• No results found

Benign prostatic hyperplasia (BPH) is one of the most

N/A
N/A
Protected

Academic year: 2021

Share "Benign prostatic hyperplasia (BPH) is one of the most"

Copied!
5
0
0

Loading.... (view fulltext now)

Full text

(1)

Tract Procedures

Electrocoagulation Accounts for a Significant Portion of Discrepancy Between Preoperative Ultrasonography

Prostate Size Estimation and Resected Tissue Weight

Mohammad-Hatef Khorrami, MD,1Farshad Gholipour, MD,1Mahtab Zargham, MD,1 Mehrdad Mohammadi Sichani, MD,1Mohammad-Hossein Izadpanahi, MD,1

Farshid Alizadeh, MD,1and Farbod Khorrami, BS2

Abstract

Background and Objectives: Transurethral resection of the prostate (TURP) is considered to be the gold standard surgical procedure for medium-sized prostates. However, there is a drastic difference between the weight of resected tissue reported by the pathologist and the sonographic estimate of prostate weight before the operation. The present study investigates the role of electrocoagulation in tissue loss during monopolar (M-) and bipolar (B-) TURP.

Methods: In this experimental in vitro study, 33 prostate glands removed from patients by open suprapubic prostatectomy were roughly divided in half and the weight of each half was recorded precisely. One half of the specimen was resected using a monopolar resectoscope and the other half was resected by bipolar resectoscope in an out-of-body simulated condition. The weight of obtained chips was measured and the amount of lost tissue was calculated. Data from prostates with final pathologic diagnosis of benign prostatic hyperplasia were included in the analysis. The mean difference of prostate weight before and after out-of-body resection and also the proportion of tissue loss between M-TURP and B-TURP were compared using t-test.

Results: Data from 62 prostate halves were included in the final analysis. The mean weight of samples after M-TURP was considerably lower than before resection (38.0– 6.9 and 48.7 – 9.0, respectively, p < 0.001).

Similarly, the mean weight of prostate samples after B-TURP was lower than the weight before resection (36.2– 7.3 and 48.4 – 9.1, respectively, p < 0.001). However, the ratio of tissue loss in B-TURP (25.3% – 2.5%) was significantly higher than in M-TURP (21.3%– 3.7%) ( p < 0.001).

Conclusion: Prostate resection using electrocoagulation leads to a significant prostate tissue loss due to heat effect. Furthermore, tissue loss in B-TURP is slightly more than M-TURP.

Keywords:benign prostatic hyperplasia, prostatectomy, prostate transurethral resection, pathology, measurement

Introduction

Benign prostatic hyperplasia(BPH) is one of the most common urologic diseases. Despite numerous proce- dures having been developed, transurethral resection of the prostate (TURP) is still the most practiced surgical method used for BPH treatment.1One of the relative contraindica- tions of performing TURP is large prostatic size. Therefore, choosing the best surgical approach for treatment is depen- dent on prostate size, with the European Association of Ur- ology and American Urological Association guidelines recommending TURP for medium-sized prostate glands (i.e.,

30–80 mL).2,3Assessment of prostate size before operation is usually done using transabdominal ultrasonography due to its availability and low cost. However, transrectal ultrasonog- raphy and magnetic resonance imaging (MRI) are more precise in estimating prostate size.4,5

In daily practice, the weight of resected tissue reported by the pathologist is often lower than the preoperative sono- graphic estimate of total prostatic volume. The most impor- tant explanation for this difference is reporting the total sonographic volume of prostate instead of volume of transi- tional and periureteral zones of prostate, which are resected in a complete TURP. In previous studies, the final amount of

1Department of Urology, Isfahan Research Center for Kidney Transplantation, Al-Zahra Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.

2Department of Neuroscience, University of Toronto, Toronto, Canada.

ª Mary Ann Liebert, Inc.

Pp. 671–675

DOI: 10.1089/end.2020.0037

671

Downloaded by 134.122.89.123 from www.liebertpub.com at 11/28/21. For personal use only.

