9 August 2021 V6.06.01.332

New Supported Models

cMT2078X, cMT2158X

New Features

1. [Find Overlapping Objects] Added tool to help find overlapping objects in a project.

2. [Convert to Combo Button] Added tool to help convert multiple objects into a single Combo Button.

3. [Copy Formatting] Added tool to copy text formatting from one object and apply it to another one.

4. [Label] Added support for vertical / horizontal alignment of text relative to the object.

Added Vertical Alignment button in the ribbon menu. (The multiline align setting has been renamed as such.)

5. [Window Copy] When performing window copy, underlay windows will be copied along with the target window.

cMT / cMT X Series

Features additions listed in this section are available for cMT / cMT X series models.

1. [OPC UA Server] Added reverse high/low byte setting for string tags.

2. [Database Server] Added support for connection with Azure SQL Database.

3. [Data Sampling] Added an option in Customized File Handling. When file creation mode is Trigger mode, this option can be selected so that, following HMI reboot, data will be written to a new file only after the designated register has been triggered.

4. [Numeric] Allowed Float and Double data types to use customized display format.

5. [PLC Web Browser] Added support for Status and Error Code control addresses.

6. [Alarm Display / Event Display] Added support for displaying column headers.

7. [Numeric] Added support for dynamic low/high limit settings using non-consecutive addresses.

8. [MQTT] In value-trigger-based mode, added [Included in all messages sent] option in MQTT Publisher’s Address settings. Added [Required for all incoming messages] option in MQTT Subscriber’s Address settings.

9. [System Registers] Added WiFi hotspot related system registers.

10. [Control Token] Added support for manual control token acquisition. The control token can be acquired or unacquired by using an Action Trigger object.

11. [Project] Added support for project checksum to ensure project integrity. It can be found during compilation, uploading / downloading of project, or in the corresponding system registers.

(2)

12. [Others] Added support for Cyrillic keyboard layout.

cMT / cMT X Series – compatibility

All features listed in this section are added on cMT / cMT X series for compatibility with the behavior of legacy models.

1. [Backup] [Screen Hardcopy] Added support for output to FTP.

2. [Trend Display] [History Data Display] [Event Display] Added support for history control addresses.

3. [Trend Display] Added support for dynamic X-axis time range control.

4. [Event Log] Provided an option to record dynamic String ID when using a string table.

Drivers

1. [LEADSHINE mPLC2 Modbus RTU, TCP/IP] Added new driver.

2. [YOKOGAWA FA-M3] Added address types: TP, TU, CU.

3. [YASKAWA MP2300Siec (Ethernet)] Added Electronic Key option.

4. [CAN Bus CANopen Slave] Added NMT START Command control address.

5. [Siemens S7-300 MPI] [Siemens S7-300/ET200S (Ethernet)] Added address types: T, C.

6. [Beckhoff TwinCAT PLC – Free Tag Names (Ethernet)] Added support for import (tpy) and use of tags in their hierarchical form.

7. [KEYENCE KV-8000 (Symbolic)(Ethernet)] Added support for the use of Function Block addresses.

8. [ODVA EtherNet/IP (Explicit Messaging)] Added support for binary access to array addresses.

5 May 2021 V6.05.02.434

New Features

6. [Macro] Added built in macro functions: CEIL, FLOOR, ROUND, INPORT4.

7. [Macro] Added an (optional) parameter for DATE2ASCII function; the input argument is a separator that is inserted between the year, month, day (YYYY MM DD) strings.

8. Added dynamic file name support for extended memory.

iP Series

1. Added support for the following features Categorized by type.

• Buttons / Lamps i. Combo Button

ii. Word Lamp -Bit Combination

• Numeric Display

i. Customized Display Format ii. Macro Subroutine Scaling

(3)

• Charts

i. Pie Chart

ii. Dynamic Drawing iii. Dynamic Scale iv. Table

• Data Sampling

i. Customized File Name ii. Circular Trend Display

• Event Log

i. Dynamic Condition ii. Statistics

• Browser / Viewer i. File Browser ii. Picture View

• Recipe Management i. Recipe Database ii. Recipe View

iii. Recipe Import / Export

• System Safety

i. Enhanced Security Mode ii. Operation Log

• Others

i. Flow Block

ii. Daylight Saving Time

cMT / cMT X Series

Feature additions listed in this section are available for cMT / cMT X series models that support the listed objects.

1. [Alarm Bar][Alarm Display][Event Display][Event Bar Chart]

Added “Option Button Visibility”

setting. It provides and option to show / hide the Option Button or to control its visibility dynamically by a register. Note: Checking the Option Button opens the Option dialog.

2. [File Transfer]

Added support for dynamic adjustments of the FTP server connection parameters.Note: File Transfer is one of the actions that can be triggered by Action Trigger /Combo Button.

3. [File Transfer]

Added the option [Delete the source file after successful transfer].

4. [Meter] Added support for visibility setting of the pin point.

5. [System Parameters] Added “Display time for min. press time” settings. Applying to buttons whose “min.

press time” is non-zero, it allows a countdown timer to be shown when buttons are pressed.

(4)

6. [System Parameters] Added “Play next sound after stopping previous” option.

7. [SQL Query] Increased the SQL query command limit to 2000 characters.

8. [Recipe View] Added support for content filter.

9. [Enhanced Security Mode] Added support for SSL encryption for LDAP mode.

10. [System Registers] Added the following system registers related to mounting of external USB devices.

LW-12492 Last detected USB partition ID LW-12496 Last detected USB partition size (GB) LW-12498 Set the partition ID to be used as USB1 LW-12502 Set the partition ID to be used as USB2

The registers may be, for example used to force an external USB to mount to a specific location, dist1 or disk2.

All features listed in this section are added on cMT/ cMT X series for compatibility with the behavior of legacy models.

1. [Remote HMI] Increased the maximum allowable to 64.

2. [Option List] Added color setting for the selected row.

3. [Picture View] Added First and Last buttons in the toolbar.

4. [XY Plot], [Trend Display], [Alarm Display], [Event Display], [History Data Display] Added picture settings.

5. [Media Player] Added [No control] mode.

6. [Video In] Added support for single image capture.

7. [Video In] Added [Use pause control] for the control address, i.e., pause command is available.

8. [Alarm Display] [Event Display] Added support for [Scrolling control address] designation.

9. [Alarm Display] [Event Display] Added support for event acknowledgement by double-click 10. [Alarm Display] [Event Display] Added support for event sorting by occurrence count (real-time

mode)

11. [System Parameters] Added the [Enable time synchronization with external device when HMI starts] option.

(5)

12. [Recipe View] Added support for automatic scrolling to the view that shows the row specified by the value of RECIPE Selection.

13. [Recipe View] Added color setting for the selected row, for Default style.

14. [Timer (per-page)] Added support for this object to use timers in individual windows.

15. [Scheduler] Added support for sound.

16. [Shape] Added support for legacy pattern types (dot and line pattern types)

17. [System Register] Added support for the following system registers related to data logs and event logs.

