting (MASS)
FEATURES
Crush — 571 lb/inMaximum rated design tension —6744 lb
Fiber count up to 12 up to 24 up to 36 up to 48 Cable diameter, in 0.3228 0.3228 0.3425 0.3425 Cable weight, lb/ft 0.1939 0.1939 0.2139 0.2139
Crush — 571 lb/in
Maximum rated design tension —16 861 lb
Fiber count up to 12 up to 24 up to 36 up to 48 Cable diameter, in 0.5000 0.5000 0.5000 0.5000 Cable weight, lb/ft 0.4782 0.4782 0.4782 0.4782
Crush — 571 lb/in
Maximum rated design tension —11 240 lb
Fiber count up to 12 up to 24 up to 36 up to 48 Cable diameter, in 0.4094 0.4094 0.4252 0.4291 Cable weight, lb/ft 0.3266 0.3261 0.3496 0.3502
Crush — 571 lb/in
Maximum rated design tension —22 481 lb
Fiber count up to 12 up to 24 up to 36 up to 48 Cable diameter, in 0.5512 0.5709 0.5709 0.5709 Cable weight, lb/ft 0.6050 0.6376 0.6376 0.6376 1 2 3
DESIGN
1. Optical fiber.2. Stainless steel tube filled with water-blocking gel.
3. Stranded wires (galvanized steel wires or aluminum clad steel wires).
ADVANTAGES
Maximum rated design tension 22481 lb
High strength, small size
ASC wire makes the cable exceedingly rustproof
Large spans between towers, installation over rivers and ravines
Сlick here to see detailed
features of this design
24 In Sk y OP G W
InSky ACS Ground Wire
Aluminum-Clad Steel (ACS) Ground Wire
DESIGN
1. Central strength member (aluminum-clad steel wire) 2. Stranded wires (aluminum-clad steel wires)
ADVANTAGES
Aluminum-clad steel wires are corrosion-resistant 1 2 2 A standard component of high-voltage transmission lines
FEATURES
Range Outer diameter, in 0.299 ... 0.890 Cable weight, lb/ft 0.134...2.016 Rated breaking strength (RBS), lb 6744...157366 Cross section, in² 0.054...0.930ACS ground wires shield high-voltage conductors from lightning strikes
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In Sk y OP G W
InPhase OPPC
Optical Phase Conductor (OPPC)
DESIGN
1. Optical fiber 2. Stainless steel tube 3. Aluminum-clad steel wire
4. Aluminum alloy wire or aluminum wire
ADVANTAGES
FEATURES
Crush — 571 lb/in Range Fiber count up to 288 Cable diameter, in 0.394 ... 1.339 Cable weight, lb/ft 0.134 ... 1.334 Rated breaking strength (RBS), lb 3372...44961 Cross section, in² 0.078 ... 0.930Up to 288 fibers in a tube
ACS wires are highly corrosion-resistant
Effective solution to provide redundancy in harsh conditions, such as long cable spans, crossings of cable spans, power lines with previously installed OPGW and ADSS and others 1 2 3 3 4 4
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
Can also be used in ducts
or as direct buried cable Dry design — easy to strip Designed for aerial installation
on transmission towers, high voltage power lines and railway catenary; highly resistant to electromagnetic effect
InAir ADSS
OPERATING PARAMETERS
Operating temperature* -58°F...+158°F
Installation temperature -22°F...+122°F
Transportation and storage temperature -58°F...+158°F
Minimum bending radius 15×cable diameter
Life time 25 years
Warranty as specified in the supply
agreement, min 2 years *Operating temperature range can be increased on request.
OPTIONS
All cables of this group may be produced in versions:
Flame-retardant cable/Level 2 (page 38) and with jacket which is made of a tracking-resistant material (can be used in case of cable exposure to the electric field with a potential above 12 kV).
We design cables based on our Customers' specific technical requirements.
APPLICATION
In A ir A D S S
ADVANTAGES
Anti-rodent additive in the outer jacket for first-line protectionSuperior protection from mechanical damage — FRP rods provide strength and second-line protection
FEATURES
InAir ADSS MT FRP Defender
Multi-Tube (MT) FiberGlass Rods (FRP) Defender
Crush — 228 lb/in
Maximum rated design tension — 1574-4496 lb
Range
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144 Cable diameter, in 0.488...0.614 0.496...0.622 0.512...0.638 0.520...0.646 0.567...0.669 0.567...0.669 0.693 Cable weight, lb/ft 0.092...0.165 0.094...0.168 0.100...0.178 0.102...0.181 0.121...0.190 0.121...0.190 0.197 Minimum bending radius, in 7.323...9.213 7.441...9.331 7.677...9.567 7.795...9.685 8.504...10.039 8.504...10.039 10.394
1 2 3 4 4 5 8 6 7
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable yarns 5. Inner jacket 6. Fiberglass rods 7. Jacket 8. Ripcord Completely protected from water ingress
Designed for use in aerial applications of 138 kV or less where damage from squirrels/rodents is apparent
Сlick here to see detailed
features of this design
In A ir A D S S 1 2 3 4 5 6 7 8
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable yarns 5. Inner jacket 6. Aramid yarns 7. Jacket 8. Ripcord
ADVANTAGES
For construction of communication lines between towns and cities with distances between towers reaching 1640 ftAerial installation on distribution and transmission lines up to 138 kV and above with tracking-resistant jacket
The most reliable among InAir cables. Double tensile strength
Wide range of operating temperatures. Installation temperature down to -22°F All-dielectric design – fully
resistant to electromagnetic fields
Maximum rated design tension up to 8992 lb
InAir ADSS MT Aramid DJ
Multi-Tube (MT) Aramid yarns Double Jacket (DJ)
FEATURES
Crush – 171 lb/inMaximum rated design tension — 899....8992 lb Range Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.480...0.598 0.504...0.614 0.528...0.630 0.551...0.661 Cable weight, lb/ft 0.077...0.120 0.085...0.126 0.092...0.132 0.099...0.145 Minimum bending radius, in 7.205...8.976 7.559...9.213 7.913...9.449 8.268...9.921
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In A ir A D S S 1 2 3 4 5 6 8 7
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable yarns 5. Inner jacket 6. Fiberglass yarns 7. Jacket 8. Ripcord
ADVANTAGES
All-dielectric design – fully resistant to electromagnetic fields
Aerial installation on distribution and transmission lines up to 138 kV and above with tracking-resistant jacket
Wide range of operating temperatures. Installation temperature down to -22°F Cost-effective solution
for city trunk lines
InAir ADSS MT FiberGlass DJ
Multi-Tube (MT) FiberGlass yarns Double Jacket (DJ)
Maximum rated design tension up to 3372 lb with span lengths up to 984 ft
FEATURES
