• ABB EtherNet/IP (Implicit Messaging)
• IDEC MicroSmart FC6A Series
• Motrona CT-150, CT15012B, MC700, and BY340
• Yaskawa MP3000 PLC Series (Ethernet)
10 April 2018 v6.00.02.112
New Features
• Added following system registers:
o LB-12656: enable Diagnoser (set ON), disable (set OFF) o LB-12657: Diagnoser password free (when ON)
o LW-11756: Diagnoser password
o LW-11760: CODESYS firmware status (0: error, 1: start, 2: stop) o LW-11761: CODESYS application status (0: error, 1: start, 2: stop) o LW-11762: CODESYS login status (0: error, 1: login, 2: logout)
• Additional debugging support- HMI can collect system information (HMI model name, OS version, EBPro version) and save to USB disk.
• cMT Series: added Crystal and Flat styles to simplify appearance settings for Recipe View object.
• cMT Series: added support for configuring down actions and up actions separately in the Combo button.
• MQTT:
o added support for MQTT v3.11 communication protocol.
o added support for specifying length of Registration ID/Username/Password.
o added support for removing bracket [] in JSON formatted messages.
o added support for setting the number of digits after decimal point for Float.
o added support for selecting whether to include timestamp (ts) and to verify timestamp (ts).
Note: these additional features for MQTT allow better compatibility for cloud service providers such as IBM Cloud, Microsoft Azure, Alibaba Cloud, etc.
• Added support for changing label tag name.
• Added new mechanism to indicate related addresses in address grid.
o Red: addresses used explicitly by an object.
o Yellow: addresses used implicitly by an object.
o For example, a numeric display object uses LW-0 as the read address. The LW-0 address, explicitly used, will be shown in red, whereas LW_bit-000 to LW_bit-015, implicitly used, is shown in yellow.
• Improved security of project by prohibiting unauthorized decompilation attempts to obtain original project file.
• Added support for keyword filtering in system register window.
• Added support for the following models:
o cMT3103 10.1"(1024x600pixels) HMI with support for cMTViewer. One Ethernet port, CANbus, Wi-Fi Functionality, two serial ports. 10-28VDC input. EasyAccess license included.
o cMT3090 9.7"(1024x768pixels) HMI with built-in CODESYS (requires a license and dedicated OS).
Corrections
• Fixed issues where compilation is not properly carried out when simultaneously using user-defined tag and array.
• Fixed an issue where local address cannot be used for certain settings when HMI name is not
"Local HMI".
• Fixed an issue where LW-9030 shows incorrect time after running system for a long period.
• Fixed an issue where text position of certain objects may be influenced when increasing number of languages.
• Fixed an issue where certain system fonts may not be found.
Driver Updates
• CODESYS V3 (Ethernet) driver: Fixed an issue where String data type may not be accessed. Also fixed an issue where running driver may cause CODESYS to crash.
23 February 2018 v6.00.01.220
New Features
• Added system register LW-12024: disable alarm buzzer (set ON)
• cMT Viewer: added support for the Pie Chart object.
Corrections
• Fixed issues relating to [Find/Replace] function.
• Event Log object (cMT Series only): Fixed an issue where data is incorrectly displayed.
• PLC Control object (cMT Series only): Fixed an issue where PLC object is ineffective when simultaneously selecting [Write data to PLC] and [Use window no. offset].
• OPC UA object (cMT Series only): Fixed communications problem when using a cMT-SVR and the OPC UA Server.
Driver Updates
• Rockwell EtherNet/IP (CompactLogix) driver: adjusted the maximum number of reads and writes.
• Mitsubishi FX5U- Binary mode (Ethernet) and Mitsubishi FX5U - ASCII Mode (Ethernet) drivers:
added support for Remote Password.
• Emerson SI-Ethernet Modbus TCP/IP driver: renamed to Control Techniques SI-Ethernet Modbus TCP/IP.
• BACnet/IP driver: fixed problem when importing tags that have the user-defined object name causing incorrect communications.
