• No results found

Boron Doped Diamond Samples

Determination of tramadol in pharmaceutical forms and urine samples using a boron-doped diamond electrode

Determination of tramadol in pharmaceutical forms and urine samples using a boron-doped diamond electrode

... biological samples, such as blood, urine, and serum, is of great importance because the results of ana- lyses provide information about long-term abuse and can also be used for foren- sic ...

15

Exploiting the extreme properties of boron doped diamond in electroanalysis

Exploiting the extreme properties of boron doped diamond in electroanalysis

... for samples with high concentrations of boron, N D was set at a value of 1 × 10 16 cm -3 unless otherwise ...intrinsic diamond with N D << 10 16 cm -3 ...

230

Electrochemical characterisation of single crystal boron doped diamond

Electrochemical characterisation of single crystal boron doped diamond

... One of the drawbacks of many scBDD studies in the literature is the lack of information regarding material properties. Hence it is often difficult to draw reliable conclusions between differing studies. Here, a range of ...

271

Boron-doped Diamond Film Electrode as Voltammetric Sensor for Cetirizine

Boron-doped Diamond Film Electrode as Voltammetric Sensor for Cetirizine

... * E-mail: [email protected] Received: 8 February 2018 / Accepted: 9 March 2018 / Published: 5 June 2018 Electrochemical behaviour of cetirizine on bare boron-doped diamond electrode was investigated ...

15

Electrochemical Oxidation of 2-Nitrobenzaldehyde on Boron-Doped Diamond Anodes

Electrochemical Oxidation of 2-Nitrobenzaldehyde on Boron-Doped Diamond Anodes

... Electrochemical measurements were performed using a computer controlled by Potentiostat/Galvanostat model PGZ 100 associated to "Volta-Master 4" software. A conventional three electrodes cell (100 cm 3 ) thermo regulated ...

11

Thermo electrochemistry of boron doped diamond from fundamentals to application

Thermo electrochemistry of boron doped diamond from fundamentals to application

... I am thankful to Warwick Chancellors International scholarship for providing funding for my Ph.D. studies and Element Six for providing all the diamond samples. Thanks to Warwick Electrochemistry and ...

233

Development of boron doped diamond electrodes for heavy metal detection

Development of boron doped diamond electrodes for heavy metal detection

... filter samples prior to analysis via ICP-MS, potentially losing vital information about the sample ...of samples in the ICP torch means that this technique can only provide information on total ionic metal ...

220

Electrooxidation of Bupirimate: A Comparative Study of SnO2 and Boron Doped Diamond Anodes

Electrooxidation of Bupirimate: A Comparative Study of SnO2 and Boron Doped Diamond Anodes

... Galvanostatic electrolysis was carried out with a volume of 75 mL aqueous solution of bupirimate 230 mg/L during 120 minutes. The range of applied current density was 20 to 60 mAcm -2 and samples were taken, at ...

12

3D-nanostructured boron-doped diamond for microelectrode array neural interfacing

3D-nanostructured boron-doped diamond for microelectrode array neural interfacing

... the diamond surface by e-beam evaporation and turned into 50 nm nanoparticles by heating at 700  C for 3 ...The samples are then trans- ferred into a plasma enhanced CVD reactor (“Black Magic” AIXTRON) ...

12

Electrochemical degradation of imazalil and pyrimethanil by anodic oxidation on boron doped diamond

Electrochemical degradation of imazalil and pyrimethanil by anodic oxidation on boron doped diamond

... A conventional three-electrode cell (100 cm 3 ) thermoregulated glass cell was used (Tacussel Standard CEC/TH). The anode was a square plate of BDD electrode with effective surface area of 1 cm 2 , whereas the cathode ...

8

Electroanalytical Determination of Captopril in Pharmaceutical Formulations Using Boron-Doped Diamond Electrodes

Electroanalytical Determination of Captopril in Pharmaceutical Formulations Using Boron-Doped Diamond Electrodes

... Captopril lacks of an aromatic chromophore required for facile direct UV detection and also has two chiral centers; therefore its determination in pharmaceutical dosage forms is very challenging. Here, we developed an ...

11

Controlling Physical and Chemical Bonding of Polypyrrole to Boron Doped Diamond by Surface Termination

Controlling Physical and Chemical Bonding of Polypyrrole to Boron Doped Diamond by Surface Termination

... Fig. 3 shows SEM secondary electron images and intensity profiles obtained on the border between PPy layer and O-BDD or H-BDD, respectively. Contact mode nanoshaving was performed near the border on i) PPy on ...

10

Phenol Electrooxidation in Different Supporting Electrolytes Using Boron-Doped Diamond Anodes

Phenol Electrooxidation in Different Supporting Electrolytes Using Boron-Doped Diamond Anodes

... Electrolyte samples were collected durign the electrolysis for COD measurement by the standardized colorimetric technique using dichromate (Hach, Germany) and TPC concentration using the Folin-Ciocalteau method ...

15

Development of a Boron-Doped Diamond Electrode for the Simultaneous Detection of Cd2+ and Pb2+ in Water

Development of a Boron-Doped Diamond Electrode for the Simultaneous Detection of Cd2+ and Pb2+ in Water

... Figure 7. Calibration curves of Cd 2 + and Pb 2 + The linear correlation coefficient of the calibration curve of the ion being measured reflects the detection precision of an electrode and is an important evaluation ...

15

Nanomolar Quantification of Polydatin at Boron Doped Diamond Electrode. Application in Dietary Supplements

Nanomolar Quantification of Polydatin at Boron Doped Diamond Electrode. Application in Dietary Supplements

... 5 M reduces the oxidation peak of polydatin by 12 % (inset Figure 5C). Based on reported results, it can be considered that our developed methodology is satisfactory selective and can be applied for application in real ...

10

Electronic and physico-chemical properties of nanometric boron delta-doped diamond structures

Electronic and physico-chemical properties of nanometric boron delta-doped diamond structures

... quantitative boron doping profile deduced from such profiles, as recently published using a STEM-HAADF based method 30 , was not derived as this ground value of the profile was not reached so that the inferred ...

36

Electrooxidation of cypermethrin pesticide:  A Comparative Study of SnO2 and Boron Doped Diamond Anodes

Electrooxidation of cypermethrin pesticide: A Comparative Study of SnO2 and Boron Doped Diamond Anodes

... 3470 Galvanostatic electrolysis was carried out with a volume of 75 cm 3 aqueous solution of 50 mg/L. The range of applied current density was 40 to 80 mA/cm 2 and samples were taken, at predetermined intervals ...

10

Electrochemical Oxidation of Diethyl Phthalate Using Boron Doped Diamond, Modified with Gold Particles

Electrochemical Oxidation of Diethyl Phthalate Using Boron Doped Diamond, Modified with Gold Particles

... Figure 6 shows the HPLC chromatograms of samples of the electrolyte obtained at the beginning of the electrolysis and after 240 min of degradation. In this figure is possible to observe that during the ...

9

Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode

Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode

... In this work, for the first time we proposed electrochemical behavior and development of an analytical procedure for quantification of pesticide clomazone. Electrochemical behavior of clomazone’s at ...

9

Anodic Destruction of 4-methyl Pyrimidine Solution Using a Boron-Doped Diamond Anode

Anodic Destruction of 4-methyl Pyrimidine Solution Using a Boron-Doped Diamond Anode

... Galvanostatic electrolysis was carried out with a volume of 75 cm 3 aqueous solution of initial COD 0 (900 mg/L). The range of applied current density was 10 to 30 mA/cm 2 c and samples were taken, at ...

12

Show all 10000 documents...

Related subjects