• LB-9035: HMI free space insufficiency alarm

• LB-9036: SD card free space insufficiency alarm

• LB-9037: USB disk 1 free space insufficiency alarm

• LB-9026: delete all data sampling files on HMI memory

• LB-11950: delete all data sampling files on SD card

• LB-11953: delete all data sampling files on USB disk 1

• LB-11956: delete all data sampling files on USB disk 2

• LB-9034: save event/data sampling to HMI, USB disk, SD card

• LB-9023: delete all event log files on HMI memory

• LB-11941: delete all event log files on SD card

• LB-11944: delete all event log files on USB disk 1

• LB-11947: delete all event log files on USB disk 2

• LB-9034: save event/data sampling to HMI, USB disk, SD card

Corrections

1. Fixed the issue where EasyBuilder Pro allows cMT-FHDX models to set PLC Web Browser related features. At this moment, PLC Web Browser is not supported on cMT-FHDX.

2. Fixed the issue where Unicode related macro functions (UnicodeCat, Unicode Excluding, UnicodeLength, Utf82Unicode) cannot be properly executed on HMI.

3. Fixed the issue where macro may stop abnormally after performing the described operations: Use GetData() to read data from a recipe database and then use SetData() to write the data to Tag PLC addresses.

4. Fixed the issue where MQTT topic subscriber under manual operation mode can no longer handle any data once it has processed a message that does not correctly contain all keys.

5. Fixed the issue where USB related features do not work properly on cMT-SVR

6. Fixed the issue where Scheduler does not perform actions at the correct time the first time after clocks change.

7. Fixed the issue where cMT Viewer cannot display Event Display contents when it connects to a program that is not created using v6.05.02.

8. Fixed the issue where the label’s option, ON=OFF (use state 0), bit lamp /toggle switch in ineffective.

9. (cMT2078X/cMT3072X/cMT3072XH) Fixed the issue where event log does not show on the web page.

10. (cMT Series HMI, cMT Viewer) Fixed an issue where the screen display may come to an abnormal halt when an event with the following condition has been triggered.

Condition: The option [Enable continuous beep until acknowledged or recovered] for

sound is enabled.

(6)

11.

cMT X Series

1. Added support for USB2.

IIoT Gateway Series

1. Added support for SQL Query.

Drivers

1. [KONNEX KNXnet/IP] Added [Support multiple connections] option under Tunneling mode.

2. [Schneider MODBUS RTU] Added new addresses %I, %Q, %IW, %QW, %SW, %KW,

%IWS, %X, %TM_V, %TM_P, %TM_Q.

3. [XINJE MTX XD/XL Series] Added new driver 4. [MODBUS Server] Added new driver.

5. [MODBUS Server] Fixed an issue that results in incorrect response to commands with function code 0x06 (write single holding register).

6. Added the driver Mitsubishi M80 (Ethernet).

7. CODESYS V3 (Ethernet) added optimum communication protocols.

8. Added the driver CHONG HUI Controlwell MD Series.

cMT Diagnoser

1. Added support for monitoring of tag-based addresses.

2. Added support for monitoring of data in Decimal, Hexadecimal, and Binary formats.

cMT Viewer

1. Added support for connections using non-default ports. The way to use non-default ports is by entering the offset along with IP address; for example, if offset is 10000, enter 192.168.1.1:10000 in the IP field. The allowable range of offset is 0~19999. All ports used will have an offset accordingly.

Easy Converter

1. Added support for integrity check of Operation Log by Command Line Interface.

2. Added support for conversion of data logs and event logs in MS SQL / MySQL database into CSV files (using Command Line Interface).

7 Jan 2021 V6.05.01.565

New Features

9. [PDF Reader] Added support for designating an address to dynamically change zoom ratio.

10. Added S7-300 MPI Subnet ID Tool.

11. Added [PLC Web Browser] support for cMT3092X, cMT3152X and cMT3162X. The applicable OS version is 20201202 or later.

Corrections

12. Fixed an issue where certain windows in EasyBuilder Pro may grow too big when the

font size in Windows is set to 125%.

(7)

13. Fixed an issue where download attempt after an Event Log import from Excel file does not trigger compilation.

14. Fixed an issue where incorrect permissions were granted when a user logs in to an OPC UA server by username / password.

15. Fixed an issue where the latest file in the Data Log (with Customized File Handling enabled) is deleted after project re-download.

16. Fixed an issue where addresses used by certain objects are not reflected accordingly in the Address Grid.

Drivers

3. [KEYENCE KV-8000 (Symbolic)(Ethernet)] Added new driver.

4. [Beckhoff TwinCAT PLC – Free Tag Names] Fixed an issue where STRUCT containing certain characters cannot be imported.

5. [OMRON EtherNet/IP (NJ/NX Series)] Fixed an issue where Description are not correctly imported.

6. [OMRON EtherNet/IP (NJ/NX Series)] Fixed an issue where cMT-SVR may sometimes be disconnected from OMRON NJ.

7. [RS Automation X8 Series] Fixed an issue where address settings in a decompiled file are not correct.

8. [OPC UA Client] Fixed an issue where using many tags (> 2000) may cause the system to stop working.

9. [OPC UA Client] Fixed bit writing issues with certain OPC UA server.

10. [OPC UA Client] Added index register support for array tags.

11. [Mitsubishi M70 (Ethernet)] Fixed an issue where bit data cannot be correctly written when using a macro.

12. [Siemens S7-1200/S7-1500 (S7CommPlus, Symbolic Addressing) (Ethernet)] Added index register support for string array tags.

13. [Siemens S7-1200/S7-1500 (S7CommPlus, Symbolic Addressing) (Ethernet)] Optimized communication.

14. [CAN Bus] Fixed an issue where 64-bit data cannot be correctly read when using macro.

15. [Siemens S7-300 MPI] Optimized communication for cMT X Series models.

16. [BACnet/IP][BACnet/MSTP] Added support for UDINT data type.

15 Nov 2020 V6.05.01.441

Corrections

17. (Basic and Advanced HMIs) Fixed an issue where SYNC_TRIG_MACRO() and ASYNC_TRIG_MACRO() functions do not execute the specified macro.

18. Fixed an issue where there is unintended blank space around the address setting field for some languages of EBPro installation.

19. Fixed an issue where OPC UA HDA does not save historical data.

Drivers

17. [Beckhoff TwinCAT PLC – Free Tag Names] Fixed an issue where the system may not

operate properly when using this driver.

(8)

18. [S7-1200/1500 (S7CommPlus, Symbolic Addressing) (Ethernet)] Added support for the use of string array with customized length.

19. [OMRON EtherNet/IP (NJ/NX Series)] Fixed an issue where individual bits of DINT data cannot be accessed.

20. [Mitsubishi M70 (Ethernet)] Added new driver

5 Nov 2020 V6.05.01.391

New Features cMT Series

All features listed in this section are available exclusively for cMT series or selected models only.

1. [Set Word] Added “Write constant string” operation.

2. [System Registers] Added system register LB-12752: Disable / Enable vibration.

3. [SQL Query] Added support for customizing the length of the error message and the upper limit is 200 words.

4. [MQTT] Added support for enabling/disabling individual topic publisher /subscriber (in security tab).

5. [MQTT] Added manual processing mode for topic subscriber. In this mode, subscribed data get placed in a queue before being processed manually.

6. [MQTT] Added “Clear message buffer when disconnecting gracefully” option.

7. [Trend Display] Added “Adapt to device screen pixel density (DPI)” option for adjusting the font/button sizes according to the DPI settings.

8. [Bar Graph] Added support for dynamically changing the color of the Bar Graph.

9. [Data Transfer] Added support for filename filtering using * and ? wildcard characters.

10. [Data Sampling] Added support for setting the data format for each channel. The same settings may be used by its Trend / History Data Display charts.

