SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice. SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.

Distributed by

(2)

After serving for over 30 years as the feet of global villagers,

the former LG Elevators and Escalators of LG Industrial Systems Co.,Ltd. lives on with the birth of Sigma Elevator Company.

On the basis of time-tested and valuable expertise, our everlasting ardor for customer satisfaction under the banner of "New Technology," Perfect Quality," and "Best Services" will be sustained by SIGMA Elevator

in the new millenium.

(3)

We are proud to introduce a new generation of escalators with our SCE series.

Sigma Commercial Escalators are well suited for today’s urban structures. New technological

advancements have been applied to make the escalators the world-best in design and safety.

New technology and aero-dynamic design make Sigma escalators appealing while improved

strength and safety features offer security to users.

Manufactured by the Changwon factory in Korea, Sigma escalators will continue to meet

stringent customer requirements with higher goals than expected.

With certificates to meet various standards around the world, we offer the best quality and

safety with Sigma escalators.

(4)

Micom Controller

Fault Code Display (LED) Traffic Information Display Interface Double Coil Brake

Lower Starting Shock (Y-¡ start) Remote Monitoring Interface

W orm

Helical

M a chine

High Efficiency Low Noise Reliable Brake System Safety Provisions Compact

Vertical worm helical machine Compact design

Efficient maintenance

New Technology

Better world with Sigma Escalators...

Artistic design, best safety and best ride.

N ew concept of engineering resulting safe

and low noise SIGMA Escalator .

A different escalator...

Maintenance Ro o m

Clear area expanded

(EN Code applied)

R o bust

Strength with the comfort and

Design

Artistic design with smooth

Safety

(5)

Aero-Dynamic Design

Silver(Option) Black

Blue

Clear Green(Option) Bronze(Option)

Aluminium Aluminium(Option) Stainless steel

Direction indicator

Various colors for

handrails

Ebony(Black) ES-01 Scarlet ES-10(Option) Sapphire ES-27(Option) Crimson ES-20(Option) Mid Grey ES-12(Option) Emerald ES 29(Option)

Unique SIGMA escalator design and various

design options make possible assimilation with

building aesthetics.

Simple and yet, modern design of handrail inlet coupled with slim deck line lamp raised escalator design to the next level while maintaining safety

Glass panel

3 Types of Entry Box

Floor

(6)

Robust

One-body step

One-body steps from step die casting machine

Skirt guard

Triple reinforced structure

Demarcation cleat

Reinforced to prevent breakage

Aluminium mold

Strong aluminium mold

Perfection of strength and sturdiness...

From angle truss to high torsion resisting 4 angled pipe truss...

One-body Step escalator die casting machine Hardness enhanced to prevent fractures

(7)

Safety measures surpass EN115 of Europe!

User safety comes first in SIGMA escalators

Controller Lifting Device Comb Plate Switch Safety Guard at upper and lower machine rooms

Step Safety Switch Lock/Tag-out Switch Entry Switch Skirt Guard Safety Device Driving Chain Safety Device

Step Roller Safety Device Step Chain Safety Device Emergency Stop Device / Operation Monitoring LED

Expanded Maintenance Area

Gap between step and skirt guard

Surpassed EN Code requirements

Entry box

Handrail inlet engineered through mock emergency tests

Handrail

Engineered to prevent fingers getting caught between frame and handrail

(8)

Structure and Safety Device

New Generation Escalator

Self-diagnostic functions with remotecommunication

Engineered through field know-how

Advanced safety system with robust design

Emergency Stop Device & Operation Monitoring(LED)

In an emergency, stops the escalator immediately if pressed. Operation Monitoring LED

Flickering : requires removal of foreign material and re-start by site managers

On : requires repair by maintenance personnel Step Safety Switch Stops escalator if steps are operating in abnormal manner due to fractured step

Step Chain Safety Device Stops escalator if the step chain breaks or becomes loose. Skirt Guard Safety Device Stops escalator if objects are caught between step and skirt

Controller Lifting Device For easy removal of controller during maintenance

Driving Chain Safety Device

Stops escalator if the driving chain breaks or excessively loosened

Comb Plate Safety Switch Stops escalator if objects are caught between comb plate and step treads.

Entry Switch

Stops escalator if hand or object is pulled into the handrail inlet

Step Roller Safety Device

Stops eacalator if steps are operating in abnormal manner due to reasons such as foreign matters being caught between steps.

Non-reversing Safety Device Stops escalator if its direction of travel is reversed

Additional option safety devices

Overspeed Detector

Stops escalator if operating above normal speed Auxiliary Brake

Stops escalator if the driving chain breaks or over-speeds Brake Lining Wear Safety Device

Stops escalator if the lining of main brake is worn abnormally Handrail Speed Detector

Stops escalator if handrail speed is below norm due to handrail breakage or elongations Handrail Stop Device

Stops escalator if handrail breaks or stops Handrail Static Preventor

Prevents static electricity with handrail rollers installed blocking static electricity

HANDRAIL DECK GLASS PANEL DRIVING UNIT STEP COMB CONTROLLER TRUSS RAIL

HANDRAIL DRIVING PULLEY

SKIRT GUARD

EMERGENCY STOP DEVICE

FLOOR HANDRAIL ENTRY BOX

(9)

   K

600

FL. FL.

