• No results found

Copper Meter Resetters

N/A
N/A
Protected

Academic year: 2021

Share "Copper Meter Resetters"

Copied!
16
0
0

Loading.... (view fulltext now)

Full text

(1)

Copper

Meter

Resetters

To Set 5/8", 5/8" x 3/4", 3/4",

(2)

Table of Contents

Page

Meter Resetters - 5/8", 5/8" x 3/4", 3/4", & 1"

Horizontal Inlet and Outlet

Series 710

General Information ...4-5

Series 717

Low Rise Style ... 6

Series 718

Horizontal Style ... 7

Series 719

Vertical Style - Meter Thread x Meter Thread ... 8

Series 768

Horizontal "F" Style - Flexible ... 9

Series 758

Crab Style Tandem ...10

Inverted Tandem ...10

Inline Tandem ...11

Page

Meter Resetters - 1

1

2

" & 2"

Vertical Inlet and Outlet

Series 718

No Bypass ...12

With Bypass ...13

Accessories

Gaskets ...14

Meter Bushings / Adapters ...14

Meter Dimensions ...14

Tandem Options ...15

Sectional View ...15

Page 6

710 Series

717-204XDCA

Series 717 with Backflow Preventer and Thermal Expansion Tank (Tank

must be purchased separately).

717-204XDCC

Series 717 used to retrofit existing high rise meter pit and standard meter resetter with backflow preventer and pressure relief valve.

Page 4-5

Page 7

718 Series

(3)

A.Y. McDonald Mfg. Co. Resetters offer a wide variety of options for resetting your current water meter to various heights and

locations. Resetters are used where the meter is already installed and the service lines are in place, but the meter needs to be

relocated above or next to the current line. A.Y. McDonald Mfg. Co. resetters provide you with an array of variations that will

see you through any relocation project.

Common resetter installations are shown below. You can customize your resetter solution on the pages within, or contact our

factory professionals to help you through.

BEFORE

AFTER

General Information

- Brass materials meet or exceed AWWA C-800 (latest revision)

- Copper tubing has a

13

16

" O.D. for 5/8", 5/8" x 3/4" or 3/4"

meter resetters, 1

1

8

" O.D. for 1" meter resetters, 1

5

8

" for

1

1

2

" meter resetters and 2

1

8

" for 2" meter resetters.

- Solder is no-lead.

- EPDM rubber gaskets are furnished as standard. Contact

factory for fiber or leather gaskets.

- All meter resetters are factory tested air under water at 85 PSIG.

- Brass support bar is standard on 18" and higher meter resetters.

- Meter resetter heights over 24" available on special order.

- All meter swivel nuts have wire seal hole.

- Lockwing ball style meter valves are standard.

- Meter swivel nuts with meter support saddle are standard,

except where noted.

- All copper meter resetters can be supplied with a test valve

on the outlet tubing.

- For dual check backflow valves, see catalog section 13.

- Brace eye hole accepts 1/2" iron pipe or PVC for 5/8",

5/8" x 3/4" and 3/4" meters and 1" vertical meter resetters.

- Brace eye hole accepts 3/4" iron pipe or PVC for 1", horizontal

meter resetters.

- Brace eye hole accepts 1" iron pipe or PVC for 1

1

2

" & 2",

(4)

The A.Y. McDonald Meter Resetter is a unique and patented product designed to easily retrofit existing meter installations to

include a dual check backflow preventer, or pressure relief valve. This is accomplished without the high risk of cutting into old

service lines, or the expensive process of digging up and replacing existing meter boxes or pits. This retrofitting can be easily

performed in even the most confined meter boxes.