11. [Recipe Database] Added dedicated recipe commands for transferring recipe data between HMI and PLC.

12. [PLC Web Browser] Feature added. Availability varies by model and OS version.

13. [Operation Log] Added support for using Backup object to generate a backup file with checksum. EasyConverter can then be used to examine data integrity.

14. [JS Object] [JS Resource] Features added. JS related features allow the use of JavaScript to expand HMI capabilities such as accessing web resources, drawing, and interactive control. JS Resource can include JavaScript libraries or other non-JavaScript files that work with JS object. Availability varies by model and OS version. V6.05.01

15. [Macro] Increased the number of macros to 500 (no. 0~499) cMT3092X

1. Added support for using USB2.

cMT3072X/XH

1. Added support for [Video Input].

2. Added support for [Media Player].

(9)

Utility Manager

1. The dialog asking for administrator privilege will not show upon launching Utility Manager. Instead, it now shows when the function that actually requires administrator privilege is used.

OPC UA

1. Added support for clearing HDA file (historical data) with system register LB-12753.

EasyConverter

1. Added support for checking data integrity of Operation Log.

2. Added support for working with very large db file.

Corrections

1. (Basic series) Fixed the issue where EasyAccess 2.0 does not work under certain circumstances.

2. In the setting page for operation log, the fields to the right of the window name will no

longer be editable.

(10)

21 Oct 2020 V6.04.02.620

New Feature

1. (Basic Series) Added support for EasyAccess 2.0.

Corrections

1. Fixed an issue where project files created using an earlier version of EasyBuilder Pro may not be successfully compiled.

2. Fixed an issue where a temporary pause may be experienced when changing window with window transition animation. This occurs only after the screen is left untouched for a long time.

3. Fixed the settings window of certain objects so that the redundant horizontal scrollbar no longer appears.

4. Fixed the problem where reading of data from BOOL array may, in rare cases, return incorrect result when using the driver [OMRON EtherNet/IP (NJ/NX Series)].

5. (Basic and Advanced series) Fixed an issue where using multiple conversion tags might lead to system instability if the project is made with EBPro version V6.04.02.597 or V6.04.02.611. Only the models listed are affected.

Drivers

1. [Schneider M340/M580] series (Symbolic Addressing) (Ethernet)]

Added driver.

2. [OMRON EtherNet/IP (NJ/NX Series)] Improved communication efficiency of BOOL array.

3. [BACnet/IP Server] Added support for setting device id (LW- 12245).

4. [Fuji SPH2000/3000 IEC mode (Ethernet)]

Added driver.

21 Sept 2020 V6.04.02.552

New Feature

EasyBuilder Pro

1. (Basic and Advanced) Added support for sorting by occurrence count for Event Display.

Corrections

EasyBuilder Pro

(11)

2. Increased the upper limit of the argument of DELAY function from 32767 to 2147483647.

3. Fixed issues relating to the object centering tool.

4. Fixed an issue where the objects cannot be correctly resized using Ctrl + ← or → key combinations.

5. (Basic and Advanced HMIs) Fixed an issue where Unicode texts are not properly displayed in ASCII object.

6. Fixed an issue where touch gestures cannot be configured properly.

7. (cMT) Fixed an issue where the displayed texts are not aligned as configured.

8. (cMT) Fixed an issue where Set Word’s [Before writing] notification setting is ineffective.

9. Added UnicodeLength macro function.

cMT Series

Fixed and issue where the popup window / indirect window / direct window may be displayed at an incorrect position.

EasyConverter

(cMT) Fixed an issue where confirmation records of event log files may be interpreted incorrectly.

Drivers

5. [FATEK FB/FBs/B1/B1z Series] Added support for using octal addresses for WX WY WM WS.

6. [LS XBM/XBC Cnet] Fixed communication issues related to RW, RW_Bit.

7. [Schneider Powerlogic Modbus TCP/IP]

Added driver.

26 Aug 2020 V6.04.02.483

Product Additions

Added support for cMT3092X, cMT3152X, cMT3162X, cMT-FHDX, cMT3072X and cMT3072XH models.

New Features

EasyBuilder Pro

1. Added support for defining file names in extended memories.

2. Adjusted address setting interface:

a. New tags can be created using the current address setting.

(12)

b. The list of available address tags (including system and user-defined tags) can be opened by clicking the address type drop-down.

3. The content of the tags / strings (of address tag library/ string table, respectively) is also displayed in the selection field instead of just its ID.

cMT Series

All features listed in this section are available exclusively for cMT series only

8. [System Parameters] Added support for setting mouse cursor size.

9. [Action Trigger] Action Trigger has two types, each with different modes for triggering action execution:

Action Trigger (Global): Effective in all windows, and

actions are triggered with [Idle timeout] or [Value changed] modes.

Action Trigger (per-page): Effective only in the window

where the object is placed, and actions are triggered with [Window on/off] or [Backlight on/off] modes

10. [OPC UA Server] Added support for OPC UA Historical Data Access (HDA).

This feature is configured at each node.

(13)

11.

[MQTT]

Reclassified Connect State in System Topic into Birth Topic, Close Topic, and Last Will, the content of which can now be configured individually

12.

[MQTT]

Added support for previewing message content in user- defined JSON format.

13. [MQTT] Optimized multi-topic communication efficiency 14. [Text] [Picture] Added support for Flip and Rotate operations. The

shortcuts are found in the Ribbon toolbar.

15. [Moving Shape] Added support for rotation control by a register 16. [MQTT] Added support for multi-line data entry.

Corrections

1. (cMT Gateway) Added support for Action Trigger object. (Supports only the functions suitable for Gateway.)

2. (cMT Series) Added settings: [Embedded in parent window] or [Popup window] for Direct / Indirect Window. The setting determines whether the window is displayed on the top layer when it pops up.

3. (cMT-SVR) Fixed an issue where the screen saver does not work.

4. (Basic and Advanced HMIs) Fixed an issue where objects in momentary mode do not work properly.

5. (Basic and Advanced HMIs) Fixed an issue where the channels are not displayed as configured in Trend Display object.

6. Fixed an issue where the Video Input object may be displayed at an incorrect position if its dynamic RTSP URL is enabled.

7. Fixed an issue where index registers do not work properly for certain objects.

(14)

8. Fixed an issue where opening, editing, and decompiling certain project files may result in EasyBuilder Pro crash.

Driver Updates

17. [Panasonic FP (Ethernet)] Added support for importing tags in a CSV file 18. [Panasonic FP/KW] Added DT_String address type.

19. [Delta AS300 MODBUS RTU/ASCII] Optimized communication efficiency by adopting multi-read mechanism.

20. [Hengtong HT_EMS] Added addresses: Dynamic Station Number and High Voltage Side Meter.

21. [Siemens S7-1200/S7-1500 (Absolute Addressing) (Ethernet)]

Added support for 64bit addresses.

22. [CODESYS V3 (Ethernet)] [OMRON EtherNet/IP (NJ/NX Series)]

[Schneider SoMachine M Series (Ethernet)] [OPC UA Client]

Added two data mapping options for importing tags that contain IEC-61131 STRING data type.

23. [CoDeSys V2 Symbolic Addressing (Ethernet)]

24. [ProConOS]

25. [Beckhoff TwinCAT PLC (Ethernet) Free Tag Names]

26. [Bosch Rexroth SIS (Symbolic Addressing)]

27. [IEC61850 MMS Client]

28. [Bosch Rexroth IndraControl – Free Tag Names (Ethernet)]

Fixed an issue where index registers do not work properly when being used by certain address types.