Crush – 171 lb/inMaximum rated design tension — 899...3372 lb Range Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.492...0.547 0.516...0.563 0.539...0.579 0.563...0.606 Cable weight, lb/ft 0.082...0.106 0.090...0.110 0.097...0.116 0.105...0.126 Minimum bending radius, in 7.382...8.209 7.736...8.445 8.091...8.681 8.445...9.094
Сlick here to see detailed
features of this design
In A ir A D S S 30
ADVANTAGES
All-dielectric design – fully resistant to electromagnetic fields
Aerial installation on distribution and transmission lines up to 34.5 kV
Wide range of operating temperatures. Installation temperature down to -22°F Cost-effective design
Maximum rated design tension up to 2248 lb with span lengths up to 656 ft
FEATURES
Crush – 171 lb/inMaximum rated design tension — 674...2248 lb Range Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.307...0.441 0.331...0.461 0.362...0.484 0.394...0.508 Cable weight, lb/ft 0.031...0.065 0.035...0.070 0.041...0.076 0.047...0.082 Minimum bending radius, in 4.606...6.614 4.961...6.909 5.433...7.264 5.906...7.618 1 2 3 4 4 5 7 6
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable yarns
5. Aramid yarns 6. Jacket 7. Ripcord
Dry design – easy to strip
Reduced weight and size. Low ice and wind load
InAir ADSS MT Aramid
Multi-Tube (MT) Aramid yarns
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In A ir A D S S 1 2 3 4 4 5 7 6
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable yarns
5. Fiberglass yarns 6. Jacket 8. Ripcord
ADVANTAGES
InAir ADSS MT FiberGlass
Multi-Tube (MT) FiberGlass yarns
All-dielectric design – fully resistant to electromagnetic fields
Dry design – easy to strip
Cost-effective solution for city trunk lines Reduced weight and size. Low ice and wind load Maximum rated design tension up to 2248 lb with span lengths up to 656 ft
Wide range of operating temperatures. Installation temperature down to -22°F Aerial installation on distribution and transmission lines up to 34.5 kV
FEATURES
Crush – 171 lb/inMaximum rated design tension — 674...2248 lb Range Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.366...0.465 0.39...0.48 0.413...0.496 0.445...0.52 Cable weight, lb/ft 0.047...0.075 0.051...0.078 0.056...0.082 0.063...0.089 Minimum bending radius, in 5.492...6.968 5.846...7.205 6.201...7.441 6.673...7.795
Сlick here to see detailed
features of this design
34
Specialty Cables
for harsh environment
MEASURE
REDUCE
Temperature Deformation Movement Acoustics
Deviation angle Leakage
Pressure Emergency reaction time Incidents of theft Forced downtime of technical facilities Emergency damages Monitoring costs Environmental damage caused by leaks
The world around us is changing faster than ever before. Every day new challenges come up and instead of fighting the change, we should embrace it. Just like optical fiber does. From just being the key element of telecommunication networks, it has been adapted to the data acquisition and monitoring purposes for various applications. Always keeping abreast of the latest developments Incab launched a range of specialty cables backed by extensive manufacturing
experience since 2007. Now we are excited to introduce our new project dedicated to this type of cables.
Discover the full range of specialty cables for various applications, which are developed in cooperation with top-notch industry experts.
Welcome to Wires&Bytes - wiresnbytes.com
S pec ia lt y C ab le
Application areas
Oil & Gas
Retrievable designs, Permanent installation,
Downhole сhemical injection,
Pipeline monitoring
Cable components
Structural health
monitoring
Cryogenic monitoring
S pec ia lt y C ab le36 In Fir e R at e d
InFire Rated
entertainment centers large data centers defense sector security monitoringindustrial and mining companies sport-facilities infrastructure and educational institutions subway atomic energetics
TYPICAL APPLICATIONS
for fire protection and other systems which are needed to work under fire conditions
for child care centers, educational institutions, board and care facilities, hospitals, dormitory blocks
for high-occupancy buildings
for buildings and closed facilities
for individual installation in cable structures and working spaces
for open cable structures
APPLICATION
Recommended for installation on sites with increased security requirements tower buildings refineries and petrochemical industry
In Fir e R at e d
single cabling
group cabling
low smoke
and gas emission
halogen-free
low toxicity
fire
rated
FIRE SAFETY LEVELS
Ev ery ne xt st ep includes pr evious st eps
2
3
Fi
re
R
ate
d
1
Fl
ame
-r
et
ar
dan
t c
ab
le
TYPICAL APPLICATIONS
for child care centers, educational institutions, board and care facilities, hospitals, dormitory blocks
38 In Fir e R at e d InArmor+ MT GSW Wetland
LEVEL 2
Group laying, low smoke and gas emission, halogen-free
LEVEL 3
InDuct InArmorFlame-retardant cable
InHome Riser TB InHome Riser MT InHome FTTH InHome Distribution TB InHome Distribution MT InHome Simplex TB InHome Duplex TB InDrop FTTHInDrop Flat Type Reinforced
InDrop Round Type Tight-buffered
InDrop Round Type
Low toxicity InArmor MT CST InArmor MT CST DJ InArmor CT CST Light InArmor+ SST InArmor+ MT GSW InArmor+ MT FRP Dielectric InArmor++ MT GSW2 InArmor++ MT FRP2 Dielectric InArmor+ CT GSW InArmor+ CT FRP Dielectric InArmor+ SST GSW InDuct MT FiberGlass
In Fir e R at e d
LEVEL 1
Single laying InAir ADSS InArmor MT CST DJ InArmor CT CST Light InArmor+ MT GSW InArmor+ CT GSWInAir ADSS MT Aramid
InAir ADSS MT FiberGlass InAir ADSS MT FRP Defender
InAir ADSS MT Aramid DJ
InAir ADSS MT FiberGlass DJ
InHome Riser TB InHome Riser MT InHome FTTH InHome Distribution TB InHome Distribution MT InHome Simplex TB InHome Duplex TB InDrop FTTH
InDrop Flat Type Reinforced
InDrop Round Type Tight-buffered
InDrop Round Type
InArmor MT CST InArmor
40 In Fir e R at e d
ADVANTAGES
InFire Rated
flame-retardantin group laying low smoke halogen-free
low toxicity of combustion products remain operative
exposed to fire for at least 180 minutes
InFire Rated Universal InFire Rated Universal Dielectric
InFire Rated Dielectric Light
InFire Rated Dielectric
InFire Rated Outdoor
We design cables based on our Customers' specific technical requirements.