ASSE listed dual check

Patent No. 4,691,727

Meter Dimensions

After

NOTE: Meter box sold separately

Meter Threads Cast Brass Base

Meter Threads Dual Check Backflow Preventer (optional)

Copper Tubing

Available for 5/8", 5/8" x 3/4", or 3/4" meters

Before

NOTE: Meter box sold separately

Cast Brass Meter Nuts with Rubber Gaskets

METER SIzE 5/8" 5/8" x 3/4" 3/4"

A-Meter Threads 3/4" 1" 1"

B-Lay Length 712" 712" 9"

A.Y. McDonald Spacing* 71316" 71316" 9516"

Copper Meter Resetters

0 5 10 15 20 25 30 0 5 10 15 20 0 2.5 5 7.5 10 30 25 20 15 10 5 0 20 15 10 5 0 20 15 10 5 0 3/4" Series 710 without backflow 5/8" x 3/4" Series 710 without backflow

3/4" Series 710 with backflow 5/8" x 3/4" Series 710

with backflow 5/8" Series 710 without backflow

5/8" Series 710 with backflow

WA TER FLO W (Gallons Per Minute) WA TER FLO W (Gallons Per Minute) WA TER FLO W (Gallons Per Minute)

PRESSURE DROP (Pounds per Square Inch) PRESSURE DROP (Pounds per Square Inch) PRESSURE DROP (Pounds per Square Inch)

THERMAL EXPANSION WARNING - Creating a “closed” condition in a hot water system with the installation of a non-return barrier (such as a Check Valve or

Backflow Preventer between the system piping and the public supply) can result in extreme pressure rises caused by thermal expansion and/or water hammer. This thermal expansion can damage piping, valves, and other components in the system. The installation of a pressure relief device or thermal expansion tank can avoid possible damages.

710 SERIES

(5)

Series Style Meter Size Meter Height Meter Connections Bottom Bar 1/2" FNPT Space Tube Offset Options Bottom Bar Tap 710 – = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" R = Right offset 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 3" 6" 7" 12"

OPTIONS

- Resetters with cross-over meter sizes are available, contact factory. * For angle ball valves integral to resetter, contact factory.

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

– = No tap

A = Tap inlet, no plug B = Tap outlet, no plug D = Tap outlet, with 125# PRV E = Tap inlet, with 175# PRV F = Tap outlet, with 175# PRV G = Tap inlet, with plug H = Tap outlet, with plug L = Tap inlet, with 125# PRV

(Inlet is city side, outlet is house side)

X72

-N

N

06

1

-See above side view as required

710

Model 710-103NN - - X72

Offset Left Standard

Model 710106NN

-Side View 72° Left Offset Standard Side View – = No option C = Dual check on inlet H = Dual check on outlet J = Adapter idler on outlet

(sized to fit meter)

U = UFR on outlet (Integral) Approx. 6” Approx. 3” A B Tap Locations Inlet Inlet A B Tap Locations

*

N = No valve

(meter nut only without saddle)

Q = Lockwing ball valve

(without saddle)

Dual Check Backflow Preventer (Inlet side)

711-3AN 34

For 5/8" meter

711-3AN 44

For 5/8" x 3/4" and 3/4" meter

Inlet: Male meter thread

Outlet: Female meter thread (union)

Dual Check Backflow Preventer (Outlet side)

711-3NA 43

For 5/8" meter

711-3NA 44

For 5/8" x 3/4" and 3/4" meter

Inlet: Female meter thread (union)

Outlet: Male meter thread

Pressure Relief Valve

710P125

125 lb. rated

710P175

175 lb. rated - 1/2" MNPT thread

Plug

73208 1/2”

710J11

Meter Adapter Idler (New Style)

3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 712" lay length - 5/8" meter

710J22

Meter Adapter Idler

3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 7" lay length - 5/8" x 3/4" meter

710J23

Meter Adapter Idler

112" long with gasket. Use with

710 Series unit and backflow preventer to increase lay length - 3/4" meter

710 SERIES

(6)

Low Rise Style Resetter

90º tubing to bottom bar is standard, contact factory for other options.

The A.Y. McDonald 717 Series low rise resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check

valve. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Ninety

degree tubing to bottom bar is standard, other options are available (contact factory for information).

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Optional Offset

Tap Location Bottom Bar Tap 717 – = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" Offset Left: U = 5/8" V = 5/8" x 3/4" W = 3/4" X = Offset Left 1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1" 4" 6" - for 1" meter only. For special heights, contact factory. – = No tap A = 1/2" FNPT - no plug

B = 1/2" FNPT - with brass square

head plug

C = 1/2" FNPT - 125# PRV D = 3/4" FNPT - no plug

(only 1" resetter)

E = 3/4" FNPT - with brass square

head plug (only 1" resetter)

-D

W

04

2

-717

– = No Tap A = Inlet Left B = Outlet Left C = Outlet Top D = Outlet Bottom

C = Angle single check valve on outlet

D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve

X = No valve - meter nut only

For other special meter connections, contact factory.