29. [Panasonic FP (Ethernet)] Fixed communication issues with devices of station number > 10.

30. [OMRON EtherNet/IP (NJ/NX Series)] Fixed an issue where BOOL array may not be correctly read.

31. [Inovance H5U MODBUS TCP/IP] Added new driver.

27 May 2020 V6.04.01.473

Product Additions

Added support for cMT3092X, cMT3152X, and cMT3162X products Corrections

1. Fixed an issue where addresses used by bool arrays in macro and Option List are not shown in the address grid.

2. Fixed an issue where extended memory related error messages may appear during compilation when an earlier version project is opened using new version software.

3. Fixed an issue where the position of the flow block is incorrect when an earlier version project is opened using new version software.

4. Fixed an issue where macros used in Numeric Input, Action Trigger, and Touch Gesture

cannot be found by Find / Replace.

(15)

5. Increased maximum allowable length to 256 characters for Connection String of MQTT Azure IoT.

6. Removed string table related settings for Basic HMI Series since they are not supported on Basic Series.

7. [Multi-State Switch] Fixed an issue where the Apply button in object’s properties window does not work properly.

8. Declared variables in macro will retain the result from last execution.

9. [Basic HMI] Fixed an issue where dates on Trend Display’s time axis are not displayed.

10. Fixed an issue where the screensaver appears only once on iOS version cMT Viewer.

11. [Database Server] Fixed an issue where [Use domain name] setting cannot be remembered.

Driver Updates

32. [Rockwell Micro850] Fixed an issue where using a non-zero index in an array in Structure may result in data reading error.

33. [Moeller XC-CPU101] Added MW_bit address.

34. [Schneider MODBUS TCP/IP] Fixed an issue where bool array addresses are not correctly displayed after importing an XSY file

35. [OMRON EtherNet/IP NJ/NX Series] Added support for Import / Export.

36. [Schleicher XCX 300/800] Added MD_STRING address type. Added support for importing LocalVariable(POU).

37. [Rockwell Micro850] [OMRON CJ/CS/CP (Ethernet – FINS/TCP)]

[Beckhoff TwinCAT 3 ADS/AMS (Ethernet)] [Rockwell - Free Tag Names]

Fixed issues relating to tag import.

38. [XINJE XD Series (Ethernet)] Expanded address ranges.

39. [XINJE XD Series MODBUS TCP/IP] Added new driver

40. Fixed an issue where off-line simulation cannot be closed normally when using certain drivers.

10 Apr 2020 V6.04.01.291

Corrections

(16)

1. Fixed an issue where in [System Parameters] » [Security], certain settings are not correctly saved.

2. [Basic and Advanced HMIs] Fixed an issue where the setting of system register LB-12089 is not retained after rebooting HMI.

3. [cMT] Updated printer driver suite to hplip 3.19.12 version.

4. Fixed issues concerning compilation of cMT-G03 project files.

5. [cMT] Added system registers that support configuring devices up to device 64.

6. [cMT] Fixed a comparison logic issue of “>=” in macro.

7. [Serial Pass-Through] Updated the virtual COM driver. On Win10 computers, the driver can work properly after installation without the need for changing BIOS setting.

Driver Updates

41. [MODBUS RTU, RTU over TCP]

[MODBUS RTU Zero-based Addressing] [MODBUS Hex

Addressing] [ELSIST MODBUS RTU]

[CD MODBUS RTU]

Fixed an issue where HMI may stop operating when setting 0x register ON. This issue only affects versions ranging from 6.04.01.078 to 6.04.01.286

42. [Mitsubishi A2A/A2U/A2AS/A2USH] Added A2USH device type.

43. [BACnet/IP Server] Fixed an issue that causes the server to not work properly.

New Features

1. Added Opacity setting in View tab. This setting adds transparency effect to the common window, overlay windows, and window layers. The screenshot below shows the middle object, placed in a different window layer, having transparent effect.

2. Added support for showing user-defined tags and system registers in Address Grid.

(17)

3. Added support for showing the label tag name of the object (if a label tag is used). This setting can be found in View tab.

cMT Series

All features listed in this section is available exclusively for cMT series only

1. [Touch Gesture]

Added the touch gesture feature. (applicable only for cMT3152X, cMT3162X)

2. [Enhanced Security Mode]

Added support for user login with Microsoft AD (LDAP protocol).

3. [Direct Window]

[Indirect Window]

Added support for changing window position dynamically. This setting can be found in the Position tab in the object settings window.

4. [Meter]

For the customized meter style, changed pointer width and

length setting value to percentage instead, and allowed wider

range of values for selection. With the new settings, using a

1:1 picture as pointer style is possible, as shown in the

following compass example application.

(18)

5. [Numeric]

Added support for using Scientific Notation for Numeric objects, as shown in the object on the left in the screenshot below.

6. [Trend Display]

Added support for setting decimal places for Y-axis values. This setting can be found in the Data Format tab in the object settings window.

7. [Calendar]

Added output feature. By tapping on a date in the calendar, the date can be output to the designated addresses.

8. [History Data Display]

Added watch feature. By tapping on a record in History Data

Display object, data in the selected row can be output to the

designated addresses. This setting can be found in the General

tab in the object settings window.

(19)

9. [System Parameters]

Added a new option: “Set value when leaving focus”. When this option is selected, values will be written upon leaving the input mode of a Numeric / ASCII object, even if not by pressing the ENTER key. This setting can be found in General tab of System Parameter Settings.

10. [Backup(Per-page)]

[Backup(Global)]

Added support for separating files according to date or number of rows when saving backup as CSV file.

11. [Recipe Database]

Added bit access support for BCD, HEX, Binary data types.

12. [Database Server]

Enabled TLS/SSL encryption and server verification when using MySQL. This feature can be configured in TLS/SSL tab.

13. [Flow Block]

Added support for drawing non-vertical/horizontal lines as shown in the following screenshot.

14. [Action Trigger]

[Combo Button]

Added support for transferring multiple files in a folder using File Transfer (FTP).

15. [Video Input]

Added support for setting the recording time for Video Input.

cMT Diagnoser

1. Added Macro Debug tool.

(20)

cMT Viewer

1. Added support for cMT Viewer to retain the value of the system register PLW-9134 (language mode (on tablet)). That is, when cMT Viewer is opened next time, it resumes last language setting.

Drivers

1. [MICRO TREND UTREND UTC SERIES]

Added new driver.

2. [KUKA EtherNet/IP (Implicit Messaging)]

Added new driver.

6 Apr 2020 v6.03.02.463

Corrections

8. [cMT] Fixed comparison logic issue of “>=” in macro.

9. [Basic and Advanced HMIs]Fixed an issue where the setting of system register LB-12089 is not retained after rebooting HMI.

10. [Serial Pass-Through] Updated the virtual COM driver. On Win10 computers, the driver can work properly after installation without the need for changing BIOS setting

(21)

Driver Updates

44. [MODBUS RTU, RTU over TCP] [MODBUS RTU Zero-based Addressing] [MODBUS Hex Addressing] [ELSIST MODBUS RTU]

[CD MODBUS RTU]

Fixed an issue where HMI may stop operating when setting 0x register ON. This issue only affects versions ranging from 6.03.02.349 to 6.03.02.460.

45. [Mitsubishi A2A/A2U/A2AS/A2USH] Added A2USH device type.