In Fir e R at e d
ADVANTAGES
DESIGN
1. Optical fiber 2. Stainless steel tube 3. Armor of steel wires 4. Halogen-free jacketInFire Rated Universal
High resistance to crushing (more than 571 lb/in) which is retained even after the fire
Up to 96 fibers in a tube
Suitable for all applications Small size – thin,
light, economical Remains functional under direct flame for at least 180 minutes
Minimum combustible content
Diameter less than 0.39 in
Withstands the physical impact and water used during fire-fighting
FEATURES
Maximum rated design tension — 899 lb
Crush — from 571 lb/in
Fiber count up to 24 up to 36 up to 48 up to 72 up to 96 Cable diameter, in 0.346 0.362 0.374 0.39 0.409 Cable weight, lb/ft 0.103 0.112 0.12 0.13 0.142 Minimum bending
radius, in 5.197 5.433 5.61 5.846 6.142
Maximum rated design tension — 1574 lb
Crush — from 571 lb/in
Fiber count up to 24 up to 36 up to 48 up to 72 up to 96 Cable diameter, in 0.378 0.378 0.39 0.406 0.425 Cable weight, lb/ft 0.132 0.131 0.14 0.149 0.16 Minimum bending radius, in 5.669 5.669 5.846 6.083 6.378 4 3 2 1
Сlick here to see detailed
features of this design
42 In Fir e R at e d
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. Gel-filled loose tube
4. Inner jacket made of halogen-free retardant polymer compound
5. Water-sweallable yarns 6. Fiberglass rods 7. Fiberglass yarns 8. Halogen-free jacket 1 6 7 8 4 3 2 5
InFire Rated Universal Dielectric
All-dielectric design Remains functional
under direct flame for at least 180 minutes
ADVANTAGES
Suitable for all applications
FEATURES
Maximum rated design tension — 1574 lb
Crush — from 228 lb/in
Fiber count up to 24 (6*4) up to 48 (6*8) up to 72 (6*12) up to 96 (6*16) up to 144 (6*24) Cable diameter, in 0.583 0.594 0.626 0.665 0.697 Cable weight, lb/ft 0.184 0.190 0.208 0.231 0.247
Сlick here to see detailed
features of this design
In Fir e R at e d 1 2 3 4 5 3 6
DESIGN
1. Optical fiber 2. Tight-buffer 3. Fiberglass yarns4. Inner jacket made of halogen-free flame-retardant polymer compound 5. Mica glass tape
6. Halogen-free jacket
InFire Rated Dielectric
FEATURES
Maximum rated design tension — 247 lb
Crush — from 114 lb/in
Fiber count up to 2 up to 4 up to 6 up to 8 up to 12 up to 16 up to 24 Cable diameter, in 0.421 0.445 0.457 0.469 0.500 0.524 0.555 Cable weight, lb/ft 0.097 0.107 0.113 0.117 0.130 0.142 0.157 Minimum bending radius, in 4.224 4.449 4.567 4.685 5.000 5.236 5.551
Easy to dress and install
All-dielectric design Remains functional
under direct flame for at least 180 minutes
Up to 24 fibers
ADVANTAGES
Сlick here to see detailed
features of this design
44 In Fir e R at e d
DESIGN
1. Optical fiber 2. Water-blocking gel 3. Loose tube 4. Fiberglass yarns5. Inner jacket made of halogen-free flame-retardant polymer compound 6. Mica glass tape
7. Halogen-free jacket
All-dielectric design Remains functional
under direct flame for at least 180 minutes
Up to 24 fibers
ADVANTAGES
InFire Rated Dielectric Light
1 2 3 4 4 7 6 5
FEATURES
Maximum rated design tension — 225 lb
Crush — 114 lb/in
Fiber count up to 8 up to 16 up to 24 Cable diameter, in 0.327 0.35 0.366 Cable weight, lb/ft 0.057 0.066 0.071 Minimum bending radius, in 3.268 3.504 3.661
Maximum rated design tension — 450 lb
Crush — 114 lb/in
Fiber count up to 8 up to 16 up to 24 Cable diameter, in 0.366 0.39 0.402 Cable weight, lb/ft 0.072 0.081 0.086 Minimum bending radius, in 3.661 3.898 4.016
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In Fir e R at e d
ADVANTAGES
InFire Rated Outdoor
7 6 5
4 3
2 1
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-swellable yarns
5. Inner jacket made of halogen-free flame-retardant polymer compound 6. Corrugated steel tape armor
7. Halogen-free jacket
Armor ensures excellent rodent resistance
Easy to install and splice prep Up to 144 fibers
Remains functional under direct flame for at least 180 minutes
FEATURES
Maximum rated design tension — 607 lb
Crush — 171 lb/in
Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.488 0.512 0.539 0.575 Cable weight, lb/ft 0.131 0.143 0.161 0.171 Minimum bending radius, in 7.323 7.677 8.091 8.622
Сlick here to see detailed
features of this design
InDuct
Designed for duct installations
APPLICATION
Applied in tubes, ducts, trays, blocks, tunnels, collecting channels, with no risk of rodent attacks
OPERATING PARAMETERS
Operating temperature* -58°F (-49°F InDuct
MT)...+158°F
Installation temperature -22°F...+122°F
Transportation and storage temperature -58°F...+158°F
Minimum bending radius 15×cable diameter
Life time 25 years
Warranty as specified in the supply
agreement, min 2 years *Operating temperature range can be increased on request
Suitable for aerial installation: power lines, lamp posts, railway overhead systems
OPTIONS
All InDuct cables may be produced in these variations:
Flame-retardant cable/Level 1 and Flame-retardant cable/Level 2 (page 28). We design cables based on our Customers' specific technical requirements.