(2)

resected tissue was even smaller than the transitional zone volume (TZV) estimated by ultrasonography and researchers repeatedly associate this finding with an incomplete resec- tion.6–8However, it is possible that there are other reasons behind this. We hypothesized that part of the prostate tissue is lost due to the heat produced by resection with electro- coagulation. In addition, it is worth noting that the amount of heat applied to the tissue, resection method, and homeostatic maneuvers are different between bipolar TURP (B-TURP) and monopolar TURP (M-TURP), which may lead to varying amounts of tissue loss between these methods. Previous studies that compared the two approaches have reported a lower resected tissue weight to preoperative prostate size ratio in B-TURP, although no statistical test was performed in any.9–12Considering that no previous study has explored the precise quantity of tissue loss, we conducted the current in vitro study to measure and compare the amount of tissue loss in both B-TURP and M-TURP.

Patients and Methods

This experimental in vitro study was performed from January to June 2019 after being approved by the Research Ethics Board of Isfahan University of Medical Sciences.

Patients who were candidates for open prostatectomy were evaluated for eligibility. Patients with prostate-specific anti- gen (PSA) level greater than 4 ng/dL, those with prostatic nodule felt in digital rectal examination, and patients with a history of prostate biopsy in the last 3 months were ex- cluded. Transabdominal ultrasonography was performed by an experienced radiologist. Length, width, and height of the prostate were measured using a 3.5 MHz transducer, and prostate volume was calculated using the formula for the volume of a prolate ellipsoid (width· length · height · p/6).13 Since the specific gravity of prostate tissue is 1.06 g/mL, the estimated volume is almost representative of the prostate weight.14

Urinary tract infection was treated before the operation and the decision for performing open surgery or TURP was made based on the prostate size and cystourethroscopy. Patients had a minimum prostate size of 80 mL. After changing the patient’s position to supine, a lower midline incision was made and suprapubic transvesical prostatectomy was per- formed. After prostate enucleation, the extracted tissue was cut roughly in half by an assisting surgeon. First, the weight of each half was determined by a precise scale (Metro

Electronic, India) by two decimal points. Then, one half using a monopolar resectoscope and the other half using a bipolar resectoscope underwent resection in an out-of-body simu- lated condition by another surgeon solely tasked with the resection of samples. All procedures were performed using the KLS Martin ME 402 maXimum radiofrequency gen- erator, compatible resectoscopes, and disposables (Karl Storz Endoscope, Tuttlingen, Germany). The cutting power for M-TURP and B-TURP was 90 and 80 W, respectively.

Coagulation was not performed.

To simulate M-TURP, a prostate half was placed in a stainless-steel kidney bowl filled with 300 mL of glycine. The kidney bowl was placed on a cautery plate to create a closed electrical circuit. With the prostate tissue touching the inner wall of the bowl, monopolar resection was performed in the liquid resembling real TURP conditions (Fig. 1). The re- sulting chips were sifted and after allowing the liquid on the samples to drain passively for 1 minute, their weight was measured using the same scale. To simulate B-TURP, the other prostate half was placed in an insulated container filled with 300 mL of physiologic saline. Resection was performed using the same method as monopolar resection, with the only exception being the prostate not touching the inner wall of the container. Both monopolar and bipolar resections were per- formed by the same surgeon with an appropriate level of experience with both systems. It took about 5 minutes to resect each prostate lobe by either M- or B-TURP system.

The obtained chips were measured and the weight was documented. The chips were sent for pathologic examination and data from prostates diagnosed with BPH entered the final analysis. Specimen weight reported by the pathologist was also recorded. Data were entered in IBM SPSS Statistics 20 software. T-test for independent samples was used to com- pare the prostate tissue weight before and after resection (primary outcome) and also to compare the rate of tissue loss between M-TURP and B-TURP (secondary outcome). Level of significance was set at 0.05.