46. [MICRO TREND UTREND UTC SERIES] Added new driver.

47. [LS XBM/XBC/XGK CPU DIRECT] [LS XGK Cnet] [LS XBM/XBC FEnet (Ethernet)]

Expanded address range.

13 Feb 2020 v6.03.02.393

Corrections [EasyBuilder Pro]

• Fixed an issue where preloading fonts can make the program unable to start properly.

• Fixed an issue where Modbus Server cannot read PLC data correctly.

• Fixed an issue where device IP related system registers are incorrect when using Modbus Server (Ethernet interface).

• Fixed an issue where minor position adjustment of multiple selected objects using the arrow keys is impossible.

• Fixed an issue where compilation may fail when the project contains an error GIF file.

• Disabled monopoly setting of the default window in project templates.

• Fixed an issue where certain project file settings may not be saved correctly.

• Fixed an issue where system registers relating to Device no Response window may be ineffective.

(22)

• Fixed an issue where connecting certain Ethernet type PLC again after running on-line simulation is impossible.

• (L/XL/P Series) [Event Display] Fixed an issue where the incorrect elapsed time is displayed.

• [Data Transfer (Per-page)] Fixed an issue where “0 is short of space” message shows when opening the settings window of this object.

• [cMT] Fixed an issue where connection may not be established successfully due to the delayed reply from database server to ALTER command that occurs when using MariaDB 5.5.

• [cMT] Fixed an issue where a printer may be mistakenly displayed as installed when it is being re-installed after installation fails with error.

• [Macro] Fixed an issue where RAND function does not output properly.

• [Macro] Fixed a number of compilation issues.

• [Macro] Fixed an issue where macro functions StringInsert and FLOAT2ASCII cannot be executed properly.

• [Macro] Fixed an issue where certain calculations in macro may not be carried out correctly.

[EasyConverter]

• Fixed potential DLL security vulnerabilities.

[cMT Viewer]

• Fixed an issue where cMT viewer cannot connect to the device whose project file was compiled and downloaded using an earlier version of EasyBuilder Pro.

Driver Updates

• [Modbus] Fixed an issue where setting 0x /1x address range may start with an incorrect read address.

• [OMRON EtherNet/IP (NJ/NX Series)] Fixed connection issue that occurs after disconnection.

• [MODBUS] Added 64-bit addresses.

• [BACnet/IP] Fixed an issue where data cannot be accessed for a period of time under communication using COV mode.

• [Schneider SoMachine M Series (Ethernet)] Added support for communication with M241 firmware v5 or later (PLC software using Machine Expert).

• [CODESYS V2 (Symbolic Addressing)] Added support for accessing bits for Word data type.

• [Delta AS300 MODBUS RTU/ASCII][ Delta AS300 MODBUS /TCP/IP] Added L and L_Bit addresses.

• [Schneider MODBUS TCP/IP] Added %TM_V, %TM_P, %TM_Q, and %X addresses.

• Siemens S7-1200/1500 Series: Added support for importing .ap15_1, .ap16 files. (TIA Portal V15.1 V16)

• [Beckhoff TwinCAT PLC – Free Tag Names (Ethernet)] Fixed an issue where compilation error may occur due to incorrect identification of Tag address type.

• [Beckhoff TwinCAT PLC – Free Tag Names (Ethernet)] Fixed an issue where incorrect value may be obtained after reading a tag using Modbus TCP/IP Gateway.

• [Beckhoff TwinCAT PLC – Free Tag Names (Ethernet)] Fixed an issue where String arrays cannot be read correctly.

• [CODESYS V3 (Ethernet)] Fixed an issue where data types: LINT, ULINT, LREAL cannot be access properly.

Supplementary Note

From version 6.03.01.239 or later, [Siemens S7-1200/S7-1500 (Symbolic Addressing) (Ethernet)] driver is no longer applicable for L and B Series models. Instead these models can use the [Siemens S7-1200/S7- 1500 (Absolute Addressing) (Ethernet)] driver.

(23)

15 Nov 2019 v6.03.02.257

New Features

• Added support for cMT-CTRL01

• Basic Series HMIs with Ethernet: Added support for VNC Server.

[EasyBuilderPro common features]

• Added support window layers, a way of organizing objects in a window. Having added layers to a window, objects can be placed within different layers as appropriate. Objects in selected layers can be displayed while those in other layers are invisible, which greatly facilitates the screen

(24)

design process.

• Expanded system picture library. New libraries include generic icons across multiple themes, industrial buttons and switches, P&ID symbols……etc.

• Added “Apply” button to the object property settings window. This button allows saving of the settings without having to close the window.

• Added support for search function and the use of hashtag for the picture libraries in the Browse Libraries interface.

(25)

• Added [Duplicate to Every State], [Duplicate to Every Language], and [Duplicate to Every State and Language] shortcut buttons into text settings in Home tab which can be used to duplicate the current text settings of the selected object to its other states or languages.

• Moved settings relating to Recipe Database to the Data / History tab

[cMT Series]

• Added support for 64-bit data type.

• Added [BACnet Schedule] object. This feature is only applicable when using the [BACnet/IP]

driver and it helps visualize and access schedule data in BACnet controller with a graphical UI.

• [Recipe View] Made whether or not to display specific columns configurable.

• [MQTT] Added support for Google Cloud IoT Core.

• [MQTT] Added support for using nested structure for Topic Subscriber under JSON (Advanced) mode.

• [MQTT] Added support for automatically building data structure using JSON template under JSON (Advanced) mode.

• [Backup (per page)] [Backup (global)] Added support for using SQL Query as data source.

• [Picture Viewer] Added support for playing GIF-format images.

• [Option List] Added row height setting.

• [Alarm Bar] [Alarm Display] [Event Display] [Event Bar Chart] Added dynamic category range setting.

• [Action Trigger][Combo Button] Added [Write constant string] option for Set Word action.

• [Action Trigger][Combo Button] Added [File Transfer (FTP)] action.

• [Function key] Added line feed option for keyboard input.

• [File Browser] Added [Select] command.

• [System Parameter Setting] Added [Trigger release actions anyway if touch moves out of the button] option.

• Added system register LB-12665 : open USB/SD card download/upload dialog.

• Added the following system registers relating to Wi-Fi hotspot feature:

(26)

o LB-12666 : Disable/enable Wi-Fi Hotspot o LB-12667 : Refresh Wi-Fi Hotspot setting o LW-12006 (16 words) : Wi-Fi Hotspot SSID o LW-12022 (32 words) : Wi-Fi Hotspot password

[Utility Manager]

• (cMT Series) Added cMT Diagnoser. This tool can be used to access the data of HMI (cMT Series models, including Gateway models) and the PLC it’s connected to, the communication status and details between HMI and PLC, and the communication status between HMI and MQTT Server.

View data

View communication status with PLC

(27)

View communication status with MQTT server

Corrections

• [Backup] Fixed an issue where LB-9039 (status of file backup activity) is not set ON when backing up data to EasyPrinter.

• [Window Copy] Fixed an issue where the pictures in a window are not copied simultaneously when window copying from an earlier version of project file.

• [Data Sampling] Fixed an issue where [Set OFF after sampling finished] option is not canceled after changing from Trigger-based to Time-based mode.

• Fixed an issue where frequently writing same values to specific system reserved registers (LW- 9134, LB-9019 and LB-9033) for a long period may cause system instability.