In D u c t
FEATURES
Option PE 250Outer jacket — PE (polyethylene) Fiber count — up to 288 Cable diameter, in 0.220...0.441 Cable weight, lb/ft 0.014...0.045 Operation tension, lb 67...225 Installation tension, lb 225...674 Option PA 200
Outer jacket — PA (polyamide) Fiber count — up to 288 Cable diameter, in 0.177...0.366 Cable weight, lb/ft 0.009...0.032 Operation tension, lb 56...180 Installation tension, lb 169...495
InDuct MT
Multi-Tube (MT)
1 2 3 4 5DESIGN
1. Central strength member (FPR) 2. Optical fiber
3. PBT loose tube filled with water-blocking gel 4. Water-swellable yarns
5. Jacket
ADVANTAGES
All-dielectric designMaximum rated design tension 607 lb
Up to 288 fibers
Сlick here to see detailed
features of this design
48 In D u c t
InDuct MT FiberGlass
Multi-Tube (MT) FiberGlass yarns
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tube filled with water-blocking gel 4. Water-swellable yarns 5. Fiberglass yarns 6. Polymer jacket 7. Ripcord
ADVANTAGES
All-dielectric design Up to 864 fibers 1 2 3 5 6 7 4 4FEATURES
Maximum rated design tension — 337 lb
Crush — 171 lb/in
Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.378 0.39 0.425 0.457 Cable weight, lb/ft 0.046 0.048 0.056 0.064 Minimum bending radius, in 5.669 5.846 6.378 6.85 Maximum rated design tension — 450 lb
Crush — 171 lb/in
Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.386 0.394 0.425 0.457 Cable weight, lb/ft 0.048 0.049 0.056 0.064 Minimum bending radius, in 5.787 5.906 6.378 6.85
Maximum rated design tension — 607 lb
Crush — 171 lb/in Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.39 0.402 0.429 0.457 Cable weight, lb/ft 0.05 0.052 0.057 0.065 Minimum bending radius, in 5.846 6.024 6.437 6.85
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
D
u
c
t
Maximum rated design tension — 607 lb
Crush — 171 lb/in Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.39 0.402 0.429 0.457 Cable weight, lb/ft 0.05 0.052 0.057 0.065 Minimum bending radius, in 5.846 6.024 6.437 6.85
InDuct MT Aramid
Multi-Tube (MT) Aramid yarns
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tube filled with water-blocking gel 4. Water-swellable yarns 5. Aramid yarns 6. Jacket 7. Ripcord
ADVANTAGES
1 2 3 5 7 6 4 All-dielectric design Maximum rated designtension up to 607 lb
Easy to install
FEATURES
Maximum rated design tension — 337 lb
Crush — 171 lb/in Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.378 0.406 0.441 0.472 Cable weight, lb/ft 0.047 0.053 0.062 0.07 Minimum bending radius, in 5.669 6.083 6.614 6.791
Maximum rated design tension — 607 lb
Crush — 171 lb/in Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.386 0.409 0.441 0.472 Cable weight, lb/ft 0.05 0.055 0.062 0.07 Minimum bending radius, in 5.787 6.142 6.614 6.791
Сlick here to see detailed
features of this design
Suitable for aerial installation between buildings and structures (however, its higher weight and larger diameter compared to self-supporting cables must be taken into consideration) Designed for harsh environments
with potential mechanical impact: in all ground types, swamps and harsh rivers
Applied in ducts, trays, blocks, tunnels, and collecting channels
APPLICATION
OPERATING PARAMETERS
Operating temperature* -58°F...+158°F
Installation temperature -22°F...+122°F
Transportation and storage temperature -58°F...+158°F
Minimum bending radius 15×cable diameter
Life time 25 years
Warranty as specified in the supply
agreement, min 2 years *Operating temperature range can be increased on request
OPTIONS
All InArmor cables may be produced in these variations:
Flame-retardant cable/Level 1 and Flame-retardant cable/Level 2 (page 31).
InArmor+ SST cable may be produced
with fire rated jacket (page 40).
We design cables based on our Customers' specific technical requirements.