Results

Enucleated prostates from 31 patients with a mean age of 69.3– 7.1 years and mean PSA levels of 3.2 – 1.8 ng/dL were included in the analysis. The mean preoperative sonographic volume of prostates was 112.8– 25.3 mL. Based on the pathologic examination, one case of xanthogranulomatous

FIG. 1. Out-of-body prostate resec- tion by monopolar resectoscope.

(A)The technique of resection and (B)prostate chips.

Downloaded by 134.122.89.123 from www.liebertpub.com at 11/28/21. For personal use only.

(3)

prostatitis and one case of prostate cancer with more than 5%

of chips involved were excluded from the final analysis.

In the monopolar group, the mean weight of the tissue before resection was 48.7– 9.0 g, which was reduced to 38.0– 6.9 g after resection ( p < 0.001). Similarly, tissue weight was decreased significantly after bipolar resection (48.4– 9.1 vs 36.2 – 7.3, p < 0.001) (Fig. 2). The relative amount of reduced tissue weight in monopolar and bipolar resection was 21.3%– 3.7% and 25.3% – 2.5%, respectively ( p< 0.001) (Table 1). The sum of the average weight of re- sected tissue by both resectoscopes was 74.2– 14.2 g, which was different from the pathology report of the sample weight after fixation in formalin (67.5– 12.4 g, p < 0.001).

Discussion

Our results indicated that a significant amount of tissue is burned and lost during both monopolar and bipolar systems, but higher in B-TURP (*25%) than M-TURP (*21%). To our knowledge, our study is the first to experimentally de- termine the amount of tissue loss due to TURP in an in vitro model. Studies on TURP outcomes performed usually on medium-sized prostates showed that the resected tissue weight is 28%–78% of preoperative sonographic total vol-

ume of prostate.9–12,15–17So far, the major reasons behind this have mainly been presented as the resection of only transitional and periureteral prostate zones in a complete TURP and simply an incomplete resection. Another reason offered by Lukacs and colleagues was a 13.3% loss of tissue after fixation with formaldehyde, which is concordant with 10% reported in our study.18 The findings of this article provide another reason by explaining the effect of heat gen- erated from electrocoagulation on tissue loss.

Our results demonstrated that B-TURP caused more tissue loss than M-TURP. In monopolar circuit, the return electrode is placed in a region of the body far from the active electrode.

Therefore, the current travels a notable distance to reach the end of the circuit.19In contrast, in the bipolar method, the return and active electrodes are positioned close to each other. Thus, the current only travels a short distance between the electrodes.20 Bipolar systems need lower energy and voltage to complete the circuit owing to less tissue and thus lower resistance. Usually in a monopolar system, the urolo- gist quickly performs the resection and leaves the homeo- stasis until the end of operation. In contrast, during B-TURP, the low voltage leads to some levels of homeostasis. Home- ostasis is not controlled by the depth of current penetration in M-TURP, but it is dependent on the speed with which the loop passes through the tissue during bipolar resection and it is recommended to lower the speed of resection to benefit from the simultaneous homeostasis during the B-TURP.

The bipolar system fosters the possibility of performing TURP in physiologic saline. Prevention of transurethral resec- tion (TUR) syndrome during B-TURP makes it possible to be performed with care and at a slow pace. However, previous studies have not described longer operation time for B-TURP, which can be explained by the time attained from better ho- meostasis during this procedure.5,17,21–24 The increased ho- meostasis during B-TURP leads to higher tissue burning and evaporation compared with M-TURP and explains our results of more tissue loss using the bipolar system. In separate studies performed by Huang and colleagues on pathologic specimens of TURP, the authors showed that B-TURP has a mean coagula- tion depth bigger than the maximum microvessel diameter, and B-TURP has better hemostatic capability than M-TURP.15,25 Although no study has directly compared the amount of tissue loss between M-TURP and B-TURP, many have researched the consequences of these systems and reported the volume of prostate before and weight of resected tissue after the surgery separately. The weight to volume ratio calculated from these studies was 2%–10% more in M-TURP than B-TURP, which is consistent with the findings of the present study.9–12

