• No results found

DC-link fault protection

DC fault protection structures at a DC-link node in a radial multi-terminal high-voltage direct current system

DC fault protection structures at a DC-link node in a radial multi-terminal high-voltage direct current system

... a DC fault from the healthy system ...any DC fault current is shared between two DCCBs instead of one DCCB in the faulty branch suffering the fault ...novel DC fault ...

17

Fault current characterisation in VSC-based HVDC systems

Fault current characterisation in VSC-based HVDC systems

... The DC-side line faults in high-voltage direct-current (HVDC) systems utilising voltage-source converters (VSCs) are a major concern for multi-terminal HVDC systems in which complete isolation of the faulted ...

7

Protection Scheme for HVDC Converters to Limit Fault Current against Dc-Side Faults

Protection Scheme for HVDC Converters to Limit Fault Current against Dc-Side Faults

... a protection scheme for HVDC converters against DC-side faults with current suppression capability by combining and connecting double thyristor switch scheme across ac output terminals of the HVDC ...of ...

12

DC fault protection of multi-terminal HVDC systems using DC network partition and DC circuit breakers

DC fault protection of multi-terminal HVDC systems using DC network partition and DC circuit breakers

... acting DC Circuit Breakers (DCCBs) at strategic locations to allow the entire Multi-terminal HVDC (MTDC) system to be operated interconnected but partitioned into islanded DC network zones following ...a ...

10

Low voltage ride through enhancement of DFIG based wind turbine using {DC} link switchable resistive type fault current limiter

Low voltage ride through enhancement of DFIG based wind turbine using {DC} link switchable resistive type fault current limiter

... crowbar protection at the rotor circuit to protect the rotor side converter (RSC) during grid ...novel DC-link switchable resistive-type fault current limiter (SRFCL) to improve the LVRT ...

26

Review and evaluation of the state of the art of DC fault detection for HVDC grids

Review and evaluation of the state of the art of DC fault detection for HVDC grids

... into protection zones. When a fault happens inside a predefined zone, the whole affected zone is disconnected using DC circuit breakers or other devices such as DC-DC converters at ...

6

Offshore AC fault protection of diode rectifier unit based HVDC system for wind energy transmission

Offshore AC fault protection of diode rectifier unit based HVDC system for wind energy transmission

... voltage-error-dependent fault current injection is proposed to regulate the WT current during offshore AC fault transients and quickly provide fault current to detect fault for OWFs connecting ...

12

Continuous operation of radial multi-terminal HVDC systems under DC fault

Continuous operation of radial multi-terminal HVDC systems under DC fault

... a DC fault on a single branch does not cause significant disturbance to the operation of the healthy parts of the DC ...Some DC circuit breakers (DCCBs), ...for DC fault ...

11

Review of DC fault protection for HVDC grids

Review of DC fault protection for HVDC grids

... block DC faults but also provide flexible control, as listed in Table ...HVDC link with overhead lines, ...where DC faults occur relatively frequently compared to its counterpart with ...extinguish ...

21

Comparison of Power Flow Control in HVDC Link with ANN and PI Controller

Comparison of Power Flow Control in HVDC Link with ANN and PI Controller

... the protection of the converter in situations when inverter side does not have sufficient dc voltage support (due to a fault) or does not have sufficient load requirement (load ...the dc ...

8

DC fault protection strategy considering DC network partition

DC fault protection strategy considering DC network partition

... 2. DC current and voltage of MMC during DC line-to-line fault A typical half-bridge MMC based converter has been considered for analysing the DC fault ...permanent DC ...

5

Review of DC fault protection for HVDC grids

Review of DC fault protection for HVDC grids

... block DC faults but also provide flexible control, as listed in Table ...HVDC link with overhead lines, ...where DC faults occur relatively frequently compared to its counterpart with ...extinguish ...

20

Studies of coordinated zone protection strategies for DC grid

Studies of coordinated zone protection strategies for DC grid

... converter DC link voltage with oscillations immediately after the DC line-to-line fault ...converter DC currents showing rapid ...to DC side during DC fault are ...

6

Fault current characterisation in VSC-based HVDC systems

Fault current characterisation in VSC-based HVDC systems

... The DC-side line faults in high-voltage direct-current (HVDC) systems utilising voltage-source converters (VSCs) are a major concern for multi-terminal HVDC systems in which complete isolation of the faulted ...

8

Fault Protection of a Loop Type Low Voltage DC Bus Microgrid

Fault Protection of a Loop Type Low Voltage DC Bus Microgrid

... of DC loads are increasing in our daily uses, the low voltage DC (LVDC) distribution system is becoming ...conventional protection scheme for DC Bus Microgrid uses circuit breaker on AC side, ...

8

Bridge-Type Fault Current Limiter to Improve the Transient stability enhancement of Doubly Fed Induction Machine based Wind Generator

Bridge-Type Fault Current Limiter to Improve the Transient stability enhancement of Doubly Fed Induction Machine based Wind Generator

... the dc side connected to the dc link and the ac side interfaced to the ...the dc link voltage Edc and the rotor line reactive power QL as inputs and produces the necessary outputs so ...

10

Investigation of different system earthing schemes for protection of low voltage DC microgrids

Investigation of different system earthing schemes for protection of low voltage DC microgrids

... for DC Distribution” proposes the IT earthing arrangement naturally reduces the earth current during faults and thus is more protective of adjacent metalwork than the TT earthing arrangement ...the ...

6

A low-loss hybrid bypass for DC fault protection of modular multilevel converters

A low-loss hybrid bypass for DC fault protection of modular multilevel converters

... after fault detection. The fault current suppression time in this case is irrelevant so long as the SRB semiconductors are not exposed to destructive ...

10

Dynamic Input Current Low-Frequency Ripple Evaluation and Reduction by Inverter with Variable-Speed, Sensor less Induction Motor Drive

Dynamic Input Current Low-Frequency Ripple Evaluation and Reduction by Inverter with Variable-Speed, Sensor less Induction Motor Drive

... This is the reason why open-loop, constant-v/f drives are mostly used in low performance fan and pump type loads. In this paper, we propose a modified control scheme that includes the torque control and a current ...

7

Improving fault ride through of three phase voltage source inverter during symmetrical fault using DC link fault current limiter

Improving fault ride through of three phase voltage source inverter during symmetrical fault using DC link fault current limiter

... novel DC link fault current limiter (DLFCL) based VSI FRT scheme to enhance the FRT capability of the VSIs during symmetrical ...the fault even at zero grid voltage as recommended by ...the ...

5

Show all 10000 documents...