In
Ar
mo
r
InArmor MT CST
Multi-Tube (MT) Corrugated Steel Tape (CST)
Maximum rated design tension up to 607 lb Resistance to crushing load from 171 lb/in
FEATURES
Maximum rated design tension — 607 lb Crush — 171 lb/in
Fiber count up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.417 0.441 0.469 0.504 Cable weight, lb/ft 0.082 0.088 0.099 0.113 Minimum bending radius, in 6.260 6.614 7.028 7.559
ADVANTAGES
Increased tightness due to application of water-swellable tape Cost-effective design The most popular design Excellent rodent resistance Reduced weight and size. Suitable for blowing in tubes 1 2 3 4 7 6 5DESIGN
1. Central strength member (FRP) 2. Water-swellable yarns 3. Optical fiber
4. PBT loose tubes filled with water-blocking gel 5. Water-swellable tape
6. Corrugated steel tape armor 7. Jacket
* InArmor MT CST cable may be produced with even higher maximum rated design tension up to 1,124 lb. Please contact us for details.
Сlick here to see detailed
features of this design
52 In Ar mo r
FEATURES
Maximum rated design tension — 607 lb Crush — 171 lb/in
Fiber count Up to 48 (6х8) Up to 72 (6х12) Up to 96 (6х16) Up to 144 (6х24)
Cable diameter, in 0.488 0.512 0.539 0.575
Cable weight, lb/ft 0.106 0.117 0.126 0.141
Minimum bending radius, in 7.323 7.677 8.091 8.622
* InArmor MT CST cable may be produced with even higher maximum rated design tension up to 1,124 lb. Please contact us for details.
InArmor MT CST DJ
Multi-Tube (MT) Corrugated Steel Tape (CST) Double Jacket (DJ)
Improved reliability due to inner jacket
Excellent rodent resistance Proven reliable design Maximum rated design tension up to 607 lb Resistance to crushing load from 171 lb/in
ADVANTAGES
1 2 3 4 7 6 5 5 8DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Water-swellable yarns
6. Inner jacket
7. Corrugated steel tape armor 8. Jacket
Cost-effective design
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
Ar
mo
r
InArmor CT CST Light
Central Tube (CT) Corrugated Steel Tape (CST) Light
FEATURES
Maximum rated design tension — 607 lb Crush — 286 lb/in
Fiber count up to 12 up to 16 up to 24 Cable diameter, in 0.287 0.295 0.307 Cable weight, lb/ft 0.048 0.049 0.051 Minimum bending radius, in 4.311 4.429 4.606
ADVANTAGES
Cost-effective design Excellent rodent resistance
Reduced weight and size 3 4 5 6
DESIGN
1. Optical fiber2. PBT loose tube filled with water-blocking gel 3. Water-blocking gel or water-swellable yarns 4. Corrugated steel tape armor
5. Jacket 6. Steel wires 1 2 Up to 24 fibers Maximum rated design tension up to 607 lb Resistance to crushing load from 286 lb/in
Сlick here to see detailed
features of this design
54 In Ar mo r
InArmor MT CST Light
Multi-Tube (MT) Corrugated Steel Tape (CST) Light
3 4 5 6
DESIGN
1. Optical fiber2. PBT loose tube filled with water-blocking gel 3. Water-blocking gel or water-swellable yarns 4. Corrugated steel tape armor
5. Jacket 6. Steel wires
1 2
ADVANTAGES
Cost-effective design Excellent rodent resistance
Reduced weight and size Up to 48 fibers
Maximum rated design tension up to 607 lb Resistance to
crushing load from 171 lb/in
FEATURES
Maximum rated design tension — 607 lb Crush — 171 lb/in
Fiber count up to 48
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In Ar mo r
ADVANTAGES
The smallest diameter Excellent rodent resistance 3DESIGN
1. Optical fiber2. Stainless steel tube filled with water-blocking gel 3. Jacket 1 2 Maximum rated design tension up to 337 lb Maximum resistance to crushing load from 400 lb/in 100% waterproof
InArmor
+
SST
Stainless Steel Tube (SST)
FEATURES
Maximum rated design tension — 337 lb Crush — 400 lb/in
Fiber count up to 96
Сlick here to see detailed
features of this design
56
In
Ar
mo
r
InArmor
+
MT FiberGlass DJ Dielectric
Multi-Tube (MT) FiberGlass yarns Double Jacket (DJ) Dielectric
ADVANTAGES
All-dielectric design Fiberglass yarns prevent
damage by rodents 3 4 5 6 7
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Inner jacket
6.Fiberglass yarns 7. Jacket
1 2
Maximum rated design tension up to 607 lb Resistance
to crushing load from 171 lb/in
FEATURES
Maximum rated design tension — 607 lb Crush — 171 lb/in Fiber count Up to 16 (4*4) Up to 32 (4*8) Up to 48 (4*12) Up to 64 (8*8) Up to 72 (6*12) Up to 96 (6*16) Up to 96 (8*12) Cable diameter, in 0.425 0.433 0.445 0.48 0.465 0.496 0.516 Cable weight, lb/ft 0.079 0.081 0.085 0.102 0.093 0.104 0.112 Minimum bending radius, in 6.378 6.496 6.673 7.205 6.968 7.441 7.736
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
Ar
mo
r
InArmor
+
CT GSW
Central Tube (CT) Galvanized Steel Wires (GSW)
3 4
5
DESIGN
1. Optical fiber
2. PBT loose tube filled with water-blocking gel 3. Water-blocking gel or water-swellable yarns 4. Armor of galvanized steel wires
5. Jacket 1 2 100% waterproof
FEATURES
ADVANTAGES
Cost-effective design Excellent rodent resistance
Reduced weight
and size Up to 24 fibers
Maximum rated design tension up to 1124 lb lb Resistance to crushing load from 286 lb/in