FL. FL.

Layout & Dimensions

Specification

From material to manufacturing engineering, research works are unified and focused to enhance our escalator technology.

FINISHED FLOOR

WORKING POINT  WORKING POINT 

L=L1+A+B+100 MIN.M    H    (    R    I    S    E    )        J    M    I    N .    K D    8    0    0    J    H    (    R    I    S    E    )    K FL. FL. FL. L1=(30 =1.732 H,35 =1.428 H) RAILING (BY OTHERS) (BY OTHERS) EXTERIOR PANEL W.P POWER SUPPLY F W.P R1 R2 W2 W1 W3 MIN.PIT WIDTH    M    I    N .    P    I    T    D    E    P    T    H FINISHED FLOOR W 2     0    0     G     E     GUARD AT CEILING    M    I    N .    2    3    0    0 C 50 600 A B 50 (BY OTHERS) FINISHED FLOOR (BY OTHERS)    T

Support Loads

Through product developmen t focused on safety and comfort, travel ing up or down in buildings or department stores is safe, quick and convenient.

Angle of inclination SCE 30 SCE 35 SCE 30 SCE 35 30 35 30 35 2 2 1.5 1.5 2050~6000 2050~6000 2050~6500 2050~6500 R1(kg) 0.64H + 2500 0.52H + 2800 0.64H + 2100 0.52H + 2600 R2(kg) 0.64H + 1900 0.52H + 2300 0.64H + 1500 0.52H + 2100 R1(kg) 0.80H + 3100 0.67H + 3400 0.76H + 2800 0.67H + 3000 R2(kg) 0.80H + 2500 0.67H + 2800 0.76H + 2400 0.67H + 2300 Type Load Model

No.of Flat Step Rise 800 Type 1200 Type

270 50    1    4    0 140 320

(Concrete Support Structure)

250 250 140 140 50 50 MIN.300 MIN.300 MIN.200 MIN.200    1    4    0    1    4    0 (unit : mm)

Frame Support

FINISHED FLOOR(BY OTHERS)

BASE PLATE

BASE PLATE

BASE PLATE STEEL BAR(BY OTHERS)

SUPPORT PLATE (BY OTHERS)

BASE PLATE SUPPORT PLATE

(BY OTHERS) STEEL BAR(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

RIB(BY OTHERS) RIB(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

320 140    1    4    0 270 50

(Steel Beam Support Structure)

LOWEREND UPPEREND

LOWEREND UPPEREND

When H is above 6,000mm, consult Sigma for further details. When L is over 16,000mm, an intermediate support is required. For no intermediate support and when L is over 16,000mm, consult Sigma for further details

Given dimensions may change without advance notice

Model Type Dimension 2050 ~ 6500 2050 ~ 6000 2050 ~ 6000 2050 ~ 6000 800 1200 2215 2215 2915 2415 2290 2290 2990 2490 1945 2145 2020 2220 1665 1865 1740 1940 1395 1595 1470 1670 730 730 730 730 30 30 35 35 950 950 950 950 1020 1020 1020 1020 1100 1100 1100 1100 2300 2300 2000 2000 1.5 2 1.5 2 Rise(H) No.of Flat Step SCE30 SCE30 SCE35 SCE35 unit : mm

Dimensions

A B C D E

E:Incase of EN115 compliance, E is 800mm

F G J K M

Model Type

Dimension

2050 ~ 6000 Rise(H) SCE30 & SCE 35

StepWidth W W1 W2 W3 800 604 1200 1004 800 609 1200 1009 800 820 1200 1220 800 1150 1200 1550 800 1250 1200 1650

(10)

References

Related documents

Although the SIMPLER method by using hybrid and power law differencing schemes also give acceptable results for low Reynolds numbers in the backward-facing step problem when

4) Adjust the binary image level by pushing the UP or DOWN keys so that cross lines appear on Pupil image. Make the subject see upper right, upper left, lower right and

The performance indices of the transition behaviour of the two closed loop systems of this investigation are shown in Table 1. It can be observed from the simulation results

According to the Target Company’s Securities Registration Statement, Etc., the Target Company resolved, at the Board of Directors meeting of the Target Company

For instance, men who report a nonmarital birth in the NSFG may be disproportionately likely to be in coresidential unions at either their first or second births compared to a more

USB Port: One for an Infinity model IN-USB2 or IN-USB1 USB Foot Pedal or for a model IN-DB9 Serial Foot Pedal when used with a Serial-To-USB-Converter.. Serial Port: One if using

,n the case at the case at bar bar* * the Supre the Supreme Court agree me Court agreed d wi with th the peti the petitio tioner ners s tha that t mer mere e

Bei einer Reizrate von 100/s waren die Unterschiede zwischen den Nachweiszeiten der Vigilanzzustände „wach“ und „schlafend“ signifikant (p << 0,01). Die Unterschiede