[cMT Series]

• [Database Server] Fixed an issue where re-connecting to MS SQL Server frequently for a long period will stop data from updating.

[cMT Viewer]

• Fixed an issue where pictures or texts appear blurry when in 1:1 ratio and either project screen width or height is smaller than that of cMT Viewer.

[UtilityManager]

• Added support for [cMT Server OS Update].

• [EasyWatch] Added MODBUS RTU (Zero-based Addressing) driver.

• [Serial Pass-Through] Fixed an issue where cMT Gateway’s pass-through parameters cannot be correctly set.

• [Ethernet Pass-Through] Fixed an issue where Ethernet Pass-Through cannot be used when the default gateway IP address is not set on PC.

• [Ethernet Pass-Through] Added support for using this feature on Gateway Series.

Driver Updates

• Added support for 64-bit data type for the following PLC series:

o [MODBUS] [Rockwell CompactLogix/ControlLogix/Micro850]

o [OMRON EtherNet/IP NJ/NX]

(28)

o [OPTO22 CONT Protocol]

o [EMERSON ControlWave]

o [CODESYS V2/V3]

o [Schneider SoMachine M]

o [Beckhoff TwinCAT]

• [BACnet/IP Server] Added support for tags that shows server status and fixed disappeared Alarm objects.

• [Allen-Bradley Compact/Control Logix - Free Tag Names] Added support for multi-dimensional array.

• [Barcode Scanner/Keyboard] Expanded BARCODE address range.

• [Bosch Rexroth SIS (Symbolic Addressing)] Added support for importing SYM file.

• [FATEK FB/FBs/B1/B1z Series] Added support for T_FBe, C_FBe addresses.

• [SAIA S-BUS (Ethernet)] Expanded Flag, Input, and Output address ranges.

• [Siemens LOGO (Ethernet)] Added support for LOGO 0BA0 model.

• [CODESYS V3 (Ethernet)] Added support for Toshiba Motorola Byte device.

• [Modbus TCP/IP] Fixed an issue where incorrect byte-swapping occurs when a value is mis- written to LW-10518.

• [KOYO DIRECT] Added support for cMT-G03 serial bridge.

• [Motrona MC700] Added support for CODE_Bit address.

• [PARKER SLVD Series] Fixed an issue where writing specific values to specific address will fail.

• [Siemens S7-300/ET200S (Ethernet)] Expanded I, Q and M address ranges.

• [Siemens S7-1200/S7-1500 (Symbolic Addressing) (Ethernet)] Added support for importing tags from blocks under groups.

• [Siemens S7-1200/S7-1500 (Symbolic Addressing) (Ethernet)] Fixed an issue where selecting a single tag in Tag Manager is ineffective.

• [Weintek Built-in CODESYS], [CODESYS V3 (Ethernet)] and [Schneider SoMachine M Series (Ethernet)] Fixed data transfer issue of REAL array.

26 Jul 2019 v6.03.01.239

Removed Feature [cMT Series]

• PLC Web Browser: This feature is no longer supported.

New Features

[EasyBuilderPro common features]

• Added support for HMI5120XL model.

• Toolbar: added a Remove button to toolbar that allows the removal of shape, picture, and sound settings when multiple objects selected on screen editor.

[cMT Series]

• Added support for cMT-iV6 model.

• System settings: added support for system registers relating to private address index:

PLW9200~PLW9215, PLW9230~PLW9260.

Corrections

• Function Key: fixed issue where "Return to previous window" and "Close window" option cannot be saved properly.

• Screen edit: fixed issue relating to incomplete rendering of BMP images in the editing screen.

(29)

• Utility Manager: fixed issue where a PC cannot establish connection for Ethernet Pass-through via WiFi.

Driver Updates

• BACnet/IP: now supports Alarms.

(30)

09 Jul 2019 v6.03.01.197

Removed Feature [cMT Series]

• PLC Web Browser: This feature is no longer supported.

New Features

[EasyBuilderPro common features]

• Added support to change security settings of multiple objects simultaneously.

• Trend Display: added "Relative time mode" option.

[cMT Series]

• MQTT: added support for Azure IoT Hub cloud service.

• Action Trigger: improved operation; for example, it is now possible to change the action order by using drag-and-drop.

• Action Trigger: added "Check condition recursively when actions ended" option in Value Changed mode.

• Combo button, ASCII: added support for designating a word address as a condition in the Security settings.

• Added support for system register LW-9216: result of importing email data.

[OPC UA Server]

• Added support for import/export of information model tag file in XML format.

[Utility Manager]

• cMT Series: added the Ethernet Pass-through tool. The HMI used for Ethernet Pass-through must be using the runtime from this version or later series.

[cMT Viewer]

• PC version: added print screen feature (right click menu)

• Mobile version: added support for hiding the Start button.

• added support for monitoring non-visible objects for Diagnoser. Example of objects include Data Sampling, Event Log, and PLC Control.

Drivers

• Siemens S7-1200/S7-1500 (Symbolic Addressing)(Ethernet): added new driver.

Driver Updates

• CODESYS V2 (Symbolic Addressing): now supports accessing the bits in a word tag.

(31)

27 Jun 2019 v6.02.02.428

Corrections

• Function Key: fixed issue where Line Feed keyboard setting cannot be correctly saved.

• MQTT: fixed issue where messages may not be published after connection with PLC is resumed following disconnect.

• cMT Viewer: fixed issue of rapidly switching between pages that contain large number of objects causes HMI to crash.

• cMT Viewer: fixed issue where rectangles with particular settings cause HMI to crash.

Driver Updates

• Panasonic MINAS-BL KV Series: added support for connecting to multiple devices.

• GE Fanuc RX3i (Ethernet): fixed issue where communication only possible with slot 1.

• Delta EtherNet/IP (AS Series): fixed issue where using macro commands to write to bit address not possible.

• ABB TotalFlow FCU: fixed issue where object addresses are incorrect after mult-copying objects that use this driver.

• CANBus 2.0b General: fixed general communiations issues.

06 Jun 2019 v6.02.02.392

Corrections

• Label Tag Library: fixed issue where error may occur when importing an XLSX file.

• Event Display: fixed issue where elapsed time does not show in the editing screen.

• System Parameter Settings: fixed issue of sequence number in device list incorrect.

• Event Display, String Table (all HMI models except cMT Series): fixed problem of switching string table content between multiple languages not possible.

• OPC UA Server: fixed issue where server may not start properly when using BACnet Server.

• Database Server: fixed issue where connection with MS SQL database may not work properly under an unstable network environment.

Drivers

• Epson Robot Controller: added new driver.

Driver Updates

• BACnet Server: fixed an issue where BACnetProperty data is displayed incorrectly on the HMI.

• Schneider SoMachine M Series (Ethernet): fixed an issue where canceling tag import may lead to driver being removed.

(32)

10 May 2019 v6.02.02.351

New Features

[EasyBuilderPro common features]

• StringMDS: new function added.

Corrections

• Find/Replace tool: fixed an issue that prevented PLC tags from showing up in interface.

• Event Display, String Table: fixed issue where texts from string table are displayed incorrectly in the Event Display.

• cMT-G01: fixed issue where OPC UA server might not start if a large number of tags are defined.

Driver Updates

• Schneider UniTelway: fixed communication issue which occurs after running for extend period of time.

05 Apr 2019 v6.02.02.340

New Features

[EasyBuilderPro common features]

• USB audio output: added to HMI5070P and XL HMI models. Must use OS ver. 20190325 or later and select "USB audio driver" when downloading the project file.