Maximum rated design tension — 1124 lb Crush — 400 lb/in Fiber count up to 16 up to 24 Cable diameter, in 0.319 0.327 Cable weight, lb/ft 0.078 0.083 Minimum bending radius, in 4.783 4.902 Reliable protection from serious mechanical impact
Сlick here to see detailed
features of this design
58 In Ar mo r
DESIGN
1. Optcal fiber2. PBT loose tube flled with water-blocking gel 3. Water-blocking gel or water-swellable yarns 4. Armor of fiberglass rods
5. Jacket
ADVANTAGES
1 2 3 4 5 All-dielectric design Reliable protection from serious mechanical impactExcellent rodent resistance Reduced weight, suitable
for aerial installation
Up to 24 fibers
Maximum resistance to crushing load from 400 lb/in
Maximum rated design tension up to 1798 lb
InArmor
+
CT FRP Dielectric
Central Tube (CT) FiberGlass Rods (FRP) Dielectric
FEATURES
Maximum rated design tension — 1798 lb Crush — 400 lb/in
Range
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24 Cable diameter, in 0.421 0.421 0.421 0.421 0.429 Cable weight, lb/ft 0.075 0.075 0.074 0.074 0.076 Minimum bending radius, in 6.319 6.319 6.319 6.319 6.437
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
Ar
mo
r
InArmor
+
MT GSW
Multi-Tube (MT) Galvanized Steel Wires (GSW) Wetland
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Inner jacket
6. Armor of galvanized steel wires 7. Jacket
ADVANTAGES
The most popular design Reliable protection from serious mechanical impact Excellent rodentresistance Maximum rated design tension up to 17985 lb
Resistance to crushing load up to 571 lb/in 1 2 3 4 4 7 6 5
Maximum rated design tension — 1574-4496 lb Crush — 228 lb/in
Range
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 Cable diameter, in 0.441...0.504 0.472...0.512 0.488...0.512 0.496...0.52 0.535...0.559 0.535...0.559 Cable weight, lb/ft 0.138...0.168 0.154...0.174 0.162...0.173 0.168...0.175 0.191...0.199 0.191...0.199 Minimum bending radius, in 6.614...7.559 7.087...7.677 7.323...7.677 7.441...7.795 8.031...8.386 8.031...8.386 Maximum rated design tension — 8992-17985 lb
Crush — 571 lb/in
Fiber count up to 24 up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.693...0.791 0.709...0.823 0.732...0.823 0.748...0.827 0.787...0.858 Cable weight, lb/ft 0.351...0.556 0.367...0.595 0.388...0.595 0.405...0.597 0.438...0.631 Minimum bending radius, in 10.394...11.870 10.630...12.342 10.984...12.342 11.220...12.402 11.811...12.874
FEATURES
Сlick here to see detailed
features of this design
60 In Ar mo r
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Inner jacket
6. Fiberglass rods 7. Jacket
ADVANTAGES
Reduced weight, suitable for aerial installation
Reliable protection from serious mechanical impact
Excellent rodent
resistance All-dielectric design
Maximum rated design tension up to 4496 lb Resistance to crushing load up to 571 lb/in 1 2 3 4 4 7 6 5
FEATURES
InArmor
+
MT FRP Dielectric
Multi-Tube (MT) FiberGlass Rods (FRP) Dielectric
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Maximum rated design tension — 1574-4496 lb Crush — 228 lb/in
Range
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144 Cable diameter, in 0.488...0.614 0.496...0.622 0.512...0.638 0.520...0.646 0.567...0.669 0.567...0.669 0.693 Cable weight, lb/ft 0.092...0.165 0.094...0.168 0.100...0.178 0.102...0.181 0.121...0.190 0.121...0.190 0.197 Minimum bending radius, in 7.323...9.213 7.441...9.331 7.677...9.567 7.795...9.685 8.504...10.039 8.504...10.039 10.394
Сlick here to see detailed
features of this design
In
Ar
mo
r
FEATURES
Maximum rated design tension — 1574 lb
Crush — 571 lb/in Fiber count up to 36 up to 48 up to 72 up to 96 Cable diameter, in 0.378 0.39 0.406 0.425 Cable weight, lb/ft 0.114 0.122 0.13 0.14 Minimum bending radius, in 5.669 5.846 6.083 6.378 1 2 3 4
DESIGN
1. Optical fiber2. Stainless steel tube filled with water-blocking gel 3. Armor of steel wires
4. Jacket
ADVANTAGES
Up to 96 fibers 100% waterproof Resistance to crushing load 571 lb/inMaximum rated design tension up to 2248 lb
InArmor
+
SST GSW
Stainless Steel Tube (SST) Galvanized Steel Wires (GSW)
Excellent rodent resistance
Maximum rated design tension — 2248 lb
Crush — 571 lb/in Fiber count up to 32 up to 48 up to 72 up to 96 Cable diameter, in 0.409 0.421 0.453 0.441 Cable weight, lb/ft 0.148 0.152 0.187 0.162 Minimum bending radius, in 6.142 6.319 6.791 6.614
Сlick here to see detailed
features of this design
62 In Ar mo r 62
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Aluminum and polymer tape
6. Inner jacket
7. Armor of galvanized steel wires 8. Jacket
ADVANTAGES
1 2 3 4 5 6 7 8 4Maximum rated design tension up to 17985 lb
With laminated aluminum polyethylene jacket – to protect the cable core from moisture
Resistance to crushing load up to 571 lb/in Excellent solution for wetland and cross-river installation
Aluminum compound tape to protect optical fiber from hydrogen penetration
InArmor
+
MT GSW Wetland
Multi-Tube (MT) Galvanized Steel Wires (GSW) Wetland
Maximum rated design tension — 1574...17985 lb Crush — 228 lb/in
Fiber count — up to 144
FEATURES
Excellent rodent resistance
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