The most prominent limitation of this study was the out-of- body resection. Despite our efforts to reproduce a real TURP during the resection, there are still differences: often, in an actual TURP, first chips are larger than the last ones. Al- though we attempted to reduce this difference by replicating an actual resection technique, in out-of-body resection, there is no need for electrocoagulation, while during TURP occa- sionally there is a need for coagulation before finishing resection, which can theoretically affect the amount of evaporation; Out-of-body resection of last chips in mono- polar system is difficult owing to the need for direct contact of tissue with the container wall. Although the last chips form a small portion of the total volume and the confounding effect will be negligible; and finally, the current study involved FIG. 2. Box-plot showing weight before and after resec-

tion of prostate by different resectoscopes.

Table 1. Weight Assessment Values M-TURP

(n= 31)

B-TURP (n= 31) p Before resection (g):

mean– SD

48.7– 9.0 48.4– 9.1 0.910 After resection (g):

mean– SD 38.0– 6.9 36.2– 7.3 0.322 Percentage decrease (%) 21.3– 3.7 25.3– 2.5 <0.001 SD= standard deviation; TURP = transurethral resection of the prostate; B-TURP= bipolar TURP; M-TURP = monopolar TURP.

Downloaded by 134.122.89.123 from www.liebertpub.com at 11/28/21. For personal use only.

(4)

larger prostate specimens from patients undergoing open prostatectomy which have epithelial nodule predominance unlike smaller prostates undergoing TURP with predomi- nance of fibromuscular stroma.26,27This possible histopath- ologic difference may slightly influence the tissue resistance and electrocoagulation properties.

Despite all of the aforementioned limitations in out-of- body resection of the prostate, they seem to have little to no effect on the final outcomes of the study. Furthermore, the benefit of out-of-body resection of prostate for assessment of tissue loss outweighs the limitations. M-TURP may not allow full resection due to the risk of developing TUR syndrome, while B-TURP provides the opportunity to fully resect the prostate with near perfection. On the contrary, a direct and trustable measurement of tissue weight is unlikely in clinical studies, even with the aid of MRI to determine the TZV, which will be resected during the procedure. Therefore, a clinical study cannot effectively measure and compare the amount of tissue loss without error, while this study with an in vitro design succeeded in tackling this issue.

Several clinical studies have discussed the effect of a complete prostate resection on some clinical outcomes by comparing the sonographic TZV before the operation with the weight of resected tissue.6–8Acknowledging the fact that a noteworthy part of the tissue is lost during resection allows the urologist to be cautious in associating the degree of re- section completeness with clinical outcomes and equips it with better foresight in research design or data analysis.

In summary, the four major reasons for the weight of resected tissue by TURP being lower than the estimated sonographic volume are (1) resection being limited to transitional zone and periurethral tissue during the operation, (2) performing an in- complete TURP, (3) loss of tissue due to the heat generated as a result of electrocoagulation, and (4) tissue reduction after fix- ation with formaldehyde. Other possible reasons for the issue are tissue blood loss throughout the resection and loss of small chips during sample collection. Even if the precise weight of prostate after operation is not of high importance yet, it is well established that it should be recorded as it may be valuable in future research and critical in precise documentation.

Conclusion

Prostate resection using a resectoscope leads to a signifi- cant loss of tissue due to tissue evaporation caused by heat resulted from electrocoagulation. This article provides an- other reason for the drastic difference between the sono- graphic size of the prostate before surgery and the final weight reported by the pathologist. In addition, the loss in M-TURP and B-TURP is unequal, a difference that can be explained by their different mechanisms of action.

Author Disclosure Statement

No competing financial interests exist.

Funding Information

No funding was received for this article.

References

1. de la Rosette JJ. Tailoring treatment in benign prostatic hyperplasia management. Curr Opin Urol 2009;19:1–2.