Corrections

• MQTT: fixed issue where data may be sent more than once under certain circumstances.

• MQTT: fixed issue where conflict in Client ID may lead to unstable system.

• Changing drivers: fixed issue where software stops running when changing the driver under certain circumstances.

• Event Log: fixed issue where project cannot be compiled properly when configuring watch address as a user-defined tag.

• Object changing positions: fixed issue where position of objects on screen may change when zooming in/out of the window under Tile mode.

• Shape: fixed issue where shapes are not displayed correctly.

• Hemi Head Rg font: this font can now be used.

• Trend Display: fixed issue where trend curve and Y Axis are not correctly displayed.

• Macro, Recipe Database: fixed issue where using certain recipe names can make recipe-related macros unusable.

• Macro: fixed issues concerning the Recipe Query functions.

• Macro: fixed issues where Unicode not supported for Trace functions.

• Macro: fixed issues where Recipe address cannot be used for the String GetEx function.

• Event Display: fixed abnormal behaviors that may occur when the watch address cannot be accessed.

• String Table: fixed issue where section names are missing after import.

• ASCII: changed the maximum allowable number of words to 64.

• Address tags: fixed issue where software may abruptly stop when opening an Address Tag.

(33)

[cMT Series]

• VNC Viewer: fixed issue where changing page when connected to a VNC Viewer may cause system crash.

• Diagnoser: fixed issue where Strings cannot be edited in the Diagnoser utility.

• cMT-FHD: fixed multi-touch problems.

• YET R, Malgun Gothic Bold, and Malgun Gothic Semilight fonts: fixed display issues when using these fonts.

• Email: fixed issue where screenshots are not attached to an outgoing email.

• History Data Display: fixed issue where a few items in datalogs are not correctly displayed.

[EasyConverter]

• added support to save relatively large DTL files by splitting into separate files.

• added support to add BOM when converting a file to a CSV file.

• fixed issue where data format is identified incorrectly when reading datalog files.

Driver Updates

• Siemens S7-300 MPI: fixed issue where an unknown screen appears when configuring the device address as a user-defined tag.

• Bosch Rexroth IndraControl: fixed issue where tags cannot be imported.

• Barcode Scanner/Keyboard: expanded the maximum readable number of words to 64 for a USB barcode device.

• CODESYS V3 (Ethernet): fixed issue where defining initial values can cause writing problems.

Also fixed issue where accessing arbitrary string lengths is impossible.

• Omron EtherNet/IP (NJ/NX series): fixed writing issues that occur when using a string in a structure.

• BACnet/IP server: added support for COV protocol and fixed issue where multivalue cannot be read.

• IEC 60870-5-104 IEC104 Client: fixed communication issues with Axon server.

• Mitsubishi QJ71E71 (Ethernet) and Mitsubishi MELSEC Q/L Binary Mode: fixed communications issues.

• GMTCNT PLC Modbus TCP/IP: fixed issues of IP, QP addresses.

• Modbus Gateway: added support for Tag PLC and using station numbers provided by the client.

• Koyo Direct: fixed pass-through issue.

• Yokogawa FA-M3: added checksum and end-character settings.

• Modbus Server: fixed issue where data cannot be read after enabling security settings for gateway function.

(34)

17 Mar 2019 v6.02.02.241

New Features

[EasyBuilderPro common features]

• Line Draw: added support for selecting the begin and end type of arrows

• Numeric Input: added "Display confirmation request" option.

• MQTT: added "UTC Time" option for timestamp setting.

• MQTT: added "JSON (Advanced)" content format option for MQTT Topic Publisher. This format allows users to custom define the format of JSON messages.

• MODBUS TCP/IP Gateway: added support for mapping to PLC tag addresses.

[cMT Series]

• Numeric Input: added "Trigger Action" setting option.

• VNC Viewer: added support for VNC Viewer object.

• Calendar: added support for Calendar object.

• Function Key: added "Display calculator window" option which allows opening a calculator for performing simple calculations on HMI.

• Database Server: added support for using server name as the address when MS SQL Server is used (ex. HOST\SQLEXPRESS).

• Trend Display: added "Disable Y-axis scrolling with swiping up/down" and "Disable zoom"

options.

• Control Token: added system register PLW-11998 "Control Token release countdown".

• Option List: added support for "Classic" style.

• PLC Control: added system register LB-9017 to disable write-back in PLC control's [Change Window] option.

• (all cMT models with touchscreen): added support for system register LW-9041 ~ LW-9045

"touch status and touch position"

[cMT Gateway Series]

• cMT-G03: added support for system register LB-12664: Cache Hit.

[OPC UA Server]

• added support for adding Remote HMI nodes.

Drivers

• Panasonic MINAS-BL KV series: new driver

(35)

27 Feb 2019 v6.02.01.396

New Features

[EasyBuilderPro common features]

• Fixed a few compatibility issues that may occur when converting some earlier versions of project files.

• Fixed an issue where certain sequence of operation steps may result in abnormal stop of EasyBuilder Pro software.

• Fixed an issue where, after changing the connected device in project file, objects' addresses are not automatically mapped to the corresponding addresses with the same name.

• Fixed an issue where CODESYS REAL format tag cannot be used by some objects.

• Fixed issues relating to group operation and group libraries.

• Event Log:Fixed an issue where the background color may not be correctly displayed after import/export.

• Fixed an issue where playing video using a model without audio output may lead to memory leak.

• MQTT: Fixed an issue where resent messages are published twice by error.

• Fixed issues related to the display of Address Grids and object addresses.

• System Parameter Settings: Fixed an issue where the device list may show incorrect items when using different addresses for read/write operations.

• Numeric: Fixed an issue where numeric display and calculation may generate incorrect result when using different addresses for read/write operations.

• Timer: Fixed an issue where server disconnect alarm shows and HMI can no longer be operated when ET value exceeds the upper limit of the address type used.

[cMT Series]

• Fixed an issue where Bank Gothic Medium font is not correctly displayed.

• ASCII: Fixed an issue where keyboard pops up regardless of relevant settings.

• Added support for system register LB-9017: disable write-back in PLC Control [Change Window]

• Fixed an issue where "Turn" transition effect cannot be performed.

[cMT Viewer]

• Fixed an issue where closing a window using multiple objects simultaneously might lead to system crash.

[EasyConverter]

• Fixed an issue where event.db file cannot be opened.

• Fixed an issue where contents in "Category" column from event.db file are read incorrectly.

• Fixed an issue where millisecond information is incorrectly show

• added gui.c31 to the firmware folder (to support web browser)

Drivers

• Added Modbus TCP/IP (Zero-based Addressing) driver.

• Added Mocbus RTU (Zero-based Addressing) driver.

• Added Modbus TCP/IP (32 Bit) driver.

• Added Azbil Controller (CPL) driver.

• Added Azbil MODBUS TCP driver.

• Added Azbil MODBUS RTU driver.

• Added Panasonic MINAS-BL DV Series driver.

(36)

• Updated ABB EtherNet/IP (Implicit Messaging) driver: added support for EIP Adaptor mode.

• Updated BACnet/IP Server driver: support for configuring communication port.

• Updated Beckhoff ADS (Absolute Addressing) driver: added support for MD_FLOAT, ID_FLOAT, QD_FLOAT addresses.

• Updated IDEC MicroSmart driver: added support for write operation for D_Bit.