Ar
mo
r
Maximum rated design tension — 6744–17985 lb Crush — 571 lb/in Fiber count — up to 24 1 2 3 4 5
DESIGN
1. Optical fiber2. PBT loose tube filled with water-blocking gel 3. Water-blocking gel or water-swellable yarns 4. Double armor of galvanized steel wires 5. Jacket
ADVANTAGES
Suitable for application in harsh environments Excellent rodent resistance Up to 24 fibers Maximum resistance to crushing load from 571 b/in
Maximum rated design tension up to 11240 lb
InArmor
++
CT GSW2
Central Tube (CT) Galvanized Steel Wires (GSW) Double Armor
FEATURES
Maximum rated design tension — 8992 lb Crush — 571 lb/in Range Fiber count up to 12 up to 16 up to 24 Cable diameter, in 0.504 0.508 0.52 Cable weight, lb/ft 0.252 0.258 0.27 Minimum bending radius, in 7.559 7.618 7.795
Сlick here to see detailed
features of this design
64 In Ar mo r
DESIGN
1. Optical fiber2. PBT loose tube filled with water-blocking gel 3. Water-blocking gel or water-swellable yarns 4. Double armor of fiberglass plastic rods 5. Jacket
ADVANTAGES
1 2 3 4 5 All-dielectric design Reduced weight and size. Convenient for blowing in tubes Suitable for application in harsh environmentsMaximum rated design tension up to 6744 lb
Resistance to crushing load from 571 lb/in
Excellent rodent resistance
InArmor
++
CT FRP2 Dielectric
Central Tube (CT) FiberGlass Rods (FRP) Double Armor Dielectric
FEATURES
Maximum rated design tension — 3372–6744 lb Crush — 571 lb/in
Fiber count — up to 24
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
Ar
mo
r
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Inner jacket
6. Double armor of galvanized steel wires 7. Jacket
ADVANTAGES
Suitable for application in harsh environments: in frozen soil, on the bottom of calm rivers and lakes
Maximum rated design tension up to 17985 lb Excellent rodent resistance Resistance to crushing load 571 lb/in 1 2 3 4 4 7 6 5
FEATURES
Maximum rated design tension — 17985 lb Crush — 571 lb/in
Fiber count up to 24 up to 48 up to 72 up to 96 up to 144
Cable diameter, in 0.772 0.787 0.819 0.835 0.913
Cable weight, lb/ft 0.537 0.573 0.608 0.630 0.800 Minimum bending radius, in 11.575 11.811 12.283 12.52 13.701
InArmor
++
MT GSW2
Multi-Tube (MT) Galvanized Steel Wires (GSW) Double
Armor Wetland
Сlick here to see detailed
features of this design
66 In Ar mo r
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Inner jacket
6. Double armor of fiberglass plastic rods 7. Jacket
ADVANTAGES
1 2 3 4 47 6 5 Suitable for application
in harsh environments: in frozen soil, on the bottom of calm rivers and lakes
Maximum rated design tension up to 8992 lb Excellent rodent resistance Resistance to crushing load from 571 lb/in All-dielectric design
FEATURES
Maximum rated design tension — 8992 lb Crush — 571 lb/in
Fiber count up to 24 up to 48 up to 72 up to 96 up to 144 Cable diameter, in 0.858 0.874 0.906 0.906 0.945 Cable weight, lb/ft 0.334 0.349 0.372 0.368 0.395 Minimum bending radius, in 12.874 13.11 13.583 13.583 14.173
InArmor
++
MT FRP2 Dielectric
Multi-Tube (MT) FiberGlass Rods (FRP) Double Armor Dielectric
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In Ar mo r 8
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Aluminum and polymer tape
6. Inner jacket
7. Double armor of galvanized steel wires 8. Jacket
ADVANTAGES
1 2 3 4 5 6 7 8 4FEATURES
Maximum rated design tension — 17985 lb Crush — 571 lb/in
Fiber count — up to 144
Maximum rated design tension up to 17985 lb
With laminated aluminum polyethylene jacket – to protect the cable core from moisture
Resistance to crushing load up to 571 lb/in Excellent solution for wetland and cross-river installation
Aluminum compound tape to protect optical fiber from hydrogen penetration
InArmor
++
MT GSW2 Wetland
Multi-Tube (MT) Galvanized Steel Wires (GSW)
Double Armor Wetland
Suitable for application in harsh environments
Excellent rodent resistance
Сlick here to see detailed
features of this design
68
In
Ar
mo
r
Rigit yet flexible enough to be installed into microducts
BlownIn
APPLICATION
OPERATING PARAMETERS
Operating temperature* -49°F...+158°F
Installation temperature -22°F...+122°F
Transportation and storage temperature -58°F...+158°F
Minimum bending radius 15×cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years
*Operating temperature range can be increased on request.
B low n In 1 2 3 4
DESIGN
1. Optical fiber2. Compact fiber unit (CFU) 3. Aramid yarns 4. Jacket
FEATURES
Operation tension, lb 34 Installation tension, lb 49 Fiber count up to 2 up to 4 up to 6 up to 8 up to 12 up to 24 Optical fiber (ITU-T Recommendation) G.657.A1 (250 μm) G.657.A1 (200 μm)Cable diameter, in 0.079 0.079 0.083 0.087 0.094 0.102
Cable weight, lb/ft 0.002 0.002 0.002 0.002 0.003 0.004
Operation tension, lb 67
Installation tension, lb 101
Fiber count up to 4 up to 6 up to 8 up to 12 up to 24
Optical fiber (ITU-T Recommendation) G.657.A1 (250 μm) G.657.A1 (200 μm)
Cable diameter, in 0.087 0.091 0.094 0.102 0.106
Cable weight, lb/ft 0.003 0.003 0.003 0.003 0.004
ADVANTAGES
Up to 24 fibers Reduced weight and size.