2. Gravas S, Cornu J, Gacce M, et al. Management of non- neurogenic male lower urinary tract symptoms (LUTS) incl. benign prostatic obstruction (PBO), in EAU Guide- lines. Edn. presented at the EAU Annual Congress Barce- lona 2019. ISBN 978-94-92671-04-2.

3. Foster HE, Dahm P, Kohler TS, et al. Surgical management of lower urinary tract symptoms attributed to benign prostatic hyperplasia: AUA guideline amendment 2019.

J Urol 2019;202:592–598.

4. Styles R, Neal D, Powell P. Reproducibility of measure- ment of prostatic volume by ultrasound. Eur Urol 1988;14:

266–269.

5. Paterson NR, Lavalle´e LT, Nguyen LN, et al. Prostate volume estimations using magnetic resonance imaging and transrectal ultrasound compared to radical prostatectomy specimens. Can Urol Assoc J 2016;10:264.

6. Park HK, Paick SH, Lho YS, Jun KK, Kim HG. Effect of the ratio of resected tissue in comparison with the prostate tran- sitional zone volume on voiding function improvement after transurethral resection of prostate. Urology 2012;79:202–206.

7. Bergdahl S, Aus G, Lodding P, Norle´n L, Hugosson J. Trans- rectal ultrasound with separate measurement of the transition zone volume predicts the short-term outcome after transure- thral resection of the prostate. Urology 1999;53:926–930.

8. Aus G, Bergdahl S, Hugosson I, Norlen L. Volume deter- minations of the whole prostate and of adenomas by transrectal ultrasound in patients with clinically benign prostatic hyperplasia: Correlation of resected weight, blood loss and duration of operation. Br J Urol 1994;73:659–663.

9. Yoon C-J, Kim J-Y, Moon K-H, Jung H-C, Park T-C.

Transurethral resection of the prostate with a bipolar tissue management system compared to conventional monopolar resectoscope: One-year outcome. Yonsei Med J 2006;47:

715–720.

10. Seckiner I, Yesilli C, Akduman B, Altan K, Mungan NA.

A prospective randomized study for comparing bipolar plasmakinetic resection of the prostate with standard TURP. Urol Int 2006;76:139–143.

11. Engeler DS, Schwab C, Neyer M, Gru¨n T, Reissigl A, Schmid H-P. Bipolar versus monopolar TURP: A pro- spective controlled study at two urology centers. Prostate Cancer Prostatic Dis 2010;13:285.

12. Ho HS, Yip SK, Lim KB, Fook S, Foo KT, Cheng CW.

A prospective randomized study comparing monopolar and bipolar transurethral resection of prostate using transure- thral resection in saline (TURIS) system. Eur Urol 2007;52:

517–524.

13. Greene D, Egawa S, Hellerstein D, Scardino P. Sono- graphic measurements of transition zone of prostate in men with and without benign prostatc hyperplasia. Urol- ogy 1990;36:293–299.

14. Varma M, Morgan JM. The weight of the prostate gland is an excellent surrogate for gland volume. Histopathology 2010;57:55–58.

15. Huang X, Wang L, Wang X-H, Shi H-B, Zhang X-J, Yu Z-Y. Bipolar transurethral resection of the prostate cau- ses deeper coagulation depth and less bleeding than monopolar transurethral prostatectomy. Urology 2012;

80:1116–1120.

16. Giulianelli R, Albanesi L, Attisani F, et al. Comparative randomized study on the efficaciousness of endoscopic bi- polar prostate resection versus monopolar resection tech- nique. 3 year follow-up. Arch Ital Urol Androl 2013;85:

86–91.

Downloaded by 134.122.89.123 from www.liebertpub.com at 11/28/21. For personal use only.

(5)

17. De Sio M, Autorino R, Quarto G, et al. Gyrus bipolar versus standard monopolar transurethral resection of the prostate: A randomized prospective trial. Urology 2006;67:69–72.

