• No results found

Deuterium Oxide

Histamine release from human leukocytes: studies with deuterium oxide, colchicine, and cytochalasin B

Histamine release from human leukocytes: studies with deuterium oxide, colchicine, and cytochalasin B

... Agents known to interact with either microtubules or microfilaments influenced the antigen- induced release of histamine from the leukocytes of allergic individuals. Deuterium oxide (D 2 O) which stabilizes ...

8

Body Composition Estimatives by Anthropometry, Bioelectrical Impedance and Deuterium Oxide Dilution in Obese Adolescents

Body Composition Estimatives by Anthropometry, Bioelectrical Impedance and Deuterium Oxide Dilution in Obese Adolescents

... of deuterium oxide (gold standard), from measurements of BIA and anthropometry using the variables sex, age, height, arm, and triceps and suprailiac skinfold thickness, resistance and reactance to estimate ...

9

Application of the deuterium-oxide dose-to-mother technique to determine the exclusivity of breastfeeding in women in Kanye, Botswana

Application of the deuterium-oxide dose-to-mother technique to determine the exclusivity of breastfeeding in women in Kanye, Botswana

... 19. Haisma H, Coward WA, Albernaz E, et al. Breast milk and energy intake in exclusively, predominantly and partially breast-fed infants. Eur. J Clin Nutr. 2003;57(12):1633-1642. 20. Medoua GN, Sajo Nana EC, Ndzana ACA, ...

6

A Trial Implementation of Using Deuterium Oxide Dose-to-Mother and Dilution Technique Among Beninese Children: Challenge and Critical Points

A Trial Implementation of Using Deuterium Oxide Dose-to-Mother and Dilution Technique Among Beninese Children: Challenge and Critical Points

... Deuterium oxide dose-to-mother technique for the determination of breast milk intake and water from sources other than human milk, consist in administrating a dose of 30 g of deuterium oxide ...

9

Total body water estimations in healthy men and women using bioimpedance spectroscopy: a deuterium oxide comparison

Total body water estimations in healthy men and women using bioimpedance spectroscopy: a deuterium oxide comparison

... as deuterium oxide, hydrogen, tritium, oxygen-18, and oxygen, are time-consuming and expen- sive and require cumbersome equipment and ...as deuterium oxide ...

6

Temperature Variation of Second Virial Coefficient for Deuterium Oxide

Temperature Variation of Second Virial Coefficient for Deuterium Oxide

... comparison of the calculated and experimental results for deuterium oxide is not present illustrate in this section. There is a large discrepancy at lower temperatures (T≤ 285.055(K)), the second virial ...

5

The impact of deuterium oxide on the properties of resorcinol-formaldehyde gels

The impact of deuterium oxide on the properties of resorcinol-formaldehyde gels

... assist the addition of formaldehyde to resorcinol [25]. As previously mentioned, sodium carbonate is termed a cata- lyst and its concentration is expressed as resorcinol/catalyst molar ratio (R/C) and R/C values of 100, ...

8

Early structural remodeling and deuterium oxide derived protein metabolic responses to eccentric and concentric loading in human skeletal muscle

Early structural remodeling and deuterium oxide derived protein metabolic responses to eccentric and concentric loading in human skeletal muscle

... These distinct architectural adaptations to CON as opposed to ECC training might suggest that the contrac- tion-specific differential growth of skeletal muscle may be controlled by different responses of muscle anabolism ...

11

Deuterium oxide dilution can be used to determine the net energy content of feeds for dairy cattle and goats

Deuterium oxide dilution can be used to determine the net energy content of feeds for dairy cattle and goats

... The NEL values of the basal diet, rice bran, and hominy feed were calculated as the sum of milk energy, change in body energy, and estimated fasting heat production per kilogram of feed [r] ...

6

Metastable production from electron impact dissociation of water, deuterium oxide, and hydrogen peroxide.

Metastable production from electron impact dissociation of water, deuterium oxide, and hydrogen peroxide.

... data corresponding to this threshold is the first fitting Gaussian peak in Figure 4.8 (see. previous discussion), which is correlated with the released kinetic energy o f 11.57eV[r] ...

106

THE EQUILIBRATION OF RADIOSODIUM (Na24), RADIOPOTASSIUM (K42), AND DEUTERIUM OXIDE (D2O) IN HYDROPIC HUMAN SUBJECTS

THE EQUILIBRATION OF RADIOSODIUM (Na24), RADIOPOTASSIUM (K42), AND DEUTERIUM OXIDE (D2O) IN HYDROPIC HUMAN SUBJECTS

... Approximately 94 per cent of exstudies in rabbits and in patients without edema, changeable sodium, 95 per cent of exchangeable estimated that 95 per cent of body potassium ex- potassium[r] ...