Series 717 is typically viewed from the inlet side, and is fabricated as a “right offset” (see photo above and at right). This is critical when considering tap locations. Left offset is available upon special request - contact factory.

Tap A Inlet

(city side) (house side)Outlet

Tap D - (top) Tap C (bottom) Tap B Tap A Inlet (city side) Tap C - (top) Tap D (bottom) Tap B

Left Offset

Right Offset

Outlet (house side)

INLET Meter Thread

(7)

Horizontal Style Resetter

Minimum 10" height on 1" resetters, or 12" on 1" resetter with angle dual check.

The A.Y. McDonald 718 horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve

while offering several height options. It also offers several options for taps to incorporate pressure relief valves or sampling valves

before or after the meter. Depending on valve configurations, minimum heights may vary.

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT

Tap Location Bottom Bar Tap 718 – = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1" 07" 09" 10" 12" 15" 18" 21" 24" For special heights,

contact factory.

Blank = No Tap A = 1/2" FNPT - no plug B = 1/2" FNPT - with brass

square head plug

C = 1/2" FNPT - 125# PRV D = 1/2" FNPT - 175# PRV

-X

W

07

2

-718

Blank = No Tap A = 1/2" FNPT inlet B = 1/2" FNPT outlet

C = Angle single check valve on outlet

D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve

X = No valve - meter nut only

For other special meter connections, contact factory.

Model 718207WX

-INLET

Meter Thread Meter ThreadOUTLET

For Tandem Series

Example 758-207WX

Tandem resetters are supplied with adapters and “S” tube. Please specify device length and threads when ordering.

(8)

Vertical Style Resetter - Meter Thread x Meter Thread

The A.Y. McDonald 719 vertical to horizontal resetter allows you to reset a meter currently in a vertical position to a horizontal

position incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and several options for

taps to incorporate pressure relief valves or sampling valves before or after the meter.

- Meter swivel nuts are less saddle

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Model 719-2

Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT

Tap Location Bottom Bar Tap 718 – = Standard

For crossed sized meter sets

A = 5/8" B = 5/8" x 3/4" C = 3/4" 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" – = Standard

For special heights, contact factory.

Blank = No Tap

A = 1/2" FNPT - no plug B = 1/2" FNPT - with brass

square head plug

C = 1/2" FNPT - 125# PRV D = 1/2" FNPT - 175# PRV

-N

Q

--2

-719

Blank = No Tap A = 1/2" FNPT inlet B = 1/2" FNPT outlet

A = Angle single check valve on outlet

F = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valve

N = No valve - meter nut only

For other special meter connections, contact factory.

(9)

Horizontal "F" Style Flexible Resetter

Minimum 15" height on 1" resetters. Resetters with cross-over meter sizes are available, contact factory.

The A.Y. McDonald 768 horizontal “F Style” (Flexible) resetter allows you to reset a meter incorporating an inlet or outlet shut off

valve or check valve. It also offers several height options and flexibility if existing set is not aligned correctly.

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Series Style Meter Size Meter Height Inlet Outlet

Meter Connections 768 – = Standard

For crossed sized meter sets

A = 5/8" B = 5/8" x 3/4" C = 3/4" 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" 12" 15" 18" 21" 24" For special heights, contact factory.

X

W

12

1

-768

C = Angle single check valve on outlet (Not availabe on 1") D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve

X = No valve - meter nut only

For other special meter connections, contact factory.

Model 768-112WX

For Tandem Series

Example 761-112WX

Tandem resetters are supplied with adapters and “S” tube. Please specify device length and threads when ordering.

761 Series Horizontal Tandem Setter INLET

Meter Thread Meter ThreadOUTLET

(10)

Crab Style Tandem Resetter

Made to set two 7

1

2

" meter thread x meter thread devices.

The A.Y. McDonald 758 tandem resetter allows you to reset a meter and a device in one low profile compact setting.

- Meter swivel nuts are less saddle

For installing a regulator and meter in an existing setting and there is little room above 2" rise from original meter height. The A.Y.