Convenient for microducts
Operation tension
up to 67 lb All-dielectric design
BlownIn CT
Central Tube (CT) design for blowing
Сlick here to see detailed
features of this design
70 B low n In
BlownIn MT 12
Multi-Tube (MT) with 12 fibers per tube
1 2 3 4 5
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. PBT loose tubes filled with water-blocking gel 4. Water-blocking gel or water-swellable yarns 5. Jacket
6. Steel wire
FEATURES
Option PE 250Outer jacket – PE (polyethylene) Fiber - G.652D + G.657.A1 (250 μm)
Fiber count up to 72 up to 96 up to 144 up to 192 up to 288 up to 432
Number of loose tubes 6 8 12 16 24 36
Number of fillers — — — 2 — —
Fibers per loose tube 12 0.634...0.705 0.650...0.720 0.669...0.740 0.693...0.764 0.732...0.803
Cable diameter, in 0.220 0.248 0.331 0.331 0.374 0.441
Cable weight, lb/ft 0.014 0.019 0.035 0.027 0.036 0.045
Operation tension, lb 67 112 202 124 146 225
Installation tension, lb 225 337 629 360 427 674
ADVANTAGES
Up to 432 fibers Easy to install
Operation tension
up to 67-225 lb All-dielectric design
Сlick here to see detailed
features of this design
B
low
n
In
Option PA 250
Outer jacket – PA (polyamide) | Fiber - G.652D + G.657.A1 (250 μm)
Fiber count up to 72 up to 96 up to 144 up to 192 up to 288 up to 432
Number of loose tubes 6 8 12 16 24 36
Number of fillers — — — 2 — —
Fibers per loose tube 12 0.634...0.705 0.650...0.720 0.669...0.740 0.693...0.764 0.732...0.803
Cable diameter, in 0.201 0.232 0.311 0.311 0.354 0.421
Cable weight, lb/ft 0.012 0.017 0.031 0.023 0.032 0.041
Operation tension, lb 67 112 202 124 146 225
Installation tension, lb 225 337 629 360 427 674
Option PA 200
Outer jacket – PA (polyamide) | Fiber - G.652D + G.657.A1 (200 μm)
Fiber count up to 72 up to 96 up to 144 up to 192 up to 288 up to 432
Number of loose tubes 6 8 12 16 24 36
Number of fillers — — — 2 — —
Fibers per loose tube 12 0.634...0.705 0.650...0.720 0.669...0.740 0.693...0.764 0.732...0.803
Cable diameter, in 0.177 0.201 0.260 0.264 0.311 0.366
Cable weight, lb/ft 0.009 0.012 0.017 0.018 0.028 0.032
Operation tension, lb 56 77 135 90 202 180
Installation tension, lb 169 214 337 247 539 495
Option PA 200 Reduced design
Outer jacket – PA (polyamide) | Fiber - G.652D + G.657.A1 (200 μm)
Fiber count up to 12 up to 24 up to 36 up to 48
Number of loose tubes 1 2 3 4
Number of fillers 5 4 3 2
Fibers per loose tube 12
Cable diameter, in 0.142
Cable weight, lb/ft 0.007
72 B low n In
BlownIn MT 24
Multi-Tube (MT) with 24 fibers per tube
1 2 3 4 5
DESIGN
1. Central strength member (FRP) 2. Optical fiber
3. Gel-filled loose tube 4. Water-swellable yarns 5. Jacket
FEATURES
Option PA 200Outer jacket – PA (polyamide) Fiber - G.652D + G.657.A1 (200 μm)
Fiber count up to 144 up to 192 up to 288
Number of loose tubes 6 8 12
Number of fillers — — —
Fibers per loose tube 24
Cable diameter, in 0.209 0.244 0.315
Cable weight, lb/ft 0.013 0.016 0.029
Operation tension, lb 67 67 157
Installation tension, lb 225 225 495
ADVANTAGES
Up to 288 fibers Easy to install
Operation tension
up to 67-157 lb All-dielectric design
Сlick here to see detailed
features of this design
In
Ar
mo
Applied in sea areas (coastal shelf and deep-sea), on navigable rivers, in lakes and water storage basins, in harsh environments, in bogs and unnavigable rivers.
InWater
APPLICATION
OPERATING PARAMETERS
Operating temperature* -58°F...+158°F Installation temperature -22°F...+122°FTransportation and storage temperature -58°F...+158°F
Minimum bending radius 15×cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years
*Operating temperature range can be increased on request.
In Wa te r 1 2 3 2 4 5 6 7 2 4 8
InWater Submersible CT GSW2
Central Tube (CT) Galvanized Steel Wires (GSW) Double Armor
DESIGN
1. Optical fiber 2. Water-blocking gel 3. Loose tube 4. Armor of steel wires 5. Water-swellable tape 6. Aluminum and polymer tape 7. Inner jacket8. Jacket
ADVANTAGES
FEATURES
Maximum rated design tension — 4496...15737 lb Crush — 857 lb/in
Fiber count — up to 24
Installation down to 8202 ft
Suitable for application in harsh environments
Сlick here to see detailed
features of this design
76 In Wa te r 1 2 3 2 4 5 6 7 2 4 8
DESIGN
1. Optical fiber 2. Water-blocking gel 3. Steel tube 4. Armor of steel wires 5. Water-blocking tape 6. Aluminum and polymer tape 7. Inner jacket8. Jacket
ADVANTAGES
Installation down to 16404 ftSuitable for application in harsh environments
InWater Submersible SST GSW2
Stainless Steel Tube (SST) Galvanized Steel Wires (GSW)
Double Armor
Up to 48 fibers in a tube
Maximum rated design tension — 4496...19109 lb Crush — 857 lb/in
Fiber count — up to 96
FEATURES
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications — [email protected]
Сlick here to see detailed
features of this design
In
Wa
te
Designed for aerial installations: on power lines, lamp posts, between buildings and structures. Suitable for aerial installation on transmission equipment and power facilities in dielectric package
InAir Figure 8
OPERATING PARAMETERS
Operating temperature* -58°F...+158°F
Installation temperature -22°F...+122°F
Transportation and storage temperature -58°F...+158°F
Minimum bending radius 15×cable diameter
Life time 25 years
Warranty as specified in the supply
agreement, min 2 years *Operating temperature range can be increased on request
We design cables based on our Customers' specific technical requirements.