• Updated MODBUS Server driver: optimized command processing logic.

• Updated ODVA EtherNet/IP (Explicit Messaging): support for Binary Access.

• Updated ODVA EtherNet/IP (Implicit Messaging) and Yaskawa MP2300Siec [Ethernet] drivers:

added support for input interface for RPI parameter.

• Updated Omron CJ/CP driver: fixed issues relating to Pass Through feature.

• Updated Omron E5CN/E5EZ/E5ZN driver: added C0_Bit~C3_Bit addresses for accessing C0~C3 bits.

• Updated Omron EtherNet/IP (NJ/NX Series) driver: fixed issue where multi-dimensional arrays cannot be correctly read. Fixed tag import issues.

• Updated OPC UA Client driver: fixed an issue where EasyBuilder Pro may not function properly when Display Name is empty. Also added support for write operation with ASCII objects for Word Array.

• Updated S7-1200 (Symbolic Addressing) (Ethernet) driver: fixed an issue where multi- dimensional arrays cannot be correctly read.

• Updated S7-1200/S7-1500 (Absolute Addressing) (Ethernet) driver: fixed an issue where using multi-layered Function Block or Data Block in a TIA project may result in incorrect tag mapping after import.

• Updated Schneider SoMachine M Series driver: fixed an issue where String cannot be written.

• Updated Schneider SoMachine M Series (Ethernet) [CODESYS V3 Ethernet] driver: fixed an issue where considerably long arrays may not be successfully transferred using Data Transfer.

• Updated Siemens S7-400 (Ethernet) driver: Fixed an issue where DBBn cannot be read.

• Updated Yaskawa DX100/DX200/FS100/YRC1000 Robot Controller (Ethernet) driver: added support for accessing multiple devices and fixed an issue where the value in DX100 may sometimes be unstable.

13 Dec 2018 v6.02.01.209

New Features

• Added support for cMT3071, cMT-FHD, and MT8053iE models.

• Renamed the cMT-HDMI model to cMT-HDM.

[EasyBuilderPro common features]

• Address Tag Library: added support for tag search.

• MQTT: support for-

o "Use top-level key 'd' for all addresses" option.

o Option for TLS/SSL encryption.

• Draw: now supports security settings for Line, Arbitrary Line, Link Line, Arc, Ellipse/Circle, Pie, Rectangle, Polygon, and Scale.

• Function Key: added Inc/Dec function keys for use with keyboard. These keys can increase/decrease a value by 1 when being used for numeric input.

• Trend Display: can now include Date information for the time scale.

[HMI5000B, HMI5000L Series]

• Added support for saving data to USB Disk 2.

(37)

[cMT Series]

• Action Trigger object: This is a global-scope object that can trigger a series of pre-defined actions after a pre-set idle time or when the value of the designated address meets the specified

condition.

• PLC Browser object: This web browser is intended for access to a PLC's web server for parameter configuration. The browser shows locally on the HMI screen only; it will not display on

cMTViewer (when connected remotely).

• Trend Display: added support for:

o choosing fonts.

o controlling channel visibility by setting bit state.

• Combo Button: added support for an action group setting that is similar to the [Action Trigger]

object. As a result, the order of the trigger actions can be configured.

• SQL Query Result Viewer: now automatically adjusts the column width to fit the content.

• Operation Log and Database Server: can now synchronize the Operation Log to the database.

• MQTT: add support for Buffer settings under Sparkplug B mode.

• for cMT3071, cMT3072, cMT83090, cMT3103, and cMT3151 models only: can now update the system setting using the description file (*.conf) during project download.

[cMT Gateway Series]

• cMT-G03 model: now supports MODBUS TCP/IP Server.

[cMT Viewer]

• PC version of cMTViewer has the following updates:

o now supports fullscreen display

o can manually load a project file. This eliminates the time spent uploading the file from the HMI. The loaded project file must be identical to the file downloaded to the HMI unit.

• Android version of cMTViewer now supports customized keyboard.

• Android and iOS version of cMTViewer now support using vibration mode on mobile devices for event notification.

• Alarm Bar and Alarm Display objects: supports dynamically changing the event category to be displayed.

• EasyDiagnoser: added a Watch feature- watch addresses can be added by clicking the + icon.

Drivers

• Added Toshiba TOSVERT VF (MODBUS TCP)driver.

• Added Toshiba TOSVERT VF (EtherNet/IP)driver.

(38)

24 Oct 2018 v6.01.02.228

New Features

• Added cMT-G03 and cMT-G04 models.

• Added System Keyboard-Flat and System Keyboard-Standard in the Picture Library to create keyboards. Note: Some project templates contain the new keyboard arrangement in

Windows#83-90.

• Flow Block object: added new arrow style.

• System Parameter Settings: added Time Sync/DST tab so that you can enter HMI time zone information in an outgoing email so that email clients can correctly interpret and display the actual send time. HMI time zone can be viewed or changed using System tag LW-11276 during runtime.

[cMT Series]

• Function Key object: added a title bar and start position settings for popup windows.

• Numeric Input and ASCII Input objects: added [Relative to object] option for the popup position setting of a popup keypad.

• Event Bar Chart object: added Title Bar Format setting.

• SQL Query object: added support for accessing SQLite database stored in a USB disk or SD card.

• Control Token feature: added Idle Timeout setting. The control token will be released when the token processor's HMI remains untouched for a period of time longer than Idle Timeout.

• cMT-HDMI model: added support for adjusting the audio volume and backlight brightness using System Tag registers:

o LW-9051 for audio volume

o LW-9040 for the backlight brightness.

• cMT3072/3090/3103/3151 models: added support for 3G/4G dongle (with OS version 20180723 or later).

[cMT Gateway Series]

• Database Server feature added.

• Data Sampling feature added, with support for saving historical data to local memory and synchronization with the database.

• Event Log feature: added support for saving historical data to local memory and synchronization with the database.

[cMT+CoDeSys]

• Added ability to change the CoDeSys network settings using System Tag registers.

[cMT Viewer]

• Added 1:1 display mode for the PC version (accessed using the right-click menu)

[EasySystemSetting]

• Added support for cMT Series.

Corrections [EasyBuilder Pro]

• Numeric object:

o Fixed an issue where inputting value is not possible when interpolation is used.

o Fixed an issue that prevents entering a negative number and decimal points.

References

Related documents

Students will practice clinical skills needed to prepare them to work in a hospital, doctor’s office, or medical clinic.. C360

Key findings from the 2012/2013 FSNAU study include: (i) 41 percent of total surveyed households received remittances (ii) remittances reach all parts of Somali society

AAIN or the African Agribusiness Incubator Network formed recently by the UniBRAIN interest group aims to work together as a Pan-African community of agribusiness incubators

In summary, the coupling from the orthogonal modes to superposed modes in a highly birefringent suspended-core fiber by an acoustically modulated Bragg grating in combination with

You’re working in a business environment and want to specialize in the football industry.. You’re passionate about football and want specialized education to devote

In this work, we investigate the initial interaction of water and oxygen with different surface reconstructions of GaP(100) applying photoelectron spectroscopy, low-energy

their annual salary. For approximately 100 managers with sub- stantial responsibility for performance, their bonus is limited to a maximum of two-twelfths of their annual salary.

Studies were included if they (i) re- ferred to the quality improvement collaborative ap- proach [ 2 , 5 , 8 , 16 ], defined in line with previous reviews as consisting of all