10

Circadian Rhythm of Output from Neurones in the Eye of Aplysia: I  Effects of Deuterium Oxide and Temperature

Circadian Rhythm of Output from Neurones in the Eye of Aplysia: I Effects of Deuterium Oxide and Temperature

... The tectibranch mollusc, Aplysia californica, possesses cerebral eyes which, when isolated at constant temperature and in darkness, produce an output of compound action potentials CAPs t[r] ...

16

THE TOTAL BODY WATER AND THE WATER TURNOVER IN PREGNANCY STUDIED WITH DEUTERIUM OXIDE AS ISOTOPIC TRACER

THE TOTAL BODY WATER AND THE WATER TURNOVER IN PREGNANCY STUDIED WITH DEUTERIUM OXIDE AS ISOTOPIC TRACER

... where the value of X is proportional to the "turnover rate" and represents that fraction of the total body water "turned-over" per unit of time "t." D200 is the concentration of deuteriu[r] ...

8

GENETIC EFFECTS OF DEUTERIUM OXIDE IN DROSOPHILA MELANOGASTER

GENETIC EFFECTS OF DEUTERIUM OXIDE IN DROSOPHILA MELANOGASTER

... The genetic effects studied were sterility, the recessive lethal mutation rate in the X chromosome, meiotic and mitotic crossing over between X chromosomes, crossing over b[r] ...

10

THE MEASUREMENT OF TOTAL BODY WATER IN THE HUMAN SUBJECT BY DEUTERIUM OXIDE DILUTION: WITH A CONSIDERATION OF THE DYNAMICS OF DEUTERIUM DISTRIBUTION

THE MEASUREMENT OF TOTAL BODY WATER IN THE HUMAN SUBJECT BY DEUTERIUM OXIDE DILUTION: WITH A CONSIDERATION OF THE DYNAMICS OF DEUTERIUM DISTRIBUTION

... Total body water Since serial determinations of serum heavy water concentration indicated that equilibrium had been obtained in two hours, this two hour value was used to calculate the v[r] ...

16

ELECTROLYTE COMPOSITION OF BONE AND THE PENETRATION OF RADIOSODIUM AND DEUTERIUM OXIDE INTO DOG AND HUMAN BONE

ELECTROLYTE COMPOSITION OF BONE AND THE PENETRATION OF RADIOSODIUM AND DEUTERIUM OXIDE INTO DOG AND HUMAN BONE

... of sodium corrected for extracellular so- On the other hand, Davies, Kornberg,' and Wilson dium by chloride content per kilogram of fat- 26 using Na24 as a tracer did detect 20 per cent [r] ...

11

The accuracy of currently used WHO´s Body Mass Index cut-off points to measure Overweight and Obesity in Syrian women: A correlation study

The accuracy of currently used WHO´s Body Mass Index cut-off points to measure Overweight and Obesity in Syrian women: A correlation study

... Randomly selected 66 women of the participating group were also subjected to BF% determination by deuterium oxide. BF% was estimated from total body water (TBW). TBW was determined according to plateau ...

9

THE VOLUME OF EXTRACELLULAR BODY FLUIDS IN MALNUTRITION

THE VOLUME OF EXTRACELLULAR BODY FLUIDS IN MALNUTRITION

... Estimation of extracellular and total body water in newborn human infant with radioactive sodium and deuterium oxide, J. Suisse de Med[r] ...

5

Body Composition of Adults Living with HIV in Two Cities in Ghana

Body Composition of Adults Living with HIV in Two Cities in Ghana

... the deuterium oxide method [16], with Fourier Transform Infrared Spectrometer ...of deuterium oxide (about 30g) to drink after which the container was rinsed with ...for deuterium ...

6

THE INFLUENCE OF IONIZING RADIATION ON THE BODY FLUID COMPARTMENTS OF PATIENTS WITH MALIGNANT LYMPHOMA

THE INFLUENCE OF IONIZING RADIATION ON THE BODY FLUID COMPARTMENTS OF PATIENTS WITH MALIGNANT LYMPHOMA

... During this phase the volumes an even larger expansion of the extracellular fluid of distribution of deuterium oxide and inulin and/ than in the patients who were maintained on the or th[r] ...

13

Show all 8122 documents...

Related subjects