18. Lukacs S, Vale J, Mazaris E. Difference between actual vs.

pathology prostate weight in TURP and radical robotic- assisted prostatectomy specimen. Int Braz J Urol 2014;40:

823–827.

19. Issa MM. Technological advances in transurethral resection of the prostate: Bipolar versus monopolar TURP. J Endourol 2008;22:1587–1596.

20. Miki M, Loritani N. TUR in Saline: TURis. Tokyo, Japan:

Publisher Olympus Corporation, 2004.

21. Akc¸ayo¨z M, Kaygisiz O, Akdemir O¨ , Aki FT, Adsan O¨, Cxetinkaya M. Comparison of transurethral resection and plasmakinetic transurethral resection applications with re- gard to fluid absorption amounts in benign prostate hy- perplasia. Urol Int 2006;77:143–147.

22. Tefekli A, Muslumanoglu AY, Baykal M, Binbay M, Tas A, Altunrende F. A hybrid technique using bipolar energy in transurethral prostate surgery: A prospective, random- ized comparison. J Urol 2005;174:1339–1343.

23. Wu W, Wang X, Wang H, et al. Therapeutic efficacy of bipolar plasmakinetic technique compared with transure- thral resection on benign prostate hyperplasia. Zhonghua Yi Xue Za Zhi 2005;85:3365–3367.

24. Yang S, Lin W-C, Chang H-K, et al. Gyrus plasmasect: Is it better than monopolar transurethral resection of prostate?

Urol Int 2004;73:258–261.

25. Huang X, Wang X-h, Wang H-p, Qu L-j. Comparison of the microvessel diameter of hyperplastic prostate and the coagulation depth achieved with mono-and bipolar trans-

urethral resection of the prostate A pilot study on hemo- static capability. Scand J Urol Nephrol 2008;42:265–268.

26. Shapiro E, Becich MJ, Hartanto V, Lepor H. The relative proportion of stromal and epithelial hyperplasia is related to the development of symptomatic benign prostate hyper- plasia. J Urol 1992;147:1293–1297.

27. Franks L. Gross and microscopic anatomy. In: Benign Prostatic Hyperplasia NIAMDD Workshop Proceedings, DHEV Publication, 1976, pp 63–89.

Address correspondence to:

Farshad Gholipour, MD Department of Urology Isfahan University of Medical Sciences Soffeh Boulevard Isfahan 8174675731 Iran E-mail: [email protected]

Abbreviations Used BPH¼ benign prostatic hyperplasia MRI¼ magnetic resonance imaging PSA¼ prostate-specific antigen

TURP¼ transurethral resection of prostate B-TURP¼ bipolar TURP

M-TURP¼ monopolar TURP TUR¼ transurethral resection TZV¼ transitional zone volume

Downloaded by 134.122.89.123 from www.liebertpub.com at 11/28/21. For personal use only.

References

Related documents

Under this cover, the No Claim Bonus will not be impacted if repair rather than replacement is opted for damage to glass, fi bre, plastic or rubber parts on account of an accident

Other specializations include: FCC and State (PUC/Secy of State) regulatory, transactional, tax, litigation and advocacy; communications taxes &amp; VoIP taxation issues;

The hypothesis test was performed using the SPSS (Statistical Package for Social Science) for Windows version 22.0 as shown in Table 3. The following can be known from the

When addiction is likely, the next SBIRT steps are to engage the patient in a comprehensive evaluation by a substance use specialist, ensure assessment for co-occurring mental

Study factors included timing of diagnosis, coexistent congenital anomalies, preterm birth (&lt;37 weeks’ gestation), age at primary surgery, public or private health

WHAT THIS STUDY ADDS: DRIFT, which lowers pressure and distortion and washes out free iron and cytokines, reduced death or severe disability, especially severe cognitive disability at

comparable between the 2005 and 2008 surveys, because different an- swer options were available to respon- dents; for example, the 2005 survey response option for ACIP recommen-

The education of the pediatrician is specifically designed to provide comprehensive training for the health care of infants, children, adolescents, and young adults, as well as