McDonald 758 inverted tandem resetter allows you to reset a meter and a device with minimal rise as long as there is room below

the existing meter.

- Meter swivel nuts are less saddle

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Series Style Meter Size Meter Height Meter Connections Blank Space Crab Style

Series Style Meter Size Meter Height Meter Connections Blank Space Inverted Style

758 Tandem 758 Tandem – = Standard – = Standard 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4"

For special heights, contact factory.

For special heights, contact factory.

X419

X406

N

N

N

N

--02

2

2

-758

758

N = No valve - meter nut only

For other special meter connections, contact factory.

N = No valve - meter nut only

For other special meter connections, contact factory.

Model 758-2--NN X419

Model 758-202NN X406

758 SERIES

Inverted Tandem

(11)

Inline Tandem Resetter

The A.Y. McDonald 758 inline tandem re-setter with additional options for shut off or check valves plumbed into the tubing to accept

inline, a meter and a pressure regulating device. Please supply device length and end connection configuration when ordering.

- Resetters include 74620 meter coupling and 74619 adapter and gaskets.

- Meter swivel nuts are less saddle

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Series Style Meter Size Meter Height Meter Connections Blank Space Flange to

Flange Spread 758 – = Standard 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" 07" 09" 10" 12" 15" 18" 21" 24" For special heights,

contact factory.

X15.81

N

Q

07

2

-758

A = Angle single check valve on outlet

F = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valve

N = No valve - meter nut only

For other special meter connections, contact factory.

Model 758-207QN X15.81

INLET

Meter Thread Meter ThreadOUTLET

(12)

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Horizontal Style Resetters 1

1

2

" & 2" - No Bypass

1" Copper cross tube is standard for no by-pass setters.

The A.Y. McDonald 718 1

1

2

" and 2” oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut

off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate

pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary.

Brass eye holes accept 1" iron pipe or 1" PVC.

Series Style Meter Size Meter Height Inlet Outlet

Meter Connections 718 – = Standard No Bypass 6 = 1 12" 7 = 2" 15"18" 21" 24" For special heights, contact factory. Minimum height may apply based on configuration of setter.

D

W

18

6

-718

D = Angle dual check valve

E = Angle dual check valve with 1" tap in cap with

1" NPT plug assembly

F = Angle dual check valve with 112" tap in cap

with 112" NPT plug assembly

G = Angle dual check valve with 2" tap in cap with

2" NPT plug assembly

N = Flanged elbow

T = Flanged tee with 2" plug in top of tee for access W = Angle lockwing ball valve

Model 718-618WD

For Tandem Series

Example 758-618WD

Tandem resetters are supplied with 610M adapters and “S” tube. Please specify device length and threads when ordering.

758 Series Tandem

Setter

INLET

Meter Flange Meter FlangeOUTLET

718 SERIES

(13)

OPTIONS

- Not all combinations available, contact factory with your requirements. - MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.

- Please verify with the factory that the model number you have configured is available and meets your requirements.

Copper Meter Resetters

Horizontal Style Resetters 1

1

2

" & 2" With Bypass

The A.Y. McDonald 718 1

1

2

" and 2" oval flanged horizontal resetter allows you

to reset a meter incorporating an inlet or outlet shut off valve or check valve

while offering several height options. It also offers bypass options and several

options for taps to incorporate pressure relief valves or sampling valves before or

after the meter. Depending on valve configurations, minimum heights may vary.

- Brass eye holes accept 1" iron pipe or 1" PVC

- 2" Meter flanges have slotted bolt holes to fit 1

1

2

" or 2" meters

- Two drop in flange gaskets furnished.

- Two meter support brackets furnished.

- 1¼" bypass includes a 1" x 1" x 1

1

4

" ball valve.

- Resetter with bypass requires a check valve or ball valve on outlet

- Cross sized resetters available, contact factory.

Series Bypass Meter Size Meter Height Inlet Outlet

Meter Connections 718 6 = 112" 7 = 2" 12"15" 18" 21" 24" For special heights, contact factory. Minimum height may apply based on configuration of setter.