17 January 2018 v6.00.01.174
New Features
• Updated version of EZwarePlus
o Software name changed from EZwarePlus to EBPro
o User Interface format changed from menus to ribbon layout
• Added support for the following models:
o cMT3072 7.0"(1024x600pixels) HMI with support for cMTViewer. Two Ethernet ports, three serial ports. 10-28VDC input. EasyAccess license included.
o cMT3090 9.7"(1024x768pixels) HMI with support for cMTViewer to view HMI screen from remote location (iPad, Android device, or PC). Dual Ethernet. EasyAccess included.
o cMT-G01 IIoT Gateway (no display capability) with two Ethernet ports and three serial ports.
o cMT-G02 IIoT Gateway (no display capability) with support for OPC UA and/or MQTT (client or server) and WiFi connectivity (802.11b/g/n)
o cMT-HDMI cMT without built-in display but with HDMI port to attach a touchscreen monitor of any size. Resolution up to 1920x1080pixels.
• New SQL Query and SQL Query Result Viewer objects. Execute SQL statements, exchange data with MySQL database, and show SQL Query execution results.
• Enable image caching for faster screen updates (see System Parameter Settings- Enable fast display mode...)
• Added additional actions for Combo button: popup window, close window, keyboard input, screen hardcopy, Acknowledge Alarms, Import Data, and Wait Until.
• Language feature extended to 24.
• System Picture Library now supports custom colors.
• System Parameter Settings option to change screen orientation: portrait or landscape.
• History Data Display and Operation Log Display objects (cMT Series only): now support crystal and flat background styles.
• Diagnoser app now supports cMT models.
• Picture object: can now generate an object using the Windows clipboard.
• Event Log (cMT Series only): provided statistical information for occurrence and elapsed time.
• Backup object (cMT Series only): can now backup Data Logs that record data using Customized File Handling mode.
• MQTT (cMT Series only): now supports AWS (Amazon Web Services) IoT.
• Added system register LW-11406 for Wi-fi signal strength (dBm).
o 0, 1, 2 indicate failed connection o else signal strength
Corrections
• Fixed problem where some projects would not compress due to insufficient memory.
• Added time zones for time synchronization feature
• fixed time synchronization issue on cMT3090 and cMT5151 models
• Brightek printer driver: fixed problem with printing
• SQL Query: can now use special characters in the column name without causing SQL syntax error.
• Fixed printing problem where project screens appear displaced.
• Combo button: can now use Recipe Address (would cause application to halt)
• Fixed problem when using LW and LW_Bit system addresses simultaneously for an object; would cause application to halt.
cMTViewer:
• Password prompt now displays after incorrect password attempted
• IP settings are now correct after changing the cMT-D090 IP address
• EasyAccess 1.0: can now use with HMI5070B model
New Drivers
• Bosch Rexroth SIS (Absolute Addressing)
• Emerson ROC800 Series Free Tag names
• Emerson SI-Ethernet Modbus TCP/IP
• CoDeSys V2 (Absolute Addressing)
• CoDeSys V2 (Absolute Addressing) Ethernet
• Delta AS300 MODBUS RTU/ASCII
• Delta AS300 MODBUS TCP/IP
• Brother Speedio (Ethernet)
Driver Updates
• OPC UA driver:
o (cMT-G01/cMT-G02 only): support for web interface to change OPC UA server parameters, edit nodes, manage certificates, and configure PLC comm. parameters.
o support for automatic synchronization of user accounts for OPC UA server and
Enhanced Security Mode. Changes made in the web interface are immediately available in server.
o optimized speed when device disconnect message is updated at client end.
o improved comm. efficiency when reading large amounts of data o added tags relating to PLC connection stats.
• BACnet/IP driver: now support configuring communication port.
• Siemens S7-1200/S7-1500 (Absolute Addressing) Ethernet driver: Ranges for I, Q, M, Byte, Word, and DWORD now extended to 65532.
• Mitsubishi FX Series (FXOS/FXON/FX1S/FX3G) driver: now supports pass-through function.
• Schneider MODBUS RTU, TCP/IP, and UniTelway drivers: can now import tags
• MODBUS RTU driver: fixed problem when using 0x_single_coil address and running simulation mode.