D

W

18

6

B

718

D = Angle dual check valve

E = Angle dual check valve with 1" tap in cap with

1" NPT plug assembly

F = Angle dual check valve with 112" tap in cap

with 112" NPT plug assembly

G = Angle dual check valve with 2" tap in cap with

2" NPT plug assembly

N = Flanged elbow

T = Flanged tee with 2" plug in top of tee for access W = Angle lockwing ball valve

B = Low bypass R = High Offset

Model 718B618WD

For Tandem Series

Example 758-618WD

Tandem resetters are supplied with 610M adapters and “S” tube. Please specify device length and threads when ordering.

758 Series Tandem

Setter INLET

Meter Flange Meter FlangeOUTLET

B = Low Bypass

6.50”

Setter Height

R = High Ofset Bypass

612” to right of meter

(14)

Copper Meter Resetters

*Allows for meter and two gaskets.

Note: A.Y. McDonald uses the above standards for typical meter applications. If your application is special or in question, you should always measure the meter as shown above.

Other meter lay lengths must be specified. An additional 3/8" is added to top spacing to allow for gaskets: Standard 2" top spacing = 1738".

Oval Flange

Meter Size

5/8"

5/8" x 3/4"

3/4"

1"

1

1

2

" 2"

A-Meter Threads

3/4" 1" 1" 114" 112" 2"

B-Lay Length

712" 712" 9" 1034" 13" 17"

A.Y. M

c

Donald Spacing*

71316" 71316" 9516" 11332" 13.38" 17.38"

2" Meter Flanges have slotted bolt holes to fit 112" or

2" meters.

Two drop in flange gaskets furnished.

Two meter support brackets furnished.

Gaskets

10J12 - Converts 5/8" meter spud to 5/8" x

3/4" meter spud - two pieces required per meter

10J12KIT - Converts 5/8" meter spud to 5/8" x

3/4" meter spud - two pieces per bag

10J45 - Converts 1" meter spud to

114" meter spud - two pieces

required per meter Changes thread

size only

Meter Bushings

Meter Dimensions

METER

MODEL DESCRIPTION SIzE

18-G1 5/8" Rubber 5/8" 18-G1F 5/8" Fiber 5/8" 18-G1L 5/8" Waxed Leather 5/8" 18-G2 3/4" Rubber 5/8" x 3/4" or 3/4" 18-G2F 3/4" Fiber 5/8" x 3/4" or 3/4" 18-G2L 3/4" Waxed Leather 5/8" x 3/4" or 3/4" 18-G4 1" Rubber 1" 18-G4F 1" Fiber 1" 18-G4L 1" Waxed Leather 1" METER

MODEL DESCRIPTION SIzE

18-G6 112" Flange-Rubber 112"

18-G7 2" Flange-Rubber 2" 4620G 112" Round-Rubber 112"

4620G 2" Round-Rubber 2"

Converts meter size and laying length

710J13 - Converts 5/8" meter to 3/4" meter - two pieces required per meter

710J13KIT - Converts 5/8" meter to 3/4" meter - two pieces

per kit

710J14 - Converts 5/8" meter to 1" meter - two pieces required per meter

710J14KIT - Converts 5/8" meter to 1" meter - two pieces

per kit

710J23 - Converts 5/8" x 3/4" meter to 3/4" meter - one piece required per meter

710J24 - Converts 5/8" x 3/4" meter to 1" meter - two pieces required per meter

710J24KIT - Converts 5/8" x 3/4" meter to 1" meter - two

pieces per kit

710J34 - Converts 3/4" meter to 1" meter - two pieces required per meter

710J34KIT - Converts 3/4" meter to 1" meter - two pieces

per kit

710J46 - Converts 1" meter to 112" flanged meter size

and length - two pieces required per meter

710J46KIT - Converts 1" meter to 112" flanged meter size

and length - two pieces per kit

710J47 - Converts 1" meter to 2" flanged meter size and length two pieces required per meter

710J47KIT - Converts 1" meter to 2" flanged meter size and

length two pieces per kit

710J67 - Converts 112" flanged meter to 2" flanged meter size

and length - two pieces required per meter - two bolts included

710J67KIT - Converts 112" flanged meter to 2" flanged meter size

and length - two pieces per kit - four bolts included

710J67DH - Converts 112" flanged meter to 2" flanged meter

size and length - two pieces required per meter Slotted holes for 112" or 2" meters - does not include

bolts and nuts

710J77DHX2 X1.75

- Converts 2" x 15.25" flanged meter to 2" x 17" flanged meter size and length -one piece required per meter. Slotted holes for 112" or 2" meters - does

not include bolts and nuts

6121 - Meter support bracket - 112" and 2"

(15)

Copper Meter Resetters

All A.Y. M

c

Donald tandem copper setters are designed to provide the user with the option of placing an auxiliary device in addition to

a water meter in a space as small as 18" in diameter (see Table I). The auxiliary device could be a pressure regulator, pressure relief

valve, backflow preventer, etc. Table I shows typical lay lengths available for these devices. Other lengths can be provided. Contact our

customer service department for details.

- Standard centerline spread for 5/8", 5/8" x 3/4", 3/4" meters is 7". 1" meter is 9".

- Tandem meter setter “S” bar (4619S-size) and brass adapters (74619-size)

come as standard when ordering tandem resetters, but are also available

separately (see below). Contact factory.

- Resetters with cross-over meter sizes are available, contact factory.

4619S 5/8"

- for use with 5/8" meter tandem

4619S 5/8" x 3/4" - for use with 5/8" x 3/4" meter tandem

4619S 3/4"

- for use with 3/4" meter tandem

Above items for use with 4"-5" device

4619S 1

- for use with 1" meter tandem

Above item for use with 5"-6" device

74619 5/8" - (5/8" meter x 3/4" NPT)

74619 3/4" - (5/8" x 3/4" or 3/4" meter x 3/4" NPT)

74619 1" - (1" meter x 1" NPT)

Two pieces required per device

7"

9"

Spread for 5/8", 5/8"x 3/4" and 3/4" Meters

Spread for 1" Meters

Note: Special length cross tubes and inverted tandem

cross tubes are available, contact factory.

Tandem "S" Bar

"S" Bar Adapter

TABLE I

Device Minimum

Meter Size Length Recommended

(FNPT x FNPT) Inside Pit Diameter

5/8"

4" to 5"

18"

5/8" x 3/4"

4" to 5"

18"

3/4"

4" to 5"

20"

1"

5" to 6"

21"

Tandem Options

Sectional View

Angle Meter Valve Ball Style

Test Valve in Tubing

Angle Dual Poppet Check Valve

Copper Tube Flange

Single Poppet Check Valve

Meter Threads

(16)

More than a brand. We’re a family.

aymcdonald.com 1-800-292-2737 [email protected]

A.Y. McDonald Mfg. Co. is a leading manufacturer of Waterworks Brass, Plumbing Valves,

Pumps and Water Systems, and High Pressure Gas Valves and Meter Bars. The Company has

distinguished itself with a proud tradition of quality and reliability since its founding in 1856.

The mission of A.Y. McDonald Mfg. Co., in the words of our founder, is “to make good products

and sell them honestly.” We, the stockholders and employees, accomplish this by extending

the McDonald family culture through excellent customer service and by focusing on our

customers’ needs.

11/12

WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA (effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product in the installation or repair

References

Related documents

If you would like your water meter off during business hours to do repairs or to install a master supply valve please call the District office and our staff will do a meter

In practice, using a rectangular 5 point long p sequence, every y filtered point is obtained by re-calculation as the mean value of 5 points: a convolution of

The writer also uses Baker’s theory of subtitling strategies, which, according to her book In Other Words (1992), there are four types of them; paraphrase,

A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the T-K2.. In addition, a manual shut off valve is also

strainer Shut-off valve Strainer Brine return line Brine supply line Location of expansion tank, mano- meter and safety valve (1.5 bar) at pressurised brine circuit when the

Static Head Dirt Pocket Inlet Outlet Shut-Off Valve Dirt Pocket Drain Plug Outlet Valve Supply Inlet Valve Y Strainer Cover Bolts Thermostatic Vent Pipe to Gravity Return Line

 Acción de Reset permite seleccionar una de las salidas del sistema para que en caso de resetear la zona de detectores a través de la pantalla de la central, esta salida conmute

If the existing toilet does not have a supply shut-off valve below the tank, install one before installing the new toilet... Install the supply shut-off valve with the